Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cold Test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Cold Trap Replacement Project Report

This report documents the replacement of the Mechanisms Engineering Test Loop (METL) cold trap. The work involved preparation of the facility to replace the cold trap, removal of the existing welded cold trap from the sodium purification circuit, installation of a new replacement cold trap, completion of associated welds and examinations, restoration of instrumentation and heaters, and controlled return of the cold trap circuit to service. The replacement represented a significant maintenance evolution because the cold trap is an integral welded component of the sodium system. As a result, the work required coordinated control of sodium chemistry, deliberate formation of freeze plugs, inert gas management, precision cutting and welding, and a staged reheating and refill sequence. The activity was executed using procedural controls intended to protect personnel, preserve system cleanliness, and maintain the integrity of the sodium boundary throughout the work. This report provides a narrative summary of the milestone, including the purpose of the work, the pre-job system condition, the major field activities performed, observations made during execution, and the resulting post-work condition of the METL cold trap circuit.

42 ENGINEERING↗

Multiple Environmental Influences on the Lightning of Cold-Based Continental Convection. Part II: Sensitivity Tests for Its Charge Structure and Land–Ocean Contrast

In Part I, an electrification scheme was described and a simulation of an observed cold-based storm from the U.S. Great Plains was validated with electrical observations. Most charge in the storm was separated by rebounding collisions of secondary ice originating from prior graupel–snow collisions. In this Part II, sensitivity tests are performed with the control simulation (Part I) and influences from environmental factors (aerosols, temperature, moisture, and shear) on lightning are elucidated. Environmental factors [e.g., convective available potential energy (CAPE)] controlling updraft speed are salient. When ascent is reduced by 30% and 70%, flashes become 70% fewer and disappear, respectively; faster ascent promotes positive cloud-to-ground (+CGs) flashes. Since cloud base is too cold (1°C) for coalescence, cloud condensation nucleus aerosol concentrations do not influence the lightning appreciably. The electrical response to varying concentrations of active ice nuclei is limited by most ice particles being secondary and less sensitive—a natural “buffer.” Imposing a maritime sounding suggests that the land–sea contrast in lightning for such storms is due to the vertical structure of environmental temperature and humidity. Weak CAPE, and both entrainment and condensate weight from a low cloud base, suppress ascent and charging. Maritime thermodynamic conditions reduce simulated flash rates by two orders of magnitude. Reducing aerosol loadings from continental to maritime only slightly reinforces this suppression. Last, a conceptual model is provided for how any simulated storm is either normal because graupel/hail is mostly positively charged or else is inverted/anomalous because graupel/hail is mostly negatively charged, with environmental factors controlling the charging. Impacts from microphysical processes, including three processes of secondary ice production, on lightning are analyzed.

54 ENVIRONMENTAL SCIENCES↗

Self-Powered Autonomous Sensing System for Arctic Ocean using a Frequency-multiplied Cylindrical Triboelectric Nanogenerator

An autonomous sensing system for collecting environmental observations in the Arctic region is critical for the estimation and prediction of climate change. Ocean waves are a great source of energy for these sensing systems but there has been limited research done on small-scale energy harvesting applications in the Arctic Ocean (subsea or surface). The available wave energy in the Arctic Ocean is lower than the typical ocean wave energy due to the low wave frequency, height, and operating months. Although the available wave energy depends on the specific location in the Arctic Ocean, the wave height decreases everywhere during the winter (Jan-March) [1]. Our target location in this work is the Beaufort and Chukchi Seas, which are ice covered for about 195 days per year leaving only a few months (June-November) for wave energy harvesting [2]. During these few months, the average wave frequency is 0.2 Hz and the most common wave frequency is around 0.15 Hz. Many energy harvesting methods are unsuitable for use in the Arctic Ocean because of to the cold temperature, low wave frequency, and low wave height. Triboelectric nanogenerators (TENG) are one of the few energy harvesting methods that excel in these conditions. Zhong et al. [3] designed a stacked pendulum-structured TENG for low-frequency ocean wave energy and reported the device generated a peak power density of 11.2 W/m3 under the low wave frequency of 0.2 Hz. The autonomous sensing system we developed for the Arctic Ocean, the Arctic-TENG, is based on a frequency-multiplied cylindrical TENG (FMC-TENG) which is an optimized TENG configuration for Arctic Ocean conditions due to the high power density under low-frequency wave conditions [4]. Figure 1 shows an FMC-TENG with multiple pairs of free-standing triboelectric-layer mode materials (Aluminum and FEP). The mass and magnet attached to the rotor store gravitational potential energy which is released as kinetic energy when the potential energy overcomes the repulsive magnetic force generated by the opposing magnet attached to the stator. This force unbalance triggers a sudden rotation and swinging motion of the mass which increases the angular velocity of the system and therefore enhances the output power of the TENG system. The main components of the Arctic-TENG are a 3D-printed rotor and stator, electric and dielectric material adhesive tape, and bearings. All these materials were cold-soaked and tested at -40 °C in a chest freezer. Both the 3D-printed parts and adhesives were confirmed to have a minimal effect from the cold temperature. Multiple bearings were tested and the starting torque of each one was compared both at room temperature and -40 °C. The bearing with the lowest starting torque at -40 °C was selected for use in the Arctic-TENG. The Arctic-TENG was tested using an out-of-water motor-driven wave simulator (Figure 2). The wave simulator allows for controlled testing at a wave height of 0.2 m and frequencies between 0.1 Hz to 0.5 Hz. This wave simulator was used for both room temperature and -40 °C testing. The Arctic-TENG generated significantly more power at -40 °C compared to room temperature for each frequency tested. The system stored energy in a supercapacitor via a power management circuit, and the amount of energy stored per day was calculated at different wave frequencies. Based on the conditions at the proposed deployment location (days of non-ice-covered ocean and wave frequency), the amount of stored energy per year from Arctic-TENG was calculated to be enough energy for two transmissions every day. Durability testing was completed on the Arctic-TENG at room temperature to determine the lifetime. The rotor of the Arctic-TENG was attached to a DC motor and spun continuously for several millions of cycles without degradation of the electrical output, demonstrating the feasibility for long-term operation.

Jung, Hyunjun↗

Characterizing falling particle curtain receivers at commercially relevant scales: Research Performance Progress Report (RPPR-1)

Sandia will construct a cold flow receiver test platform in order to characterize falling particle curtain receivers at commercially relevant scales. While Sandia has extensive experience in R&D of falling particle curtain receivers, most have been at pilot scale and smaller - on the order of 1 MWth with characteristic dimensions of nominally 1-2 m to adequately collect solar energy from the heliostat field at the National Solar Thermal Test Facility (NSTTF). However, scaling up receivers to commercially relevant scales (25 MWth and above) will require a thorough understanding of particle curtain dynamics at larger scales, especially longer drop heights, for design certainty. The goal of this project will be to construct a cold falling particle curtain test rig capable of simulating particle characteristics that are expected in a commercial scale CSP plant, namely the drop height, curtain thickness, and particle mass flow rate (normalized by length of curtain). This will enable data collection on curtain opacity and spread, both of which are correlated to receiver efficiency and reliable construction, for commercially relevant scales. It will also permit validation of numerical models that will enable detailed receiver characterization and design past currently validated scales.

14 SOLAR ENERGY↗

Characterizing falling particle curtain receivers at commercially relevant scales: Research Performance Progress Report (RPPR-1)

Sandia will construct a cold flow receiver test platform in order to characterize falling particle curtain receivers at commercially relevant scales. While Sandia has extensive experience in R&D of falling particle curtain receivers, most have been at pilot scale and smaller - on the order of 1 MW th with characteristic dimensions of nominally 1-2 m to adequately collect solar energy from the heliostat field at the National Solar Thermal Test Facility (NSTTF). However, scaling up receivers to commercially relevant scales (25 MW th and above) will require a thorough understanding of particle curtain dynamics at larger scales, especially longer drop heights, for design certainty. The goal of this project will be to construct a cold falling particle curtain test rig capable of simulating particle characteristics that are expected in a commercial scale CSP plant, namely the drop height, curtain thickness, and particle mass flow rate (normalized by length of curtain). This will enable data collection on curtain opacity and spread, both of which are correlated to receiver efficiency and reliable construction, for commercially relevant scales. It will also permit validation of numerical models that will enable detailed receiver characterization and design past currently validated scales.

14 SOLAR ENERGY↗

Testing of the Defense Waste Processing Facility Cold Chemical Dissolution Method in Sludge Batch 10 Qualification

For each sludge batch that is processed in the Defense Waste Processing Facility (DWPF), the Savannah River National Laboratory (SRNL) tests the applicability of the digestion methods used by the DWPF Laboratory for elemental analysis of Sludge Receipt and Adjustment Tank (SRAT) Receipt samples and SRAT Product process control samples. DWPF SRAT samples are typically dissolved using a method referred to as the DWPF Cold Chemical or Cold Chem Method (CC), (see DWPF Procedure SW4-15.201- 2.1).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Monitoring of Unvented Roofs with Fibrous Insulation, Diffusion Vents, and Interior Vapor Control in a Cold Climate

This research involved construction of a conditioned test hut in a cold climate (Climate Zone 5A) with multiple side-by-side instrumented roof rafter bays. This work examined seven experimental unvented roofs and one code-compliant control hybrid ccSPF-cellulose roof over three winters and following summers. Examined variables included insulation material (fiberglass and cellulose), the presence or absence of a ridge diffusion vent (vapor-open material at the roof ridge to promote drying), the effect of various interior vapor control membranes (fixed and variable permeance), the effect of interior relative humidity, and the effect of interstitial airflow (from the interior into the cavity). This experiment was run over three winters, changing variables of interior conditions, roof configurations/materials, and the addition of intentional air leakage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Virtual and Augmented Realities to Support Development, Training, Deployment, and Operations of Remote Systems - 20516

Throughout the U.S. Department of Energy complex, there is a need to deploy new, unique equipment and systems for cleanup activities, waste processing, infrastructure repair, and decommissioning and demolition in radioactive and hazardous environments. The new equipment often consists of custom systems created by integrating and modifying commercial technologies. In addition, the systems are deployed in unique environments due to limited access, waste properties, and the presence of previously installed equipment or infrastructure that has been left in place. The deployment of custom systems that are 'turnkey' ready for first-time installation and application has its risks. Use of test platforms and mockups for cold (i.e., non-radioactive) testing is one method to mitigate that risk: however, full-scale test mockups for operations such as waste retrieval and tank inspection can be expensive and must be modified to incorporate the uniqueness of each application. An alternative to full-scale mockups is to use three-dimensional (3D) virtual environments and virtual reality (VR) technology to develop interactive virtual test beds. These can be used throughout the down-selection, development, system integration, operational planning, operator training, and mission execution phases of a task. Virtual test beds are readily reconfigured, can be used for multiple tasks, support multiple users in parallel, and can accommodate enhancements and changes not originally planned or conceived in the initial design. Virtual test beds also provide a platform for developing and testing augmented reality (AR) tools for improving operator efficiency. A VR experience has been generated for waste retrieval from a Hanford waste tank to present the potential applications of a virtual test bed. Features of the VR experience are presented, potential applications of VR and AR for remote applications are discussed, and development areas for improving future application are considered. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Quench Detection and Monitoring System for Superconducting Magnets at Fermilab

A quench detection system was developed for protecting and monitoring the superconducting solenoids for the Muon-to-Electron Conversion Experiment (Mu2e) at Fermilab. The quench system was designed for a high level of dependability and long-term continuous operation. It is based on three tiers: Tier-I, FPGA-based Digital Quench Detection (DQD); Tier-II, Analog Quench Detection (AQD); and Tier-3, the quench controls and data management system. The Tier-I and Tier-II are completely independent and fully redundant systems. The Tier-3 system is based on National Instruments (NI) C-RIO and provides the user interface for quench controls and data management. It is independent from Tiers I & II. The DQD provides both quench detection and quench characterization (monitoring) capability. Both DQD and AQD have built-in high voltage isolation and user programmable gains and attenuations. The DQD and AQD also includes user configured current dependent thresholding and validation times. A 1 st article of the three-tier system was fully implemented on the new Fermilab magnet test stand for the HL-LHC Accelerator Up-grade Project (AUP). It successfully provided quench protection and monitoring (QPM) for a cold superconducting bus test in November 2020. The Mu2e quench detection design has since been implemented for production testing of the AUP magnets. A detailed description of the system along with results from the AUP superconducting bus test will be presented.

monitoring↗

Effects of cold stress on metabolic regulation in the overwintering larvae of the Chinese white pine beetle, Dendroctonus armandi

Abstract The Chinese white pine beetle, Dendroctonus armandi Tsai & Li (Coleoptera: Curculionidae, Scolytinae), is considered the most destructive forest pest in the Qinling and Bashan Mountains of China. In recent years, winter temperature has dropped in these regions, and extremely low temperatures are hard to survive for insects. Cold hardiness becomes a crucial strategy because temperature change often leads to fluctuations in insect abundance, and the metabolism rate is a key index of resistance to cold in overwintering insects. Therefore, we investigated the relationship between the change in respiratory rate and the activity of metabolism‐related mitochondrial enzymes in D. armandi larvae under cold conditions. We found that the respiratory rate decreased, and it was matched with the activity of glutamate dehydrogenase, aconitase, and lipase during overwintering. Among the various test times under cold conditions, the respiratory rate also decreased with decreasing temperature and increased under very low temperatures. At all cold stress periods, glutamate dehydrogenase and lipase showed increased activity at higher temperatures and decreased activity under lower temperatures, but the activity of NAD‐malic enzyme, NADP‐malic enzyme, mitochondrial isocitrate dehydrogenase, and aconitase were contrary. Under all low temperatures, the activity of enzymes – except for NADP‐malic enzyme, glutamate dehydrogenase, and lipase – increased in short‐term cold stress and decreased in long‐term cold stress at 4, 0, −4, −6, −8, and −10 °C. However, at −2 °C, the activity of enzymes showed a decreasing trend in short‐term treatments and an increasing trend in long‐term treatments, except for mitochondrial isocitrate dehydrogenase. The results not only improve our understanding of the metabolic mechanism of cold adaptation in D. armandi , but also provide an important experimental basis for further study and biological pest control.

Fu, Danyang↗

Black carbon emissions from modern automated cordwood stoves for space heating

Wood burning stove design is improving as regulation become stricter for particulate matter emissions. Here, this study describes results of black carbon (BC) emissions from three modern automated wood stoves when tested in common failure modes using a test protocol that included cold-starts, high and low fuel loading densities, and use of overly large pieces of fuel. Emission sampling was performed using a dilution sampling system in tandem with an aethalometer to measure BC with high time resolution. Results show that the time-weighted average BC emission rates were 0.91, 4.30, and 1.74 g/h for the three stoves tested (A, B, and C respectively), the values, both higher and lower than the United States 2020 certification test emission limit of 2.5 g/h. The results demonstrate good performance overall, given the rigorous nature of the testing protocol used. The aethalometer data showed that the performance was relatively poor during cold-start, when the fuel was ignited and combusted without a coalbed, and when stoves failed to optimize air delivery due to specific loading and output conditions. During the cold-start test section, the average BC emission rate was seven times higher than the overall average for Stove A, 10 times above the average for Stove B, and two times above the average emission rate for Stove C. Calculations of the Average Angstrom Absorption Exponent (AAE) of the exhaust aerosol showed little correlation with BC concentration. The results show that automation results in a quantifiable reduction in particular BC emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Effect of Spark-Plug Heat Dispersal Range and Exhaust Valve Opening Timing on Cold-Start Emissions and Cycle-to-Cycle Variability

The partnership for advancing combustion engines (PACE) is a US Department of Energy consortium involving multiple national laboratories and includes a goal of addressing key efficiency and emission barriers in light-duty engines fueled with a market-representative E10 gasoline. A major pillar of the initiative is the generation of detailed experimental data and modeling capabilities to understand and predict cold-start behavior. Cold-start, as defined by the time between first engine crank and three-way catalyst light-off, is responsible for a large percentage of NOx, unburned hydrocarbon and particulate matter emissions in light-duty engines. Minimizing emissions during cold-start is a trade-off between achieving faster light-off of the three-way catalyst and engine out emissions during that period. In this study, gaseous and soot emissions were measured at a distance representative of the three-way catalyst position downstream of the engine at a 2 bar net indicated mean effective pressure (NIMEP) steady-state operating condition representative of cold-start. The test matrix included sweeps of ignition timing 15 degrees-before to 10 degrees-after top dead center firing (TDCf) across three different spark-plug heat dispersal ranges (HR). Additionally, the effect of varying exhaust valve opening (EVO) timing on combustion stability and emissions was also studied. Results show that the spark plug HR affects the coefficient of variation (COV) of NIMEP under all cold-start conditions, while the impact on emissions was found to be minimal. At very retarded spark timings, colder spark plugs required higher air and fuel flow to maintain the desired 2bar NIMEP load, but the fraction of fuel energy going into the exhaust was found to be similar for all spark plugs. Finally, retarding exhaust valve timings showed a simultaneous reduction in emissions while increasing the fraction of fuel energy being fed into the exhaust. However, engine COV was also observed to increase with retarded exhaust timings.

42 ENGINEERING↗

A Section 110 Evaluation of Three Sites Associated with the Grable Test, Area 5, Nevada National Security Site, Nye County, Nevada

This report presents the results of a Section 110 recordation of the 280mm Atomic Gun emplacement and command post (CP) (26NY16244), an associated Flash Observation Point that was used to refine the gun’s firing range (26NY16243), and troop trenches used for Exercise Desert Rock V (26NY16242). All three of these resources are directly associated with the Grable test, a specific test in the Upshot-Knothole series of aboveground nuclear detonations. The Grable test occurred at 8:30 a.m. on May 25, 1953, in Area 5 of the Nevada National Security Site (NNSS). Desert Research Institute (DRI) recommends 26NY16244 and 26NY16242 eligible for listing in the National Register of Historic Places (NRHP) under a combination of the Secretary of the Interior’s Significance Criteria A and D at the national level of significance and related to the era of Nuclear Testing and the Cold War. All three of these resources are recommended as contributing elements to the Frenchman Flat Historic District (SHPO Resource No. D204).

280mm Atomic Gun↗

SR19021 Tritium Aging of Regenerated LANA.75 (Final Project Report)

The Savannah River Tritium Enterprise (SRTE) has used the metal hydride LaNi 4.25 Al 0.75 (LANA.75) in the Tritium Facilities for over two decades. LANA.75 beds store significant quantities of tritium but have a limited service life due to the radiolytic decay of tritium to He-3 within the metal matrix. It has been shown that heating tritium-aged LANA.75 under vacuum can reverse tritium aging effects, eliminating the heel of trapped hydrogen, and restoring the reversible capacity. Additional investigation is needed to ensure there are no unexpected changes to the hydride before this restoration technique is employed in full scale beds in the Tritium Facilities. This project was to be comprised of three distinct scopes: obtain tritium aging data on the sample regenerated in 2018, regenerate a tritium-aged sample at 600 °C, and perform thermal stability testing on a non-tritiated sample. Isotherms were collected on the previously regenerated sample after approximately two years of tritium aging. Isotherms were collected at 80, 100, and 120 °C. As expected, there was a decrease in the plateau pressure, an increase in plateau slope, and a portion of the “heel” of tritium trapped in the metal had been reestablished. Unexpectedly, it appeared that the plateau had shortened at the higher tritium to metal ratios as well. This is typically seen in older samples. The second scope, to regenerate a second tritium-aged LANA.75 sample, was not completed. A Task Technical and Quality Assurance Plan was written and approved, a high temperature test cell was fabricated, several pre-job briefs were held, and the hydride sample was passivated with air. Despite these successes, the hydride sample was not recovered from the legacy test cell. The third scope was to perform thermal stability testing on a “cold” LANA.75 sample. A non-tritiated sample of LANA.75 was held at 750 °C under vacuum for 200 hours to simulate exposure to multiple regeneration evolutions. Hydride isotherm performance, chemical composition, crystallinity, particle size, and morphology are compared between the pre- and post-regeneration samples. No significant changes were observed in composition, crystallinity, or particle size. Comparison of before and after isotherms showed that performance improved rather than deteriorated during the evolution. Scanning Electron Microscopy (SEM) analysis showed small growths on the particle surface after exposure to regeneration conditions. Additional testing will be required to determine the cause of these growths.

07 ISOTOPE AND RADIATION SOURCES↗

Use of a silver-based sanitizer to accelerate Escherichia coli die-off on fresh-cut lettuce and maintain produce quality during cold storage: Laboratory and pilot-plant scale tests

Outbreaks and product recalls involving romaine and iceberg lettuce are frequently reported in the United States. Novel technologies are needed to inactivate pathogens without compromising product quality and shelf life. In this study, the effects of a process aid composed of silver dihydrogen citrate, glycerin, and lactic acid (SGL) on Escherichia coli and Listeria monocytogenes concentrations on lettuce immediately after washing and during cold storage were evaluated. Sensory and quality attributes of fresh-cut iceberg lettuce were also evaluated. Laboratory results indicated that application of SGL solution for 30 s as a first step in the washing process resulted in a 3.15 log reduction in E. coli O157:H7 immediately after washing. For E. coli O157:H7 a significant difference between SGL treatment and all other treatments was maintained until day 7. On day zero, SGL led to a 2.94 log reduction of L. monocytogenes. However, there was no significant difference between treatments with or without SGL regardless of storage time. Pilot-plant results showed that samples receiving SGL spray followed by chlorinated flume wash exhibited a greater reduction (1.48 log) in nonpathogenic E. coli populations at the end of shelf life than other treatments (p < 0.05). Additional pilot plant tests were conducted to investigate the hypothesis that SGL residues could continue to impact microbial survival on the final washed lettuce. Results show that pathogens introduced subsequent to flume washing of lettuce pretreated with SGL solution were not affected by antimicrobial residues. Here, the final quality and shelf life of flume washed lettuce were also unaffected by pretreatment with SGL. In conclusion, the results of this study demonstrate that this new technology has the potential to accelerate E. coli die-off on fresh-cut lettuce during cold storage and improve product safety, while not affecting quality throughout the shelf life of the finished products.

59 BASIC BIOLOGICAL SCIENCES↗

Chemical and morphological evolution of hybrid conversion coatings in low-Earth orbit space environment

Understanding how protective coatings respond to the harsh low-Earth orbit (LEO) environment is essential for ensuring the safety, longevity, and cost-effectiveness of spacecraft. In particular, identifying environmentally friendly, non-chromate alternatives that can maintain performance under such conditions has both technological and regulatory significance. This study investigates the environmental stability of zirconium-based hybrid conversion coatings with Cu additives (Cu10 and Cu20) applied to cold-rolled steel, tested in the Materials International Space Station Experiment (MISSE) outside the International Space Station (ISS). Chemical and morphological analyses were carried out using a combination of electron microscopy and X-ray spectroscopy techniques, including scanning electron microscopy (SEM), scanning transmission electron microscopy with energy-dispersive X-ray spectroscopy (STEM-EDS), X-ray photoelectron spectroscopy (XPS), and X-ray absorption near-edge structure (XANES) spectroscopy. After exposure outside the ISS, all coatings remained structurally intact, with all exhibiting a uniform Zr-rich matrix and embedded Cu-rich clusters, while a thin Si-rich surface layer developed from interaction with space environments. Depth-resolved XPS showed a layered structure with CuO on the surface, Cu 2 O, and partial Zr(IV) reduction near Cu-rich sites, evidence of Atomic Oxygen (AO)-driven surface oxidation. These results demonstrate that Cu–Zr coatings maintain their chemical integrity and microstructure in harsh space environments, offering a non-chromate alternative for long-term aerospace protection. These insights provide valuable guidance for developing next-generation protective coatings that combine environmental sustainability with the reliability required for future aerospace and orbital applications.

36 MATERIALS SCIENCE↗

Assessment of BQ-9000 Biodiesel Properties for 2020 (CRADA CRD-15-593)

Biodiesel producers in the United States and Canada can voluntarily participate in the industry's BQ-9000 quality assurance program. This is the fourth in a series of reports documenting biodiesel quality from participating producers. Participants in the BQ-9000 program were requested to voluntarily provide data to a third-party team. This team anonymized and randomized the data prior to providing to the National Renewable Energy Laboratory (NREL) for analysis and reporting. The critical quality parameters analyzed are: sodium and potassium, calcium and magnesium, phosphorus, flash point and alcohol control, water and sediment, cloud point, acid number, free and total glycerin, monoglycerides, sulfur, oxidation stability, and cold soak filterability test (CSFT). The statistical analysis for these parameters is presented in Table ES-1.

09 BIOMASS FUELS↗

Assessment of BQ-9000 Biodiesel Properties for 2021

This is the fifth in a series of reports documenting the quality of biodiesel from U.S. and Canadian-based producers that participate in the BQ-9000 program, the biodiesel industry voluntary quality assurance program. Participants agreed to provide monthly data on critical quality parameters for calendar year 2021. The quality data was provided to a team of experts, who removed any identifying company information and provided anonymized and randomized data to the National Renewable Energy Laboratory (NREL) for statistical analysis. The critical quality parameters analyzed were: sodium and potassium (Na+K); calcium and magnesium (Ca+Mg); phosphorus (P); flash point and alcohol control; water and sediment; cloud point; acid number; free and total glycerin; monoglycerides; sulfur; oxidation stability; and cold soak filterability test (CSFT). The data was not weighted for production volume.

09 BIOMASS FUELS↗