Search NASA⌕ Search

SEARCH · Search NASA

Results for “Combined loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Submerged Fatigue Testing of Marine Energy Advanced Materials

Marine energy structures are typically made of advanced composite materials and are subjected to extreme ocean environments in service. In extreme ocean environments, seawater currents and waves load structures repeatedly, which cause two environmental conditions: water intrusion and mechanical fatigue. In prior research, the two environmental conditions were applied sequentially, where composite specimens were aged and then mechanically tested. To understand the combined effects of dynamic loading and water intrusion on composite materials, the present study involves the static and fatigue four-point bend testing of composite coupons in a water tank. The water tank was designed and built to fit either a 100 kN or a 250 kN load frame. Flexural strength value, cycles to failure, and failure mode results from submerged fatigue testing will be used to inform marine energy structure designs. The coupon-scale test method will be used to scale up to and inform methods for subsequent subcomponent testing and standards development. The benefits of designing marine energy structures to informed standards are decreased lifetime costs and increased reliability and energy production, ultimately leading to a sustainable and low-carbon energy system.

composite materials↗

Tuning Strong Metal–Support Interaction Kinetics on Pt-Loaded TiO 2 (110) by Choosing the Pressure: A Combined Ultrahigh Vacuum/Near-Ambient Pressure XPS Study

Pt catalyst particles on reducible oxide supports often change their activity significantly at elevated temperatures due to the strong metal–support interaction (SMSI), which induces the formation of an encapsulation layer around the noble metal particles. However, the impact of oxidizing and reducing treatments at elevated pressures on this encapsulation layer remains controversial, partly due to the “pressure gap” between surface science studies and applied catalysis. In the present work, we employ synchrotron-based near-ambient pressure X-ray photoelectron spectroscopy (NAP-XPS) to study the effect of O 2 and H 2 on the SMSI-state of well-defined Pt/TiO 2 (110) catalysts at pressures of up to 0.1 Torr. Further, by tuning the O 2 pressure, we can either selectively oxidize the TiO 2 support or both the support and the Pt particles. Catalyzed by metallic Pt, the encapsulating oxide overlayer grows rapidly in 1 × 10 –5 Torr O 2 , but orders of magnitude less effectively at higher O 2 pressures, where Pt is in an oxidic state. While the oxidation/reduction of Pt particles is reversible, they remain embedded in the support once encapsulation has occurred.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ELM 1016706669-AA B581 GDE01 Generator Summary pg 4-5 only

The table below shows the general load breakdown for 581GDE01. Although the total connected load exceeds the generator’s 150kW nameplate capacity, the normal configured load during standby power mode is less, which was measured at 81kW, or 54%, during preventive maintenance activities on 12/12/24. The generator’s available spare capacity must account for dynamically changing loads that can increase the total power demand at any time. If the two online VFD’s are operated at full speed the actual standby mode load is estimated to increase by 38kW, which would bring the total configured load during standby power mode to 119kW, or 79%, still within 581GDE01’s acceptable capacity. Per the LLNL Site 200 Generator Consolidation Final Study 2022, “Standby Emergency Generator nameplate ratings are based upon operation with varying load averaging 70% of the nameplate for 200 hours per year. Continuous loading between 70% and 100% will reduce a generator’s expected lifetime before a major overhaul. This is never a problem with Laboratory machines because of conservative application of generators and the reliability of the normal power system combines to keeps the load and hours down”. To achieve optimal performance and prolong generator life, the recommended generator loading is between 40% and 70%, optimally at 70%, which 581GDE01 appropriately falls within.

42 ENGINEERING↗

Characterization of 6 Li-loaded pulse-shape-discriminating plastic scintillators

Lithium-loaded organic plastic scintillators combine sensitivity to γ rays with the ability to detect both fast and slow neutrons, making them valuable for applications in nuclear security and in basic nuclear and particle physics. The goal of this work is to characterize the neutron response of two custom lithium-loaded organic plastic scintillators developed at Lawrence Livermore National Laboratory. Both are ternary polystyrene-based formulations containing 1.5 wt.% 6 Li salts of isobutyric acid, but they differ in their primary and secondary dye compositions: one uses m-terphenyl as the primary fluor and with Exalite 404 as the wavelength shifter, whereas the other uses 2,5-diphenyloxazole (PPO) and 9,10-diphenyl-anthracene, respectively. The temporal response of the scintillators was measured via time-correlated single photon counting for γ-ray and neutron events. The proton light yield was measured using the double time-of-flight technique from 1.3 to 15 MeV at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. For the slow neutron response, an AmBe source moderated with polyethylene was used, and the light output from the 6 Li(n,α)t reaction was characterized. Differences in ionization quenching and temporal response were observed between the two materials with the PPO-containing scintillator exhibiting higher ionization quenching. These results provide performance benchmarks that can guide the design and optimization of future lithium-loaded plastic scintillators for use in basic science and applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Domain Size, Boundary, and Loading Conditions on Mechanical Properties of Amorphous Silica: A Reactive Molecular Dynamics Study

Mechanical properties are very important when choosing a material for a specific application. They help to determine the range of usefulness of a material, establish the service life, and classify and identify materials. The size effect on mechanical properties has been well established numerically and experimentally. However, the role of the size effect combined with boundary and loading conditions on mechanical properties remains unknown. In this paper, by using molecular dynamics (MD) simulations with the state-of-the-art ReaxFF force field, we study mechanical properties of amorphous silica (e.g., Young’s modulus, Poisson’s ratio) as a function of domain size, full-/semi-periodic boundary condition, and tensile/compressive loading. We found that the domain-size effect on Young’s modulus and Poisson’s ratio is much more significant in semi-periodic domains compared to full-periodic domains. The results, for the first time, revealed the bimodular and anisotropic nature of amorphous silica at the atomic level. We also defined a “safe zone” regarding the domain size, where the bulk properties of amorphous silica can be reproducible, while the computational cost and accuracy are in balance.

bimodular materials↗

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ultrathin Microporous Transport Layers: Implications for Low Catalyst Loadings, Thin Membranes, and High Current Density Operation for Proton Exchange Membrane Electrolysis

Porous transport layers (PTL) and their surface properties have the potential to improve the performance of proton exchange membrane water electrolyzers (PEMWE), which is imperative to reduce feedstock costs and lead to their widespread implementation. This work introduces a novel generation of titanium microporous layers (MPLs) with ultra-low thicknesses of approx. 20 um which reduces raw material costs. They also feature advanced interfacial properties tailored to maximize catalyst utilization at low Ir-loadings. The bulk morphology and surface properties of the hierarchically structured PTLs are assessed by X-ray tomographic microscopy. The low surface roughness of the MPL allows the use of thinner membranes since it minimizes possible deformations in the membrane. Cells containing the MPLs outperformed those containing state-of-the-art commercially available PTL materials by up to 100 mV at 7 A cm-2 in combination with low-loaded catalyst-coated membranes of 0.4 mgIr cm-2. Hydrogen crossover is also reduced, especially at low current densities, leading to a larger turndown ratio which can enable more cost-effective operating strategies. Finally, these rationally designed MPLs also lead to high catalyst utilization by overcoming the naturally occurring high in-plane resistance of low-loaded catalyst layers.

hydrogen crossover↗

Assessment of Vibration and Shock Loading Environments on Steels Used in Railroad Applications Considering Hydrogen Embrittlement

Studies that examine the combined effects of hydrogen and rail loading environments in the context of hydrogen embrittlement of steels have not been performed. Large-scale hydrogen storage requires either gaseous hydrogen stored in pressure vessels and tubing or liquid hydrogen in cryogenic, insulated tanks. Since the focus of this study is on steels, we examine the influence of hydrogen on stainless steel used for high pressure tubing and cryogenic tanks and Cr-Mo steel liners used in gaseous pressure vessels. Literature studies show that despite hydrogen degradation, these steels can be used effectively and safely if the stresses are managed. The shock and vibration environment on railcars present unique environments where stresses and loading rates can be high. A literature review was conducted to understand the accelerations experienced in rail by examining instrumented railcars of nuclear fuel casks. Hydrogen studies were examined that focused on steel pressure hardware with an emphasis on fatigue, fast loading rates, and low temperatures. A simplified fatigue assessment was performed to examine design cycles for three different hydrogen components: stainless steel tubing, stainless steel cryogenic tanks, and gaseous pressure vessels. The assessments were idealized and used bounding cases of accelerations in both normal rail conditions and coupling events. In normal shock and vibration environments when accelerations were less than 2 g, infinite design life was calculated. In extreme shock or coupling environments, finite design life was calculated which was shown to be dependent on unsupported lengths of pressure components. It was shown that adjusting the unsupported length can reduce the bending stress thereby increasing design life.

36 MATERIALS SCIENCE↗

Off-Design Load Analysis of sCO2 Bottoming Cycle for a Natural Gas Combined Cycle Power Plant with Carbon Capture

As an alternative to a steam cycle, a supercritical carbon dioxide (sCO2) power cycle can be considered. Able et. al performed an analysis of an sCO2 cycle in a 2x2-1 configuration; however, this study did not include carbon capture. Previous studies assumed an H-Frame turbine and added a solvent based 95% carbon capture system and performed a levelized cost of electricity (LCOE) optimization for the plant. Their results suggest a LCOE slightly better than when using a steam cycle. In the study, steam is still generated in the heat recovery sections for the solvent regeneration in the carbon capture stripper reboiler. H-Frame gas turbines are also assumed. This work starts with the optimal design from the mentioned work to analyze the off-design performance of the power plant from 100% down to 50% load. The main operational findings and plant-efficiency for off-load conditions while maintaining the target CO2 capture rate are presented. H-Frame gas turbine off-design performance and exhaust conditions to the heat recovery section are obtained from commercial software, Thermoflow®. The CO2 turbomachinery, heat exchangers and other unit operations are sized and implemented in an Aspen Plus® model. Using the gas turbine exhaust conditions as input, the sCO2 cycle is optimized by adjusting stream split ratios, sCO2 circulation flowrate and compressor speed for maximum efficiency. This is done while keeping the target 95% CO2 capture.

Chinen, Anderson Soares↗

Energy Equity Opportunities in Distributed Wind Hybrid Systems for Rural Loads

Distributed wind (DW) hybrid systems, or combinations of distributed energy resources with wind technologies, have the potential to provide energy equity benefits for rural loads. However, project developers and end-users do not understand these benefits well. This report outlines energy equity opportunities that result directly from DW-hybrid projects and proposes a framework that demonstrates how to consider equity in the DW-hybrid system, which can enhance existing resilience and valuation tools by incorporating a way to include equity considerations. Energy equity opportunities achievable with DW-hybrid systems for rural loads are defined by the core principles of energy justice for use in a proposed equity framework. As well, a catalog of equity resources, metrics, technology-agnostic frameworks, and best practices are linked in an attached Excel file. Electric cooperatives, technical assistance providers (including national laboratory and DOE staff), DW project developers, and technology providers can use this work to understand, evaluate, and define equitable outcomes for potential DW-hybrid projects.

17 WIND ENERGY↗

Super p-sulfur cathodes for quasi-solid-state lithium-sulfur-batteries

Lithium-Sulfur (Li-S) batteries have become a promising candidate to meet the current energy storage demand, with its natural abundance of materials, high theoretical capacity of 1672 mAhg-1, high energy density of 2600 Whkg-1, low cost and lower environmental impact. Sulfide based solid state electrolytes (SSEs) have received greater attention due to their higher ionic conductivity, compatible interface with sulfur-based cathodes, and lower grain boundary resistance. However, the interface between SSEs and cathodes has become a challenge in all solid-state Li-S batteries due to the rigidity of the participating surfaces. A hybrid electrolyte containing SSE coupled with a small amount of ionic liquid, was essential to improve the interface contact of the SSE with the electrodes. Coating-based cathodes were successfully fabricated using water-based carboxymethyl cellulose (CMC) solution and Styrene butadiene rubber (SBR) as the binder with low sulfur loading (0.70 mgcm-2) as well as high sulfur loading (4.0 mgcm-2). Solid-state composite powder-based cathodes pressed onto SSE (loading 4.0 mgcm-2) with enhanced electronic and ionic conductivity were fabricated with Super P: Sulfur (SP:S) and SSE. Ionic Liquids (IL) prepared using Lithium bis(trifluoromethyl sulfonyl)imide (LiTFSI) as salt, with premixed pyrrolidinium bis(trifluoromethyl sulfonyl)imide (PYR) as solvent and 1,3-dioxolane (DOL) as diluent were used to wet both SSE-electrode interfaces. The effect of IL dilution, co-solvent amount, LiTFSI concentration, C rate at which the batteries are tested and the effect of SSE inside the cathode, were systematically studied and optimized to develop a quasi-solid-state electrolyte Li-S battery (QSSLSB) with higher capacity retention and cyclability. LiTFSI (2M) dissolved in PYR:DOL(1:1) found to be optimum IL combination for low sulfur loading QSSLSBs reaching 500 mAh/g after 100 cycles while LiTFSI (3M) in PYR:DOL(1:3) was the optimum IL concentration for higher loading QSSLSBs reaching 400 mAh/g after 100 cycles. This work reports promising results of QSSLSB based on novel Li6PS5F0.5Cl0.5 Li-argyrodite solid-state electrolyte (SSE) with minute amount of IL, Super P-Sulfur (SP:S) cathode, and Li-anode. It also offers a new insight into the intimate interfacial contacts between the SSE and carbon-sulfur cathodes, which will be critical for improved electrochemical performance of quasi-solid-state lithium-sulfur batteries with high sulfur loading in the future.

25 ENERGY STORAGE↗

Steady state thermo-mechanics and material property definition framework for analyzing DCLL blanket in the fusion nuclear science facility

In this work, a thermo-mechanics model that relies on creating the material property definition framework (MPDF) and multiphysics coupling of the heat transfer and the solid mechanics modules is developed to determine the structural integrity of the recently designed dual cooled lead lithium (DCLL) inboard blanket (IB) for the Fusion Nuclear Science Facility under steady state loads. The MPDF is called to supply fusion relevant neutron irradiation and temperature induced changes in material properties during multiphysics finite element runs, and PbLi temperature profiles are used to approximate Magnetohydrodynamics effect and the nuclear volumetric heating on the PbLi. Neutron irradiation and temperature induced reduction of the yield and ultimate strengths of F82H steel at the first wall (FW) are quantified for one year. A blanket in an assembly with gaps between blanket sectors and another blanket in an assembly with no gaps between blanket sectors, both exposed to radiation damage that lasted for one year are analyzed. Analysis using the elastic ITER structural design criteria for in-vessel components (ITER SDC-IC) design rules and a linear isotropic-hardening-type elastoplastic material model are used where most appropriate. The IB blanket with gaps between blanket sectors will withstand the steady state combined thermal and coolant loads for one year operational period but will fail if no gaps are allowed between blanket sectors. It is recommended that a gap of about 7.62 mm should be provided between IB blanket sectors during assembly which would close up during service, stop neutron streaming, reduce stresses and reduce bending of the FW into the scrape-off layer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In-situ observations of cyclic deformation in an extruded Mg-2Nd-1Y-0.1Zr-0.1Ca alloy

In this study, the evolution of deformation mechanisms during cyclic loading in an extruded, solution-treated Mg–2Nd–1Y–0.1Zr–0.1Ca alloy was investigated using a combination of in-situ loading, scanning electron microscopy (SEM), electron backscatter diffraction (EBSD), and focused ion beam (FIB) nanofabrication. The initial microstructure exhibited a random crystallographic texture with no preferred grain orientation. Flat, rectangular dog-bone specimens were subjected to load-controlled, fully reversed fatigue for 50 cycles, during which the same region was sequentially mapped to track microstructural changes. After 10 cycles of loading deformation twins were observed. During tensile reloading detwinning or narrowing of those twinned regions occurred. After 20 cycles, detwinning ceased and residual twins remained in the material. SEM imaging revealed numerous surface slip traces after cyclic loading. EBSD-assisted slip trace analysis identified the activation of prismatic and pyramidal < c+a> slip systems during low-cycle fatigue. Site-specific scanning transmission electron microscopy (STEM) further revealed that deformation was also accommodated by basal < a> slip and the dissociation of < c+a> dislocations. Center-of-symmetry (COS) analysis confirmed that the dissociation of < c+a> dislocations resulted in the formation of I₁ intrinsic stacking faults after cyclic loading. These findings provide new insights into the complex interplay of dislocation mechanisms governing fatigue deformation in rare-earth-containing Mg alloys.

Cyclic deformation↗

Probabilistic impact of electricity tariffs on distribution grids considering adoption of solar and storage technologies

This study models the role of electricity tariffs on the long-term adoption of photovoltaic and storage technologies as well as the consequent impact on the distribution grid. An adoption model that captures the economic rationality of tariff-driven investments and considers the stochastic nature of individual consumers’ decisions is proposed. This model is then combined with a probabilistic load flow to evaluate the long-term impacts of the adoption on the voltage profiles of the distribution grid. To illustrate the methodology, different components of the electricity tariffs, including solar compensation mechanisms and time differentiation of Time-of-Use (ToU) rates, are evaluated, using a case study involving a section of a medium-voltage network with 118 nodes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Three-dimensional continuum point cloud method for large deformation and its verification

This study presents a strong form based meshfree collocation method, which is named Continuum Point Cloud Method, to solve nonlinear field equations derived from classical mechanics for deformed bodies in three-dimensional Euclidean space. The method and its implementation are benchmarked against a nonlinear vector field using manufactured solutions. The analysis of mechanical fields firstly focuses on the study of St. Venant Kirchhoff and compressible neo-Hookean materials. Results for various initial boundary value problems are presented, including benchmark cases involving unidirectional tension and simple shear. Subsequently, the study concludes with an analysis of a displacement-controlled simulation of a compressible neo-Hookean material, specifically a bar that is pulled to 50% of its original length and rotated 90°. The pure tension case yields a 1.5% error in displacement between computed and expected values and a combined tension and torsion loading case provides further insight into material behavior under complex loading conditions. The resulting normal axial and transverse stress-strain curves are also presented. Lastly, the consistency and robustness of the proposed nonlinear numerical schemes are successfully demonstrated through various numerical experiments.

Compressible neo-Hookean materials↗

Enabling fast charging of lithium-ion batteries through secondary-/dual- pore network: Part II - numerical model

To increase the market share of electric vehicles, it is desirable to reduce the battery charge times, which are significantly limited by poor electrolyte transport. A high rate charging is achievable by using expensive and low energy density cells with thin electrodes. For higher energy density cells, new electrolytes with improved conductivity and diffusivity and/or electrodes with advanced architecture are required to boost the electrolyte transport, leading to a more uniform utilization of active materials. In our previous work, an analytical model was developed to investigate the effect of secondary pore network (SPN) on electrolyte transport and the configuration of SPN was optimized by enforcing equal characteristic diffusion times in through-plane and in-plane directions. Here, to evaluate the effect of SPN on the fast-charging capability of lithium-ion batteries, a 2D physics-based electrochemical model is developed with SPN in either one or both electrodes. Additionally, the effect of SPN on cell energy density and lithium plating is investigated for cells with different loadings and electrode porosities. Combining SPN with elevated charging temperatures, the model predicts that the volumetric discharge energy density of a 3 mA h/cm2 cell can reach 270 Wh/L after a 6C constant-current charging.

25 ENERGY STORAGE↗

Enhancing heat pump water heater performance with embedded phase change materials thermal energy storage: First hour rating improvement and demand response operation

The increasing global emphasis on energy efficiency and sustainability has put heat pump water heaters (HPWHs) in the spotlight as an energy-efficient alternative to traditional water heating systems. However, their widespread adoption is limited by challenges such as insufficient First Hour Rating (FHR), suboptimal control mechanisms, and limited flexibility for demand response operations. Here, to address these limitations, this study proposes an innovative HPWH system integrated with embedded phase change material (PCM)-based thermal energy storage (TES). The research introduces a novel design and control strategy that leverages optimized PCM integration to enhance thermal storage capacity, improve hot water delivery during peak demand, and increase load-shifting potential. A combination of system modeling, performance simulation, and demand response control strategy evaluation was employed to quantify the benefits of PCM integration. Results demonstrate that the proposed PCM-TES HPWH system significantly enhances FHR, with an optimal 7.0 lb. of PCM increasing FHR by over 26 %—from 62 to 78 gal—for a standard 50-gal HPWH. Additionally, under advanced demand response operation using a preheat strategy, the system reduces the percentage of control temperature out-of-band time from 65 % (conventional HPWH) to just 11.6 %, enabling a more stable and efficient hot water supply. This research contributes a novel PCM-embedded HPWH design and control framework that addresses both performance and grid-interactivity challenges. The findings offer a viable pathway to enhancing the operational efficiency, flexibility, and grid responsiveness of residential water heating systems.

Demand response control↗

A New Hybrid Quantum-Classical Algorithm for Solving the Unit Commitment Problem

Solving problems related to planning and operations of large-scale power systems is challenging on classical computers due to their inherent nature as mixed-integer and nonlinear problems. Quantum computing provides new avenues to approach these problems. We develop a hybrid quantum-classical algorithm for the Unit Commitment (UC) problem in power systems which aims at minimizing the total cost while optimally allocating generating units to meet the hourly demand of the power loads. The hybrid algorithm combines a variational quantum algorithm (VQA) with a classical Benders-type heuristic. The resulting algorithm computes approximate solutions to UC in three stages: i) a collection of UC vectors capable meeting the power demand with lowest possible operating costs is generated based on VQA; ii) a classical sequential least squares programming (SLSQP) routine is leveraged to find the optimal power level corresponding to a predetermined number of candidate vectors; iii) in the last stage, the approximate solution of UC along with generating units power level combination is given. To demonstrate the effectiveness of the presented method, three different systems with 3 generating units, 10 generating units, and 26 generating units were tested for different time periods. In addition, convergence of the hybrid quantum-classical algorithm for select time periods is proven out on IonQ's Forte system.

Aboumrad, Willie [IonQ, Inc]↗