Surface Processes Control the Fate of Reactive Oxidants Generated by Electrochemical Activation of Hydrogen Peroxide on Stainless-Steel Electrodes

Low-cost stainless-steel electrodes can activate hydrogen peroxide (H 2 O 2 ) by converting it into a hydroxyl radical ( • OH) and other reactive oxidants. At an applied potential of +0.020 V, the stainless-steel electrode produced • OH with a yield that was over an order of magnitude higher than that reported for other systems that employ iron oxides as catalysts under circumneutral pH conditions. Decreasing the applied potential at pH 8 and 9 enhanced the rate of H 2 O 2 loss by shifting the process to a reaction mechanism that resulted in the formation of an Fe(IV) species. Significant metal leaching was only observed under acidic pH conditions (i.e., at pH <6), with the release of dissolved Fe and Cr occurring as the thickness of the passivation layer decreased. Despite the relatively high yield of • OH production under circumneutral pH conditions, most of the oxidants were scavenged by the electrode surface when contaminant concentrations comparable to those expected in drinking water sources were tested. The stainless-steel electrode efficiently removed trace organic contaminants from an authentic surface water sample without contaminating the water with Fe and Cr. With further development, stainless-steel electrodes could provide a cost-effective alternative to other H 2 O 2 activation processes, such as those by ultraviolet light.

42 ENGINEERING↗

The diversity of aluminum-based drinking water treatment residuals for use in environmental remediation

Drinking water treatment residuals (DWTRs) are complex mixtures of organic and inorganic phases generally disposed of as waste materials. However, their strong sorptive properties could be further exploited to immobilize contaminants. To characterize these materials, we applied a range of analytical techniques to a set of aluminum-based DWTRs. Here we determined surface areas, elemental compositions using CHNS analysis and X-ray fluorescence (XRF), performed thermogravimetric analyses paired with mass spectrometry (TGA-MS), and used synchrotron-based methods: X-ray diffraction (XRD) and X-ray absorption spectroscopy (XAS). Elemental analyses and specific surface area measurements – that vary between 7.23 ± 0.03 and 197.6 ± 0.9 m 2 g –1 – indicate that non-coagulant additives must play an important role in controlling sorption. High resolution powder XRD reveals the presence of only a few crystalline minerals mostly derived from source waters or additives. Fe was detected by XRF in all samples, whereas Mn was present in significant levels in samples with potassium permanganate as additive. The chemical speciation of these elements was characterized by performing spectral decompositions of XAS spectra. The spectral features of Fe are consistent with iron(III) oxides/hydroxides and structural iron in clays. On the other hand, Mn is predominantly present under its reduced form, Mn(II).

54 ENVIRONMENTAL SCIENCES↗

Advanced Test Reactor Safety Basis Update for Gas-Cooled Experiments

The Advanced Test Reactor (ATR) supports neutron irradiation of several types of experiments. One such experiment type is referred to as a gas leadout. Gas leadout experiments actively flow gas through the experiment which allows for active temperature control. It also allows for in-situ data of the experiment. For example, fission gas migration through a fuel sample can be monitored via activity of the sweep gas. Historically, ex-pile equipment and fission product monitors were housed in shielded ATR cubicles. Due to other facility updates, cubicle space is no longer available for gas leadout experiment equipment. To support continued operation of gas leadout experiments, ATR completed a safety basis update that supports a new housing for leadout equipment that may process potentially contaminated gas. In addition to the structure and associated equipment, technical safety requirements regarding handling and storage of experiments needed to be revised to support fueled gas leadout experiments and associated outage configurations. The safety basis update addressed the full lifecycle of these experiments, including experiment movement and interim storage, and credible abnormal events such as failures or leaks in contaminated gas tubing in occupied areas. This paper discusses the completed analyses performed to support the safety basis update associated with gas leadout experiments, including thermal-hydraulic evaluation, probabilistic analysis, and dose consequence analyses.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A High-Fidelity Modeling Tool to Support the Design of Oxy-Combustors for Direct-Fired Supercritical CO2 Cycles

The challenge in the design of oxy-combustors for direct-fired supercritical CO 2 (sCO 2 ) cycles is in addressing disparate performance metrics and objectives. Key design parameters to consider include, among others, injector design for mixing and flame stability, split of recycled CO 2 diluent between injectors and cooling films, target flame temperatures to control noncondensable products, and strategies to inject the diluent CO 2 for film cooling and thermal control. In order to support novel oxy-combustor designs, a high-fidelity yet numerically efficient modeling framework based on the CRUNCH CFD® flow solver is presented, featuring key physics-based submodels relevant in this regime. For computational efficiency in modeling large kinetic sets, a flamelet/progress variable (FPV) based tabulated-chemistry approach is utilized featuring a three-stream extension to allow for the simulation of the CO 2 film cooling stream in addition to the fuel and oxidizer streams. Finite rate chemistry effects are modeled in terms of multiple progress variables for the primary flame as well as for slower-evolving chemical species such as NO x and SO x contaminants. Real fluid effects are modeled using advanced equations of states. The predictive capabilities of this computationally tractable design support tool are demonstrated on a conceptual injector design for an oxy-combustor operating near 30 MPa. Simulations results provide quantitative feedback on the effectiveness of the film cooling as well as the level of contaminants (CO, NO, and N) in the exhaust due to impurities entering from the injectors. These results indicate that this framework would be a useful tool for refining and optimizing the oxy-combustor designs as well as risk mitigation analyses.

Engineering↗

Demethylation or Sorption? The Fate of Methylmercury in the Presence of Manganese Dioxide

Manganese oxide (MnO 2 ) amendments to mercury (Hg)-contaminated sediment have been shown to decrease methylmercury (MeHg) concentrations in sediment porewater. In the absence of solid-phase MeHg measurements, it is unclear whether the decreased porewater concentrations are due to inhibition of methylation, adsorption of the MeHg to the MnO 2 , demethylation of MeHg catalyzed by the MnO 2 , or some combination of these mechanisms. We conducted controlled laboratory experiments to determine whether MeHg losses from solution in the presence of amorphous MnO 2 are due to sorption or demethylation. In this work, we quantified MeHg in the dissolved phase and solid phase and found that no demethylation occurred. We used batch and isotherm experiments to determine MeHg sorption efficiency to MnO 2 in a variety of solutions with varying ionic strength and dissolved organic matter (DOM) concentration. Isotherms over an initial concentration range of 5–500 ng/L of MeHg showed no saturation effects. Increasing ionic strength from 0.012 M to 0.1 M produced relatively minor decreases in MeHg sorption. Increasing DOM concentrations from 0.64 to 16.4 mg C/L yielded substantial decreases in MeHg sorption. Under the experimental conditions, MnO2 is a less efficient MeHg sorbent compared to other sorbent materials, such as Thiol-SAMMS®, activated carbon, and biochar.

42 ENGINEERING↗

Defining a compact dry cooler design to reduce LCOE contribution in a CSP facility

Concentrating solar power (CSP), when coupled with a supercritical carbon dioxide (sCO 2 ) power cycle and sensible heat storage, presents a renewable and clean alternative for utility-scale power generation. However, in order to be competitive in the current and future markets, CSP facilities must limit their levelized cost of electricity (LCOE) by minimizing capital costs and reducing operating costs over the lifetime of the plant. Targeting this goal, this study investigates the LCOE impact of the power cycle pre-cooler. This study considers a compact dry cooler with micro-channel technology on the CO 2 side and formed fin geometry on the air side, using directly-coupled centrifugal fans and a transition duct to improve air distribution across the fins as well as protect the fins from contaminants which may cause blockage, soiling, fouling, and damage. In an effort to better understand the dry cooler impact on LCOE, a sensitivity study was conducted using various combinations of end-to-end approach temperatures, air-side pressure drop values, CO 2 -side pressure drop values, fan types, cooler turndown control schemes, cooler module sizes, and design-point ambient temperatures. Furthemore, off-design cycle performance data was calculated for each dry cooler design using NPSS simulation software; cycle performance data were then input to System Advisor Model (SAM) along with the associated capital costs for LCOE prediction of a 100 MW system over a 30 year plant lifetime. Results of this study show the LCOE is most sensitive to air-side performance, followed by heat transfer effectiveness and capital cost. It was found that a power cycle with a mid- to high-performance dry cooler will produce the most competitive power-production costs. Designing at the extreme ends for approach temperature (or effectiveness), design-point ambient temperature, and compactness (footprint) produce higher LCOE values; mid-range values for these parameters balance performance, operating costs, and associated capital cost to optimize LCOE.

14 SOLAR ENERGY↗

Approaches for effective negative pressure isolation space control to minimize airborne transmission of contaminants in residential homes

Controlling airborne transmission of contaminants including respired viruses such as SARS-CoV-2 is necessary to protect occupants living in the same house with a contagious person. The effectiveness of interventions requiring minor efforts that create a negative pressure isolation zone (IZ) for a contagious person has yet to be systematically tested for residential homes. In this study, ASHRAE Standard 170, which offers guidance for negative pressure isolation space control in healthcare facilities, was used in developing practical and attainable recommendations for residential single-family homes. The relative effectiveness of several control strategies was evaluated through experimentally conducting 17 different test cases in a manufactured single-family house laboratory. These cases were designed based on various heating, ventilation and air-conditioning (HVAC) operating scenarios, intervention measures including closing the IZ door and/or sealing over supply and return air grilles in the IZ, and utilization of bathroom exhaust or portable window fans for pressure control. Four out of 17 test cases were identified as having the potential for strong containment with adequate depressurization in the IZ. The most effective IZ depressurization was achieved through continuously operating the exhaust fan in the bathroom attached to the IZ, by installing a portable window fan that extracted air out of the IZ, and a portable room air conditioner with the AC unit exhaust duct installed in one of the IZ windows.

Construction & Building Technology↗

Contamination control and assay results for the Majorana Demonstrator ultra clean components

The Majorana Demonstrator is a neutrinoless double beta decay experiment utilizing enriched Ge-76 detectors in 2 separate modules inside of a common solid shield at the Sanford Underground Research Facility. The Demonstrator has utilized world leading assay sensitivities to develop clean materials and processes for producing ultra-pure copper and plastic components. This experiment is now operating, and initial data provide new insights into the success of cleaning and processing. Post production copper assays after the completion of Module 1 showed an increase in U and Th contamination in finished parts compared to starting bulk material. A revised cleaning method and additional round of surface contamination studies prior to Module 2 construction have provided evidence that more rigorous process control can reduce surface contamination. In conclusion, this article describes the assay results and discuss further studies to take advantage of assay capabilities for the purpose of maintaining ultra clean fabrication and process design.

36 MATERIALS SCIENCE↗

EPA and Idaho National Laboratory create first of its scale

Advancing the science and engineering of decontaminating water distribution systems and safely disposing of high-volumes of contaminated water are high priorities for the EPA. To help address these science gaps, EPA homeland security researchers have developed the first-of-its-scale Water Security Test Bed (WSTB). Water is an important component of everyday life. We rely on safe, clean water for our health and the health of the environment. Protecting this vital resource is critical to living safely and securely. The U.S. Environmental Protection Agency is responsible for working with water utilities to protect water systems from contamination and to clean up systems that become contaminated. Purposeful or inadvertent distribution system contamination can result in large amounts of infrastructure and water that must be cleaned. Water distribution systems contamination can be caused by, for example, natural disasters such as Superstorm Sandy or by individuals hoping to cause harm. The WSTB, constructed at the Department of Energy’s (DOE) Idaho National Laboratory, replicates a section of a typical municipal drinking water system including a piping system with roughly 445 feet of pipe and two fire hydrants laid out in an “L” shape using 40-year-old, eight-inch cement mortar lined, ductile iron pipes, excavated after twenty years of use for water conveyance. Researchers built the WSTB above ground for easy access during experiments, and to facilitate fast leak detection. Over the next several years, EPA and partner researchers will conduct experiments using simulants of various biological, chemical, and radioactive materials that simulate high toxic versions of these agents. At this “full” sized system, researchers will demonstrate approaches to contamination detection, sensor and model testing, infrastructure decontamination, water treatment and cyber testing developed at lab and pilot scale. Researchers are also able to verify if laboratory results that were effective in controlled conditions are as effective in full-scale testing. Having the ability to conduct bench scale studies in a real world setting can help address specific research gaps, and help water researchers understand conditions in which real world drinking water systems operate.

54 ENVIRONMENTAL SCIENCES↗

Probing unintentional Fe impurity incorporation in MOCVD homoepitaxy GaN: Toward GaN vertical power devices

Unintentional impurity incorporation in GaN drift layers represents a challenging issue that can limit their potential performance in vertical power devices. In this paper, we focus on studying the origins of Fe impurity incorporation in metal-organic chemical vapor deposition (MOCVD) grown GaN materials. Acting as a compensator in n-type GaN drift layers, Fe impurities can reduce the electron mobility in GaN and limit the lowest controllable doping level. Two sources, the sample cleaning process and growth susceptor, were identified as the main mechanisms of Fe incorporation in the MOCVD GaN growth process. It was found that solvent cleaning of the wafer can introduce significant Fe contamination at the growth interface, which would slowly be incorporated into the GaN epilayer, thus causing background Fe impurity as high as 10 17 cm -3 level. Moreover, the Fe impurity in the coating material on the susceptor can introduce additional Fe impurity during the growth process. Our studies revealed that the Fe impurity level could be significantly suppressed by more than two orders when an alternative cleaning process was used and the susceptor surface was fully covered by substrates. Characterization of the Fe impurity concentrations was performed via secondary ion mass spectrometry. The trap level (E C - 0.57) eV from deep-level transient spectroscopy that had previously been attributed to Fe confirmed the carrier compensation effect from Fe. Room temperature Hall mobility as high as 1007 cm 2 /V s was achieved on the MOCVD grown low-Fe GaN. Results from this work will provide guidance for achieving high purity GaN toward high performance GaN vertical power devices.

42 ENGINEERING↗

Smart Ventilation Controls for Occupancy and Auxiliary Fan Use Across U.S. Climates

Smart Ventilation has been developed as a way to reduce the energy associated with ventilation by changing when ventilation happens and how much ventilation occurs at any given time. In high performance buildings with low envelope and appliance related loads, ventilation is becoming a bigger part of the total building energy use and needs to be addressed if performance targets are to be met. This work explores the development and performance of smart ventilation controls based on occupancy and auxiliary fan operation that provide annual dwelling unit ventilation equivalence to ASHRAE Standard 62.2-2016. A prototype high performance home compliant with U.S. DOE Building America Zero Energy Ready program requirements was simulated using the REGCAP tool with and without smart controls across 15 U.S. DOE climate zones. Balanced and unbalanced IAQ fans were independently simulated, and all smart controlled fans had airflows double the reference 62.2-2016 airflow. Three idealized occupancy patterns were examined: 1st shift (a typical daily work/school absence), an extended 1st shift with more time spent out of the home evenings and weekends and 3rd shift (night work). The Occupancy controller turns the IAQ fan off during unoccupied periods, and it resumes ventilation upon their return. While unoccupied, contaminants are allowed to accumulate in the space, because occupants are not exposed to these contaminants. When occupants return home, they are exposed to these higher contaminant concentrations, and the controller increases the ventilation rate sufficiently to ensure equivalence with a continuous IAQ fan. Accounting for pollutant emissions that occur during unoccupied periods (as required by ASHRAE 62.2-2016), sharply distinguishes our occupancy controls from past Demand Controlled Ventilation systems. This new accounting method results in equivalent contaminant exposure, as well as lower reductions in average ventilation rates and lower energy savings. Smart controls were demonstrated that saved HVAC energy (i.e., avoided heating/cooling load, as well as fan energy)—averaging between 6 and 46% of ventilation-related energy use depending on the control strategy and occupancy pattern assumptions. The greatest savings were in the combined Auxiliary Fan + Occupancy control. Energy savings increased with climate heating demand and longer unoccupied time periods. The 3rd shift occupancy pattern had better performance, due to the thermal benefit of reducing the ventilation rate during the cold nighttime hours. This same effect provided a cooling energy benefit in hotter locations for the 1st shift. Overall, savings from occupancy-based smart controls were low, because of the recovery period required after occupants return home, during which the airflow is double the 62.2 reference. This recovery is required to maintain equivalence with the ASHRAE standard. Occupancy-based control performance was improved when combined with sensing auxiliary fans and when providing a pre-occupancy flush out of one- or two-hours. Performance was similarly improved if the ASHRAE Standard were to recognize that pollutant emissions are lower during unoccupied periods, iii allowing a lower target ventilation rate during unoccupied periods (not currently in the standard) (see Full vs. Half AEQ in this report). Finally, over-sized unbalanced fans that are cycled on-and-off by a smart controller (or timer) were found to substantially increase annual average air exchange and energy use relative to a continuous unbalanced fan due to the effects of superposition with natural infiltration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Porous Iron Electrodes Reduce Energy Consumption During Electrocoagulation of a Virus Surrogate: Insights into Performance Enhancements Using Three-Dimensional Neutron Computed Tomography

Electrocoagulation has attracted significant attention as an alternative to conventional chemical coagulation because it is capable of removing a wide range of contaminants and has several potential advantages. In contrast to most electrocoagulation research that has been performed with nonporous electrodes, in this study, we demonstrate energy-efficient iron electrocoagulation using porous electrodes. In batch operation, investigation of the external pore structures through optical microscopy suggested that a low porosity electrode with sparse connection between pores may lead to mechanical failure of the pore network during electrolysis, whereas a high porosity electrode is vulnerable to pore clogging. Electrodes with intermediate porosity, instead, only suffered a moderate surface deposition, leading to electrical energy savings of 21% and 36% in terms of electrocoagulant delivery and unit log virus reduction, respectively. Neutron computed tomography revealed the critical role of electrode porosity in utilizing the electrode’s internal surface for electrodissolution and effective delivery of electrocoagulant to the bulk. Energy savings of up to 88% in short-term operation were obtained with porous electrodes in a continuous flow-through system. Further investigation on the impact of current density and porosity in long-term operation is desired as well as the capital cost of porous electrodes.

42 ENGINEERING↗

Wire Arc Additive Manufacturing Final Report for the Wire-Based AM Focused Exchange

This feasibility study demonstrates the ability to additively manufacture 3D parts from reactive metal alloys using robotically controlled wire arc additive manufacturing (WAAM). Experiments consisted of developing WAAM welding parameters and performing robotic welding inside a controlled atmosphere purge box that was specifically built for this project. Purge atmospheres with varying levels of oxygen were created to determine minimum purge requirements for WAAM builds in order to build components without significant uptake of oxygen or nitrogen. Weld parameters were successfully developed for a titanium alloy (Ti-6-4) and tantalum, both being very sensitive to atmospheric contamination during welding. WAAM builds were made from Ti-6-4, Ta, and also 308L stainless steel to relate back to previous results for 308L WAAM studies performed in air. Oxygen purge levels varied from 1000 ppm to 1 ppm, and were further compared to builds made at atmospheric levels of O 2 (21%). Results showed significant uptake of oxygen and nitrogen for all three metals for WAAM parts built outside the inert atmosphere box, where only shielding gas from the welding torch was used as protection. However, considerable reduction of oxygen and nitrogen uptake, in all three metals, was observed even for moderate purge levels of 1000 ppm O 2 in the box. Additional purging reduced oxygen and nitrogen uptake further and was shown to be metal dependent where Ta and Ti-6-4 were more sensitive to nitrogen uptake than oxygen uptake. Guidelines for the measured O 2 content of WAAM purge atmospheres were created as follows: 900 ppm for 308L SS, 130 ppm for Ti-6-4, and 40 ppm for Ta. These purge levels produced nitrogen and oxygen contents of the build similar to the wire composition and within the allowable specifications for these metals.

36 MATERIALS SCIENCE↗

Controlled dehumidification to extract clean water from a multicomponent gaseous mixture of organic contaminants

Rapid expansion of the unconventional oil and gas extraction has increased American energy independence, but also led to increased production of large amounts of contaminated water. Wastewater from the oil and gas industry contains a wide range of contaminants. Injecting such contaminated water into disposal wells or discharging it to the environment jeopardizes freshwater resources. Conventional and membrane-based wastewater treatment techniques are often not effective choices to treat highly contaminated wastewater; however, a suitable way to remove contaminants from wastewater is to selectively separate water in a process analogous to humidification-dehumidification (HDH). Only a few studies have investigated the use of HDH for wastewater treatment. In this study, a novel HDH system is introduced for treating highly contaminated water, such as oil and gas flowback and produced water. In this HDH process, a non-condensable gas, such as air, mixes with wastewater vapor to facilitate the separation of contaminants. As a result, clean water condenses from the multicomponent gaseous mixture while air carries organic contaminants out of the dehumidification section. A laboratory apparatus was constructed and experiments were performed to investigate the HDH process for wastewater treatment and to study the effects of flow dynamics including air flow rate on the composition of treated water. Different contaminants including benzene, toluene, 2-propanol and 2-butoxyethanol were tested. Experimental results showed that the system can be successfully applied for removing volatile and/or toxic organic contaminants from wastewater. A representative multicomponent mixture of fracking wastewater was successfully treated using the experimental setup and clean water with quality of 98.3% was obtained. It was revealed that increasing the air-to-vapor mass ratio improves purity of treated water. Quantitative analysis showed that by increasing the air-to-vapor mass ratio from 0.6 to 5.9, the fraction of separated 2-propanol through the air was improved from 43% to more than 96% of the initial amount. ASPEN software was employed to simulate equilibrium conditions. Finally, experimental results were observed to have lower mass fraction of residual contaminant in the treated water compared to equilibrium state.

42 ENGINEERING↗

EMSL Community Science Campaign Meeting: Critical Minerals and Materials - Rhizo Critical Campaign Breakout Session Report Summary

The “Critical Minerals Biogeochemistry in the Rhizosphere – Ultramafic Soils (Rhizo Critical)” campaign breakout (BO) session was organized to identify major knowledge gaps and fundamental research needs in rhizosphere microbiology and geochemistry that, if addressed, could transform our ability to recover critical minerals from ultramafic soil systems. We sought to identify significant challenges that must be surmounted in the pursuit of deeper science knowledge. Our ultimate goal is to understand this landscape well enough to identify and prioritize opportunities for EMSL to make the greatest impact with Environmental Transformations and Interactions (ETI) science area research campaigns focused on the biogeochemical processes controlling the behavior of critical minerals and materials in the rhizosphere. The increasing demand for critical materials and minerals (CMM) in the U.S. has heightened interest in low-grade ores with much attention on ultramafic soils, which contain valuable metals such as nickel (Ni), chromium (Cr), manganese, cobalt (Co), and copper (Lee et al., 2025; DOE CMM Report, 2023) used in advanced battery, magnet, wiring and wind turbines, and stainless steel technologies. Metal hyperaccumulating plants grown in ultramafic soils can extract economically valuable concentrations of CMMs through the process of phytomining. This technology has evolved from phytoremediation, which involves using plants to cleanse contaminated environments by removing, detoxifying, or stabilizing pollutants like metals and organic compounds. Hyperaccumulator plants are capable of storing metals in their living tissues at concentrations hundreds to thousands of times higher than those found in 'normal' plants. For instance, while the average concentration of Ni in the dry matter of plants growing in typical soils is usually less than 5 µg g?¹, Ni hyperaccumulation is defined by concentrations exceeding 1,000 µg g?¹ (Corzo Remigio et al., 2020; Reeves et al., 2018). Phytomining research has primarily focused on Ni (Rylott and van der Ent, 2025), for which the U.S. has very limited conventional mines in operation. Most soils typically contain Ni concentrations ranging from 7 to 50 mg kg-1, whereas serpentine soils exhibit significantly higher levels, with Ni content often ranging between 700 and 8,000 mg kg-1 (Sobczyk et al., 2017). While more than 500 plant species in over 50 different families have been identified as Ni hyperaccumulators (Kidd et al., 2018), Ni phytomining (and phytominng in general) remains largely untested because most studies are short-term, small-scale, and conducted under simplified or artificially enriched conditions, so they fail to capture the low metal concentrations, environmental variability, and management constraints that would be needed for a field-scale demonstration. Few hyperaccumulator species have been validated as true “metal crops,” and their biomass production, stress tolerance, and rooting characteristics are usually too poor to yield economically meaningful metal outputs. Critically, the basic mechanisms of metal uptake, transport, and sequestration, especially as shaped by belowground processes such as root exudation, rhizosphere chemistry, and root–microbe interactions that control metal mobility and bioavailability (Montreemuk et al., 2023; Kidd et al., 2018; Durand et al., 2023; Alford et al., 2010), are still only partially understood, and downstream metal recovery from biomass is rarely optimized. Because these limitations stem from gaps in fundamental knowledge rather than from a failure of the concept itself (Rylott and van der Ent, 2025; van der Ent et al., 2015), there is a strong need for basic science that dissects plant metal homeostasis, rhizosphere and microbial processes, and their integration with soil chemistry and process engineering to design more robust, scalable phytomining systems.

Ahkami, Amirhossein↗

History of Ultrasonic Inspection of High-Level Waste Tanks at SRS - 20220

The Liquid Waste Disposition Projects (LWDP) Structural Authority and Inspection Engineering Support Group has teamed with the Materials Science and Technology Non-destructive Evaluation Group of Savannah River National Laboratory (SRNL) to implement a comprehensive In-Service Inspection (ISI) program for the High-Level Waste (HLW) tanks in the sites tank farms. The purpose of this program is to demonstrate the structural and leak integrity of the tanks to maintain the function of waste containment throughout the desired service life. Four types of waste tanks were constructed at Savannah River Site (SRS) from 1951 thru 1981 to store radioactive nuclear waste from the separations process. The Type I, II and III are carbon steel cylindrical tanks with varying degrees of access to the side walls and very limited access to the tank bottom. The tanks contain 750,000 to 1.3 million gallons of waste and are buried or backfilled with soil. The tanks are 75'-85' in diameter and 24'-33' from tank bottom to the tank roof. Inspection of the HLW tanks is made difficult by radiation, contamination, and small access openings. Through the years these challenges have been overcome by progressive improvements to programs and equipment resulting in the sophisticated wall crawler Ultrasonic Testing (UT) technology of today. A formal inspection program was developed and put in service in 1972. UT thickness measurements were first made in 1967 and 1969 of selected waste tanks using an analog-type instrument to measure the thickness of the carbon steel walls. Routine inspections for thinning were performed from 1972-1985 and then discontinued because no thinning had been observed and this technique could not detect pitting or cracking. UT inspections resumed in 1994 using a sophisticated robotic wall crawler with UT technology capable of detecting thinning, cracking and pitting. The current program focuses on the newer Type III tanks that are used primarily for storage. The program was upgraded in 2003 to include selected regions of the tank wall, secondary wall and annulus floor on a 7 to 10-year frequency. The facility is currently in its third cycle of tank inspections. Thus far, there have been no reportable indications of service induced degradation. This result provides assurance that the chemistry control program has been effective at mitigating corrosion and that the tanks remain structurally sound even after more than 40 years of service. This paper will present the UT technology first used at SRS and the evolution to the current systems and their capabilities. Additionally, plans for equipment upgrades that will improve the extent of inspection will be discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nuclear Decontamination Evolution and Revolution - 20349

Decontamination, one of the oldest practices in the nuclear industry, is about to change. While no single approach to decontamination is appropriate in all situations, decontamination of highly contaminated surfaces is historically viewed as difficult and/or marginally effective and fixatives and strippable coatings are often called on to manage time sensitive contamination control issues. The deferral of proper decontamination can lead to accumulated concentrations of radioactive material increasing the risk of cross-contamination of workers and equipment while also increasing radiation levels, which further discourages decontamination. The results of the subject testing demonstrate that superior decontamination factors are readily achievable and the ALARA benefit of decontamination is viable through advanced decontamination technologies in conjunction with innovative application techniques. The collateral benefits will save countless radiological man-hours and personnel radiological exposure. The appropriate use of radiological decontamination techniques can prevent or limit the adverse effects of highly radioactive contamination in the work area. High levels of radiological contamination are typically associated with some of the most physically demanding work in the nuclear industry. Additionally, working in highly contaminated environments increases the risk of exposure to elevated levels of airborne radioactivity and radiation from the source term of the contamination, particularly in hard to reach areas or complex equipment. Veolia's Alaron Nuclear Services (Alaron), a fully integrated nuclear facility, has provided the nuclear industry waste treatment, consolidation, repackaging, and broad decontamination services for almost 35 years. In looking at solutions for its customers, as well as for their own facility, Alaron has recently collaborated with Environmental Alternatives, Inc. (EAI), which has provided innovative solutions addressing difficult nuclear decontamination and industrial cleaning challenges since 1989. This broad range of experience along with the products to support the work created an ideal partner for Alaron's needs at their facility. The benefits of collaboration were immediately recognizable to the management of both companies although the decontamination challenge was significant. Due to the nature of the services offered, contamination at the Alaron facility is routine. The recent decontamination experience at Alaron utilized an innovative surfactant process that quickly produces remarkably higher decontamination factors for both removable surface contamination and fixed contamination. Considering the time to decontaminate areas historically designated for high radiological hazard work, the results from this decontamination effort not only reduced contamination levels but also significantly lowered exposure rates in the working environment. The relative ease with which the surfactant is applied, combined with extraordinary decontamination test results, indicates the potential to alter current radiological work processes in a way that improves worker comfort, and removes radiological engineering barriers, allowing Alaron to complete complex radiological tasks more efficiently and effectively. In a series of two simple applications of the decontamination agent to contaminated high bay vertical surfaces, as well as a variety of horizontal and vertical surfaces with variable porousness and surface sealants, there was an overall reduction in removable contamination of approximately 73% with a reduction in area dose of approximately 93%. The results indicate additional reduction in fixed contamination with application of the surfactant. These values are much higher than experienced with more traditional decontamination agents. In conjunction with demonstrating EAI's surfactant on room surfaces, additional studies were conducted on complex geometry equipment including waste processing equipment, tools, and heavily contaminated parts normally handled from Alaron's customers. Evaluations were made with straight application of EAI's surfactant as well as adding additional techniques to the treatment which afforded revolutionary improvements in the levels of contamination removed. Successful decontamination with up to 95% reduction in removable contamination with just one application were demonstrated in several of the trials. This paper outlines the planned approach to use this technology, the variety of surfaces and equipment treated, and the results of the decontamination efforts. Furthermore, this paper discusses options for pretreatment of certain heavily contaminated equipment prior to employees handling and/or working with the equipment. The potential for dose saving and the reduced risk of cross-contamination with the added benefit of lower PPE requirements, produces an enormous potential for cost and time savings. Attendees will benefit from Alaron's experiences and more fully understand the capabilities of EAI's decontamination process. With the variety of contamination agents, forms and surfaces on which the technology was demonstrated, the information will be valuable to a broad cross-section of industry users. The significance of this report demonstrates superior decontamination factors are achievable utilizing the next evolution of decontamination technology and that the ALARA benefits of decontamination are available through advanced and modern decontamination efforts. The collateral benefits will save countless radiological man-hours and valuable personnel radiological exposure. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hydraulic Testing of the Lost Lake Aquifer Near Recovery Well RWM 8

Groundwater beneath the M-Area HWMF is contaminated with chlorinated ethenes including trichloroethylene (TCE) and tetrachloroethylene (PCE). SRS operates a network of recovery wells designed to hydraulically contain and capture the high concentration VOC plume in the Lost Lake Aquifer Zone (LLAZ) (Figure 1). The recovery wells are connected to the M-1 Air Stripper and the system is permitted by the South Carolina Department of Environmental Control (SCDHEC) to operate at a total flow of 610 gpm. RWM 8, which is one of ten operational recovery wells, has historically operated at a flow rate of approximately 40 gpm. RWM 8 was installed with four separate 10-ft screens that spanned the LLAZ with a continuous gravel pack spaced as shown in Figure 2. The three uppermost screens are located within the LLAZ whereas the deepest screen is located within the middle sand of the Crouch Branch Confining Unit (CBCU). Area Closure Projects (ACP) installed a permanent packer in May 2019 to isolate the lowest screen from the pump with the goal being to target the zone of highest concentration in the LLAZ. ACP expressed concern that a substantial portion of the flow from RWM 8 comes from the lower screen. With this screen isolated from service, flow from the well may be below the desired operational envelope for the well. The reconfiguration of RWM 8 presented an opportunity to re-evaluate the performance characteristics of the well. Following placement of the packer and relocation of the pump, the well was redeveloped. To assess the effects of eliminating the lower screen, a step-drawdown test was planned. The purpose of this test was to establish new baseline well performance properties including specific capacity, well efficiency, and well loss coefficients. Data from the step-drawdown testing was also used to estimate a maximum pumping rate for RWM 8 under the new configuration. The setup for the step-drawdown test facilitated a subsequent constant rate aquifer pumping test aimed at determining aquifer hydraulic properties. Properties estimated for the LLAZ included transmissivity and storativity. Following shutdown of RWM 8, recovery data were also collected and analyzed to estimate aquifer properties. This report discusses the hydrologic tests conducted following the reconfiguration of RWM 8. The information provided in this report may serve as input to subsequent updates to the groundwater flow and contaminant transport model for A/M Area.

42 ENGINEERING↗