Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control Allocation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

JAZ repressors of metabolic defense promote growth and reproductive fitness in Arabidopsis

Plant immune responses mediated by the hormone jasmonoyl-L-isoleucine (JA-Ile) are metabolically costly and often linked to reduced growth. Although it is known that JA-Ile activates defense responses by triggering the degradation of JASMONATE ZIM DOMAIN (JAZ) transcriptional repressor proteins, expansion of the JAZ gene family in vascular plants has hampered efforts to understand how this hormone impacts growth and other physiological tasks over the course of ontogeny. Here, we combined mutations within the 13-member Arabidopsis JAZ gene family to investigate the effects of chronic JAZ deficiency on growth, defense, and reproductive output. A higher-order mutant (jaz decuple, jazD) defective in 10 JAZ genes (JAZ1–7, -9, -10, and -13) exhibited robust resistance to insect herbivores and fungal pathogens, which was accompanied by slow vegetative growth and poor reproductive performance. Metabolic phenotypes of jazD discerned from global transcript and protein profiling were indicative of elevated carbon partitioning to amino acid-, protein-, and endoplasmic reticulum body-based defenses controlled by the JA-Ile and ethylene branches of immunity. Resource allocation to a strong defense sink in jazD leaves was associated with increased respiration and hallmarks of carbon starvation but no overt changes in photosynthetic rate. Depletion of the remaining JAZ repressors in jazD further exaggerated growth stunting, nearly abolished seed production and, under extreme conditions, caused spreading necrotic lesions and tissue death. Our results demonstrate that JAZ proteins promote growth and reproductive success at least in part by preventing catastrophic metabolic effects of an unrestrained immune response.

59 BASIC BIOLOGICAL SCIENCES↗

Root of the matter-Impacts of harvest frequency on soil C and nutrients in switchgrass

We evaluated how harvest frequency affected plant C allocation and soil-water nutrient concentrations in a switchgrass (Panicum virgatumL.) system on the Eastern Shore of Maryland, U.S.A. Switchgrass established in 2023 was harvested once (1Cut), twice (2Cut), or three times (3Cut) during the 2024 growing season to represent potential feedstock-management regimes for anaerobic digestion. Aboveground biomass was measured at each harvest, and root biomass distribution, root C stocks, and soil properties were assessed to 60 cm after the growing season. During 2025, rainfall-synchronized soil water collected with tension lysimeters was analyzed for dissolved inorganic nitrogen (DIN) and inorganic phosphate (Pi) concentrations.

09 BIOMASS FUELS↗

Enhancing Cloud Cybersecurity: Prescriptive Controls for Operational Technology

This whitepaper provides strategic insights and recommendations into security cloud-based solutions for electric utilities, encompassing operational technology (OT), virtual power plants (VPP), distributed energy resources (DERs), applications, networks, and data storage as they transition to and leverage cloud infrastructure through managed service providers (MSPs) and cloud service providers (CSPs). Principles derived from established frameworks serve as a foundation for best practices across cybersecurity projects and remove the constraints of settling on a single framework. For organizations that prefer not to integrate a specific framework altogether, elements of the proposed approach could be adopted or tailored to best fit defined requirements and expected functionalities. The Cirrus assessment, a utility cloud feasibility tool, and the roadmap it provides serve as a precursor to this paper, which seeks to be a valuable resource for defining next steps following cloud technology integration feasibility appraisal. With its comprehensive approach to adoption, the Cirrus framework offers strategic guidance on responsibly preparing for or deploying a utility cloud solution. The previously published whitepaper, “Use Case-Informed Framework for Utility Cloud Migration,” details the guiding strategy, research, and deployment of cloud solutions within electric and interconnected grid systems. Before implementing the controls suggested in this document, it is recommended that stakeholders complete Cirrus's cloud integration assessment and pair the results with their unique cybersecurity controls to form a comprehensive cloud-based utility cybersecurity plan. The Cirrus outcome will consider a series of future architectures for the grid before and after the energy transition and evaluate the arguments for and against cloud applications for each electric and interconnected grid layer. This document is a companion to the original whitepaper, "Use Case-Informed Framework for Utility Cloud Migration" to further identify and recommend security controls based on Cirrus’s cloud integration assessment output. The following whitepaper outlines the cybersecurity controls that secure cloud-service models pertinent to the electric sector using the predefined categories identify, protect, detect, and respond and recover. The objective is to outline prescriptive security controls based on the type of architecture and data stored in the cloud. The focus includes dissecting the shared responsibility model and elucidating what on-premises Infrastructure as a Service (IaaS), Platform as a Service (PaaS), and Software as a Service (SaaS) entail. A pivotal consideration in this context is allocating responsibility for foundational cybersecurity aspects—having used Cirrus for the cloud integration assessment. The ensuing controls detailed herein also represent a checklist of controls necessary for a secure cloud transition, equipping utilities with the knowledge to navigate this digital transformation with confidence and strategic foresight in a safe and responsible manner.

42 ENGINEERING↗

Hardware-Based Emulator with Deep Learning Model for Building Energy Control and Prediction Based on Occupancy Sensors’ Data

Heating, ventilation, and air conditioning (HVAC) is the largest source of residential energy consumption. Occupancy sensors’ data can be used for HVAC control since it indicates the number of people in the building. HVAC and sensors form a typical cyber-physical system (CPS). In this paper, we aim to build a hardware-based emulation platform to study the occupancy data’s features, which can be further extracted by using machine learning models. In particular, we propose two hardware-based emulators to investigate the use of wired/wireless communication interfaces for occupancy sensor-based building CPS control, and the use of deep learning to predict the building energy consumption with the sensor data. We hypothesize is that the building energy consumption may be predicted by using the occupancy data collected by the sensors, and question what type of prediction model should be used to accurately predict the energy load. Another hypothesis is that an in-lab hardware/software platform could be built to emulate the occupancy sensing process. The machine learning algorithms can then be used to analyze the energy load based on the sensing data. To test the emulator, the occupancy data from the sensors is used to predict energy consumption. The synchronization scheme between sensors and the HVAC server will be discussed. We have built two hardware/software emulation platforms to investigate the sensor/HVAC integration strategies, and used an enhanced deep learning model—which has sequence-to-sequence long short-term memory (Seq2Seq LSTM)—with an attention model to predict the building energy consumption with the preservation of the intrinsic patterns. Because the long-range temporal dependencies are captured, the Seq2Seq models may provide a higher accuracy by using LSTM architectures with encoder and decoder. Meanwhile, LSTMs can capture the temporal and spatial patterns of time series data. The attention model can highlight the most relevant input information in the energy prediction by allocating the attention weights. The communication overhead between the sensors and the HVAC control server can also be alleviated via the attention mechanism, which can automatically ignore the irrelevant information and amplify the relevant information during CNN training. Our experiments and performance analysis show that, compared with the traditional LSTM neural network, the performance of the proposed method has a 30% higher prediction accuracy.

Ye, Zhijing↗

Bridging Control and Deployment: A Cross-Layer Analysis of Scalable Building Cluster Control

Building cluster control has emerged as a promising approach for enabling flexible and coordinated operation of distributed building systems, yet its transition from pilot demonstrations to routine grid-interactive operation remains limited. This paper argues that this gap cannot be explained by control algorithms alone. Instead, it arises from interacting barriers in communication infrastructure, data and semantic interoperability, uncertainty management, stakeholder participation, market design, and policy support. Accordingly, the paper reviews both technical and non-technical barriers to building cluster control. Technical challenges include heterogeneous devices and protocols, communication latency and reliability, distributed decision-making, and uncertainty propagation across aggregated loads. Non-technical barriers include user participation, stakeholder coordination, incentive allocation, and data governance. Existing solution approaches are synthesized, including semantic interoperability frameworks, edge and hierarchical communication architectures, distributed and transactive control strategies, uncertainty-aware optimization, policy mechanisms, and market reforms. Based on this analysis, two research directions are identified: testing infrastructures that can evaluate control performance under realistic multi-building conditions, and abstraction methods that allow building clusters to interact with other energy sectors through standardized flexibility representations. Overall, the paper provides a structured review of how building cluster control can move from isolated demonstrations toward reproducible, market-compatible, and grid-relevant implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal deployment of resources for maximizing impact in spreading processes

Significance Spreading processes play an increasingly important role in marketing, opinion setting, and epidemic modeling. Most existing algorithms for optimal resource allocation in spreading processes are based on topological characteristics of the underlying network and aim to maximize impact at infinite time. Clearly, realistic and efficient real-time allocation policies should consider both network properties and details of the dynamics; additionally, control may be applied only to a restricted set of accessible nodes, and impact should be maximized in a limited time window. We introduce a probabilistic targeting framework that incorporates the dynamics and encompasses previously considered optimization formulations. It is based on a scalable dynamic message-passing approach that allows for the solution of large real-world network instances.

60 APPLIED LIFE SCIENCES↗

Split‐dose 4‐L polyethylene glycol regimen for patients with previous colorectal surgery in bowel preparation before colonoscopy: A randomized, controlled, single‐blind study

OBJECTIVE We aimed to investigate the efficacy of a split‐dose 4‐L polyethylene glycol (PEG) regimen for the quality of bowel preparation in Asian patients with previous colorectal surgery for colorectal cancer (CRC). METHODS This was a prospective, single‐center, randomized controlled, endoscopist‐blinded study. Patients with previous colorectal surgery for CRC were randomly allocated to a routine, morning‐only 2‐L PEG (2‐MO) group or a split‐dose 4‐L PEG (4‐SD) group. The primary outcome was a successful bowel preparation rate. Secondary outcomes were polyp detection rate (PDR), adenoma detection rate (ADR), patient compliance, satisfaction, tolerance, willingness to repeat the preparation and difficulty of the bowel preparation process. RESULTS In total, 187 patients were included (93 in the 2‐MO group, 94 in the 4‐SD group) in this study. The rate of successful bowel preparation in the 4‐SD group was higher than in the 2‐MO group (89.4% vs 66.7%, P < 0.001) in an intention‐to‐treat analysis according to the Aronchick score. Patients’ satisfaction with the bowel preparation process in the 4‐SD group was superior to that in the 2‐MO group (93.4% vs 82.2%, P = 0.021). No significant differences were detected in PDR, ADR, patient compliance, tolerance, willingness to repeat the preparation or difficulty of the bowel preparation process. CONCLUSIONS The 4‐SD PEG regimen was superior to a routine, morning‐only 2‐L PEG preparation for bowel preparation in an Asian population with previous colorectal surgery.

Liu, Zhu↗

Priority-enabled Load Balancing for Dispersed Computing

Opportunistic managed access to local in-network compute resources can improve the performance of distributed applications and reduce the dependence on shared network resources. Instead of backhauling application data to a centralized cloud data center for processing, networked services may be adaptively and continuously dispersed into shared compute resources that are closer to the source of need. While this approach has several benefits, support for mission-aware access to computation is often an afterthought, and is implemented as a brittle extension over traditional load-balancer solutions.In this work, we investigate the design of two priority-aware resource allocation strategies and two load-balancing dispatching strategies as first class citizens in an open-source dispersed computing middleware. We present a control theoretic analysis of these load-balancing primitives to identify weaknesses and strengths in our design, and recommend future directions. In parallel, we prototype two priority-aware allocation algorithms to validate our priority predictions. In initial experiments our prototype shows substantial gains in processing prioritized load. Finally, we make our source-code and experimental configurations open source.

Paulos, Aaron↗

Nonlinear control of safety factor gradient in tokamaks using spatially variable electron cyclotron current drives

Active control of plasma properties may be necessary to achieve stable operation of next-generation tokamaks over large time scales. Such control algorithms can regulate the plasma properties to avoid the onset of magnetohydrodynamic (MHD) instabilities. For instance, the global and local properties of the safety factor profile are linked to the onset of neoclassical tearing modes (NTMs). This work proposes a model-based control approach for deterring/delaying NTMs through active modulation of one of the safety factor properties - the gradient of the safety factor profile at a particular rational safety factor surface. In particular, a novel control-oriented model for the local safety factor gradient is developed. The nonlinear control model is governed by a nonautonomous ordinary differential equation that accounts for a given rational safety factor surface’s spatial variation over time. Further, to improve the controllability of the spatially evolving parameter, the control model treats ECH&CD positions, along with noninductive powers, as controllable variables. A nonlinear control algorithm based on feedback linearization with optimization is synthesized to achieve the objective of regulating the safety factor gradient around a given target. The proposed algorithm allocates optimal ECH&CD positions, in addition to auxiliary powers, at each time instant as the rational safety factor surface drifts to locations with a low control authority. Stability guarantees of the proposed control law are also discussed in this work. The proposed algorithm is tested for a DIII-D tokamak scenario in nonlinear simulations carried out using the Control Oriented Transport SIMulator (COTSIM). Both fixed and moving ECH&CD cases are studied, and their outcomes are compared. Simulation results demonstrate that enthusiastic regulation of the safety factor gradient can be achieved during the ramp-up and flat-top phases of tokamak operation in both fixed and moving ECH&CD cases. However, real-time updates of ECH&CD positions can prevent the saturation of auxiliary powers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A System Approach to Deep Heating Savings Through Measurement, Management, and Motivation

Across multi-tenant commercial office and multifamily buildings, centrally metered fuel use represents a substantial fraction of whole-building energy use. Energy audit practitioners understand that improving heating distribution efficiency is typically more of an opportunity than combustion efficiency and that differing thermal comfort preferences between tenants are the bane of operators across these building typologies. There is an unmet market need for retrofit technologies that allow for the delivery of the right amount of heat to the right spaces, at the right time. The Energy Management and Information System (EMIS) package fills this gap through enhanced controls and metering, incorporating low-cost sensors and wireless communication infrastructure to provide a platform for ongoing commissioning and tenant feedback, including heat cost allocation. With support from the US DOE Building Technologies Office, Steven Winter Associates, Inc. (SWA) partnered with Sentient Buildings, E Source, building owners, and utility and policy stakeholders, to demonstrate a market viable EMIS that achieves a reduction in space heating energy use by reducing heating load, improving control, and positively impacting behavior while providing an acceptable financial return. In this study, EMIS packages were implemented in two New York City multifamily rental buildings. Both buildings conducted basic mechanical work (e.g., repairing steam traps) to ensure the heating system was operating well before any tenant feedback was layered in. Heating Energy Use Reports (HEUR) were created to provide tenants with social comparisons and energy savings tips to influence their behavior; these were provided monthly to all tenants in both buildings. Additionally, one building allocated heating costs to a portion of the tenants. Heat cost allocation (HCA) has a long history in the European Union (EU), although it is not common in the US or in steam-heated buildings. SWA leveraged existing EU best practices and stakeholder feedback to develop a Heat Cost Allocation algorithm that was considered equitable and intuitive. Energy use and tenant behavior impacts were tracked throughout the study. The basic mechanical repair work saved between 11-20% of heating energy. Those savings rose to 17-24% with the addition of tenant feedback. While it may not be possible to precisely determine the impact of COVID-19 on research studies like this, there may have been additional savings realized had the study taken place in a period of normal occupancy patterns. These types of central heating systems have been a blind spot for utilities, who have traditionally had little visibility into detailed behind-the-meter gas usage. Heating energy savings stayed consistent during the coldest months, indicating the potential for utilities to utilize EMIS packages for peak gas demand reductions or demand response programs. Tenant comfort was also improved. Post installation, room temperatures more closely matched thermostat set points. Perhaps due to this greater level of control, the vast majority of tenants being billed for heating were accepting of the allocation costs. And tenants receiving heat cost allocations were more likely to reduce their thermostat setpoints than tenants receiving behavioral feedback without financial impacts were. Variation in building specifics makes it difficult to provide precise energy and financial savings estimates. But within the range of expected conditions, the study identified a few key variables that can have the greatest impact on financial returns: the cost of fuel, the ability and willingness to allocate heating costs to tenants, and a well-functioning heating system as a starting point. This study focused on two multifamily buildings, but additional use cases, such as commercial buildings and affordable housing, should be explored to better understand the full market potential. While this type of upgrade has the potential for deep energy reductions and cost savings, future projects should take into account the balance of costs and benefits between owners and tenants, especially in the affordable, regulated, or other low-to-moderate income (LMI) segments of the market. Rent credits, utility allowances, or a shared savings program are possible options to accelerate adoption of this strategy in these market segments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Controlling circuitry underlies the growth optimization of Saccharomyces cerevisiae

Microbial growth emerges from coordinated synthesis of various cellular components from limited resources. In Saccharomyces cerevisiae, cyclic AMP (cAMP)-mediated signaling is shown to orchestrate cellular metabolism; however, it remains unclear quantitatively how the controlling circuit drives resource partition and subsequently shapes biomass growth. Here we combined experiment with mathematical modeling to dissect the signaling-mediated growth optimization of S. cerevisiae. We showed that, through cAMP-mediated control, the organism achieves maximal or nearly maximal steady-state growth during the utilization of multiple tested substrates as well as under perturbations impairing glucose uptake. However, the optimal cAMP concentration varies across cases, suggesting that different modes of resource allocation are adopted for varied conditions. Under settings with nutrient alterations, S. cerevisiae tunes its cAMP level to dynamically reprogram itself to realize rapid adaptation. Moreover, to achieve growth maximization, cells employ additional regulatory systems such as the GCN2-mediated amino acid control. This study establishes a systematic understanding of global resource allocation in S. cerevisiae, providing insights into quantitative yeast physiology as well as metabolic strain engineering for biotechnological applications.

59 BASIC BIOLOGICAL SCIENCES↗

Data for Controlling Circuitry Underlies the Growth Optimization of Saccharomyces cerevisiae

Microbial growth emerges from coordinated synthesis of various cellular components from limited resources. In Saccharomyces cerevisiae , cyclic AMP (cAMP)-mediated signaling is shown to orchestrate cellular metabolism; however, it remains unclear quantitatively how the controlling circuit drives resource partition and subsequently shapes biomass growth. Here we combined experiment with mathematical modeling to dissect the signaling-mediated growth optimization of S. cerevisiae . We showed that, through cAMP-mediated control, the organism achieves maximal or nearly maximal steady-state growth during the utilization of multiple tested substrates as well as under perturbations impairing glucose uptake. However, the optimal cAMP concentration varies across cases, suggesting that different modes of resource allocation are adopted for varied conditions. Under settings with nutrient alterations, S. cerevisiae tunes its cAMP level to dynamically reprogram itself to realize rapid adaptation. Moreover, to achieve growth maximization, cells employ additional regulatory systems such as the GCN2-mediated amino acid control. This study establishes a systematic understanding of global resource allocation in S. cerevisiae , providing insights into quantitative yeast physiology as well as metabolic strain engineering for biotechnological applications.

Conversion↗

Incentive-Based Control and Coordination of Distributed Energy Resources. Final Report

The rapid growth of low-inertia renewable energy resources represents an immense opportunity for the U.S. to minimize its carbon footprint, while presenting a challenge for system operators as traditional “spinning” generation resources are displaced. This transformation requires solutions to robustly and cost-effectively manage dynamic changes on the grid while ensuring quality of service. There is growing recognition that distributed energy resources (DERs – loads, distributed generation, storage, electric vehicles, etc.) represent a great potential to perform this function. This report details a scalable hierarchical control strategy for coordinating thousands of heterogeneous DERs in order to provide three ancillary gird services: 1) frequency response, a rapid (within 2 seconds) service used to maintain the grid at 60 Hz; 2) regulation response, a larger response used to balance on-going differences in supply and demand on the grid; and, 3) ramping reserve, used to bring on capacity to replace lost generation. The developed control architecture consists of 1) a Distribution Reliability Coordinator (DRC), 2) aggregator controllers, and finally, 3) DER controllers. The DRC coordinates all the flexible loads and distributed energy resources on the distribution system and bids the aggregate flexibility into the wholesale market. The DRC also performs resource allocation (deciding how the flexible devices on the distribution system will be dispatched) to meet the requirements for each of the three ancillary services. The aggregators control a collection of devices that are geographically co-located and provide a platform to aggregate their flexibility and mitigate uncertainty associated with a single flexible load by managing a large aggregation of similar loads (so that any stochastic effects average out). Finally, DER controllers (for example, thermostats for air conditioners, chargers for electric vehicles) adjust the power consumption of individual devices to ensure accurate and reliable delivery of the requested grid services. Evaluation and validation of this approach was conducted with a mixture of simulation and hardware testing for a range of DERs in residential (air conditioners and water heaters), commercial HVAC (ventilation fans and central chiller plants), and micro-grids (battery energy storage, solar PV etc.). This culminated in DER hardware and simulation models operating in conjunction with grid simulations as part of a large scale federated test-bed demonstration. Simulations of over 10,000 controllable residential devices (a combination of air conditioners, water heaters, batteries, and electric vehicles) demonstrated that this advanced control approach could simultaneously meet all three grid services. Furthermore, hardware-in-the-loop testing was performed with operational micro-grid and commercial building HVAC equipment. The micro-grid equipment (representing PV, battery storage, and back-up generators) demonstrated the ability to meet all frequency response requirements (except ramping time). The commercial building HVAC ventilation equipment successfully provided the regulating response service. An Industry Advisory Board (IAB) was formed and engaged throughout the project to get feed-back on project risks and potential commercialization barriers. Their input was invaluable in identify key risks stemming from regulatory and market access challenges, financial risks from under-performance, and competitive threats from utility-scale solutions such as integrated storage. A phased commercialization plan was developed that addresses continued risk reduction (value proposition refinement and performance uncertainty assessments), piloting through field demonstrations with key stakeholders, and finally, deployment as an emerging standard for DER control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Calibrating the Classical Hardness of the Quantum Approximate Optimization Algorithm

The trading of fidelity for scale enables approximate classical simulators such as matrix product states (MPSs) to run quantum circuits beyond exact methods. A control parameter, the so-called bond dimension $\mathcal{χ}$ for MPSs, governs the allocated computational resources and the output fidelity. Here, we characterize the fidelity for the quantum approximate optimization algorithm by the expectation value of the cost function that it seeks to minimize and find that it follows a scaling law $\mathscr{F}$(ln $\mathcal{χ}$/N), where N is the number of qubits. With ln $\mathcal{χ}$ amounting to the entanglement that a MPS can encode, we show that the relevant variable for investigating the fidelity is the entanglement per qubit. Importantly, our results calibrate the classical computational power required to achieve the desired fidelity and benchmark the performance of quantum hardware in a realistic setup. For instance, we quantify the hardness of performing better classically than a noisy superconducting quantum processor by readily matching its output to the scaling function. Moreover, we relate the global fidelity to that of individual operations and establish its relationship with $\mathcal{χ}$ and N. We sharpen the requirements for noisy quantum computers to outperform classical techniques at running a quantum optimization algorithm in speed, size, and fidelity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Prioritized Threshold Allocation for Distributed Frequency Response

Higher penetration of renewable generation will increase the demand for adequate (and cost-effective) controllable resources on the grid that can mitigate and contain the contingencies locally before it can cause a network-wide collapse. However, end-use constraints can potentially lead to load unavailability when an event occurs, leading to unreliable demand response services. Sensors measurements and knowledge of the local load dynamics could be leveraged to improve the performance of load control algorithms. In the context of hierarchical frequency response using ensemble of switching loads, we present a metric to evaluate the fitness of each device in successfully providing the ancillary service. Furthermore a fitness-based assignment of control set-points is formulated which achieves reliable performance under different operating conditions. Monte Carlo simulations of ensembles of electric water heaters and residential air-conditioners are performed to evaluate the proposed control algorithm.

Nandanoori, Sai Pushpak↗

Scanning holographic optical tweezers

The aim of this Letter is to introduce a new optical tweezers approach, called scanning holographic optical tweezers (SHOT), which drastically increases the working area (WA) of the holographic-optical tweezers (HOT) approach, while maintaining tightly focused laser traps. A 12-fold increase in the WA is demonstrated. The SHOT approach achieves its utility by combining the large WA of the scanning optical tweezers (SOT) approach with the flexibility of the HOT approach for simultaneously moving differently structured optical traps in and out of the focal plane. This Letter also demonstrates a new heuristic control algorithm for combining the functionality of the SOT and HOT approaches to efficiently allocate the available laser power among a large number of traps. The proposed approach shows promise for substantially increasing the number of particles that can be handled simultaneously, which would enable optical tweezers additive fabrication technologies to rapidly assemble microgranular materials and structures in reasonable build times.

42 ENGINEERING↗

Reinforcement Learning for Volt- Var Control: A Novel Two-stage Progressive Training Strategy

This paper develops a reinforcement learning (RL) approach to solve a cooperative, multi-agent Volt-Var Control (VVC) problem for high solar penetration distribution systems. The ingenuity of our RL method lies in a novel two-stage progressive training strategy that can effectively improve training speed and convergence of the machine learning algorithm. In Stage 1 (individual training), while holding all the other agents inactive, we separately train each agent to obtain its own optimal VVC actions in the action space: fconsume, generate, do-nothingg. In Stage 2 (cooperative training), all agents are trained again coordinatively to share VVC responsibility. Rewards and costs in our RL scheme include (i) a system-level reward (for taking an action), (ii) an agent-level reward (for doing-nothing), and (iii) an agent-level action cost function. This new framework allows rewards to be dynamically allocated to each agent based on their contribution while accounting for the trade-off between control effectiveness and action cost. The proposed methodology is tested and validated in a modified IEEE 123-bus system using realistic PV and load profiles. Simulation results confirm that the proposed approach is robust and computationally efficient; and it achieves desirable volt-var control performance under a wide range of operation conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FastProNGS: fast preprocessing of next-generation sequencing reads

Background Next-generation sequencing technology is developing rapidly and the vast amount of data that is generated needs to be preprocessed for downstream analyses. Yet, until now, software that can efficiently make all the quality assessments and filtration of raw data is still lacking. Results We developed FastProNGS to integrate the quality control process with automatic adapter removal. Parallel processing was implemented to speed up the process by allocating multiple threads. Compared with similar up-to-date preprocessing tools, FastProNGS is by far the fastest. Read information before and after filtration can be output in plain-text, JSON, or HTML formats with user-friendly visualization. Conclusions FastProNGS is a rapid, standardized, and user-friendly tool for preprocessing next-generation sequencing data within minutes. It is an all-in-one software that is convenient for bulk data analysis. It is additionally very flexible and can implement different functions using different user-set parameter combinations.

97 MATHEMATICS AND COMPUTING↗