Search NASA⌕ Search

SEARCH · Search NASA

Results for “Coordinate transformations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Range 7 Scanner Integration with PaR Robot Scanning System

An interface bracket and coordinate transformation matrices were designed to allow the Range 7 scanner to be mounted on the PaR Robot detector arm for scanning the heat shield or other object placed in the test cell. A process was designed for using Rapid Form XOR to stitch data from multiple scans together to provide an accurate 3D model of the object scanned. An accurate model was required for the design and verification of an existing heat shield. The large physical size and complex shape of the heat shield does not allow for direct measurement of certain features in relation to other features. Any imaging devices capable of imaging the entire heat shield in its entirety suffers a reduced resolution and cannot image sections that are blocked from view. Prior methods involved tools such as commercial measurement arms, taking images with cameras, then performing manual measurements. These prior methods were tedious and could not provide a 3D model of the object being scanned, and were typically limited to a few tens of measurement points at prominent locations. Integration of the scanner with the robot allows for large complex objects to be scanned at high resolution, and for 3D Computer Aided Design (CAD) models to be generated for verification of items to the original design, and to generate models of previously undocumented items. The main components are the mounting bracket for the scanner to the robot and the coordinate transformation matrices used for stitching the scanner data into a 3D model. The steps involve mounting the interface bracket to the robot's detector arm, mounting the scanner to the bracket, and then scanning sections of the object and recording the location of the tool tip (in this case the center of the scanner's focal point). A novel feature is the ability to stitch images together by coordinates instead of requiring each scan data set to have overlapping identifiable features. This setup allows models of complex objects to be developed even if the object is large and featureless, or has sections that don't have visibility to other parts of the object for use as a reference. In addition, millions of points can be used for creation of an accurate model [i.e. within 0.03 in. (=0.8 mm) over a span of 250 in. (=635 mm)].

Schuler, Jason↗

Structures, spectroscopic studies and solid-state thermal transformations of coordination polymers from P{sub 4}Se{sub 3} and CuX (X=Cl, Br, I)

The formation of coordination polymers (CuCl)P{sub 4}Se{sub 3} (1), (CuBr){sub 3}(P{sub 4}Se{sub 3}){sub 2} (2), (CuI){sub 3}(P{sub 4}Se{sub 3}){sub 2} (3) and (CuI)P{sub 4}Se{sub 3} (4), from solutions of copper(I) halides and P{sub 4}Se{sub 3} by diffusion methods has been studied. The new compounds were characterized by X-ray crystallography, solid-state {sup 31}P MAS NMR and Raman spectroscopy. Theoretical studies on the DFT level in the crystalline phase allowed the unequivocal assignment of the recorded Raman shifts between 200 and 480 cm{sup -1}. The structure of 1 consists of a 2D network of castellated [CuCl]{sub n} chains and bidentate P{sub 4}Se{sub 3} molecules. The 3D network of 2 comprises [CuBr]{sub n} chains, which are linked by tridentate P{sub 4}Se{sub 3} molecules. Compound 3 is a three-dimensional polymer composed of four-membered (CuI){sub 2} rings and castellated [CuI]{sub n} chains, which are linked by tridentate P{sub 4}Se{sub 3} molecules involving two basal and the apical P atoms. Thermal conversion of 1 at 230 deg. C gives (CuCl){sub 3}(P{sub 4}Se{sub 3}){sub 2} (5), which is isostructural with 2. The thermal conversion of (CuI){sub 3}P{sub 4}S{sub 3}, which was studied for comparison gave at 371 deg. C (CuI){sub 3}P{sub 4}S{sub 4}, Cu{sub 3}PS{sub 4} and small amounts of Cu{sub 6}PS{sub 5}I. - Graphical Abstract: New coordination polymers have been prepared and characterized by the reaction of P{sub 4}Se{sub 3} and copper(I) halides solutions under diffusion conditions. Highlights: > Coordination polymers from P{sub 4}Se{sub 3} and copper(I) halide are described. > Solid-state phases are prepared from solution by interdiffusion techniques. > One-, two- and three-dimensional polymers are formed. > Up to three P atoms are involved in coordination to copper. > Application of {sup 31}P MAS NMR spectroscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On differential transformations between Cartesian and curvilinear (geodetic) coordinates

Differential transformations are developed between Cartesian and curvilinear orthogonal coordinates. Only matrix algebra is used for the presentation of the basic concepts. After defining the reference systems used the rotation (R), metric (H), and Jacobian (J) matrices of the transformations between cartesian and curvilinear coordinate systems are introduced. A value of R as a function of H and J is presented. Likewise an analytical expression for J(-1) as a function of H(-2) and R is obtained. Emphasis is placed on showing that differential equations are equivalent to conventional similarity transformations. Scaling methods are discussed along with ellipsoidal coordinates. Differential transformations between elipsoidal and geodetic coordinates are established.

Soler, T.↗

Full dimensional Franck-Condon factors for the acetylene A{sup ~} {sup 1}A{sub u}—X{sup ~1}Σ{sup +}{sub g} transition. I. Method for calculating polyatomic linear—bent vibrational intensity factors and evaluation of calculated intensities for the gerade vibrational modes in acetylene

Franck-Condon vibrational overlap integrals for the A{sup ~1}A{sub u}—X{sup ~1}Σ{sup +}{sub g} transition in acetylene have been calculated in full dimension in the harmonic normal mode basis. The calculation uses the method of generating functions first developed for polyatomic Franck-Condon factors by Sharp and Rosenstock [J. Chem. Phys. 41(11), 3453–3463 (1964)], and previously applied to acetylene by Watson [J. Mol. Spectrosc. 207(2), 276–284 (2001)] in a reduced-dimension calculation. Because the transition involves a large change in the equilibrium geometry of the electronic states, two different types of corrections to the coordinate transformation are considered to first order: corrections for axis-switching between the Cartesian molecular frames and corrections for the curvilinear nature of the normal modes at large amplitude. The angular factor in the wave function for the out-of-plane component of the trans bending mode, ν{sub 4}{sup ″}, is treated as a rotation, which results in an Eckart constraint on the polar coordinates of the bending modes. To simplify the calculation, the other degenerate bending mode, ν{sub 5}{sup ″}, is integrated in the Cartesian basis and later transformed to the constrained polar coordinate basis, restoring the conventional v and l quantum numbers. An updated A{sup ~}-state harmonic force field obtained recently in the R. W. Field research group is evaluated. The results for transitions involving the gerade vibrational modes are in qualitative agreement with experiment. Calculated results for transitions involving ungerade modes are presented in Paper II of this series [G. B. Park, J. H. Baraban, and R. W. Field, “Full dimensional Franck–Condon factors for the acetylene A{sup ~1}A{sub u}—X{sup ~1}Σ{sup +}{sub g} transition. II. Vibrational overlap factors for levels involving excitation in ungerade modes,” J. Chem. Phys. 141, 134305 (2014)].

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Forebody and afterbody solutions of the Navier-Stokes equations for supersonic flow over blunt bodies in a generalized orthogonal coordinate system

A coordinate transformation, which can approximate many different two-dimensional and axisymmetric body shapes with an analytic function, is used as a basis for solving the Navier-Stokes equations for the purpose of predicting 0 deg angle of attack supersonic flow fields. The transformation defines a curvilinear, orthogonal coordinate system in which coordinate lines are perpendicular to the body and the body is defined by one coordinate line. This system is mapped in to a rectangular computational domain in which the governing flow field equations are solved numerically. Advantages of this technique are that the specification of boundary conditions are simplified and, most importantly, the entire flow field can be obtained, including flow in the wake. Good agreement has been obtained with experimental data for pressure distributions, density distributions, and heat transfer over spheres and cylinders in supersonic flow. Approximations to the Viking aeroshell and to a candidate Jupiter probe are presented and flow fields over these shapes are calculated.

Gnoffo, P. A.↗

Sonic Boom Propagation Model Based on a Single-Ray Jacobian

A sonic boom is a nonlinear event whose propagation can be modeled involving two stages. The first stage consists of ray path calculations using linear approximations, while the second stage deals with a nonlinear transport of the acoustic energy along these paths. This presentation discusses a second-order finite difference numerical approach used to predict the ray paths in range-dependent atmospheres and compares it to existing finite difference schemes. The approach is validated using exact solutions obtained for stratified atmospheres. In the second stage, the geometrical spreading effect needed in determining sonic boom waveforms from a Burgers' equation is obtained using a method that only needs a single ray rather than four rays required by most existing sonic boom propagation codes. The single-ray method calculates the Jacobian, associated with the coordinate transformation from a suitable ray coordinate system to the Cartesian coordinate system, directly from the ray tracing equations. While the four-ray method approximates the geometrical spreading using a finite difference scheme involving the four rays, the single-ray method does not rely on this approximation and instead depends purely on the acoustical kinematic properties of the atmosphere. Comparisons of results using these two methods are discussed.

sonic boom↗

Analytic descriptions of parabolic X-ray mirrors

On X-ray beamlines and telescopes, glancing-incidence mirrors with parabolic profiles are used to collimate, focus, and collect light. Here, analytic descriptions for paraboloidal, plane-parabolic, and parabolic cylindrical mirrors in several congruent geometries that are commonly used in fabrication, metrology, and modeling are provided. The exact expressions are derived directly from Fermat's principle, without coordinate transformations, in several mirror-centered coordinate systems, including one with the surface tangent to the central point of intersection. Coefficients for a sixth-order polynomial series approximation are calculated for that coordinate system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Synchronization of Lienard-Type Oscillators in Uniform Electrical Networks

This paper presents a condition for global asymptotic synchronization of Lienard-type nonlinear oscillators in uniform LTI electrical networks with series R-L circuits modeling interconnections. By uniform electrical networks, we mean that the per-unit-length impedances are identical for the interconnecting lines. We derive conditions for global asymptotic synchronization for a particular feedback architecture where the derivative of the oscillator output current supplements the innate current feedback induced by simply interconnecting the oscillator to the network. Our proof leverages a coordinate transformation to a set of differential coordinates that emphasizes signal differences and the particular form of feedback permits the formulation of a quadratic Lyapunov function for this class of networks. This approach is particularly interesting since synchronization conditions are difficult to obtain by means of quadratic Lyapunov functions when only current feedback is used and for networks composed of series R-L circuits. Our synchronization condition depends on the algebraic connectivity of the underlying network, and reiterates the conventional wisdom from Lyapunov- and passivity-based arguments that strong coupling is required to ensure synchronization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Objective assessment of deformable image registration in radiotherapy: A multi-institution study

The looming potential of deformable alignment tools to play an integral role in adaptive radiotherapy suggests a need for objective assessment of these complex algorithms. Previous studies in this area are based on the ability of alignment to reproduce analytically generated deformations applied to sample image data, or use of contours or bifurcations as ground truth for evaluation of alignment accuracy. In this study, a deformable phantom was embedded with 48 small plastic markers, placed in regions varying from high contrast to roughly uniform regional intensity, and small to large regional discontinuities in movement. CT volumes of this phantom were acquired at different deformation states. After manual localization of marker coordinates, images were edited to remove the markers. The resulting image volumes were sent to five collaborating institutions, each of which has developed previously published deformable alignment tools routinely in use. Alignments were done, and applied to the list of reference coordinates at the inhale state. The transformed coordinates were compared to the actual marker locations at exhale. A total of eight alignment techniques were tested from the six institutions. All algorithms performed generally well, as compared to previous publications. Average errors in predicted location ranged from 1.5 to 3.9 mm, depending on technique. No algorithm was uniformly accurate across all regions of the phantom, with maximum errors ranging from 5.1 to 15.4 mm. Larger errors were seen in regions near significant shape changes, as well as areas with uniform contrast but large local motion discontinuity. Although reasonable accuracy was achieved overall, the variation of error in different regions suggests caution in globally accepting the results from deformable alignment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A rapid method for obtaining frequency-response functions for multiple input photogrammetric data

A two-digital-camera photogrammetric technique for measuring the motion of a vibrating spacecraft structure or wing surface and an applicable data-reduction algorithm are presented. The 3D frequency-response functions are obtained by coordinate transformation from averaged cross and autopower spectra derived from the 4D camera coordinates by Fourier transformation. Error sources are investigated analytically, and sample results are shown in graphs.

Kroen, M. L.↗

Integration of vestibular and head movement signals in the vestibular nuclei during whole-body rotation

Single-unit recordings were obtained from 107 horizontal semicircular canal-related central vestibular neurons in three alert squirrel monkeys during passive sinusoidal whole-body rotation (WBR) while the head was free to move in the yaw plane (2.3 Hz, 20 degrees /s). Most of the units were identified as secondary vestibular neurons by electrical stimulation of the ipsilateral vestibular nerve (61/80 tested). Both non-eye-movement (n = 52) and eye-movement-related (n = 55) units were studied. Unit responses recorded when the head was free to move were compared with responses recorded when the head was restrained from moving. WBR in the absence of a visual target evoked a compensatory vestibulocollic reflex (VCR) that effectively reduced the head velocity in space by an average of 33 +/- 14%. In 73 units, the compensatory head movements were sufficiently large to permit the effect of the VCR on vestibular signal processing to be assessed quantitatively. The VCR affected the rotational responses of different vestibular neurons in different ways. Approximately one-half of the units (34/73, 47%) had responses that decreased as head velocity decreased. However, the responses of many other units (24/73) showed little change. These cells had signals that were better correlated with trunk velocity than with head velocity. The remaining units had responses that were significantly larger (15/73, 21%) when the VCR produced a decrease in head velocity. Eye-movement-related units tended to have rotational responses that were correlated with head velocity. On the other hand, non-eye-movement units tended to have rotational responses that were better correlated with trunk velocity. We conclude that sensory vestibular signals are transformed from head-in-space coordinates to trunk-in-space coordinates on many secondary vestibular neurons in the vestibular nuclei by the addition of inputs related to head rotation on the trunk. This coordinate transformation is presumably important for controlling postural reflexes and constructing a central percept of body orientation and movement in space.

Non-NASA Center↗