Search NASA⌕ Search

SEARCH · Search NASA

Results for “Corrosion Mitigation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Environmentally Compatible Vapor-Phase Corrosion Inhibitor for Space Shuttle Hardware

USA-SRB Element is responsible for the assembly and refurbishment of the non-motor components of the SRB as part of Space Shuttle. Thrust Vector Control (TVC) frames structurally support components of the TVC system located in the aft skirt of the SRB. TVC frames are exposed to the seacoast environment after refurbishment and, also, to seawater immersion after splashdown, and during tow-back to CCAFS-Hangar AF refurbishment facilities. During refurbishment operations it was found that numerous TVC frames were experiencing internal corrosion and coating failures, both from salt air and seawater intrusions. Inspectors using borescopes would visually examine the internal cavities of the complicated aluminum alloy welded tubular structure. It was very difficult for inspectors to examine cavity corners and tubing intersections and particularly, to determine the extent of the corrosion and coating anomalies. Physical access to TVC frame internal cavities for corrosion removal and coating repair was virtually impossible, and an improved method using a Liquid (water based) Vapor-phase Corrosion Inhibitor (LVCI) for preventing initiation of new corrosion, and mitigating and/or stopping existing corrosion growth was recommended in lieu of hazardous paint solvents and high VOC/solvent based corrosion inhibitors. In addition, the borescopic inspection method used to detect corrosion, and/or coating anomalies had severe limitations because of part geometry, and an improved non-destructive inspection (NDI) method using Neutron Radiography (N-Ray) was also recommended.

Novak, Howard L.↗

Environmentally Compatible Vapor-Phase Corrosion Inhibitor for Space Shuttle Hardware

USA-SRB Element is responsible for the assembly and refurbishment of the non-motor components of the SRB as part of Space Shuttle. Thrust Vector Control (TVC) frames structurally support components of the TVC system located in the aft skirt of the SRB (Solid Rocket Booster). TVC frames are exposed to the seacoast environment after refurbishment and, also, to seawater immersion after splashdown, and during tow-back to CCAFS-Hangar AF refurbishment facilities. During refurbishment operations it was found that numerous TVC frames were experiencing internal corrosion and coating failures, both from salt air and seawater intrusions. Inspectors using borescopes would visually examine the internal cavities of the complicated aluminum alloy welded tubular structure. It was very difficult for inspectors to examine cavity corners and tubing intersections and particularly. to determine the extent of the corrosion and coating anomalies. Physical access to TVC frame internal cavities for corrosion removal and coating repair was virtually impossible, and an improved method using a Liquid (water based) Vapor-phase Corrosion Inhibitor (LVCI) for preventing initiation of new corrosion, and mitigating and/or stopping existing corrosion growth was recommended in lieu of hazardous paint solvents and high VOC/solvent based corrosion inhibitors. In addition, the borescopic inspection method used to detect corrosion, and/or coating anomalies had severe limitations because of part geometry, and an improved non-destructive inspection (NDI) method using Neutron Radiography (N-Ray) was also recommended.

Novak, Howard L.↗

Environmentally Compatible Vapor-Phase Corrosion Inhibitor for Space Shuttle Hardware

USA-SRB Element is responsible for the assembly and refurbishment of the non-motor components of the SRB as part of Space Shuttle. Thrust Vector Control (TVC) frames structurally support components of the TVC system located in the aft skirt of the SRB. TVC frames are exposed to the seacoast environment after refurbishment and, also, to seawater immersion after splashdown, and during tow-back to CCAFS-Hangar AF refurbishment facilities. During refurbishment operations it was found that numerous TVC frames were experiencing internal corrosion and coating failures, both from salt air and seawater intrusions. Inspectors using borescopes would visually examine the internal cavities of the complicated aluminum alloy welded tubular structure. It was very difficult for inspectors to examine cavity corners and tubing intersections and particularly, to determine the extent of the corrosion and coating anomalies. Physical access to TVC frame internal cavities for corrosion removal and coating repair was virtually impossible, and an improved method using a Liquid (water based) Vapor-phase Corrosion Inhibitor (LVCI) for preventing initiation of new corrosion, and mitigating and/or stopping existing corrosion growth was recommended in lieu of hazardous paint solvents and high VOC / solvent based corrosion inhibitors. In addition, the borescopic inspection method used to detect corrosion, and/or coating anomalies had severe limitations because of part geometry, and an improved non-destructive inspection (NDI) method using Neutron Radiography (N-Ray) was also recommended.

Novak, Howard L.↗

Feasibility Study for Cathodic Protection of Waste Tanks at Hanford

The Hanford Nuclear Reservation site contains approximately 211 million liters of radioactive and chemically hazardous waste arising from nuclear weapons production, beginning with World War II, and continuing through the Cold War. The waste is stored in 177 carbon-steel underground storage tanks, of which 149 are single-shell tanks (SSTs) and the remaining are double-shell tanks (DSTs). The mission of an ongoing River Protection Project is to retrieve the waste from the underground storage tanks and then treat and immobilize (i.e., vitrify) it for disposal. Waste from the older SSTs is being progressively retrieved into the newer DSTs for storage pending treatment, immobilization, and disposal. Waste chemistry controls are in place to mitigate general corrosion, pitting corrosion, and stress corrosion cracking (SCC) and minimize corrosion risks to the carbon steel tank liners of DST at the Hanford Site. The chemistry control program focuses on preserving liner integrity while balancing the need for caustic/nitrite additions that have large downstream impacts on vitrification. Some of the DSTs store salt cake or sludge waste layers contain out-of-specification interstitial liquids that contact the primary tank bottom or sidewall. Remediation of such layers through chemical additions is not practical. At the present time, the most significant leak integrity concern at Hanford is for corrosion of the tank bottoms of DSTs where the solids layer is out of specification because of hydroxide ion depletion and consequently, pH values that are less than 12. Cathodic protection (CP) has been proposed as a possible way to protect the liners of such tanks against corrosion. The objective of this project was to investigate the feasibility of applying CP to Hanford DSTs to mitigate internal corrosion of the carbon steel tank primary liners. The scope of the project included (1) a literature review on the application of CP to storage tank systems, in general, and to waste tanks at the Savannah River Site (SRS) and Hanford, (2) a review of the finite element analysis (FEA) model recently developed to evaluate potentials for a DST, and (3) the development of a boundary element analysis (BEA) model for CP for a DST. Tank AN-107, one of the Hanford DSTs, was selected for this work because (1) the bottommost waste layer in the tank is out-of-specification, and (2) electrochemical and resistivity data, based on recent waste sampling and testing, are available for this tank. The overarching conclusion of this study is that, based on the available information, it is feasible to apply CP to mitigate internal corrosion of the primary liners of the Hanford DSTs. However, significant additional information and work are required before a CP system can be designed. Recommendations for next steps in the design of the CP system will be presented.

WIERSMA, BRUCE↗

Corrosion-Resistant Coatings for Mitigation and Repair of Spent Nuclear Fuel Dry Storage Canisters

This report summarizes the results of a literature survey on coatings and surface treatments that are used to provide corrosion protection for exposed metal surfaces. The coatings are discussed in the context of being used on stainless steel spent nuclear fuel (SNF) dry storage canisters for potential prevention or repair of corrosion and stress corrosion cracking. The report summarizes the properties of different coating classes, including the mechanisms of protection, their physical properties, and modes of degradation (thermal, chemical, radiological). Also discussed are the current standard technologies for application of the coatings, including necessary surface pretreatments (degreasing, rust removal, grinding) and their effects on coating adhesion and performance. The coatings are also classified according their possible use for in situ repair; ex situ repair, requiring removal from the overpack; and ex situ prevention, or application prior to fuel loading to provide corrosion protection over the lifetime of the canister.

36 MATERIALS SCIENCE↗

Integrity Monitoring and Assessment, Prediction, Repair, and Corrosion Control of the Hanford Storage Tanks — 25213

BACKGROUND AND PROJECT TASKS Proposed work addresses focus area 1: Waste Retrieval, Transport and Closure, with particular focus on increasing volume available for tank storage 1) Refurbish/fortify existing double shell storage tanks (Tank Refurbish – Polymer Grout) 2) Robust monitoring tools for internal corrosion (Integrity Monitoring -Reference Electrodes) 3) Mitigate external corrosion (Degradation Prevention - Cathodic Protection) 4) Determine viability of constructing new tanks, and storage room creation by way of evaporation (Cost Benefit Analysis)

Shukla, Pavan K. [Savannah River National Laborato↗

Determining Drying Conditions to Mitigate Hanford Transfer Line Corrosion

Hanford Site Background • Hanford site located in Washington State and established in 1943: 1460 km2 • Since 1988 the site has been engaged in a comprehensive environmental clean-up effort. Waste Tanks • 177 underground tanks with 56 million gallons of high-level radioactive waste and chemical waste in 150 Single Shell Tanks (SSTs) and 27 Double Shell Tanks (DSTs)

Shukla, Pavan K. [Savannah River National Laborato↗

Long-Term Corrosion Studies Of Pine Derived Bio-Oil And Blends With Heavy Fuel Oil

Biomass derived liquid fuels offer a means to reduce greenhouse gas emissions compared to those produced by combustion of petroleum derived liquid fuels. However, the corrosivity of bio-oils toward the less expensive structural materials creates a material selection problem for designers of storage tanks and combustion systems. Samples of candidate structural materials are being exposed for thousands of hours in multiple fast pyrolysis bio-oils and conditions to evaluate the corrosion resistance of these materials. One method to mitigate the corrosivity of bio-oils and speed their adoption, while also decreasing the pollution issues associated with low quality petroleum derived fuels, is to utilize blends of bio-oil and heavy fuel oil in engines currently solely burning a petroleum-based fuel. In addition to the corrosion studies conducted in 100% bio-oil, studies were also conducted with blends of the fast pyrolysis bio-oil produced from pine tree components with a heavy fuel oil that is used in ocean-going ships. This bio-oil had a very high carboxylic acid content which made it very corrosive to carbon and 2¼ Cr-1 Mo steel and even 409 stainless steel. The heavy fuel oil was not corrosive to carbon steel, but its sulfur content makes it a significant pollution producer and particularly undesirable for use near coastlines. Corrosion tests were conducted with the individual components and with various blends of the two liquid fuels. Studies showed a significantly lower corrosivity of the blends than would be projected assuming linear mixing behavior. Adoption of such blends holds the potential to reduce production of sulfur-containing exhaust gases as well as carbon dioxide from non-renewable fuels.

Keiser, Jim↗

Long-Term Corrosion Studies of Pine Derived Bio-Oil and Blends with Heavy Fuel Oil

Biomass derived liquid fuels offer a means to reduce greenhouse gas emissions compared to those produced by combustion of petroleum derived liquid fuels. However, the corrosivity of bio-oils toward the less expensive structural materials creates a material selection problem for designers of storage tanks and combustion systems. Samples of candidate structural materials are being exposed for thousands of hours in multiple fast pyrolysis bio-oils and conditions to evaluate the corrosion resistance of these materials. One method to mitigate the corrosivity of bio-oils and speed their adoption, while also decreasing the pollution issues associated with low quality petroleum derived fuels, is to utilize blends of bio-oil and heavy fuel oil in engines currently solely burning a petroleum-based fuel. In addition to the corrosion studies conducted in 100% bio-oil, studies were also conducted with blends of the fast pyrolysis bio-oil produced from pine tree components with a heavy fuel oil that is used in ocean-going ships. This bio-oil had a very high carboxylic acid content which made it very corrosive to carbon and 2¼ Cr-1 Mo steel and even 409 stainless steel. The heavy fuel oil was not corrosive to carbon steel, but its sulfur content makes it a significant pollution producer and particularly undesirable for use near coastlines. Corrosion tests were conducted with the individual components and with various blends of the two liquid fuels. Studies showed a significantly lower corrosivity of the blends than would be projected assuming linear mixing behavior. Adoption of such blends holds the potential to reduce production of sulfur-containing exhaust gases as well as carbon dioxide from non-renewable fuels.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Determining Drying Conditions to Mitigate Hanford Transfer Line Corrosion

Radioactive waste is stored in underground, carbon-steel double-shell tanks at the Department of Energy Hanford site.1,2,3 The underground transfer lines are used to transfer the waste between the tanks and other assets at the Hanford tank farm facilities. The transfer lines constructed before 1990 are pipe-in-pipe design with most of the lines having carbon steel carrier pipe and carbon steel encasements. The lines constructed after 1990 have a stainless-steel carrier with a carbon steel encasement. The carrier lines, which are in contact with the waste, provide a critical confinement function, while the encasements provide secondary containment to reduce the risk of a release and contamination to the environment. In 2022, a visual inspection of the annulus between the encasement and the carrier for one of the pre-1990 transfer lines revealed standing liquid in contact with the carrier pipe. Additionally, a significant build-up of corrosion products on the exterior of the carrier pipe and the interior of the encasement pipe was observed. To assess the extent of condition, borescope inspections were performed in the encasement space of additional transfer lines in the facility to provide a baseline. The inspection revealed that of the lines inspected, 29 had either moisture present or evidence that moisture had been present in the past (e.g., waterline corrosion where the pipe had been exposed to standing water). Additional inspections indicated several instances of pitting corrosion on the interior of the encasement and exterior the carrier transfer lines. An image of the carrier pipe with several pits is presented in Figure 1(a) and the profiled image of the transfer line section along with the pit depths are presented Figure 1(b). As seen in the figure, the deepest pit was 73 mils on the pipe section. These lines were designated as “do-not-use” until further compensatory actions are implemented to return the lines to service.

Shukla, Pavan K. [Savannah River National Laborato↗

Experimental evaluation of direct current magnetron sputtered and high-power impulse magnetron sputtered Cr coatings on SiC for light water reactor applications

Two types of physical vapor deposition Cr coatings were deposited on chemical vapor deposited SiC coupons using conventional direct current magnetron sputtering (DCMS) and high-power impulse magnetron sputtering (HiPIMS) to mitigate the corrosion of SiC, an advanced fuel and structural material in light water nuclear reactor cores. Coating microstructure was characterized using scanning electron microscopy and scanning transmission election microscopy. X-ray diffraction analysis was conducted for phase identification and qualitative analysis of residual stresses. The mechanical integrity of the coatings was evaluated using scratch testing, micro-indentation, and nano-indentation tests. Additionally, the microstructure of the DCMS coating consisted of fine columnar grains with nanoscale intercolumnar channels, while the HiPIMS microstructure was denser and free of any columnar defects. The DCMS coating showed a small tensile residual stress, while the HiPIMS coating was under compressive stress. Both types of coatings showed good mechanical integrity in terms of ductility and adhesion to the substrate. Corrosion performance of the coatings was assessed with a 30-day high temperature water autoclave test. Both types of coatings formed a protective Cr 2 O 3 surface layer 20-30 nm thick during the autoclave test. In the DCMS coating, the columnar defects provided permeation pathways for water penetration resulting in oxide formation in the intercolumnar regions in the interior of the coating. Overall, both types of Cr coatings offer promise for the mitigation of hydrothermal corrosion of SiC in light water reactor operating environments.

36 MATERIALS SCIENCE↗

A review on molten sulfate salts induced hot corrosion

Hot corrosion has been extensively observed in various high temperature applications, which might cause large economic losses. Here, to deepen the insight and understanding of hot corrosion, we provide a detailed discussion on hot corrosion induced by molten sulfate salt, in which Na 2 SO 4 is the main chemical reactant. The hot corrosion is triggered and sustained by the negative solubility gradient of protective oxide from the oxide/salt interface to salt/gas interface. In this work, we reviewed several key factors, including temperature, gas composition, molten salt composition, alloy element and external stress, influencing the hot corrosion of alloy beneath the molten salt. The application of anti-corrosion coating seems to be the most effective and commercial mothed to mitigate hot corrosion. Therefore, the progress of the development of effective coatings, e.g., Ni-Cr coatings, aluminide coatings, silicide coatings and MCrAlY(X) coatings, has also been summarized.

36 MATERIALS SCIENCE↗

L-Basin Microbial Monitoring Program - Evaluation of 20 Years of Monitoring

The SRNL L-Basin corrosion surveillance and microbial monitoring programs provide early detection and characterization of corrosion attack to the fuel and storage system materials resulting from prolonged exposure to the L-Basin water environment and of changes to and impact of the diverse microbial population, respectively. The early detection of corrosion allows for adjustment of the water quality, engineering management, and fuel storage configurations to mitigate excessive corrosion attack. While microbial influenced corrosion in L-Basin has not been detected, tracking and understanding the effect of microbial populations on the stored fuel and basin water will aid in identifying remedial measures to mitigate any detrimental impact. This report reviews the microbial monitoring activities since initial characterizations in the mid-1990s.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Corrosion protection of steel pipelines with metal-polymer composite barrier liners

Pipelines are efficient in transporting natural gas over large distances. Wet carbon dioxide present in pipelines can create an environment that is corrosive to steel. Polymer liners made from either polyethylene or polyamide (nylon) are presently used to mitigate internal corrosion in natural gas pipelines. Gas diffuses through all polymers over time, and polymer-only liners lower the steel corrosion rate by reducing the reactive gas flux to the internal surface of a pipeline. Composite liners, which incorporate one or more metallic layers that are impermeable to corrosive gases, offer better protection than polymer-only liners. In this study, we measured the methane, water vapor, and carbon dioxide permeability of a multi-layer barrier film and found it to be more effective in resisting gas permeation than polyethylene and nylon-11 films.

03 NATURAL GAS↗

Hot corrosion behavior of 304 & P91 graded composite transition joint under molten sulfate salts

A novel graded composite transition joint (GCTJ) between AISI 304 stainless steel and ASTM A335 P91 steel, has been demonstrated remarkablely superior creep performance compared to the conventional dissimilar metal weldment (DMW) under equivalent conditions. However, this advance is challenged by hot corrosion under salt deposition at elevated temperatures. Here, this study investigates the hot corrosion behavior of 304&P91 GCTJ exposed to sulfate salts at 700°C. Compared to the 304 steel, corrosion attacks initiate in the P91 triangle, where the dual-phase microstructure of ferrite and tempered martensite significantly influences pitting initiation. Anodic dissolution mainly occurs within the tempered martensite due to more vulnerable sites within the tempered martensite. With prolonged exposure, corrosion propagates across both phases, and the corrosion depth within the P91 triangle is related to the exposed surface area ratio between 304 and P91. Electrochemical analysis reveals the occurrence of galvanic corrosion between the 304 and P91, with a positive linear relationship between anodic dissolution current density (I a ) and the exposed surface area ratio between 304 and P91 in molten salts, further emphasizing the critical impact of this ratio on the corrosion severity in the P91 triangle. These findings underscore the importance of transition zone design optimization in mitigating localized corrosion.

Galvanic corrosion↗

Refinement of Pitting Factor Basis to Support the Corrosion Control Program (Interim Report)

At Savannah River Site (SRS), High-Level Waste is stored in below-grade tanks constructed of carbon steel. This waste is composed of sludge, salt cake, and/or supernate. In part, preparation of this waste for future processing involves dissolution of the salt cake layer. The salt dissolution process can create conditions that leave the carbon steel tanks susceptible to a number of corrosion processes. The salt to be dissolved contains high concentrations of nitrate, that once released, create an environment that may be conducive to pitting corrosion or stress corrosion cracking (SCC) of carbon steel. Additionally, during the salt dissolution process, in the absence of mixing, stratification of the supernatant liquid may occur. This can result in less dense, more dilute waste layers occurring higher in the tank. In these more dilute waste layers, the susceptibility to localized corrosion could potentially differ from that of the more concentrated salt solutions evaluated in previous testing, as the amount of inhibiting and aggressive species, not just the ratios, can affect susceptibility. Evaluation of the susceptibility to localized corrosion in these more dilute waste chemistries could provide insight into the amount of inhibitors required to effectively mitigate pitting corrosion in stagnant salt dissolution environments, as well as other tank farm operations involving dilute waste streams.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗