Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cosmic ray composition & spectra”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Cosmic Ray Energetics and Mass (CREAM)

The CREAM instrument was flown on a Long Duration Balloon in Antarctica in December 2004 and January 2005, achieving a flight duration record of nearly 42 days. It detected and recorded cosmic ray primary particles ranging in type from hydrogen to iron nuclei and in energy from 1 TeV to several hundred TeV. With the data collected we will have the world's best measurement of the energy spectra and mass composition of nuclei in the primary cosmic ray flux at these energies, close to the astrophysical knee . The instrument utilized a thin calorimeter, a transition radiation detector and a timing charge detector, which also provided time-of-flight information. The responsibilities of our group have been with the timing charge detector (TCD), and with the data acquisition electronics and ground station support equipment. The TCD utilized fast scintillators to measure the charge of the primary cosmic ray before any interactions could take place within the calorimeter. The data acquisition electronics handled the output of the various detectors, in a fashion fully integrated with the payload bus. A space-qualified flight computer controlled the acquisition, and was used for preliminary trigger information processing and decision making. Ground support equipment was used to monitor the health of the payload, acquire and archive the data transmitted to the ground, and to provide real-time control of the instrument in flight.

Coutu, Stephane↗

A particle astrophysics magnet facility: ASTROMAG

The primary scientific objectives of ASTROMAG are to: examine cosmological models by searching for antimatter and dark matter candidates; study the origin and evolution of matter in the galaxy by direct sampling of galactic matter; and study the origin and acceleration of the relativistic particle plasma in the galaxy and its effects on the dynamics and evolution of the galaxy. These general scientific objectives will be met by ASTROMAG with particle detection instruments designed to make the following observations: search, for anti-nuclei of helium and heavier element; measure the spectra of anti-protons and positrons; measure the isotopic composition of cosmic ray nuclei at energies of several GeV/amu; and measure the energy spectra of cosmic ray nuclei to very high energies.

Ormes, Jonathan F.↗

Cosmic Ray Nuclei (CRN) detector investigation

The Cosmic Ray Nuclei (CRN) detector was designed to measure elemental composition and energy spectra of cosmic radiation nuclei ranging from lithium to iron. CRN was flown as part of Spacelab 2 in 1985, and consisted of three basic components: a gas Cerenkov counter, a transition radiation detector, and plastic scintillators. The results of the experiment indicate that the relative abundance of elements in this range, traveling at near relativistic velocities, is similar to those reported at lower energy.

Meyer, Peter↗

Direct Measurement of the Nickel Spectrum in Cosmic Rays in the Energy Range from 8.8 GeV/$\mathcal{n}$ to 240 GeV/$\mathcal{n}$ with CALET on the International Space Station

The relative abundance of cosmic ray nickel nuclei with respect to iron is by far larger than for all other transiron elements; therefore it provides a favorable opportunity for a low background measurement of its spectrum. Since nickel, as well as iron, is one of the most stable nuclei, the nickel energy spectrum and its relative abundance with respect to iron provide important information to estimate the abundances at the cosmic ray source and to model the Galactic propagation of heavy nuclei. However, only a few direct measurements of cosmic-ray nickel at energy larger than ~ 3 GeV/n are available at present in the literature, and they are affected by strong limitations in both energy reach and statistics. In this Letter, we present a measurement of the differential energy spectrum of nickel in the energy range from 8.8 to 240 GeV/n , carried out with unprecedented precision by the Calorimetric Electron Telescope (CALET) in operation on the International Space Station since 2015. The CALET instrument can identify individual nuclear species via a measurement of their electric charge with a dynamic range extending far beyond iron (up to atomic number Z = 40 ). The particle’s energy is measured by a homogeneous calorimeter (1.2 proton interaction lengths, 27 radiation lengths) preceded by a thin imaging section (3 radiation lengths) providing tracking and energy sampling. This Letter follows our previous measurement of the iron spectrum [O. Adriani et al. (CALET Collaboration), Phys. Rev. Lett. 126, 241101 (2021).], and it extends our investigation on the energy dependence of the spectral index of heavy elements. It reports the analysis of nickel data collected from November 2015 to May 2021 and a detailed assessment of the systematic uncertainties. In the region from 20 to 240 GeV/n our present data are compatible within the errors with a single power law with spectral index -2.51 ± 0.07 .

79 ASTRONOMY AND ASTROPHYSICS↗

Advanced Thin Ionization Calorimeter (ATIC) Balloon Experiment

During grant NAG5-5064, Louisiana State University (LSU) led the ATIC team in the development, construction, testing, accelerator validation, pre-deployment integration and flight operations of the Advanced Thin Ionization Calorimeter (ATIC) Balloon Experiment. This involved interfacing among the ATIC collaborators (UMD, NRL/MSFC, SU, MSU, WI, SNU) to develop a new balloon payload based upon a fully active calorimeter, a carbon target, a scintillator strip hodoscope and a pixilated silicon solid state detector for a detailed investigation of the very high energy cosmic rays to energies beyond 10(exp 14) eV/nucleus. It is in this very high energy region that theory predicts changes in composition and energy spectra related to the Supernova Remnant Acceleration model for cosmic rays below the "knee" in the all-particle spectrum. This report provides a documentation list, details the anticipated ATIC science return, describes the particle detection principles on which the experiment is based, summarizes the simulation results for the system, describes the validation work at the CERN SPS accelerator and details the balloon flight configuration. The ATIC experiment had a very successful LDB flight from McMurdo, Antarctica in 12/00 - 1/01. The instrument performed well for the entire 15 days. Preliminary data analysis shows acceptable charge resolution and an all-particle power law energy deposition distribution not inconsistent with previous measurements. Detailed analysis is underway and will result in new data on the cosmic ray charge and energy spectra in the GeV - TeV energy range. ATIC is currently being refurbished in anticipation of another LDB flight in the 2002-03 period.

Wefel, John P.↗

On the propagation of cosmic rays in the Galaxy

Cosmic ray propagation in the Galaxy is examined within the framework of the leaky-box model, whereby phenomenological aspects of diffusion and propagation are related to the physical properties of the interstellar medium. The model is parameterized by data on composition, spectra, spectral change as a function of energy, and cosmic ray particle lifetime. It is assumed that electrons and nucleons have a common source within the Galaxy (probably associated with supernova remnants). Lifetime data and leakage length are compared with radio synchrotron and gamma-ray data to establish a place of origin for cosmic rays observed at earth, i.e., at a radius of 0.5-1.0 kpc from earth. It is noted that if the escape length becomes energy independent, all nuclear spectra will flatten, while the electron spectrum remains unchanged.

Ormes, J.↗

Voyager measurements of the energy spectrum, charge composition, and long term temporal variations of the anomalous components in 1977-1982

The large collecting area and wide energy range of the cosmic ray experiment on Voyager 1 and 2 was used to examine the energy spectra, charge composition, and long term temporal variations of the anomalous components in 1977-1982. Individual energy spectra are obtained for 17 separate quiet time periods during the time interval. The composite spectra of anomalous He, N, O, and Ne are obtained to a new level of precision. This includes the spectral shape and the relative abundance. Essentially, the spectral shape of N, O, and Ne appear to be similar. The ratios of anomalous N and Ne to O are found to be different from both the solar cosmic ray and galactic cosmic ray source composition. Some evidence is found for the enhancement of Ar as well. In the case of elements such as C, Mg, S, and Fe it is difficult to separate a possible lower intensity anomalous component from a quasi-steady interplanetary component that appears to be present at the lowest energies. The long term temporal variations of the anomalous He and O components were studied from 1977-82, a period from minimum to maximum in the modulation cycle. The tracking between these anomalous component intensities and the integral intensity of 75 MeV protons is striking; however, the intensity decrease of the anomalous components is much greater.

Webber, W. R.↗

Studies of low-energy Galactic cosmic-ray composition at 22 AU. I - Secondary/primary ratios

Data from the High Energy Telescope of the CRS experiment on Voyager 2 have been used to measure the intensity, spectra, and elemental abundances of Galactic cosmic rays from Be to Ni at about 100 MeV/n. The charge resolution of this telescope varies from sigma = 0.034 for oxygen to sigma = 0.11 for iron. The solar modulation deceleration parameter Phi relevant for these data is estimated to be around 300 MV (Phi = 150 MeV/n for particles with A/Z = 2), an unprecedently low level for such measurements. This low modulation parameter is a result of the measurements being made in the outer heliosphere at a heliocentric distance of 22 AU, and centered on the solar minimum period of cycle 21. The results on secondary/primary ratios are used to test the Leaky-Box model of cosmic ray propagation, using the most recent cross sections data in hydrogen and helium, and taking into account the effects of the ionized fraction of the interstellar medium. It is found that all the secondary/primary ratios up to P/S are completely consistent with an exponential pathlength distribution (PLD). This PLD shape also accounts for the Sc-V/Fe ratio.

Ferrando, P.↗

The composition of cosmic rays at high energies

Measurements of the composition of the cosmic rays at high energies, and of the energy spectra of the individual components provide the basis for the understanding of the sources, of the acceleration mechanism, and of the galactic containment of these particles. A brief review of the presently available information and a recent measurement performed on the Space Shuttle to substantially extend the range of energies in which the elemental composition is known are described. Results, and recent data on the electron component of cosmic rays are discussed and summarized. The body of data now available contains several features that are difficult to explain within current models of galactic shock acceleration and 'leakly box' containment. The need for further measurements is emphasized and possible opportunities for future work are briefly discussed.

Muller, Dietrich↗

Rigidity Spectra of Protons and Helium as Measured in the First Flight of the ATIC Experiment

ATIC (Advanced Thin Ionization Calorimeter) is a balloon borne experiment designed to measure cosmic ray composition for elements from hydrogen to iron and their energy spectra from 30 GeV to near 100 TeV. It is comprised of a fully active BGO calorimeter, a carbon interaction target, scintillator hodoscopes, and a silicon matrix that is used as a charge detector in the experiment. ATIC had two successful balloon flights in Antarctica: from 28 Dec 2000 to 13 Jan 2001 (ATIC-1) and from 29 Dec 2002 to 18 Jan 2003 (ATIC-2). Preliminary rigidity spectra of protons and helium nuclei and their ratio are presented for the test flight (ATIC-1). Particular attention is given to problems associated with measuring energy.

Zatsepin, V. I.↗

Energy spectra of cosmic-ray nuclei from 50 to 2000 GeV per amu

A direct measurement of the elemental composition of cosmic rays up to energies of several TeV/amu was performed during the Spacelab 2 flight of the Space Shuttle. Results on the spectral shape for the elements C, O, Ne, Mg, Si, and Fe, obtained from this experiment, are presented. It was found that the C and O energy spectra retain a power-law spectrum in energy with an exponent Gamma of about 2.65. The Fe spectrum is flatter (Gamma of about 2.55) up to a particle energy of about 10 to the 14th eV, indicating a steady increase in the relative abundance of iron in cosmic rays up to this energy. The energy spectra of Ne, Mg, and Si are steeper than anticipated. This behavior is unexpected within current models of cosmic-ray acceleration.

Grunsfeld, John M.↗

Refractory nuclides in the cosmic-ray source

New observations of the abundances and energy spectra of the isotopes of Mg, Al, and Si from ACE/CRIS are used to extend our previous results on the composition of refractory nuclides in cosmic-ray source material.

cosmic rays composition heavy nuclei↗

First Flight of the Advanced Thin Ionization Calorimeter (ATIC) Balloon Experiment

The ATILT instrument is designed to measure the composition and energy spectra of Z = 1 to 28 cosmic rays over the energy range -10 GeV - 100 TeV. ATIC was launched as a long duration test balloon flight on 12/28/00 local time from McMurdo, Antarctica. The operations preceding and during launch went very smoothly. During the first -20 hr while the instrument remained within line of sight (LOS), a full system check out was conducted, the experiment was operated in several test configurations, and all major tuning was completed. Preliminary analysis of the science data indicates that the overall detector system is functioning as expected. With our fully functioning analysis software we were able to monitor the data in nearly real time. Each event was reconstructed event-by-event to confirm the detector performance. The shower profiles indicate that the shower maximum location is deeper in the calorimeter for higher energy events, as expected. The energy spectra of protons, Helium nuclei, and "all particles" appear to follow power laws. Both the Si matrix and top scintillator layer of the charge module show clear charge separation for p and He. As the statistics increase, heavy nuclei charge separation will be evaluated. We will present preliminary results of the LOS data, as well as other data that will be available from the flight-data hard disk,

Case, G.↗

Preliminary Results From The First Flight of ATIC

The Advanced Thin Ionization Calorimeter (ATIC) instrument is designed to measure the composition and energy spectra of Z = 1 to 28 cosmic rays over the energy range approximately 10 GeV - 100 TeV. The instrument was calibrated in September 1999 at CERN using accelerated electron, proton and pion beams. ATIC was launched as a long duration balloon test flight on 12/28/00 local time from McMurdo, Antarctica. After flying successfully for about 16 days the payload was recovered in excellent condition. Absolute calibration of the detector response was made using cosmic-ray muons. The data analysis algorithm which was developed with Monte Carlo simulations and validated with the CERN beam test will be used for the flight data analysis. Preliminary results of the proton and helium spectra will be reported in this paper.

Seo, E. S.↗

Advanced Thin Ionization Calorimeter (ATIC) Update

The Advanced Thin Ionization Calorimeter (ATIC) experiment is designed to measure the composition and energy spectra of Z = 1 to 28 cosmic rays over the energy range of approximately 10 GeV - 100 TeV. ATIC is comprised of an eight-layer, 18 radiation length deep Bismuth Germanate (BGO) calorimeter, downstream of a 0.75 nuclear interaction length graphite target and an approximately 1 sq m finely segmented silicon charge detector. Interleaved with the graphite layers are three scintillator strip hodoscopes for pre-triggering and tracking. ATIC flew for the first time on a Long Duration Balloon (LDB) launched from McMurdo, Antarctica in January 2001. During its 16-day flight ATIC collected more than 30 million science events, along with housekeeping, calibration, and rate data. This presentation will describe the ATIC data processing, including calibration and efficiency corrections, and show results from analysis of this dataset. The next launch is planned for December 2002.

Ahn, H. S.↗

Atic Experiment: Flight Data Processing

The Advanced Thin Ionization Calorimeter (ATIC) is a balloon borne experiment to measure the composition and energy spectra of Z = 1 to 28 cosmic rays over the energy range approx. 30 GeV - 100 TeV. The instrument consists of a fully active 320-crystal Bismuth Germanate (BGO) calorimeter, 202 scintillator strips in 3 hodoscopes interleaved with a graphite target, and a 4480-pixel silicon matrix charge detector. ATIC has had two successful Long Duration Balloon flights from McMurdo, Antarctica: from 12/28/00 to 01/13/01 and from 12/29/02 to 01/18/03. We have developed the ATIC Data Processing System (ADPs), which is an Object Oriented data processing program based on ROOT. In this paper, we describe the processing scheme used in handling the flight data, especially the calibration method and the event reconstruction algorithm.

Ahn, H. S.↗

Elemental Spectra from the First ATIC Flight

The Advanced Thin Ionization Calorimeter (ATIC) instrument is a balloon-borne experiment designed to measure the composition and energy spectra of Z = l to 26 cosmic rays over the energy range from approx. 10(exp 11) to approx. 10(exp 14) eV. The instrument consists of a silicon matrix charge detector, plastic scintillator strip hodoscopes interleaved with graphite interaction targets, and a fully active Bismuth Germanate (BGO) calorimeter. ATIC had two successful Long Duration Balloon flights launched from McMurdo Station, Antarctica in 2000 and 2002. In this paper, spectra of various elements measured during the first 16 day flight are presented.

Ahn, H. S.↗