At least 109 records · Page 6

Cryogenic Fluid Management Technology Development Roadmaps

Advancement in Cryogenic Fluid Management (CFM) Technologies is essential for achieving NASA's future long duration missions. Propulsion systems utilizing cryogens are necessary to achieve mission success. Current State Of the Art (SOA) CFM technologies enable cryogenic propellants to be stored for several hours. However, some envisioned mission architectures require cryogens to be stored for two years or longer. The fundamental roles of CFM technologies are long term storage of cryogens, propellant tank pressure control and propellant delivery. In the presence of heat, the cryogens will "boil-off" over time resulting in excessive pressure buildup, off-nominal propellant conditions, and propellant loss. To achieve long term storage and tank pressure control, the CFM elements will intercept and/or remove any heat from the propulsion system. All functions are required to perform both with and without the presence of a gravitational field. Which CFM technologies are required is a function of the cryogens used, mission architecture, vehicle design and propellant tank size. To enable NASA's crewed mission to the Martian surface, a total of seventeen CFM technologies have been identified to support an In-Space Stage and a Lander/Ascent Vehicle. Recognizing that FY2020 includes a Decision Point regarding the In-Space Stage Architecture, a set of CFM Technology Development Roadmaps have been created identifying the current Technology Readiness Level (TRL) of each element, current technology "gaps", and existing technology development efforts. The roadmaps include a methodical approach and schedule to achieve a flight demonstration in FY2023, hence maturing CFM technologies to TRL 7 for infusion into the In-Space Stage Preliminary Design.

Stephens, J. R.↗

Experimental Thermal Performance Testing of Cryogenic Tank Systems and Materials

A comparative study was conducted to collect and analyze thermal conductivity data on a wide variety of low density materials, as well as thermal performance data on a number of vacuum-jacketed cryogenic tank systems. Although a vast number of these types of materials and cryogenic tank systems exist, the thermal conductivity of insulation materials and the thermal performance of cryogenic tank systems is often difficult to compare because many industrial methods and experimental conditions are available and utilized. The availability of a new thermal conductivity measurement device, the Macroflash Cup Cryostat, which is applicable for assessing a variety of materials, is accessible at NASA's Cryogenic Test Laboratory (CTL) at the Kennedy Space Center (KSC). The convenience of this device has resulted in the ability to rapidly measure the thermal conductivity properties of these materials by using a flat-plate liquid nitrogen (LN2) boiloff technique that employs a guarded heat flow test methodology in order to determine the effective thermal conductivity (ke) of a test specimen. As the thermal conductivities are measured at cryogenic temperatures, materials suitable for both future space missions and cryogenic tank systems can be identified and experimentally analyzed. Also recognizable are materials which may help increase energy efficiency by limiting the thermal losses encountered under various environmental conditions. The overall focus of this work consisted of two parts. One part, was to produce and analyze thermal conductivity data on a wide variety of materials with suitable properties conducive to those needed to aid in the production of a calibration curve for the "low end" of the Macroflash instrument. (Low end meaning materials with a thermal conductivity rating below 100 milliwatts per meter-Kelvin). The second part was to collect and analyze heat transfer data for a variety of small vacuum-jacketed vessels (cryogenic tank systems) in order to compare the thermal performance between them.

Myers, Wesley C.↗

Design Guide for Bearings Used in Cryogenic Turbopumps and Test Rigs

Cryogenic bearings are a unique and specialized area of the overall group of bearings that are used every day in industrial and aerospace applications. Cryogenic bearings operate in a unique environment that is not experienced by most bearing applications. The high speeds of turbomachinery, flow of cryogenic coolants, use of nonstandard materials, and lack of lubrication place unique demands on cryogenic bearings that must be met for the safety and success of the mission. To meet the goals of safety and success, requirements are put on the designer, manufacturer, and user that are not normally applied to off-the-shelf bearings. The designer has to have knowledge of the operating conditions, rotational speeds, loads, stresses, installation methods, inspection criteria, dimensional requirements, and design and analytical tools. The manufacturer needs to be aware of the materials used for cryogenic bearings, special heat treatments required, cleanliness of the processes, and inspection techniques to ensure a good product. The user needs to be aware of the safe handling practices to eliminate corrosion and debris, correct installation and removal procedures, pre- and post-test inspections, and the documentation that follow the bearings. This guide is based on the experiences of engineers at NASA Marshall Space Flight Center (MSFC) that have been involved in bearing research and testing along with specific bearing references that have been written. It is not meant to be a bearing design textbook for cryogenic bearing applications. These are available from many authors. Its purpose is to help the designer, manufacturer, or user in the application of cryogenic bearings to better understand the requirements placed on these bearings.

H. G. Gibson↗

Designing a Decontamination Solution for the Low-Earth-Orbit, Cryogenic SPHEREx Mission

To address the scientific goals of NASA’s astrophysics division, the JPL and Caltech’s SPHEREx mission conducts the first near-infrared all-sky spectral survey in low-earth-orbit using a passively-cooled, cryogenic telescope. Several unique water contamination issues arise due to the combination of cryogenic operation temperatures and the limited temperature control authority of passive cooling. Because water molecules have adsorption bands within the wavelengths of interest for SPHEREx’s survey, it is imperative that water contamination be controlled and minimized. In this work, a model is developed for the SPHEREx mission to predict the transport and accumulation of outgassed water onto sensitive payload components. The model utilizes the time dependent thermal profiles of the individual payload components, initial water content, and spacecraft geometry to calculate the time dependent water diffusion, transport, and adsorption. This model is subsequently used to predict water contamination risks and design decontamination solutions for each risk. Two major water contamination risks were predicted, water accumulation during cooldown and on cryogenic surfaces during the mission. The first risk occurs during the cooldown of the payload to cryogenic temperatures, predicting water accumulation on optical surfaces in excess of the allowable levels. To mitigate this accumulation, the temperature of the optical surfaces is controlled during cooldown through a combination of heaters and spacecraft pointing. The second risk is that over the course of the mission, is unavoidable water accumulation onto the payload thermal system’s cryogenic surfaces, possibly jeopardizing thermal performance and temperature stability, both of which are required for science success. To decontaminate any water that had collected onto cryogenic thermal system surfaces, a decontamination maneuver was designed. In this decontamination maneuver, cryogenic surfaces of the thermal system are warmed to a temperature where water will desorb by spacecraft pointing while still meeting all avoidance constraints, and thereby avoiding undue risk to the observatory hardware. Through application of the developed analytical model and inclusion of the decontamination maneuver in the mission design, SPHEREx can confidently demonstrate that it is able to decontaminate, at the start of and during the mission as needed to meet its end of life science performance requirements.

Soares, Carolos E.↗

Experimental Observations on Material Damping at Cryogenic Temperatures

This paper describes a unique experimental facility designed to measure damping of materials at cryogenic temperatures for the Terrestrial Planet Finder (TPF) mission at the Jet Propulsion Laboratory. The test facility removes other sources of damping in the measurement by avoiding frictional interfaces, decoupling the test specimen from the support system, and by using a non-contacting measurement device. Damping data reported herein are obtained for materials (Aluminum, Aluminum/Terbium/Dysprosium, Titanium, Composites) vibrating in free-free bending modes with low strain levels (< 10(exp -6) ppm). The fundamental frequencies of material samples are ranged from 14 to 202 Hz. To provide the most beneficial data relevant to TPF-like precision optical space missions, the damping data are collected from room temperatures (around 293 K) to cryogenic temperatures (below 40 K) at unevenly-spaced intervals. More data points are collected over any region of interest. The test data shows a significant decrease in viscous damping at cryogenic temperatures. The cryogenic damping can be as low as 10(exp -4) %, but the amount of the damping decrease is a function of frequency and material. However, Titanium 15-3-3-3 shows a remarkable increase in damping at cryogenic temperatures. It demonstrates over one order of magnitude increase in damping in comparison to Aluminum 6061-T6. Given its other properties (e.g., good stiffness and low conductivity) this may prove itself to be a good candidate for the application on TPF. At room temperatures, the test data are correlated well with the damping predicted by the Zener theory. However, large discrepancies at cryogenic temperatures between the Zener theory and the test data are observed.

Terrestrial Planet Finder (TPF)↗

Miniature Cryogenic Valves for a Titan Lake Sampling System

The Cassini mission has revealed Titan to be one of the most Earthlike worlds in the Solar System complete with many of the same surface features including lakes, river channels, basins, and dunes. But unlike Earth, the materials and fluids on Titan are composed of cryogenic organic compounds with lakes of liquid methane and ethane. One of the potential mission concepts to explore Titan is to land a floating platform on one of the Titan Lakes and determine the local lake chemistry. In order to accomplish this within the expected mass volume and power budgets there is a need to pursue the development for a low power lightweight cryogenic valves which can be used along with vacuum lines to sample lake liquid and to distribute to various instruments aboard the Lander. To meet this need we have initiated the development of low power cryogenic valves and actuators based on a single crystal piezoelectric flextensional stacks produced by TRS Ceramics Inc. Since the origin of such high electromechanical properties of Relaxor-PT single crystals is due to the polarization rotation effect, (i.e., intrinsic contributions), the strain per volt decrease at cryogenic temperatures is much lower than in standard Lead Zirconate Titanate (PZT) ceramics. This makes them promising candidates for cryogenic actuators with regards to the stroke for a given voltage. This paper will present our Titan Lake Sampling and Sample Handling system design and the development of small cryogenic piezoelectric valves developed to meet the system specifications.

Piezoelectric Devices↗

Axisymmetric Two-Dimensional Modeling of No Vent Filling of a Cryogenic Tank using Generalized Fluid System Simulation Program

Filling a tank with cryogenic fluid is more challenging than filling a tank with water or any other fluid that is in liquid state at atmospheric condition. Filling a tank with cryogenic fluid is a two-step process. First the tank and the transfer line mustbe chilled. Liquid cryogens start flowing into the tank only after the tank and transfer lines are chilled to the fluid saturation temperature. In normal gravity, cryogenic tanks are usually filled from the bottom at nearly atmospheric pressure. The vapor, caused by heat transfer from the warm tank walls, is allowed to vent from the top of the tank while the tank is being filled. Filling a cryogenic tank in the absence of gravity is more challenging because in a non-stratified environment liquid propellantmay not settle at the tank bottom as it does on earth. There is a strong possibility that liquid propellant may exit through the vent valve, which is typically located at the top of the tank to vent propellant vapor. There are several methodsof filling atank in space: Charge-Hold-Vent method [1], Vented-Chill / No-Vent-Fill (VCNVF)[2],and No Vent Fill with TVS assisted injector [3].This paper addressesnumerical modelingofthe No Vent Fill (NVF) processwhere a TVS (Thermodynamic Vent System) augmented injector was used with the vent valve closed during the entire filling process. NVF tests were conducted in the CRYOgenic Orbital Testbed (CRYOTE) tankat NASA/Marshall Space Flight Centerin 2018.The Generalized Fluid System Simulation Program (GFSSP), a general-purpose flow network code [4] was used to simulate the chilland fill process.

Cryogenics↗

Validation of Universal Cryogenic Flow Boiling Correlations in Thermal Desktop for Liquid Hydrogen

Developing accurate models of two-phase cryogenic flow will reduce risk and reduce margins for future NASA vehicles such as the Nuclear Thermal Propulsion (NTP) system. Currently there is a need for more accurate, direct cryogenic data-anchored models for various boiling and two-phase phenomena. The focus of the current work is on modeling steady state cryogenic flow boiling in the transfer line that connects a propellant storage tank to an engine or customer receiver tank. This paper presents Thermal Desktop model validation results against several historical liquid hydrogen (LH2) heated tube experiments that cover a wide range of inlet conditions, mass flux, and heat flux. New universal cryogenic flow boiling correlations were recently developed and anchored to the largest cryogenic flow boiling database assembled in the world to-date. The new universal correlations are patched together and implemented into Thermal Desktop to compare model performance against the built-in flow boiling correlations. Axial wall temperature predictions as a function of preponderant parameters like heat flux, mass flux, inlet pressure, inlet quality, tube diameter, etc. using the two sets of flow boiling correlations are compared against the experimental data. Overall, the Thermal Desktop model with the new universal cryogenic flow boiling correlations demonstrates an improvement in predictive performance over the Thermal Desktop model using built-in correlations for both wall temperature and location of critical heat flux compared to the data for LH2 flow boiling in heated tubes.

Cryogenic Propellant Transfer↗

Validation of Universal Cryogenic Flow Boiling Correlations in Thermal Desktop for Liquid Hydrogen

Developing accurate models of two-phase cryogenic flow will reduce risk and reduce margins for future NASA vehicles such as the Nuclear Thermal Propulsion (NTP) system. Currently there is a need for more accurate, direct cryogenic data-anchored models for various boiling and two-phase phenomena. The focus of the current work is on modeling steady state cryogenic flow boiling in the transfer line that connects a propellant storage tank to an engine or customer receiver tank. This paper presents Thermal Desktop model validation results against several historical liquid hydrogen (LH2) heated tube experiments that cover a wide range of inlet conditions, mass flux, and heat flux. New universal cryogenic flow boiling correlations were recently developed and anchored to the largest cryogenic flow boiling database assembled in the world to-date. The new universal correlations are patched together and implemented into Thermal Desktop to compare model performance against the built-in flow boiling correlations. Axial wall temperature predictions as a function of preponderant parameters like heat flux, mass flux, inlet pressure, inlet quality, tube diameter, etc. using the two sets of flow boiling correlations are compared against the experimental data. Overall, the Thermal Desktop model with the new universal cryogenic flow boiling correlations demonstrates an improvement in predictive performance over the Thermal Desktop model using built-in correlations for both wall temperature and location of critical heat flux compared to the data for LH2 flow boiling in heated tubes.

cryogenic propellant transfer↗

Spacecraft cryogenic gas storage systems

Cryogenic gas storage systems were developed for the liquid storage of oxygen, hydrogen, nitrogen, and helium. Cryogenic storage is attractive because of the high liquid density and low storage pressure of cryogens. This situation results in smaller container sizes, reduced container-strength levels, and lower tankage weights. The Gemini and Apollo spacecraft used cryogenic gas storage systems as standard spacecraft equipment. In addition to the Gemini and Apollo cryogenic gas storage systems, other systems were developed and tested in the course of advancing the state of the art. All of the cryogenic storage systems used, developed, and tested to date for manned-spacecraft applications are described.

Rysavy, G.↗

Development and validation of a hybrid-computer simulator for a transonic cryogenic wind tunnel

A study was undertaken to model the cryogenic wind tunnel process, to validate the model by the use of experimental data from the Langley 0.3 Meter Transonic Cryogenic Tunnel, and to construct an interactive simulator of the cryogenic tunnel using the validated model. Additionally, this model was used for designing closed loop feedback control laws for regulation of temperature and pressure in the 0.3 meter cryogenic tunnel. The global mathematical model of the cryogenic tunnel that were developed consists of coupled, nonlinear differential governing equations based on an energy state concept of the physical cryogenic phenomena. Process equations and comparisons between actual tunnel responses and computer simulation predictions were examined. Also included are the control laws and simulator responses obtained using the feedback schemes for closed loop control of temperature and pressure were also included.

Thibodeaux, J. J.↗

Minimum Energy Test Direction Design in the Control of Cryogenic Wind Tunnels

The advent of the cryogenic wind tunnel concept is attributable to the need for high Reynolds number flow in wind tunnels. The cryogenic wind tunnel concept consists of operating the test medium of a conventional tunnel at cryogenic temperatures down to 80 K. Nitrogen gas, cooled by injected liquid nitrogen, proves to be ideal for the cryogenic tunnel test medium because of its near perfect behavior in insentropic flow. Cryogenic operation of a wind tunnel results in reduced fan power consumption and no penalty in flow dynamic pressure. In a cryogenic tunnel, the flow parameters (Reynolds number, Mach number and flow dynamic pressure) can be independently controlled by separately controlling the tunnel flow variables: total temperature, test section mass flow, and the tunnel total pressure. The problem of closed-loop control of the tunnel total temperature, flow Mach number, and total pressure is addressed and reported.

Balakrishna, S.↗

Latest developments in cryogenic safety

The Cryogenic Safety Manual, sponsored by the British Cryogenics Council, was published over 10 years ago. A new updated version is now available. Some general aspects of cryogenic safety are highlighted, and attention is drawn to some of the more unusual hazardous situations. An awareness of the physical properties of the cryogenic fluids being dealt with is important in directing attention to hazardous situations which may arise. Because of this, the more important properties of the cryogenic fluids are given, such as molecular weight, boiling point and freezing point. From these properties, hazardous situations can be deduced. There are hidden dangers that are not always easy to spot. Some of the unexpected hazards, most of which have led to deaths, are: asphyxiation (anoxia), frost bites and hypothermia, explosions, and combustion. The aim of this publication is to help bring about increased safety in the production and use of cryogenic products through a deeper appreciation of the scientific, technological and administrative steps which must be made if accidents, some fatal, are to be voided in the future.

Webster, T. J.↗

Cryogenic optical systems and instruments II; Proceedings of the Meeting, Los Angeles, CA, Jan. 23, 24, 1986

The topics of the present conference encompass cryogenic optical system design considerations, cryogenic instruments and their components, the design and performance of cryogenic dewars for space, and technologies supporting cryogenic systems and instruments. Attention is given to the Space IR Telescope Facility (SIRTF) observatory's design and on-orbit servicing, hardware development for the Gravity Probe-B program, the multiband imaging photometer aboard SIRTF, and the SIRTF wide field, diffraction-limited array camera. Also discussed are the cryogenic star-tracking telescope for Gravity Probe-B, a balloon-borne spectrometer for measurement of lower stratospheric trace constituents, the primary mirror support system design for a cryogenic space telescope, and the SQUID readout and ultralow magnetic fields of Gravity Probe-B.

Melugin, Ramsey K.↗

Safety and cryogenic wind tunnels

The Langley 0.3-Meter Transonic Cryogenic Tunnel (0.3-m TCT) was placed in operation at NASA's Langley Research Center in 1973 as the world's first cryogenic pressure tunnel. The 0.3-m TCT can operate from ambient to cryogenic temperatures over an absolute pressure range from about 1 to 6 atmospheres. Three major test section concepts were developed and refined in this unique facility. The 0.3-m TCT is a leader in the development of various cryogenic pressure wind tunnel experimental techniques, instrumentation, control, model technology and safety standards. The safety experience gained is examined. During this period of advanced research, new operating techniques, training policies, and procedures had to be established. The paper deals with the Do's and Don'ts of cryogenic wind tunnel testing. Hazards and safety requirements which are unique to cryogenic testing are discussed. Highlights of experience and lessons learned with the 0.3-m TCT are reviewed.

Ray, Edward J.↗

Study to identify future cryogen payload elements/users for space shuttle launch during period 1990 to 2000

This study provides a summary of future cryogenic space payload users, their currently projected needs and reported planning for space operations over the next decade. At present, few users with payloads consisting of reactive cryogens, or any cryogen in significant quantities, are contemplating the use of the Space Shuttle. Some members of the cryogenic payload community indicated an interest in flying their future planned payloads on the orbiter, versus an expendable launch vehicle (ELV), but are awaiting the outcome of a Rockwell study to define what orbiter mods and payloads requirements are needed to safely fly chemically reactive cryogen payloads, and the resultant cost, schedule, and operational impacts. Should NASA management decide in early 1990 to so modify orbiter(s), based on the Rockwell study and/or changes in national defense payloads launch requirements, then at least some cryo payload customers will reportedly plan on using the Shuttle orbiter vehicle in preference to an ELV. This study concludes that the most potential for possible future cryogenic space payloads for the Space Transportation System Orbiter fleet lies within the scientific research and defense communities.

Elim, Frank M.↗

Space Cryogenics Workshop, 10th, Cleveland, OH, June 18-20, 1991, Proceedings

The present workshop on cryogenics discusses the anomalous on-orbit behavior of the Cosmic Background Explorer Dewar, the SHOOT orbital operations, cooling options for Astromag, and space IR telescope facility mission and cryogenic design. Attention is given to the design of a spaceworthy adiabatic demagnetization refrigerator, the evaluation of metal hydride compressors for applications in Joule-Thomson cryocoolers, diaphragm Stirling cryocooler developments, and a computer simulation model for Stirling refrigerators. Topics addressed include low-gravity thermal stratification of liquid helium on SHOOT, a screening program to select a resin for gravity probe-B composites, a simplified generic cryostat thermal model for predicting cryogen mass and lifetime, and the effect of gas mass flux on cryogenic liquid jet breakup. Also discussed are damping criteria for thermal acoustic oscillations in slush and liquid hydrogen systems, an STS-based cryogenic fluid management experiment, and the design and testing of a cryogenic mixer pump.

Source record↗

Final cryogenic performance report for the NASA Cosmic Background Explorer (COBE)

The cryogenic operation of NASA's Cosmic Background Explorer (COBE) ended on September 21, 1990, with the depletion of the liquid helium cryogen. The COBE had successfully completed more than 10 months of dewar and instrument operation. We report on the cryogenic performance of the COBE dewar and of the two cryogenic instruments throughout the mission lifetime. We discuss the steady state dewar performance, and the dewar and instrument response to a variety of transient thermal phenomena, including external radiation (from the earth and the sun) and instrument power variation. We present the effectiveness of using approximate mass gauging techniques in determining the liquid helium content. Finally we discuss the dewar behavior during the depletion of the helium, and the expected thermal performance of the dewar cryogen tank and the cryogenic instruments as they approach final thermal equilibrium.