LBNF/DUNE Cryostats and Cryogenics Infrastructure for the DUNE Far Detector (Design Report)

DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on both a near detector and a cryogenic far detector. The DUNE far detector implements liquid argon time-projection chamber (LArTPC) technology, and combines many tens-of-kilotons of fiducial mass with sub-centimeter spatial resolution to collect neutrino events and image them with high precision. Given its size, this detector will be implemented as a set of up to four modules, each of which will require its own cryostat that will contain approximately 17.5 metric kilotons of ultra-pure liquid argon (LAr). The cryogenics infrastructure to support the detector modules includes systems to receive, transfer, store, purify, and maintain the LAr. This design report describes the cryostats and the cryogenics infrastructure required for the first two detector modules; this infrastructure is designed to support expansion to up to four far detector modules.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advancing 1D thermo-hydraulic tools for large cryogenic facilities

The Cryogenic Division at Fermilab develops large-scale cryogenic systems for particle accelerators and superconducting test facilities. To support design and diagnostics, a Python-based code was created to calculate pressure drops in components such as valves and pipes. This paper presents recent enhancements to the code, including new heat transfer functions that improve the accuracy of thermal and hydraulic predictions. The first application models pressure and temperature changes in PIP-II relief pipes, aiding pipe sizing and protecting relief valves. The second example analyzes heat load evolution in a pipe carrying sub-atmospheric helium, helping interpret temperature sensor data and understand gas return behavior to cold compressors. These improvements significantly expand the tool’s capabilities, offering a practical resource for designing and troubleshooting cryogenic systems under dynamic thermal and flow conditions.

Beckwith, Rosalyn [Fermilab]↗

Lessons from commissioning of the cryogenic system for the Short-Baseline Neutrino Detector at Fermilab

Results from commissioning and first year of operations of the cryogenic system of the Short-Baseline Neutrino Detector (SBND) and its membrane cryostat installed at the Fermi National Accelerator Laboratory are described. The SBND detector is installed in a 200 m3 membrane cryostat filled with liquid argon, which serves both as target and as active media. For the correct operation of the detector, the liquid argon must be kept in very stable thermal conditions while the contamination of electronegative impurities must be consistently kept at the level of small fractions of parts per billion. The detector is operated in Booster Neutrino Beams (BNB) at Fermilab for the search of sterile neutrinos and measurements of neutrino-argon cross sections. The cryostat and the cryogenic systems also serve as prototypes for the much larger equipment to be used for the LBNF/DUNE experiment. Since its installation in 2018-2023 and cooldown in spring of 2024, the cryostat and the cryogenic system have been commissioned to support the detector operations. The lessons learned through installation, testing, commissioning, cooldown, and initial operations are described.

Geynisman, Michael [Fermilab]↗

Cryogenic Performance of the SPT-SLIM Receiver

The South Pole Telescope Shirokoff Line Intensity Mapper (SPT-SLIM) is a millimeter-wave line-intensity mapping experiment, deployed on the South Pole Telescope (SPT) during the 2024-2025 Austral Summer season. This pathfinder experiment serves to demonstrate the on-sky operation of multi-pixel on-chip spectrometer technology. We present on the cryogenic performance of the SPT-SLIM receiver for this Year 1 observing campaign. The SPT-SLIM receiver utilizes an Adiabatic Demagnetization Referigerator (ADR) for cooling the focal plane of superconducting filterbank spectrometers to a temperature of 150mK. We demonstrate stable thermal performance of the focal plane module during observing operations in line with thermal modelling, enabling a cryogenic operation efficiency above 80%. We also report on the receiver control system design utilizing the Observatory Control System (OCS) platform for automated cryogenic operation on the SPT.

Young, Matthew [Fermilab]↗

Operational Experience of the NML Cryogenic Plant at the FAST Test Facility

The NML cryogenic plant cools two individually cryostated superconducting radio frequency (SRF) capture cavities and one prototype ILC cryomodule with eight SRF cavities. This complex accelerates electrons at 150 MeV for the Integrable Optics Test Accelerator (IOTA) ring, located at the Fermilab Accelerator Science and Technology (FAST) facility. The cryogenic plant is composed of two nitrogen precooled Tevatron satellite refrigerators, two Mycom 2016C compressors, a cryogenic distribution system, a Frick purifier compressor, two charcoal bed adsorber purifiers, and a liquid ring vacuum pump with a roots booster. The SRF cavities are immersed in a 2.0 K liquid helium bath, shielded with a 5 K gaseous helium shield and a liquid nitrogen cooled thermal shield. Since 2019, this R&D accelerator complex has gone through four science runs with an average duration of 12 months. Operational experience for each run, availability metrics, performance data and common outages are presented in this paper.

Wallace, Timothy [Fermilab] (ORCID:000900051589302↗

Designing Energy-Efficient Quantum Computers Through Prediction and Reduction of Cooling Requirements for Cryogenic Electronics

Quantum computing has been identified as a “wild card” by the International Energy Agency in predicting future global data center energy usage. This is primarily because both uncertainty in the extent to which quantum computing will be adopted, and uncertainty in the power consumption of individual quantum data centers. Unlike the classical counterparts, quantum computers need to be maintained at near absolute zero, requiring energy-intensive cryogenic cooling systems. Therefore, as quantum computers scale up from existing 50 qubit technology demonstrations to the 10,000 to 100,000 qubit systems that will be able to solve complex problems, the energy consumption of both the electronics and the required cooling systems will also increase. To predict this scaling, this work analyzes the energy requirements for both computation and cooling of quantum hardware. We show that the energy requirements for cooling of quantum computers is determined by several computing system parameters, including the number and type of physical qubits, the operating temperature, the packaging efficiency of the system, and the split between circuits operating at cryogenic temperatures and those operating at room temperature. The energy requirements can then be found based on thermal system parameters such as cooling efficiency and cryostat heat transfer. Analysis of these parameters shows that the energy required for cooling is significantly larger than that required for computation, a reversal from energy usage patterns seen in conventional computing. The results and discussions provide a road-map for creating energy efficient quantum computers through the selection of computer architectures and cryogenic system configurations that minimize cooling requirements.

energy efficiency↗

Gaseous hydrogen storage system with cryogenic supply

A gaseous hydrogen storage and distribution system with a cryogenic supply and a method for the cryogenic conversion of liquid hydrogen into high-pressure gaseous hydrogen are provided. The gaseous hydrogen storage and distribution system includes pressuring liquid hydrogen from a cryogenic tank using a low pressure liquid pump before vaporization within a relatively small vaporizer. The resulting high pressure gaseous hydrogen is transferred to a plurality of storage tanks at ambient temperature according to a desired fill sequence. The high pressure hydrogen gas is subsequently distributed from the storage tanks through a hydrogen fueling dispenser according to a desired dispensing sequence. The present system and method provide improvements in operational safety, eliminates the use of high pressure gas compressor, and minimizes boiling off and ventilation losses at a reduced cost when compared to existing thermal compression storage systems.

Feng, Zhili↗

Cryogenic EM Across Length Scales for Li Metal Anode Batteries

An interfacial understanding is necessary for developing strategies to commercialize high-energy density rechargeable lithium metal anode batteries, as currently, the lithium anode/electrolyte interface is unstable with prolonged cycling. We have used several strategies to improve the cycling performance of lithium metal anodes, including reducing the parasitic reactions between lithium metal and the electrolyte, and improving the electrodeposited lithium metal morphology. These strategies have generated unconclusive electrochemical data, that has required the need for nanoscale interfacial characterization of these solid-liquid interfaces. Our team has used the cryogenic transfer workflow developed by Leica in collaboration with cryo-SEM/FIB tools by Thermo Fisher Scientific to cross-section lithium metal anodes and intact coin cell batteries to observe the interfacial structures, lithium morphology, and failure mechanisms relative to changes in electrode contract pressure and electrolyte chemistry. Cross-sectional SEM images and EDS maps of the lithium metal anodes have provided a better understanding of the electrodeposited lithium morphology, quantity of 'dead' lithium metal, and quantity of solid electrolyte interphase material that has formed alongside the lithium metal. In understanding lithium metal battery failure at the system level, we used a cryogenic stage in a laser plasma FIB to cross-section through the coin cell's cap for imaging/mapping the entire battery stack under cryogenic conditions. The tools, methods, and results of these studies will be detailed in this presentation.

characterization↗

Rapid Cryogenic Electrical Characterization of Materials and Devices Using Gifford-McMahon Cryocoolers

Thin-film heterostructures are necessary building blocks for superconducting and phononic quantum computing devices. Many new generations of quantum hardware demand extensive materials research to optimize performances at cryogenic temperatures (below 10 K). Here, we demonstrate compact cryogenic measurement systems capable of reaching sub-10K temperatures in less than three hours with the ability to measure AC/DC resistance and dielectric properties of thin-film materials. Our platform utilizes Gifford-McMahon (GM) cryocoolers as effective tools for providing high throughput cooling-warming cycles. We successfully used the GM-based measurement systems to measure 1) the superconducting transition temperature for Nb thin films (T c ~7.8 K), and 2) the temperature dependence of the dielectric constant in SiO 2 thin films down to 10 K. The fast electrical characterization feedback will be critical in developing robust materials and components for cryogenic computing devices.

36 MATERIALS SCIENCE↗

Advancing 1D thermo-hydraulic tools for large cryogenic facilities

The Cryogenic Division at Fermilab develops large-scale cryogenic systems for particle accelerators and superconducting magnet test facilities. To support design and diagnostics, a Python-based code was created to calculate pressure drops in components such as valves and pipes. This paper presents recent enhancements to the code, including new heat transfer functions that improve the accuracy of thermal and hydraulic predictions. The first application models pressure and temperature changes in Proton Improvement Plant PIP-II relief pipes, aiding pipe sizing and protecting relief valves. The second example analyses heat load evolution in a pipe carrying sub-atmospheric helium, helping interpret temperature sensor data and understand gas return behavior to cold compressors. These improvements significantly expand the tool's capabilities, offering a practical resource for designing and troubleshooting cryogenic systems under dynamic thermal and flow conditions.

Beckwith, R. [Fermilab]↗

Cryogenic Correlative Single-Particle Photoluminescence Spectroscopy and Electron Tomography for Investigation of Nanomaterials

Cryogenic single-particle photoluminescence (PL) spectroscopy has been used with great success to directly observe the heterogeneous photophysical states present in a population of luminescent particles. Cryogenic electron tomography provides complementary nanometer scale structural information to PL spectroscopy, but the two techniques have not been correlated due to technical challenges. Here, we present a method for correlating single-particle information from these two powerful microscopy modalities. We simultaneously observe PL brightness, emission spectrum, and in-plane excitation dipole orientation of CdSSe/ZnS quantum dots suspended in vitreous ice. Stable and fluctuating emitters were observed, as well as a surprising splitting of the PL spectrum into two bands with an average energy separation of 80 meV. In some cases, the onset of the splitting corresponded to changes in the in-plane excitation dipole orientation. These dynamics were assigned to structures of individual quantum dots and the excitation dipoles were visualized in the context of structural features.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cryogenic energy storage: Standalone design, rigorous optimization and techno-economic analysis

Energy storage allows flexible use and management of excess electricity and intermittently available renewable energy. Cryogenic energy storage (CES) is a promising storage alternative with a high technology readiness level and maturity, but the round-trip efficiency is often moderate and the Levelized Cost of Storage (LCOS) remains high. The complex flowsheets with intricate thermodynamics at cryogenic temperatures as well as the presence of multiple loops and refrigeration cycles pose considerable challenges for rigorous model-based design and optimization of CES systems. We present an optimization strategy that couples rigorous process simulation and Bayesian optimization with flowsheet decomposition and identification of hidden coupling constraints to optimally design standalone CES systems. Further refinement is done via a local search using the limited-memory Broyden–Fletcher–Goldfarb–Shanno algorithm. Here our results indicate that it is possible to achieve more than 52% round-trip efficiency and an LCOS of $153/MWh for a standalone 100 MW/400 MWh CES system limited to short-term storage with daily charging–discharging. However, a detailed techno-economic assessment reveals that the LCOS considering total capital investment may exceed $267/MWh when all direct and indirect costs of installation and operation are considered.

25 ENERGY STORAGE↗

Focused ion beam deposited carbon-platinum nanowires for cryogenic resistive thermometry

The study of thermal effects, both classical and quantum, at cryogenic temperatures requires the use of on-chip, local, high-sensitivity thermometry. Carbon-platinum composites fabricated using focused ion beam (FIB) assisted deposition form a granular structure which is shown in this study to be uniquely suited for this application. Carbon-platinum thermometers deposited using a 24 pA ion beam current have high sensitivities below 1 K, comparable to the best cryogenic thermometers. In addition, these thermometers can be accurately placed to within 10s of nanometers on the chip using a mask-free process. Furthermore, they also have a weak magnetic field dependence, 3% change in resistance with applied magnetic fields from 0 to 8 T. Finally, these thermometers are integrable into a variety of nanoscale devices due to the existing wide spread use of FIB.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Operation of helium sub-atmospheric multistage cryogenic centrifugal compressor trains: Part 2 – Transient modeling and pump-down path selection

Low-pressure conditions required for operation of helium cryogenic systems below the normal boiling point (i.e. 4.2 K) are established through a transient process, commonly referred to as ‘pump-down’. This process is defined as the transition from pressures above atmospheric conditions to the saturation pressure which corresponds to a specified operational temperature. The FRIB 2 K system consists of five cryogenic centrifugal compressors which are operated in series. Historically, the pump-down process path has been established through empirical methods and system operator experience. Investigation into the pump-down process at FRIB aimed to develop a pump-down methodology which relies on theoretical model predictions rather than empirically developed process paths. Ensuring stable operation during the pump-down process involved application of a centrifugal compressor performance prediction model, which is described in Part 1 of this paper. Compressor performance maps can be directly used to evaluate the stability of a selected pump-down path and anticipate the overall reliability of the selected path. In conjunction with the compressor performance maps, a system pressure model was developed to estimate the transient pressure response during the pump-down process. Lastly, an explicit equation was developed to establish a mass flow rate profile for the pump-down process. Implementation of the presented methodology (including the developed models) allows for the system operator to determine a continuous pump-down path which maintains compressor stability while conforming to overall system capabilities. Altogether, the methodology presented has resulted in simplification of transient pump-down operations and increased the reliability, stability and efficiency of the pump-down process.

Compressor train control↗

Numerical predictions of cryogenic hydrogen vertical jets

Here, a comparison of Computational Fluid Dynamics (CFD) predictions with measurements is presented for cryo-compressed hydrogen vertical jets. The stagnation conditions of the experiments are characteristic of unintended leaks from pipe systems that connect cryogenic hydrogen storage tanks and could be encountered at a fuel cell refueling station. Jets with pressure up to 5 bar and temperatures just above the saturation liquid temperature were examined. Comparisons are made to the centerline mass fraction and temperature decay rates, the radial profiles of mass fraction and the contours of volume fraction. Two notional nozzle approaches are tested to model the under-expanded jet that was formed in the tests with pressures above 2 bar. In both approaches the mass and momentum balance from the throat to the notional nozzle are solved, while the temperature at the notional nozzle was assumed equal to the nozzle temperature in the first approach and was calculated by an energy balance in the second approach. The two approaches gave identical results. Satisfactory agreement with the measurements was found in terms of centerline mass fraction and temperature. However, for test with 3 and 4 bar release the concentration was overpredicted. Furthermore, a wider radial spread was observed in the predictions possibly revealing higher degree of diffusion using the k-ε turbulence model. An integral model for cryogenic jets was also developed and provided good results. Finally, a test simulation was performed with an ambient temperature jet and compared to the cold jet showing that warm jets decay faster than cold jets.

08 HYDROGEN↗

Characteristic of cryogenic hydrogen flames from high-aspect ratio nozzles

Unintentional leaks at hydrogen fueling stations have the potential to form hydrogen jet flames, which pose a risk to people and infrastructure. The heat flux from these jet flames are often used to develop separation distances between hydrogen components and buildings, lot-lines, etc. The heat flux and visible flame length is well understood for releases from round nozzles, but real unintended leaks would be expected to be from higher aspect-ratio cracks. Here, we measured the visible flame length and heat-flux characteristics of cryogenic hydrogen flames from high-aspect ratio nozzles. Heat flux measurements from 5 radiometers were used to assess the single-point vs the multi-point methods for interpretation of heat flux sensor data, finding the axial distance of the sensor for a single-point heat flux measurement to be important. We compare the flame length and heat flux data to flames of both cryogenic and compressed hydrogen from round nozzles. The aspect ratio of the release does not affect the flame length or heat flux significantly, for a given mass flow under the range of conditions studied. The engineering correlations presented in this work enable the prediction of flame length and heat flux which can be used to assess risk at hydrogen fueling stations with liquid hydrogen and develop science-based separation distances for these stations.

08 HYDROGEN↗

Lattice response to ambient self-irradiation of δ-phase 239 Pu-Ga alloys exposed to cryogenic temperatures

Self-irradiation in plutonium is a continuous process that introduces radiation damage ranging from point defects to nanoscale radiation damage as well as decay daughter product impurities that require to be accommodated by the host material. These changes are affecting the structure and properties of the material by lattice swelling, mechanical strengthening, and other alterations. X-ray diffraction and dilatometry studies have shown that the room temperature self-irradiation of δ-phase Pu-Ga alloys (2 and 7 at%Ga) results in swelling of the lattice that saturates after 0.1–0.2 displacement per atom (dpa) of accumulated lattice damage. Here, for a better understanding of these self- irradiation processes, defect accumulation and damage evolution, this time-of-flight neutron diffraction study investigates the impact of ambient self-irradiation effects on the structural evolution of δ-phase 239 Pu-Ga alloys exposed to cryogenic temperatures (<120 K), associated with a varied history of storage time and thermal treatments. Two key behaviors were observed in the lattice evolution after exposure to cryogenic temperatures with respect to room-temperature accumulated self-irradiation damage. Samples with no self- irradiation damage accumulation under ambient conditions showed swelling of the lattice at the end of the measurement, while samples that accumulated significant self-irradiation damage under ambient conditions showed only a partial recovery of the lattice parameter value upon completion of the measurements (cooling followed by heating back to room temperature). Possible causes of the behavior are proposed, and their associated effects are discussed.

36 MATERIALS SCIENCE↗

Identification and demonstration of roGFP2 as an environmental sensor for cryogenic correlative light and electron microscopy

Cryogenic correlative light and electron microscopy (cryo-CLEM) seeks to leverage orthogonal information present in two powerful imaging modalities. While recent advances in cryogenic electron microscopy (cryo-EM) allow for the visualization and identification of structures within cells at the nanometer scale, information regarding the cellular environment, such as pH, membrane potential, ionic strength, etc., which influences the observed structures remains absent. Fluorescence microscopy can potentially be used to reveal this information when specific labels, known as fluorescent biosensors, are used, but there has been minimal use of such biosensors in cryo-CLEM to date. Here we demonstrate the applicability of one such biosensor, the fluorescent protein roGFP2, for cryo-CLEM experiments. At room temperature, the ratio of roGFP2 emission brightness when excited at 425 nm or 488 nm is known to report on the local redox potential. When samples containing roGFP2 are rapidly cooled to 77 K in a manner compatible with cryo-EM, the ratio of excitation peaks remains a faithful indicator of the redox potential at the time of freezing. Using purified protein in different oxidizing/reducing environments, we generate a calibration curve which can be used to analyze in situ measurements. As a proof-of-principle demonstration, we investigate the oxidation/reduction state within vitrified Caulobacter crescentus cells. The polar organizing protein Z (PopZ) localizes to the polar regions of C. crescentus where it is known to form a distinct microdomain. Finally, by expressing an inducible roGFP2-PopZ fusion we visualize individual microdomains in the context of their redox environment.