Model-Based Diagnostics for Propellant Loading Systems

The loading of spacecraft propellants is a complex, risky operation. Therefore, diagnostic solutions are necessary to quickly identify when a fault occurs, so that recovery actions can be taken or an abort procedure can be initiated. Model-based diagnosis solutions, established using an in-depth analysis and understanding of the underlying physical processes, offer the advanced capability to quickly detect and isolate faults, identify their severity, and predict their effects on system performance. We develop a physics-based model of a cryogenic propellant loading system, which describes the complex dynamics of liquid hydrogen filling from a storage tank to an external vehicle tank, as well as the influence of different faults on this process. The model takes into account the main physical processes such as highly nonequilibrium condensation and evaporation of the hydrogen vapor, pressurization, and also the dynamics of liquid hydrogen and vapor flows inside the system in the presence of helium gas. Since the model incorporates multiple faults in the system, it provides a suitable framework for model-based diagnostics and prognostics algorithms. Using this model, we analyze the effects of faults on the system, derive symbolic fault signatures for the purposes of fault isolation, and perform fault identification using a particle filter approach. We demonstrate the detection, isolation, and identification of a number of faults using simulation-based experiments.

Daigle, Matthew John↗

Validation of CFD Model Prediction of Flow Boiling Regime Transitions during LN2 Line Chilldown

Propellant storage and transfer during future long-duration missions will involve fuel depot operations in which a donor depot tank is used to fill a receiver spacecraft tank with a cryogenic propellant. Prior to the on-Orbit filling operation both the receiver tank and the transfer line must be cooled. The line chilldown process involves transition between boiling regimes in microgravity that will be quite different from their 1g ground-based counterparts. Since the cryogenic propellant itself will be used to perform the chilldown process, the time constants to cool the wall and the amount of fuel that will be used become important design considerations. In this light, the focus of the present work is to understand the flow boiling characteristics of a cryogenic fluid, namely, liquid nitrogen, during the chill-down of a transfer line using CFD modelling and simulations. The cryogenic chill-down process involves different flow boiling regimes: film boiling, transition boiling and nucleate boiling. The prediction of transition between these regimes in a CFD framework is new and challenging. The present work addresses this challenge by employing a volume-of-fluid (VOF) based methodology with Lee phase change model to predict the film boiling regime of the chill-down process in ANSYS Fluent®. The transition and nucleate boiling regimes are predicted by incorporating a sub-grid model developed by Craft Tech that accounts for bubble nucleation, growth, shedding frequency, and departure diameter. The sub-grid model is implemented into Fluent via a user-defined function for wall-fluid heat flux calculations. The sub-grid model is similar in formulation to the well-known Rensselaer Polytechnic Institute (RPI) boiling model. The model constants are tested for different operating conditions and designated values are reported. The CFD model is validated against published experimental data for liquid nitrogen chill-down of a heated stainless-steel pipe in 1g. Predicted results showing good agreement of wall temperature, rewetting temperature, and transition between film and nucleate boiling with the experimental measurements are presented and discussed.

Boiling regimes↗

Predictions of Line Chilldown Boiling Regime Transitions by a Coupled CFD-Sub-Grid Boiling Model Validated against 1G LN2 Experiments

Propellant storage and transfer during future long-duration missions will involve fuel depot operations in which a donor depot tank is used to fill a receiver spacecraft tank with a cryogenic propellant. Prior to the on-Orbit filling operation both the receiver tank and the transfer line must be cooled. The line chilldown process involves transition between boiling regimes in microgravity that will be quite different from their 1g ground-based counterparts. Since the cryogenic propellant itself will be used to perform the chilldown process, the time constants to cool the wall and the amount of fuel that will be used become important design considerations. In this light, the focus of the present work is to capture the flow boiling characteristics of a cryogenic fluid, namely, liquid nitrogen, during the chill-down of a transfer line using CFD modelling and simulations. The cryogenic chill-down process involves different flow boiling regimes: film boiling, transition boiling and nucleate boiling. The prediction of transition between these regimes in a CFD framework is new and challenging. The present work addresses this challenge by employing a volume-of-fluid (VOF) based methodology with Lee phase change model to predict the film boiling regime of the chill-down process in ANSYS Fluent®. The transition and nucleate boiling regimes are predicted by incorporating a sub-grid model that accounts for bubble nucleation, growth, shedding frequency, and departure diameter. The sub-grid model is implemented into Fluent via a user-defined function for wall-fluid heat flux calculations. The sub-grid model is similar in formulation to the well-known Rensselaer Polytechnic Institute (RPI) boiling model. The CFD model is validated against published experimental data for liquid nitrogen chill-down of a heated stainless-steel pipe in 1g. Predicted results shows good agreement of wall temperature, rewetting temperature, and transition between film and nucleate boiling with the experimental measurements for several different LN2 flowrates in the vertical orientation. The strengths and weaknesses of this modeling approach are presented and discussed.

Cryogenic Fluid Management↗

Shuttle operations, maintenance, and safety.

Review of a systematic search for practical solutions in the areas of space shuttle cryogenics, flight operations, ground operations, and safety. The insulation of the main-propulsion hydrogen tanks for both booster and orbiter to prevent water condensation is considered, as well as the insulation of the orbiter's orbital cryogen tanks for ground storage. Two approaches to the feeding of cryogens are outlined - namely, an approach depending on a periodic axial force to settle propellants and refill the basket, and a method of continuous feed through a capillary network adjacent to the walls throughout the tank, the latter method being independent of vehicle thrust. The development of reliable cryogen components is discussed, and the results of studies of launch-abort problems, shuttle approach and landing techniques, and the tolerance of ?deconditioned' crew and passengers to shuttle reentry g-loads are cited.

Beddingfield, S. T.↗

Effect of Residual Noncondensables on Pressurization and Pressure Control of a Zero-Boil-Off Tank in Microgravity

The Zero-Boil-Off Tank (ZBOT) Experiment is a small-scale experiment that uses a transparent ventless Dewar and a transparent simulant phase-change fluid to study sealed tank pressurization and pressure control with applications to on-surface and in-orbit storage of propellant cryogens. The experiment will be carried out under microgravity conditions aboard the International Space Station in the 2014 timeframe. This paper presents preliminary results from ZBOT's ground-based research that focuses on the effects of residual noncondensable gases in the ullage on both pressurization and pressure reduction trends in the sealed Dewar. Tank pressurization is accomplished through heating of the test cell wall in the wetted and un-wetted regions simultaneously or separately. Pressure control is established through mixing and destratification of the bulk liquid using a temperature controlled forced jet flow with different degrees of liquid jet subcooling. A Two-Dimensional axisymmetric two-phase CFD model for tank pressurization and pressure control is also presented. Numerical prediction of the model are compared to experimental 1g results to both validate the model and also indicate the effect of the noncondensable gas on evolution of pressure and temperature distributions in the ullage during pressurization and pressure control. Microgravity simulations case studies are also performed using the validated model to underscore and delineate the profound effect of the noncondensables on condensation rates and interfacial temperature distributions with serious implications for tank pressure control in reduced gravity.

Marangoni and Natural Convection↗

Acoustic and Thermal Testing of an Integrated Multilayer Insulation and Broad Area Cooling Shield System

A Multilayer Insulation (MLI) and Broad Area Cooling (BAC) shield thermal control system shows promise for long-duration storage of cryogenic propellant. The NASA Cryogenic Propellant Storage and Transfer (CPST) project is investigating the thermal and structural performance of this tank-applied integrated system. The MLI/BAC Shield Acoustic and Thermal Test was performed to evaluate the MLI/BAC shield's structural performance by subjecting it to worst-case launch acoustic loads. Identical thermal tests using Liquid Nitrogen (LN2) were performed before and after the acoustic test. The data from these tests was compared to determine if any degradation occurred in the thermal performance of the system as a result of exposure to the acoustic loads. The thermal test series consisted of two primary components: a passive boil-off test to evaluate the MLI performance and an active cooling test to evaluate the integrated MLI/BAC shield system with chilled vapor circulating through the BAC shield tubes. The acoustic test used loads closely matching the worst-case envelope of all launch vehicles currently under consideration for CPST. Acoustic test results yielded reasonable responses for the given load. The thermal test matrix was completed prior to the acoustic test and successfully repeated after the acoustic test. Data was compared and yielded near identical results, indicating that the MLI/BAC shield configuration tested in this series is an option for structurally implementing this thermal control system concept.

Wood, J. J.↗

Acoustic and Thermal Testing of an Integrated Multilayer Insulation and Broad Area Cooling Shield System

A Multilayer Insulation (MLI) and Broad Area Cooling (BAC) shield thermal control system shows promise for long-duration storage of cryogenic propellant. The NASA Cryogenic Propellant Storage and Transfer (CPST) project is investigating the thermal and structural performance of this tank-applied integrated system. The MLI/BAC Shield Acoustic and Thermal Test was performed to evaluate the MLI/BAC shield's structural performance by subjecting it to worst-case launch acoustic loads. Identical thermal tests using Liquid Nitrogen (LN2) were performed before and after the acoustic test. The data from these tests was compared to determine if any degradation occurred in the thermal performance of the system as a result of exposure to the acoustic loads. The thermal test series consisted of two primary components: a passive boil-off test to evaluate the MLI performance and an active cooling test to evaluate the integrated MLI/BAC shield system with chilled vapor circulating through the BAC shield tubes. The acoustic test used loads closely matching the worst-case envelope of all launch vehicles currently under consideration for CPST. Acoustic test results yielded reasonable responses for the given load. The thermal test matrix was completed prior to the acoustic test and successfully repeated after the acoustic test. Data was compared and yielded near identical results, indicating that the MLI/BAC shield configuration tested in this series is an option for structurally implementing this thermal control system concept.

Wood, Jessica J.↗

Vented Chill / No-Vent Fill of Cryogenic Propellant Tanks

Architectures for extended duration missions often include an on-orbit replenishment of the space vehicle's cryogenic liquid propellants. Such a replenishment could be accomplished via a tank-to-tank transfer from a dedicated tanker or a more permanent propellant depot storage tank. Minimizing the propellant loss associated with transfer line and receiver propellant tank thermal conditioning is essential for mass savings. A new methodology for conducting tank-to-tank transfer while minimizing such losses has been demonstrated. Charge-Hold-Vent is the traditional methodology for conducting a tank-to-tank propellant transfer. A small amount of cryogenic liquid is introduced to chill the transfer line and propellant tank. As the propellant absorbs heat and undergoes a phase change, the tank internal pressure increases. The tank is then vented to relieve pressure prior to another charge of cryogenic liquid being introduced. This cycle is repeated until the transfer lines and tank are sufficiently chilled and the replenishment of the propellant tank is complete. This method suffers inefficiencies due to multiple chill and vent cycles within the transfer lines and associated feed system components. Additionally, this system requires precise measuring of cryogenic fluid delivery for each transfer, multiple valve cycling events, and other complexities associated with cycled operations. To minimize propellant loss and greatly simplify on-orbit operations, an alternate methodology has been designed and demonstrated. The Vented Chill / No Vent Fill method is a simpler, constant flow approach in which the propellant tank and transfer lines are only chilled once. The receiver tank is continuously vented as cryogenic liquid chills the transfer lines, tank mass and ullage space. Once chilled sufficiently, the receiver tank valve is closed and the tank is completely filled. Interestingly, the vent valve can be closed prior to receiver tank components reaching liquid saturation temperature. An incomplete fill results if insufficient energy is removed from the tank's thermal mass and ullage space. The key to successfully conducting the no vent fill is to assure that sufficient energy is removed from the system prior to closing the receiver tank vent valve. This paper will provide a description of the transfer methodology and test article, and will provide a discussion of test results.

Rhys, Noah O.↗

Cryogenic foam insulation: Abstracted publications

A group of documents were chosen and abstracted which contain information on the properties of foam materials and on the use of foams as thermal insulation at cryogenic temperatures. The properties include thermal properties, mechanical properties, and compatibility properties with oxygen and other cryogenic fluids. Uses of foams include applications as thermal insulation for spacecraft propellant tanks, and for liquefied natural gas storage tanks and pipelines.

Williamson, F. R.↗

Simulation of Propellant Loading System Senior Design Implement in Computer Algorithm

Propellant loading from the Storage Tank to the External Tank is one of the very important and time consuming pre-launch ground operations for the launch vehicle. The propellant loading system is a complex integrated system involving many physical components such as the storage tank filled with cryogenic fluid at a very low temperature, the long pipe line connecting the storage tank with the external tank, the external tank along with the flare stack, and vent systems for releasing the excess fuel. Some of the very important parameters useful for design purpose are the prediction of pre-chill time, loading time, amount of fuel lost, the maximum pressure rise etc. The physics involved for mathematical modeling is quite complex due to the fact the process is unsteady, there is phase change as some of the fuel changes from liquid to gas state, then conjugate heat transfer in the pipe walls as well as between solid-to-fluid region. The simulation is very tedious and time consuming too. So overall, this is a complex system and the objective of the work is student's involvement and work in the parametric study and optimization of numerical modeling towards the design of such system. The students have to first become familiar and understand the physical process, the related mathematics and the numerical algorithm. The work involves exploring (i) improved algorithm to make the transient simulation computationally effective (reduced CPU time) and (ii) Parametric study to evaluate design parameters by changing the operational conditions

Bandyopadhyay, Alak↗

Spray Bar Zero-Gravity Vent System for On-Orbit Liquid Hydrogen Storage

During zero-gravity orbital cryogenic propulsion operations, a thermodynamic vent system (TVS) concept is expected to maintain tank pressure control without propellant resettling. In this case, a longitudinal spray bar mixer system, coupled with a Joule-Thompson (J-T) valve and heat exchanger, was evaluated in a series of TVS tests using the 18 cu m multipurpose hydrogen test bed. Tests performed at fill levels of 90, 50, and 25 percent, coupled with heat tank leaks of about 20 and 50 W, successfully demonstrated tank pressure control within a 7-kPa band. Based on limited testing, the presence of helium constrained the energy exchange between the gaseous and liquid hydrogen (LH2) during the mixing cycles. A transient analytical model, formulated to characterize TVS performance, was used to correlate the test data. During self-pressurization cycles following tank lockup, the model predicted faster pressure rise rates than were measured; however, once the system entered the cyclic self-pressurization/mixing/venting operational mode, the modeled and measured data were quite similar. During a special test at the 25-percent fill level, the J-T valve was allowed to remain open and successfully reduced the bulk LH2 saturation pressure from 133 to 70 kPa in 188 min.

Hastings, L. J.↗

Validation of Cryogenic Propellant Tank Self-Pressurization

NASA's near-future long-term space missions necessitate advancements in cryogenic fluid management (CFM), which includes safe and reliable long-term propellant storage. Consequently, NASA STMD (Space Technology Mission Directorate) has established the CFM Portfolio Project to improve CFM technologies for upcoming missions. As a part of CFM Modeling Portfolio, NASA Marshall Space Flight Center's (MSFC) Fluid Dynamics branch within the Propulsion Systems Department is tasked with assessing and improving computational tools used to support flight projects such as Human Lander System and Commercial Lunar Payload Services. One of the challenging modeling problems is that of self-pressurization of propellant tank due to heat leakage over long time periods. Reduced order and nodal tools find it extremely difficult to accurately predict self-pressurization under transient conditions or where complex flow patterns or thermal gradients exist, and application of 3-D CFD (computational fluid dynamics) simulations is necessary to characterize these problems. Until recently, CFD simulations for these long-term processes (order of hours or days) have been too impractical to conduct due to prohibitive wall time and computational resource requirements. The requisite CFD tool need to be efficient, computationally scalable, modular with ability to incorporate various physics models, and robust enough to not accumulate conservation errors over several hours of simulated time. NASA MSFC's Loci-Stream CFD tool along with the VOF module is a great candidate to fit this mold. In this paper, we validate Loci-Stream for predicting self-pressurization of a flight scale propellant tank so it can serve as a reliable design and analysis tool for NASA's CFM application needs. Liquid hydrogen tank pressurization tests carried out at the K-site testing facility provide a reliable data set for this purpose. These tests were simulated using Loci-Stream solver with VOF module as well as a hybrid approach which uses a lumped model for the ullage gas domain and CFD simulation of the liquid propellant. Both are shown to have very good predictive capabilities over multiple K-site experiments.

cryogenic fluid management↗

Active Costorage of Cryogenic Propellants for Exploration

Long-term storage of cryogenic propellants is a critical requirement for NASA's effort to return to the moon. Liquid hydrogen and liquid oxygen provide the highest specific impulse of any practical chemical propulsion system, and thus provides the greatest payload mass per unit of launch mass. Future manned missions will require vehicles with the flexibility to remain in orbit for months, necessitating long-term storage of these cryogenic liquids. For decades cryogenic scientific satellites have used cryogens to cool instruments. In many cases, the lifetime of the primary cryogen tank has been extended by intercepting much of the heat incident on the tank at an intermediate-temperature shield cooled either by a second cryogen tank or a mechanical cryocooler. For an LH2/LO2 propellant system, a combination of these ideas can be used, in which the shield around the LO2 tank is attached to, and at the same temperature as, the LO2 tank, but is actively cooled so as to remove all heat impinging on the tank and shield. This configuration eliminates liquid oxygen boil-off and cuts the liquid hydrogen boil-off to a small fraction of the unshielded rate. This paper studies the concept of active costorage as a means of long-term cryogenic propellant storage. The paper describes the design impact of an active costorage system for the Crew Exploration Vehicle (CEV). This paper also compares the spacecraft level impact of the active costorage concept with a passive storage option in relation to two different scales of spacecraft that will be used for the lunar exploration effort, the CEV and the Earth Departure Stage (EDS). Spacecraft level studies are performed to investigate the impact of scaling of the costorage technologies for the different components of the Lunar Architecture and for different mission durations.

Canavan, Edgar R.↗

The COLD-SAT program

The Cryogenic On-Orbit Liquid Depot Storage, Acquisition and Transfer (COLD-SAT) satellite is an experimental spacecraft launched from an expendable launch vehicle which is designed to investigate the systems and technologies required for efficient and reliable management of cryogenic fluid in the reduced-gravity space environment. Future applications such as Space Station, Space Transportation Vehicle (STV), external tank (ET), aft cargo carrier (ACC) propellant scavenging, storage depots, and lunar and interplanetary missions, among others, have provided the impetus to pursue this technology in a timely manner to support the design efforts. A refined conceptual approach has been developed and an overview of the COLD-SAT program is described which includes the following: (1) a definition of the technology needs and the accompanying experimental six-month baseline mission; (2) a description of the experiment subsystem, major features, and rationale for satisfaction of primary and secondary experiment requirements using LH2 as the test fluid; and (3) a presentation of the conceptual design of the COLD-SAT spacecraft subsystems which support the on-orbit experiment with emphasis on those areas which posed the greatest technical challenge.

Bailey, William J.↗

Validation of Cryogenic Propellant Tank Self-Pressurization

NASA’s near-future long-term space missions necessitate advancements in cryogenic fluid management (CFM), which includes safe and reliable long-term propellant storage. Consequently, NASA STMD (Space Technology Mission Directorate) has established the CFM Portfolio Project to improve CFM technologies for upcoming missions. As a part of CFM Modeling Portfolio, NASA Marshall Space Flight Center’s (MSFC) Fluid Dynamics branch within the Propulsion Systems Department is tasked with assessing and improving computational tools used to support flight projects such as Human Lander System and Commercial Lunar Payload Services. One of the challenging modeling problems is that of self-pressurization of propellant tank due to heat leakage over long time periods. Reduced order and nodal tools find it extremely difficult to accurately predict self-pressurization under transient conditions or where complex flow patterns or thermal gradients exist, and application of 3-D CFD (computational fluid dynamics) simulations is necessary to characterize these problems. Until recently, CFD simulations for these long-term processes (order of hours or days) have been too impractical to conduct due to prohibitive wall time and computational resource requirements. The requisite CFD tool need to be efficient, computationally scalable, modular with ability to incorporate various physics models, and robust enough to not accumulate conservation errors over several hours of simulated time. NASA MSFC’s Loci-Stream CFD tool along with the VOF module is a great candidate to fit this mold. In this paper, we validate Loci-Stream for predicting self-pressurization of a flight scale propellant tank so it can serve as a reliable design and analysis tool for NASA’s CFM application needs. Liquid hydrogen tank pressurization tests carried out at the K-site testing facility provide a reliable data set for this purpose. These tests were simulated using Loci-Stream solver with VOF module as well as a hybrid approach which uses a lumped model for the ullage gas domain and CFD simulation of the liquid propellant. Both are shown to have very good predictive capabilities over multiple K-site experiments.

Hong Q. Yang↗

Propulsion and fluid management - Station keeping will eat energy on a new scale

An attempt is made to identify technologies that could be brought to a state of minimal development risk in the near term, yet offer the potential for evolutionary growth consistent with future space station propulsion requirements. Prospective auxiliary propulsion propellants will be usable by other systems, thereby offering resupply benefits and a benign rather than corrosive or toxic handling environment. NASA programs are currently underway to develop the storage and supply methods for cryogenic liquids in orbit. The recovery of unused propellants from the Space Shuttle Orbiter and External Tank are being evaluated in order to define Shuttle modifications and performance penalties. Fluid management subsystem requirements and characteristics cannot, however, be fully defined until a firm mission scenario has been established and other space station subsystems are more clearly defined.

Petrash, D. A.↗

Space Transportation System (STS) propellant scavenging system study. Volume 1: Technical report

The objectives are to define the most efficient and cost effective methods for scavenging cryogenic and storable propellants and then define the requirements for these scavenging systems. For cryogenic propellants, scavenging is the transfer of propellants from the Shuttle orbiter external tank (ET) and/or main propulsion subsystems (MPS) propellant lines into storage tanks located in the orbiter payload bay for delivery to the user station by a space based transfer stage or the Space Transportation System (STS) by direct insertion. For storable propellants, scavenging is the direct transfer from the orbital maneuvering subsystem (OMS) and/or tankage in the payload bay to users in LEO as well as users in the vicinity of the Space Station.