Search NASASearch

SEARCH · Search NASA

Results for “Cycle Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Fundamental Investigation of Silicon Anode in Lithium-Ion Cells

Silicon is a promising and attractive anode material to replace graphite for high capacity lithium ion cells since its theoretical capacity is ~10 times of graphite and it is an abundant element on Earth. However, there are challenges associated with using silicon as Li-ion anode due to the significant first cycle irreversible capacity loss and subsequent rapid capacity fade during cycling. Understanding solid electrolyte interphase (SEI) formation along with the lithium ion insertion/de-insertion kinetics in silicon anodes will provide greater insight into overcoming these issues, thereby lead to better cycle performance. In this paper, cyclic voltammetry and electrochemical impedance spectroscopy are used to build a fundamental understanding of silicon anodes. The results show that it is difficult to form the SEI film on the surface of a Si anode during the first cycle; the lithium ion insertion and de-insertion kinetics for Si are sluggish, and the cell internal resistance changes with the state of lithiation after electrochemical cycling. These results are compared with those for extensively studied graphite anodes. The understanding gained from this study will help to design better Si anodes, and the combination of cyclic voltammetry with impedance spectroscopy provides a useful tool to evaluate the effectiveness of the design modifications on the Si anode performance.

Wu, James J.

Rational Design of High-Performing Electrodes in Energy Storage Devices

Our approach in this project is to control conductivities of different ions by modulating the pore sizes in MOFs as sulfur hosts in cathodes. To validate our hypothesis that controlling the pore size of MOFs can effectively prevent LiPSs shuttling while allowing sufficient Li ion transport, which will ensure electrochemical cycling performance, we performed molecular dynamics (MD) simulations using a series of UiO MOFs with different linker sizes including LiPSs and electrolyte components (1M LiTFSI in DME/DOL 1:1 volume) in pores. Specifically, UiO-66, UiO-67, and UiO-68 are Zr-based MOFs with a linker length of 5.67 Å, 10.07 Å, and 14.35 Å, respectively, leading to different pore diameters of 8.4 Å, 12.8 Å, and 17.8 Å. We calculated the mean-squared displacements of Li and LiPS from MD simulations at 300 K for 50 ns or over to assess their mobility in MOFs.

25 ENERGY STORAGE

Long cycle life rechargeable lithium batteries

Cycle life and safety of delta-LiAl/TiS2 cells were evaluated using laboratory and AA-size cells. Analysis of the alloys (which contained 60, 70, 80, or 85 wt-pct. lithium and are designated 60 LiAl etc.) showed them to contain a mixture of elemental Li and Al4Li9. Cycling efficiencies correlated with the amount of free lithium in the anode. Using an electrolyte with the composition 48 v/o THF:48 v/o 2-MeTHF:4 v/o 2-MeF/LiAsF6(1.5M), a 70 LiAl/TiS2 laboratory cell yielded a cycling efficiency of 96.4 pct. when cycled at a 100 pct. discharge depth which compares well with Li anode cycling efficiencies of 96 to 97.5 pct. obtained previously in this electrolyte. The highest cycling efficiency of any delta-LiAl/TiS2 laboratory cell was 96.7 pct. when the 60 LiAl alloy was used with the 35 v/o PC:35 v/o EC:30 v/o triglyme/LiAsF6(1.0M) electrolyte. The 70 LiAl alloy was selected for further testing in AA cells since it was malleable for the fabrication of spirally wound electrodes, and its overall cycling performance was sufficiently good. AA-size 70 LiAl/TiS2 cells appear to have capacity/rate properties similar to those for identical Li/TiS2 cells. The use of the delta-LiAl alloy anodes does not appear to offer any safety advantage when cycled cells are shorted or heated.

Pasquariello, D. M.

Fluorinated Rocksalt‐Polyanion Cathode for Lithium‐Ion Batteries

Integrated rocksalt‐polyanion cathodes (DRXPS) are promising candidates for next‐generation lithium‐ion battery cathode materials that combine high energy density, stable cycling performance, and reduced reliance on Co and Ni. In this work, we investigated Li 3 Mn 1.6 P 0.4 O 5.4 F 0.6 , a new DRXPS cathode with fluoride incorporation. A pure spinel phase was formed and a discharge capacity retention of 84% was achieved after 200 cycles between 1.5 and 4.8 V versus Li/Li + . In comparison, the similarly synthesized Li 3 Mn 1.6 Nb 0.4 O 5.4 F 0.6 , in which all P 5+ was substituted by Nb 5+ while maintaining the same stoichiometry for all other elements, crystallized in a disordered rocksalt structure, and exhibited inferior capacity retention and rate capability than the P 5+ counterpart. Our findings expand the compositional space of DRXPS to include F − , justify the viability of integrating polyanion groups in rocksalt‐type cathodes, and highlight the superiority of P 5+ as a cation charge compensator compared to the commonly used Nb 5+ . This work thereby advances the design of robust, high‐performance cathode materials for sustainable batteries.

36 MATERIALS SCIENCE

Operation of a New Half-Bridge Gate Driver for Enhancement - Mode GaN FETs, Type LM5113, Over a Wide Temperature Range

A new commercial-off-the-shelf (COTS) gate driver designed to drive both the high-side and the low-side enhancement-mode GaN FETs, National Semiconductor's type LM5113, was evaluated for operation at temperatures beyond its recommended specified limits of -40 C to +125 C. The effects of limited thermal cycling under the extended test temperature, which ranged from -194 C to +150 C, on the operation of this chip as well as restart capability at the extreme cryogenic and hot temperatures were also investigated. The driver circuit was able to maintain good operation throughout the entire test regime between -194 C and +150 C without undergoing any major changes in its outputs signals and characteristics. The limited thermal cycling performed on the device also had no effect on its performance, and the driver chip was able to successfully restart at each of the extreme temperatures of -194 C and +150 C. The plastic packaging of this device was also not affected by either the short extreme temperature exposure or the limited thermal cycling. These preliminary results indicate that this new commercial-off-the-shelf (COTS) halfbridge eGaN FET driver integrated circuit has the potential for use in space exploration missions under extreme temperature environments. Further testing is planned under long-term cycling to assess the reliability of these parts and to determine their suitability for extended use in the harsh environments of space.

Patterson, Richard

Dry-processed electrodes enabled by polytetrafluoroethylene fibrillation for high-performance lithium-ion batteries

The dry processing technique of polytetrafluoroethylene (PTFE) fibrillation offers significant advancements in cost reduction, environmental impact, and electrochemical performance. Dry processing alone allows for ∼ 20–60% cost reduction and increases of up to 40 mg cm⁻2 of areal loading – it typically comes at a reduction of rate capability. By leveraging the network structure of fibers, this method enhances rate capability and cycling performance, providing a compelling alternative to the conventional and currently predominant wet processing. The review delves into PTFE fibrillation mechanisms and examines critical influencing factors including material properties and processing parameters. It also discusses challenges associated with the electrodes fabricated by PTFE fibrillation, including structural instability due to insufficient PTFE fibrillization, compromised electrical conductivity from an insufficient conductive network, inhomogeneous dispersion resulting from the absence of solvents, restricted ionic transport due to increased electrode thickness, inadequate adhesion to current collector because of low surface energy of PTFE, electrochemical degradation due to low lowest unoccupied molecular orbital (LUMO) level of PTFE, particle damage during processing and environmental concerns related PTFE being a perfluoroalkyl and polyfluoroalkyl substances (PFAS). Recent research innovations aimed at mitigating these issues, their application in beyond-lithium batteries, and future research directions are thoroughly discussed.

Park, Hyunji

Numerical Simulations of a Quiet SuperSonic Technology (QueSST) Aircraft Preliminary Design

Reynolds Averaged Navier-Stokes (RANS) simulations were performed on the Lockheed Martin Quiet SuperSonic Technology (QueSST) aircraft preliminary design to assess inlet performance. The FUN3D flow solver and its adjoint-based grid refinement capability was used for the simulations in hopes of determining internal "best practices" for predicting inlet performance on top-aft-mounted inlets. Several parameters were explored including tetrahedral vs. pentahedral cells in/around the boundary-layer regions, an engine axis-aligned linear pressure sensor vs. a pressure box objective as the grid adaptation metric, and the number of grid adaptation cycles performed. Additional simulations were performed on manually refined grids for comparison with the adjoint-based adapted grids

Adjoint-based Grid Adaptation

Numerical Simulations of a Quiet SuperSonic Technology (QueSST) Aircraft Preliminary Design

Reynolds Averaged Navier-Stokes (RANS) simulations were performed on the Lockheed Martin Quiet SuperSonic Technology (QueSST) aircraft preliminary design to assess inlet performance. The FUN3D flow solver and its adjoint-based grid refinement capability was used for the simulations in hopes of determining internal "best practices" for predicting inlet performance on top-aft-mounted inlets. Several parameters were explored including tetrahedral vs. pentahedral cells in/around the boundary-layer regions, an engine axis-aligned linear pressure sensor vs. a pressure box objective as the grid adaptation metric, and the number of grid adaptation cycles performed. Additional simulations were performed on manually refined grids for comparison with the adjoint-based adapted grids

Adjoint-based Grid Adaptation

The Effect of Electrolyte Additives upon the Lithium Kinetics of Li-Ion Cells Containing MCMB and LiNi(x)Co(1-x)O2 Electrodes and Exposed to High Temperatures

With the intent of improving the performance of lithium-ion cells at high temperatures, we have investigated the use of a number of electrolyte additives in experimental MCMB- Li(x)Ni(y)Co(1-y)O2 cells, which were exposed to temperatures as high as 80 C. In the present work, we have evaluated the use of a number of additives, namely vinylene carbonate (VC), dimethyl acetamide (DMAc), and mono-fluoroethylene carbonate (FEC), in an electrolyte solution anticipated to perform well at warm temperature (i.e., 1.0M LiPF6 in EC+EMC (50:50 v/v %). In addition, we have explored the use of novel electrolyte additives, namely lithium oxalate and lithium tetraborate. In addition to determining the capacity and power losses at various temperatures sustained as a result of high temperature cycling (cycling performed at 60 and 80 C), the three-electrode MCMB-Li(x)Ni(y)Co(1-y)O2 cells (lithium reference) enabled us to study the impact of high temperature storage upon the solid electrolyte interphase (SEI) film characteristics on carbon anodes (MCMB-based materials), metal oxide cathodes, and the subsequent impact upon electrode kinetics.

High Temperture Resilience

Discharge Rate‐Driven Li 2 O 2 Growth Exhibits Unconventional Morphology Trends in Solid‐State Li‐O 2 Batteries

Solid-state lithium oxygen batteries (LOBs) are known for their enhanced safety, higher electrochemical stability, and improved energy density compared to liquid-state LOBs. However, the investigation of solid-state LOBs is limited with little understanding of their discharge and charge processes. In this work, a polymer-based solid-state LOB is used to investigate the effect of discharge rate on lithium peroxide (Li 2 O 2 ) formation, the oxygen evolution reaction (OER), and cycle performance. Notably, we observe a counterintuitive trend: Li 2 O 2 particle size increases with increasing discharge current density, in contrast to liquid systems. This behavior arises from inherent space charge layers that restrict Li⁺ transport under high current, and spatially heterogeneous active sites at the solid electrolyte–cathode interface, directly evidenced by small angle X-ray scattering (SAXS), which govern nucleation accessibility and promote site-selective Li 2 O 2 growth. Furthermore, higher current densities improve ORR and OER efficiency but accelerate anode degradation, while lower currents promote side reactions. These opposing effects result in a trade-off that defines an optimal discharge rate (0.1 mA cm -2 ) for maximizing cycle life. This study provides a new mechanistic perspective on discharge-driven processes in solid-state LOBs and offers practical guidelines for performance optimization in future high-energy battery systems.

Discharge current density

Modeling Single-Crystal Battery Materials: From Fundamental Understanding to Performance Evaluation

The performance of rechargeable batteries is fundamentally influenced by the physicochemical properties and microstructural features of their key material components. Recent experimental advancements have highlighted the potential of single-crystal (SC) morphologies to address inherent limitations of polycrystalline (PC) electrodes and solid-state electrolytes, offering tunable charge transport kinetics and improved cell cycling performance. Here, this review examines how state-of-the-art computational modeling, from atomistic and mesoscale to continuum-level approaches, including machine learning methodologies, has been utilized to investigate the critical factors governing the electrochemical behavior of SC battery materials. We explore how predictive modeling can elucidate the processing–structure–property–performance relationships of SC cathodes, anodes, and solid-state electrolytes, with a focus on unique SC characteristics such as crystallographic anisotropy, size effects, and facet-dependent properties. Additionally, we identify limitations in commonly used modeling techniques and discuss strategies to address these challenges. By integrating high-fidelity simulations with experimental insights, this review aims to outline a clear path for the rational design and optimization of SC battery components, paving the way for accelerated advancements in energy storage technologies.

Materials science

Analysis of Degradation and Electrochemical Behavior of Lithium–Oxygen Batteries under Lean Electrolyte Conditions

Lithium-oxygen batteries have garnered much attention in the past decades due to their high energy density and active material abundancy. Decreasing the electrolyte volume is critical to achieving a high energy density for practical applications. Recent works have demonstrated a serious performance limitation at lower electrolyte fillings. Here, in this work, we study specifically the difference between flooded and lean electrolyte lithium-oxygen batteries by systematically tracing the source of performance degradation. We find that the key contributor to the decrease in performance under lean electrolyte conditions stems from the lithium metal anode rather than the cathode. Solid electrolyte interphase (SEI) compositionally appears to be the same from X-ray photoelectron spectroscopy but the coverage is less uniform, and impedance is much higher under lean electrolyte conditions. Such an effect likely produced the observed poorer cycle performance at 10 μL cm -2 (similar to 28% cathode's pore volume filled) vs 100 μL cm -2 (278% of cathode's pore volume) at a capacity of 1.0 mAh cm -2 (0.1 mAh cm -2 ) using an electrolyte composition of 1 M LiTFSI in TEGDME.

Córdoba, Daniel [Argonne National Laboratory (ANL)

Composition-Nanoarchitecture-Performance Analysis of High Energy Density Electrodeposited Silicon for Lithium-Ion Battery Anodes

Electrodeposition of silicon (Si) was previously demonstrated as a promising method for fabricating 3D-structured lithium-ion battery anodes. However, the relationship between the electrochemical performance and chemical composition of the relatively impure electrodeposited silicon is not well understood. Here, we report the electrodeposition of a Si-dominant active material (EDEP-Si) onto 3D-structured nickel (Ni) scaffolds and systematically compare the electrochemical properties, elemental composition, atomistic Si coordination, and molecular structure of EDEP-Si with high-purity amorphous Si grown via static chemical vapor deposition. Despite the considerable amount of carbon (9–11 at %) and oxygen (42–44 at %) present in EDEP-Si, the cycling stability and high reversible specific capacity are remarkably similar to those of CVD-Si on a silicon basis (~2400 mA h/g-Si after 100 cycles). The primary difference is that EDEP-Si exhibits reduced cycling efficiency over the first 10–20 cycles. Reactions between carbon and, more importantly, oxygen in EDEP-Si with lithium are likely responsible for the reduced early cycle performance and lower capacity of the total deposit. Finally, our observations suggest ultrapure Si is not necessary for high electrochemical access to reversible charge storage, although limiting the presence of incorporated impurity species would improve energy density and first cycle efficiency.

25 ENERGY STORAGE

Deconvoluting the impact of current collector structure and electrolyte selection on Coulombic efficiency of lithium metal anodes

Lithium metal batteries are regarded as a promising avenue for significantly boosting the gravimetric energy density of batteries, particularly for electric vehicles. However, the instability of the lithium metal anode continues to hinder performance. While 3D structured current collectors for lithium metal anodes have been frequently proposed as a solution, few studies explore the impact of these structures when combined with various electrolytes and the inclusion of a lithium reservoir within the structure. This study pairs four commercially available copper current collectors with four different electrolytes to assess how these factors influence cycling performance with a 4 mAh/cm2 lithium reservoir. Coulombic efficiency (CE) measurements revealed no statistically significant difference in CE across different current collectors within the same electrolyte. However, significant variations were noted when the current collector remained intact, and the electrolyte was changed. Although polarization, electrochemical impedance, and lithium morphology varied between structures and electrolytes, no consistent patterns emerged to suggest superior performance by any specific current collector structure. Therefore, the choice of structure appears inconsequential when a lithium reservoir is present, and efforts should focus on selecting and designing the electrolyte.

White, Julia

Cold startup and low temperature performance of the Brayton cycle electrical subsystem

Cold performance tests and startup tests were conducted on the Brayton-cycle inverter, motor-driven pump, dc supply, speed control with parasitic load resistor and the Brayton control system. These tests were performed with the components in a vacuum and mounted on coldplates. A temperature range of ?25 to -50 C was used for the tests. No failures occurred, and component performance gave no indication that there would be any problem with the safe operation of the Brayton power generating system.

Vrancik, J. E.

Tailoring P2/P3‐Intergrowth in Manganese‐Based Layered Transition Metal Oxide Positive Electrodes via Sodium Content for Na‐Ion Batteries

High-manganese content sodium-ion positive electrodes have received heightened interest as an alternative to contemporary Li-ion chemistries due to their high abundance, low toxicity, and even geographical distribution. However, these materials typically suffer from poor capacity, unstable cycling performance, and sluggish Na + kinetics. Herein, we explore a manganese-based layered transition metal oxide (Na x N 0.25 Mn 0.75 O 2 ) and show by X-ray diffraction (XRD) and high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM) that careful variation of the sodium content can instigate the formation of a biphasic intergrowth. This intergrown P2/P3 material offered a higher capacity than its monophasic P2 counterpart due to the P3 structure having greater low-voltage Mn 3+/4+ redox. Further, the intergrowth material offers greatly enhanced kinetics and cycling stability when compared to single-phase P3 material, due to the stabilizing nature of the P2 structure, elucidated by galvanostatic intermittent titration technique (GITT) and operando synchrotron X-ray diffraction. These results highlight the beneficial effect that the intergrowth structure has on the electrochemical performance of high-manganese content positive electrode for future sodium-ion batteries.

25 ENERGY STORAGE

Tracing U.S. fuel life-cycle greenhouse gas emissions in a multi-sector dynamics model using LC-GCAM

Model-based analysis of fuel pathways is essential for informing energy and environmental policy. Two major model types are typically used: multi-sector dynamics models, which capture the broader energy-economy, such as GCAM (Global Change Analysis Model), and life cycle assessment models, such as GREET (Greenhouse Gases, Regulated Emissions, and Energy Use in Transportation). Each has distinct strengths and limitations, and recent studies increasingly adopt hybrid approaches to harness the advantages of both. However, such integration is often time-consuming and complicated by inconsistencies in system boundaries and technology definitions. We present LC-GCAM, a new tool that enables estimation of life-cycle greenhouse gas emissions and primary energy use for any fuel pathway represented in GCAM. We apply LC-GCAM to 300 scenarios designed to explore key uncertainties affecting the life-cycle performance of future fuel options in the U.S. freight sector. To evaluate LC-GCAM, we compare its results with those from GREET for nine fuel types in a 2030 reference scenario. When input assumptions are modestly aligned, LC-GCAM and GREET estimates typically agree within 10% (absolute sum-based mean absolute percentage error). LC-GCAM offers a flexible and efficient approach to generating life-cycle metrics within an integrated modeling framework, supporting robust policy analysis across a wide range of interacting energy system uncertainties.

Wolfram, Paul

Validity of a heart rate monitor during work in the laboratory and on the Space Shuttle

Accurate heart rate measurement during work is required for many industrial hygiene and ergonomics situations. The purpose of this investigation was to determine the validity of heart rate measurements obtained by a simple, lightweight, commercially available wrist-worn heart rate monitor (HRM) during work (cycle exercise) sessions conducted in the laboratory and also during the particularly challenging work environment of space flight. Three different comparisons were made. The first compared HRM data to simultaneous electrocardiogram (ECG) recordings of varying heart rates that were generated by an ECG simulator. The second compared HRM data to ECG recordings collected during work sessions of 14 subjects in the laboratory. Finally, ECG downlink and HRM data were compared in four astronauts who performed cycle exercise during space flight. The data were analyzed using regression techniques. The results were that the HRM recorded virtually identical heart rates compared with ECG recordings for the data set generated by an ECG simulator. The regression equation for the relationship between ECG versus HRM heart rate data during work in the laboratory was: ECG HR = 0.99 x (HRM) + 0.82 (r2 = 0.99). Finally, the agreement between ECG downlink data and HRM data during space flight was also very high, with the regression equation being: Downlink ECG HR = 1.05 x (HRM) -5.71 (r2 = 0.99). The results of this study indicate that the HRM provides accurate data and may be used to reliably obtain valid data regarding heart rate responses during work.

STS Shuttle Project