Search NASA⌕ Search

SEARCH · Search NASA

Results for “DATA ACQUISITION AND PROCESSING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

WA-Omic_LA.1.0 - Quantitative Lipidomics, Metabolomics, and Sequencing (16S/ITS) Publication Data DOI Package

Corresponding Data Publication: "Rapid remodeling of the soil lipidome in response to a drying-rewetting event." This study reveals specific changes in lipids and metabolites that are indicative of stress adaptation, substrate use, and cellular recovery during soil drying and subsequent rewetting. Drought induced nutrient limitation was reflected in the lipidome and polar metabalome, both of which rapidly shifted (within hours) upon rewet. Reduced nutrient access in dry soil caused the replacement of glycerophospholipids with phosphorus-free lipids and impeded resource-expensive osmolyte accumulation. Elevated levels of ceramides and lipids with long chain polyunsaturated fatty acids, in dry soil suggests that lipids play an important role in fungal drought tolerance. Increasing abundance of bacterial glycerophospholipids and triacylglycerols with fatty acids typical of bacteria and polar metabolites suggest metabolic recovery in representative bacteria once the environmental conditions are conducive for growth. These results underscore the importance of the soil lipidome as a robust indicator of microbial community responses, especially at the short time scales of cell-environment reactions. Data package contents reported here are the first version and contain pre- and post-processed data acquisition and subsequent downstream analysis files using various data source instrument method techniques and Mass Spectroscopy (MS) EMSL capabilities. This publication data package DOI is a comprehensive high-throughput multi-omics data lifecycle collection containing processed data method metadata. Support files include additional data download “Read Me” file containing data descriptor information and data source application ontologies (see data dictionary). Reported data download contents are structured for compliance with project data sharing guidelines, community standards initiatives, and sponsor stakeholder policies supporting FAIR data principles. For increased data availability and interoperability, GC-MS/LC-MS mass spectrometry datasets (Thermo .raw ) were deposited at the MassIVE database repository under the related data accession MSV000086931 and can be accessed by using the API. Statistical data processing software, analysis tools, and data workflows are listed below corresponding to the host repository long-term location.

Amplicon sequencing 16S ITS LC-MS/MS lipidomics mu↗

WA-Omic_LA.1.0 - Quantitative Lipidomics, Metabolomics, and Sequencing (16S/ITS) Publication Data DOI Package

Corresponding Data Publication: "Rapid remodeling of the soil lipidome in response to a drying-rewetting event." This study reveals specific changes in lipids and metabolites that are indicative of stress adaptation, substrate use, and cellular recovery during soil drying and subsequent rewetting. Drought induced nutrient limitation was reflected in the lipidome and polar metabalome, both of which rapidly shifted (within hours) upon rewet. Reduced nutrient access in dry soil caused the replacement of glycerophospholipids with phosphorus-free lipids and impeded resource-expensive osmolyte accumulation. Elevated levels of ceramides and lipids with long chain polyunsaturated fatty acids, in dry soil suggests that lipids play an important role in fungal drought tolerance. Increasing abundance of bacterial glycerophospholipids and triacylglycerols with fatty acids typical of bacteria and polar metabolites suggest metabolic recovery in representative bacteria once the environmental conditions are conducive for growth. These results underscore the importance of the soil lipidome as a robust indicator of microbial community responses, especially at the short time scales of cell-environment reactions. Data package contents reported here are the first version and contain pre- and post-processed data acquisition and subsequent downstream analysis files using various data source instrument method techniques and Mass Spectroscopy (MS) EMSL capabilities. This publication data package DOI is a comprehensive high-throughput multi-omics data lifecycle collection containing processed data method metadata. Support files include additional data download “Read Me” file containing data descriptor information and data source application ontologies (see data dictionary). Reported data download contents are structured for compliance with project data sharing guidelines, community standards initiatives, and sponsor stakeholder policies supporting FAIR data principles. For increased data availability and interoperability, GC-MS/LC-MS mass spectrometry datasets (Thermo .raw ) were deposited at the MassIVE database repository under the related data accession MSV000086931 and can be accessed by using the API. Statistical data processing software, analysis tools, and data workflows are listed below corresponding to the host repository long-term location.

Amplicon sequencing 16S ITS LC-MS/MS lipidomics mu↗

WA-Omic_LA.1.0 - Quantitative Lipidomics, Metabolomics, and Sequencing (16S/ITS) Publication Data DOI Package

Corresponding Data Publication: "Rapid remodeling of the soil lipidome in response to a drying-rewetting event." This study reveals specific changes in lipids and metabolites that are indicative of stress adaptation, substrate use, and cellular recovery during soil drying and subsequent rewetting. Drought induced nutrient limitation was reflected in the lipidome and polar metabalome, both of which rapidly shifted (within hours) upon rewet. Reduced nutrient access in dry soil caused the replacement of glycerophospholipids with phosphorus-free lipids and impeded resource-expensive osmolyte accumulation. Elevated levels of ceramides and lipids with long chain polyunsaturated fatty acids, in dry soil suggests that lipids play an important role in fungal drought tolerance. Increasing abundance of bacterial glycerophospholipids and triacylglycerols with fatty acids typical of bacteria and polar metabolites suggest metabolic recovery in representative bacteria once the environmental conditions are conducive for growth. These results underscore the importance of the soil lipidome as a robust indicator of microbial community responses, especially at the short time scales of cell-environment reactions. Data package contents reported here are the first version and contain pre- and post-processed data acquisition and subsequent downstream analysis files using various data source instrument method techniques and Mass Spectroscopy (MS) EMSL capabilities. This publication data package DOI is a comprehensive high-throughput multi-omics data lifecycle collection containing processed data method metadata. Support files include additional data download “Read Me” file containing data descriptor information and data source application ontologies (see data dictionary). Reported data download contents are structured for compliance with project data sharing guidelines, community standards initiatives, and sponsor stakeholder policies supporting FAIR data principles. For increased data availability and interoperability, GC-MS/LC-MS mass spectrometry datasets (Thermo .raw ) were deposited at the MassIVE database repository under the related data accession MSV000086931 and can be accessed by using the API. Statistical data processing software, analysis tools, and data workflows are listed below corresponding to the host repository long-term location.

Amplicon sequencing 16S ITS LC-MS/MS lipidomics mu↗

Laser velocimeter data acquisition system for the Langley 14- by 22-foot subsonic tunnel. Software reference guide version 3.3

The Laser Velocimeter Data Acquisition System (LVDAS) in the Langley 14- by 22-Foot Tunnel is controlled by a comprehensive software package. The software package was designed to control the data acquisition process during wind tunnel tests which employ a laser velocimeter measurement system. This report provides detailed explanations on how to configure and operate the LVDAS system to acquire laser velocimeter and static wind tunnel data.

Jumper, Judith K.↗

FACE-IT. A Science Gateway for Food Security Research

Progress in sustainability science is hindered by challenges in creating and managing complex data acquisition, processing, simulation, post-processing, and intercomparison pipelines. To address these challenges, we developed the Framework to Advance Climate, Economic, and Impact Investigations with Information Technology (FACE-IT) for crop and climate impact assessments. This integrated data processing and simulation framework enables data ingest from geospatial archives; data regridding, aggregation, and other processing prior to simulation; large-scale climate impact simulations with agricultural and other models, leveraging high-performance and cloud computing; and post-processing to produce aggregated yields and ensemble variables needed for statistics, for model intercomparison, and to connect biophysical models to global and regional economic models. FACE-IT leverages the capabilities of the Globus Galaxies platform to enable the capture of workflows and outputs in well-defined, reusable, and comparable forms. We describe FACE-IT and applications within the Agricultural Model Intercomparison and Improvement Project and the Center for Robust Decision-making on Climate and Energy Policy.

97 MATHEMATICS AND COMPUTING↗

The Atmospheric Data Acquisition And Interpolation Process For Center-TRACON Automation System

The Center-TRACON Automation System (CTAS), an advanced new air traffic automation program, requires knowledge of spatial and temporal atmospheric conditions such as the wind speed and direction, the temperature and the pressure in order to accurately predict aircraft trajectories. Real-time atmospheric data is available in a grid format so that CTAS must interpolate between the grid points to estimate the atmospheric parameter values. The atmospheric data grid is generally not in the same coordinate system as that used by CTAS so that coordinate conversions are required. Both the interpolation and coordinate conversion processes can introduce errors into the atmospheric data and reduce interpolation accuracy. More accurate algorithms may be computationally expensive or may require a prohibitively large amount of data storage capacity so that trade-offs must be made between accuracy and the available computational and data storage resources. The atmospheric data acquisition and processing employed by CTAS will be outlined in this report. The effects of atmospheric data processing on CTAS trajectory prediction will also be analyzed, and several examples of the trajectory prediction process will be given.

Jardin, M. R.↗

Recommended Practice for Patch Management of Control Systems

A key component in protecting a nation’s critical infrastructure and key resources is the security of control systems. The term industrial control system refers to supervisory control and data acquisition, process control, distributed control, and any other systems that control, monitor, and manage the nation’s critical infrastructure. Critical Infrastructure and Key Resources (CIKR) consists of electric power generators, transmission systems, transportation systems, dam and water systems, communication systems, chemical and petroleum systems, and other critical systems that cannot tolerate sudden interruptions in service. Simply stated, a control system gathers information and then performs a function based on its established parameters and the information it receives. The patch management of industrial control systems software used in CIKR is inconsistent at best and nonexistent at worst. Patches are important to resolve security vulnerabilities and functional issues. This report recommends patch management practices for consideration and deployment by industrial control systems owners.

42 ENGINEERING↗

A computer controlled signal preprocessor for laser fringe anemometer applications

The operation of most commercially available laser fringe anemometer (LFA) counter-processors assumes that adjustments are made to the signal processing independent of the computer used for reducing the data acquired. Not only does the researcher desire a record of these parameters attached to the data acquired, but changes in flow conditions generally require that these settings be changed to improve data quality. Because of this limitation, on-line modification of the data acquisition parameters can be difficult and time consuming. A computer-controlled signal preprocessor has been developed which makes possible this optimization of the photomultiplier signal as a normal part of the data acquisition process. It allows computer control of the filter selection, signal gain, and photo-multiplier voltage. The raw signal from the photomultiplier tube is input to the preprocessor which, under the control of a digital computer, filters the signal and amplifies it to an acceptable level. The counter-processor used at Lewis Research Center generates the particle interarrival times, as well as the time-of-flight of the particle through the probe volume. The signal preprocessor allows computer control of the acquisition of these data.Through the preprocessor, the computer also can control the hand shaking signals for the interface between itself and the counter-processor. Finally, the signal preprocessor splits the pedestal from the signal before filtering, and monitors the photo-multiplier dc current, sends a signal proportional to this current to the computer through an analog to digital converter, and provides an alarm if the current exceeds a predefined maximum. Complete drawings and explanations are provided in the text as well as a sample interface program for use with the data acquisition software.

Oberle, Lawrence G.↗

Fission neutron spectra measurements at LANSCE - status and plans

A program to measure fission neutron spectra from neutron-induced fission of actinides is underway at the Los Alamos Neutron Science Center (LANSCE) in a collaboration among the CEA laboratory at Bruyeres-le-Chatel, Lawrence Livermore National Laboratory and Los Alamos National Laboratory. The spallation source of fast neutrons at LANSCE is used to provide incident neutron energies from less than 1 MeV to 100 MeV or higher. The fission events take place in a gas-ionization fission chamber, and the time of flight from the neutron source to that chamber gives the energy of the incident neutron. Outgoing neutrons are detected by an array of organic liquid scintillator neutron detectors, and their energies are deduced from the time of flight from the fission chamber to the neutron detector. Measurements have been made of the fission neutrons from fission of {sup 235}U, {sup 238}U, {sup 237}Np and {sup 239}Pu. The range of outgoing energies measured so far is from 1 MeV to approximately 8 MeV. These partial spectra and average fission neutron energies are compared with evaluated data and with models of fission neutron emission. Results to date will be presented and a discussion of uncertainties will be given in this presentation. Future plans are to make significant improvements in the fission chambers, neutron detectors, signal processing, data acquisition and the experimental environment to provide high fidelity data including mea urements of fission neutrons below 1 MeV and improvements in the data above 8 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bayesian analysis for estimating statistical parameter distributions of elasto-viscoplastic material models

High temperature design methods rely on constitutive models for inelastic deformation and failure typically calibrated against the mean of experimental data without considering the associated scatter. Variability may arise from the experimental data acquisition process, from heat-to-heat material property variations, or both and need to be accurately captured to predict parameter bounds leading to efficient component design. Applying the Bayesian Markov Chain Monte Carlo (MCMC) method to produce statistical models capturing the underlying uncertainty in the experimental data is an area of ongoing research interest. This work varies aspects of the Bayesian MCMC method and explores their effect on the posterior parameter distributions for a uniaxial elasto-viscoplastic damage model using synthetically generated reference data. From our analysis with the uniaxial inelastic model we determine that an informed prior distribution including different types of test conditions results in more accurate posterior parameter distributions. The parameter posterior distributions, however, do not improve when increasing the number of similar experimental data. Additionally, changing the amount of scatter in the data affects the quality of the posterior distributions, especially for the less sensitive model parameters. Moreover, we perform a sensitivity study of the model parameters against the likelihood function prior to the Bayesian analysis. The results of the sensitivity analysis help to determine the reliability of the posterior distributions and reduce the dimensionality of the problem by fixing the insensitive parameters. The comprehensive study described in this work demonstrates how to efficiently apply the Bayesian MCMC methodology to capture parameter uncertainties in high temperature inelastic material models. Quantifying these uncertainties in inelastic models will improve high temperature engineering design practices and lead to safer, more effective component designs.

42 ENGINEERING↗

NASA IVHM Technology Experiment for X-vehicles (NITEX)

The purpose of the NASA IVHM Technology Experiment for X-vehicles (NITEX) is to advance the development of selected IVHM technologies in a flight environment and to demonstrate the potential for reusable launch vehicle ground processing savings. The technologies to be developed and demonstrated include system-level and detailed diagnostics for real-time fault detection and isolation, prognostics for fault prediction, automated maintenance planning based on diagnostic and prognostic results, and a microelectronics hardware platform. Complete flight The Evolution of Flexible Insulation as IVHM consists of advanced sensors, distributed data acquisition, data processing that includes model-based diagnostics, prognostics and vehicle autonomy for control or suggested action, and advanced data storage. Complete ground IVHM consists of evolved control room architectures, advanced applications including automated maintenance planning and automated ground support equipment. This experiment will advance the development of a subset of complete IVHM.

Sandra, Hayden↗

Rydberg-electron decoherence in experimentally obtained recurrence spectra

Using scaled-energy spectroscopy techniques (recurrence spectroscopy) we investigate the influence of collisionally induced decoherence on semiclassical orbits in the Stark-Rydberg system. This experimental investigation represents the first application of recurrence spectroscopy to an atomic system perturbed by collisions with external gas partners. We present high-resolution recurrence spectra of potassium, revealing core-scattered combination orbits, and with minor modifications to the data acquisition process, recurrence spectra were also obtained with the system perturbed by 10 torr of krypton gas. A simple decoherence model is applied to semiclassical theory to explain the loss of recurrence strength at high actions. In several cases we also observe the loss of coherent interference between orbits. The loss of coherent destructive interference causes an increase in the recurrence strength of several core-scattered combination orbits.

74 ATOMIC AND MOLECULAR PHYSICS↗

Toward Rapid Unattended X-ray Tomography of Large Planar Samples at 50-nm Resolution

X-ray tomography at sub-50 nm resolution of small areas ({approx}15 {mu}mx15 {mu}m) are routinely performed with both laboratory and synchrotron sources. Optics and detectors for laboratory systems have been optimized to approach the theoretical efficiency limit. Limited by the availability of relatively low-brightness laboratory X-ray sources, exposure times for 3-D data sets at 50 nm resolution are still many hours up to a full day. However, for bright synchrotron sources, the use of these optimized imaging systems results in extremely short exposure times, approaching live-camera speeds at the Advanced Photon Source at Argonne National Laboratory near Chicago in the US These speeds make it possible to acquire a full tomographic dataset at 50 nm resolution in less than a minute of true X-ray exposure time. However, limits in the control and positioning system lead to large overhead that results in typical exposure times of {approx}15 min currently.We present our work on the reduction and elimination of system overhead and toward complete automation of the data acquisition process. The enhancements underway are primarily to boost the scanning rate, sample positioning speed, and illumination homogeneity to performance levels necessary for unattended tomography of large areas (many mm{sup 2} in size). We present first results on this ongoing project.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Imaging properties and its improvements of scanning/imaging x-ray microscope

A scanning / imaging X-ray microscope (SIXM) system has been developed at SPring-8. The SIXM consists of a scanning X-ray microscope with a one-dimensional (1D) X-ray focusing device and an imaging (full-field) X-ray microscope with a 1D X-ray objective. The motivation of the SIXM system is to realize a quantitative and highly-sensitive multimodal 3D X-ray tomography by taking advantages of both the scanning X-ray microscope using multi-pixel detector and the imaging X-ray microscope. Data acquisition process of a 2D image is completely different between in the horizontal direction and in the vertical direction; a 1D signal is obtained with the linear-scanning while the other dimensional signal is obtained with the imaging optics. Such condition have caused a serious problem on the imaging properties that the imaging quality in the vertical direction has been much worse than that in the horizontal direction. In this paper, two approaches to solve this problem will be presented. One is introducing a Fourier transform method for phase retrieval from one phase derivative image, and the other to develop and employ a 1D diffuser to produce an asymmetrical coherent illumination.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modal characterization of the ASCIE segmented optics testbed: New algorithms and experimental results

New frequency response measurement procedures, on-line modal tuning techniques, and off-line modal identification algorithms are developed and applied to the modal identification of the Advanced Structures/Controls Integrated Experiment (ASCIE), a generic segmented optics telescope test-bed representative of future complex space structures. The frequency response measurement procedure uses all the actuators simultaneously to excite the structure and all the sensors to measure the structural response so that all the transfer functions are measured simultaneously. Structural responses to sinusoidal excitations are measured and analyzed to calculate spectral responses. The spectral responses in turn are analyzed as the spectral data become available and, which is new, the results are used to maintain high quality measurements. Data acquisition, processing, and checking procedures are fully automated. As the acquisition of the frequency response progresses, an on-line algorithm keeps track of the actuator force distribution that maximizes the structural response to automatically tune to a structural mode when approaching a resonant frequency. This tuning is insensitive to delays, ill-conditioning, and nonproportional damping. Experimental results show that is useful for modal surveys even in high modal density regions. For thorough modeling, a constructive procedure is proposed to identify the dynamics of a complex system from its frequency response with the minimization of a least-squares cost function as a desirable objective. This procedure relies on off-line modal separation algorithms to extract modal information and on least-squares parameter subset optimization to combine the modal results and globally fit the modal parameters to the measured data. The modal separation algorithms resolved modal density of 5 modes/Hz in the ASCIE experiment. They promise to be useful in many challenging applications.

Carrier, Alain C.↗

Miniature Focusing Time-of-Flight Mass Spectrometer

An improved miniature time-of-flight mass spectrometer has been developed in a continuing effort to minimize the sizes, weights, power demands, and costs of mass spectrometers for such diverse applications as measurement of concentrations of pollutants in the atmosphere, detecting poisonous gases in mines, and analyzing exhaust gases of automobiles. Advantageous characteristics of this mass spectrometer include the following: It is simple and rugged. Relative to prior mass spectrometers, it is inexpensive to build. There is no need for precise alignment of its components. Its mass range is practically unlimited Relative to prior mass spectrometers, it offers high sensitivity (ability to measure relative concentrations as small as parts per billion). Its resolution is one dalton (one atomic mass unit). An entire mass spectrum is recorded in a single pulse. (In a conventional mass spectrometer, a spectrum is recorded mass by mass.) The data-acquisition process takes only seconds. It is a lightweight, low-power, portable instrument. Although time-of-flight mass spectrometers (TOF-MSs) have been miniaturized previously, their performances have not been completely satisfactory. An inherent adverse effect of miniaturization of a TOF-MS is a loss of resolution caused by reduction of the length of its flight tube. In the present improved TOF-MS, the adverse effect of shortening the flight tube is counteracted by (1) using charged-particle optics to constrain ion trajectories to the flight-tube axis while (2) reducing ion velocities to increase ion flight times. In the present improved TOF-MS, a stream of gas is generated by use of a hypodermic needle. The stream of gas is crossed by an energy-selected, pulsed beam of electrons (see Figure 1). The ions generated by impingement of the electrons on the gas atoms are then focused by three cylindrical electrostatic lenses, which constitute a segmented flight tube. After traveling along the flight tube, the ions enter a charged-particle detector. The output of the detector is fed to a counting circuit to obtain data on the counting rate as a function of time. Inasmuch as time of flight is directly proportional to the ion mass, a plot of the counting rate versus time of flight is equivalent to a mass spectrum (see Figure 2).

Kanik, Isik↗