Search NASA⌕ Search

SEARCH · Search NASA

Results for “DC power flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

105 records · Page 6

Isolated Single-stage Three-phase AC/DC Converter using Bidirectional Switches

The advent of the SiC Bidirectional FET (BiDFET), a monolithic 1.2 kV bidirectional switch, has rendered the single-stage three-phase AC/DC converter topology a promising approach for implementing AC/DC converters. This topology, which integrates a full-bridge converter with a single-phase to three-phase matrix converter via a high-frequency transformer, is particularly suitable for applications requiring galvanic isolation, buck-boost functionality, and bidirectional power flow. The single-stage design eliminates the need for bulky and unreliable electrolytic capacitors, and utilizes a single magnetic component for power transfer. In the matrix converter, bidirectional switches, which were traditionally implemented using combinations of multiple semiconductor devices such as MOSFETs, IGBTs, and diodes, can now be realized using the single-chip solution, BiDFET. This advancement leads to a lower switch count, compact converter implementation, with lower inductance commutation cells, thereby enhancing the overall efficiency and compactness of the system. The paper presents a unified model of the converter, considering all control parameters, including the duty cycles and phase shift of transformer voltages. Detailed expressions for power transfer, transformer currents, and currents at AC and DC ports are provided. Additionally, the paper outlines the conditions necessary for soft-switching of all switches and the commutation schemes required for the practical implementation of the matrix converter modulation scheme. A hardware prototype of a 10 kW, 480 VRMS, LL/ 800 V AC/DC system has been developed, and experimental results are presented to demonstrate its performance.

BiDFET↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production by conducting a statistical analysis of historical wind data over a five-year period (2020-2025) from a single 1.5MW turbine manufactured by General Electric (GE) located at NLR’s Flatirons Campus, to generate an experimental test profile that was deployed on a 1.25-MW proton exchange membrane type MC250 electrolyzer system manufactured by Nel Hydrogen . [1] While the electrolyzer balance-of-plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. The historical wind data provided several metrics, however, the analysis particularly focused on the measured power output by the wind turbine. The power output time series of data for each day was categorized by total energy generation and standard deviation, and the day that represented the highest combination of these two metrics was chosen – December 25th, 2022. This process was then repeated for a moving four-hour window within this day to identify the most statistically variable period. Finally, this four-hour period was scaled by 65% to match the 1.25 MW electrolyzer. The electrolysis system controls hydrogen production by varying DC current applied to the stack, from a maximum of 3000 A to a minimum safe operation of 300 A, or 10%. Because the current – voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical wind profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1 Hz frequency. For more details on the statistical analysis process, see the presentation labeled “ Public Reference Data for Megawatt-Scale Hydrogen Electrolysis” provided with each data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}_{scaling factor}-{electrolyzer ramp rate in amperes/second} For instance, “wind-GE1.5MW_0.65-400.zip” represents the hour-long experiment using historical data from the wind-GE1.5MW turbine, scaled to 65%, with the electrolyzer power supply set to a maximum ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and wind power input. A PDF file detailing the historical wind data statistical analysis used to generate the wind profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_historical_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis [1] nelhydrogen.com/product/mc-series-electrolyser .

08 HYDROGEN↗

A Sequential Quadratic Programming Algorithm for Nonsmooth Problems with Upper- \({\boldsymbol{\mathcal{C}^2}}\) Objective

An optimization algorithm for nonsmooth nonconvex constrained optimization problems with upper- \({\boldsymbol{\mathcal{C}^2}}\) objective functions is proposed and analyzed. Upper- \({\boldsymbol{\mathcal{C}^2}}\) is a weakly concave property that exists in difference of convex (DC) functions and arises naturally in many applications, particularly certain classes of solutions to parametric optimization problems e.g., recourse of stochastic programming and projection onto closed sets. The algorithm can be viewed as an extension of sequential quadratic programming (SQP) to nonsmooth problems with upper- \({\boldsymbol{\mathcal{C}^2}}\) objectives or a simplified bundle method. It is globally convergent with bounded algorithm parameters that are updated with a trust-region criterion. The algorithm handles general smooth constraints through linearization and uses a line search to ensure progress. The potential inconsistencies from the linearization of the constraints are addressed through a penalty method. In conclusion, the capabilities of the algorithm are demonstrated by solving both simple upper- \({\boldsymbol{\mathcal{C}^2}}\) problems and a real-world optimal power flow problem used in current power grid industry practices.

97 MATHEMATICS AND COMPUTING↗

Conversion of CO 2 from power plant into CaCO 3 nanoparticles

Carbon dioxide (CO 2 ), a main composition of flue gas, represents a significant and largely untapped carbon resource. Herein, mediated by glycine (Gly), we captured and converted CO 2 into CaCO 3 nanoparticles using real flue gas from a power plant, demonstrating for the first time the feasibility of using amino acid to convert CO 2 from power plant flue gasses. The method did not require extraneous energy and CaCO 3 nanoparticles with a size of ∼25 nm were obtained. Moreover, the potential toxicity of CO 2 -converted nanoparticles was investigated. It appeared that both the initial CO 2 loading and the carbamate percentage significantly influence the shape and size of the CaCO 3 particles. Our method was also proven effective for flue gas with varying CO 2 concentrations (4 %, 12 %, and 20 %). By tuning flue gas bubbling time and flow rate to achieve consistent CO 2 loading and carbamate levels, we produced CaCO 3 nanoparticles with similar shapes and sizes across all CO 2 concentrations studied. In addition, our data indicated that although real flue gas contains small amounts of gases like oxygen and CO, they insignificantly influence the shape and size of our nanoparticles but did impact the phase component of CaCO 3 . In conclusion, the toxicity experiments found that CaCO 3 nanoparticles produced from both real flue gas and simulated flue gas exhibited concentration- and time-dependent effects on cell viability.

36 MATERIALS SCIENCE↗

Standardized nomenclature for photovoltaic connectors

Photovoltaic (PV) systems rely on discrete connectors for the efficient and safe flow of power from module to module and from strings to combiner boxes and inverters. Despite their functional importance, no common nomenclature for PV connectors currently exists, resulting in confusion and miscommunication. Misunderstood terms like "MC4 compatible", "cross-mating", "intermating", "female", and "male" can lead to installation and maintenance errors and compromise system reliability. We believe a standardized terminology will reduce confusion, help support installation best practices, aid in maintenance and repair, inform next-generation designs, and provide a technical basis for improved codes and standards. To that end, we are proposing a standardized glossary for 4 mm PV connectors (the most common type of connector used in PV applications) based on, and validated by, a Sandia National Laboratories' investigation that included the following sources: 1) a comprehensive review of official documents from 20 connector manufacturers, including schematics, datasheets, installation manuals, and catalogs, as well as relevant patents; 2) two rounds of surveys distributed to stakeholders, including connector manufacturers, engineers, asset owners, test labs, and researchers; and 3) visual examination of 25 different models of 4 mm single-pole DC PV connectors to document variations in design and functionality. This work provides a foundation for establishing a clear and consistent terminology for PV connectors that will in turn enable progress toward greater reliability and collaboration across the industry.

14 SOLAR ENERGY↗

Findings from Large Bench-Scale Testing of Denitration Electrolyzers for the EDCGe Project

This report highlights the key findings and outcomes relevant to the processability of waste supernatant at Hanford using a denitration electrolyzer. The Electrosynthesis Company issued a Phase 1 report to the Savannah River National Laboratory (SRNL), summarizing the evaluation of large bench-scale denitration electrolyzers to support the electrochemical denitration and caustic generation (EDCGe) project. The Electrosynthesis Company’s report (attached as Appendix A) provides insights into the initial steps required to implement an electrolyzer system at Hanford. Phase 1 experiments focused on validating the denitration electrolyzer’s performance, operating parameters, and reaction products. The robustness of the electrochemical denitration process was demonstrated by two electrolyzer flow cell systems (a 100 cm 2 ElectroCell MP and a 150 cm 2 NESI NS01 cell), both of which achieved significant nitrate and nitrite removal (>50%) with a current efficiency of ~95% for both systems. Higher current densities (500 mA cm –2 ) improved nitrate and nitrite removal rates compared to lower current densities (333 mA cm –2 ), while maintaining a current efficiency of ~94%. The NS01 cell achieved a nitrate species removal rate of ~0.41 mol h –1 at 5 kA m –2 (equiv. to 500 mA cm –2 ). The primary reaction product was ammonia (NH 3 ), constituting 78.3–91.6% of the products (excluding OH – formation). NH 3 was predominantly retained in the catholyte liquid phase rather than being off-gassed. Additionally, the NS01 cell reported an NH 3 generation rate of ~0.36 mol h –1 at 5 kA m –2 . Other gas formation included ~7% N 2 , ~7% H 2 , and trace amounts of N 2 O. The estimated power requirement (extrapolated from the 0.015 m 2 cell data) for a full-scale denitration electrolyzer is approximated to be ~1.6 MW (DC-only) to treat 50% of nitrate and nitrite in a waste stream and generates ~2.1 kmol h –1 of NH 3 with an initial concentration of 4 M NO 3 – /NO 2 – at 300 gal h –1 . Simulated waste containing aluminate, carbonate, oxalate, and halogens exhibited no adverse effects on denitration performance. A preliminary experiment comparing alkaline anolyte (5 M NaOH) with a nickel based anode to acidic media (2 M H 2 SO 4 ) with a DSA-O 2 anode showed a lower operating voltage and generated less H 2 than the acid media. Maintaining a stable 5 M OH – concentration in the anolyte through periodic additions of caustic did not significantly impact denitration performance. This operational mode will be required for long-term experiments. All the experiments demonstrated that electrochemical denitration is a promising approach for treating nitrate and nitrite in simulated waste streams, achieving significant conversion and robustness across varying experimental conditions and electrochemical cell configurations. Lastly, the ability to generate a nearly pure NH 3 stream may prove advantageous for processing at other locations within the Hanford site.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improvements to Passive Heat Removal Systems in SAS4A/SASSYS-1

Safe operation of a sodium cooled fast reactor (SFR) can be significantly aided by heat removal systems that do not rely on active power, but function using passive means. Passive heat removal from such reactors can employ systems that extract heat directly from sodium coolant by utilizing heat exchangers submerged in the coolant and natural circulation of a metal fluid sodium (or sodium potassium eutectic) to heat exchangers (generally air cooled) externally located. These types of systems are generally called Direct Reactor Auxiliary Cooling Systems (DRACS). Another type of passive heat removal system particularly suitable for pool-type SFRs relies on indirect extraction of heat by utilizing air flow in an annular region surrounding the reactor guard vessel which discharges the heat via the chimney effects to the atmosphere. These systems are generally called Reactor Vessel Auxiliary Cooling Systems (RVACS).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Simulink Model of a New Energy EVG-005 5kW Hydropower Turbine

Simulink model for a New Energy 5kW hydropower turbine. ADCP data ("ds_streamwise_7_13.nc") and DC voltage, DC current, and rotor rotation observed from the New Energy EVG-005 Current Energy Converter (CEC) ("electrical_7_13_10ohms.nc") were collected at the Tanana River Test Site (TRTS) near Nenana Alaska. - Data was collected on July 13th, 2023 with a constant 10 ohms resistance applied with a DC load bank. - Simulink model is meant to resemble the electrical setup at the TRTS. - Model is initialized by running the "NewEnergy_2023_10hz.m" Matlab script. Then the Simulink model ("New_Energy_Model_PMSM.slx") can be run. - Results are processed with the "NewEnergy_2023_processing.m" Matlab code. The Matlab results are also saved in the "New_Energy_7_13_model_validation_results.mat" Matlab file. This can be directly loaded into the Matlab Workspace using the "Load()" command. - The timetable variables "electrical_model_downsampled" is the model results and the "electrical_limited" is the experimental data from the TRTS.

16 TIDAL AND WAVE POWER↗

Collaborative Research Proposal: Time Resolved Optical Emissions Spectroscopy and Laser Induced Fluorescence Spectroscopy of Nanosecond Pulsed Discharges in a Gas-Liquid Water Film Reactor

Electrical discharge plasma formed in contact with liquid water is of interest for a wide range of applications in chemical, biomedical, agricultural, electrical, and materials science and engineering. Such plasma reactors are of very timely importance since they also have significant disinfection capability by inactivating bacteria, viruses and other pathogens. Many types of plasma sources including those driven by AC, DC, RF, microwave, and pulsed electrical power supplies coupled to a wide range of different electrode configurations and reactor designs have been developed and explored which contact the plasma with liquid water. Recent roadmaps have recommended that further work is needed to develop our understanding of the fundamental chemical and physical process which occur at the interface of non-thermal plasma with liquid water solutions in order to advance this large diversity of applications which ultimately depend upon efficient production of key reactive chemical species. There is a wide range of interacting factors that affect the chemical reactions that occur in the plasma, in the liquid phase, and at the interface. These factors ultimately govern the key reactive chemical species formed and used in the various applications and they include a) the reactor design and input parameters, b) the discharge and transport processes, c) the plasma properties, and d) the resulting chemical reactions. For pulsed discharges, the power supply design and output parameters control the applied voltage, frequency, rise time, and width (duration) of the applied pulses. The reactor design involves specification of the gas-liquid contacting methods, electrode gap distance, reactor volume and shape, and gas and liquid flow rates achievable. The gas and liquid compositions as well as the liquid properties such as pH and conductivity are also of key importance in determination of the resulting chemical reactions. In addition, the important plasma properties include plasma gas temperature, electron density, electron energy (distribution), and size of the plasma channels which are all affected by the discharge and transport properties. Many studies have focused on specific aspects of these various processes. Of particular important and relevance to the proposed work is the utilization of nanosecond pulses to generate plasma in gas-liquid systems, liquid bubbles, underwater, and in gases. Recent advances in nanosecond pulses provide significant advantages in utilization with liquid water. For example, fast rise time and short pulses are less sensitive to water conductivity, such short pulses may provide advantages in fast temporal quenching of the plasma, and fundamental analysis of pulse properties, including pulse shape and width, may be facilitated by investigation of single filamentary fast pulses. Many studies have also dealt with the role of the gas composition on formation of reactive oxygen species (ROS) (i.e., hydroxyl radicals – ·OH, hydrogen peroxide – H 2 O 2 , various atomic oxygen species, ozone-O 3 , hydroperoxyl radicals HO 2 ·) and reactive nitrogen species (RNS) (i.e., nitrogen oxides – NO, NO 2 , N 2 O - collectively termed NO X , nitrite-NO 2 - , nitrate-NO 3 - , peroxynitrite-ONOO - ). The hydroxyl radical is the critical species in many chemical oxidation reactions for chemical degradation of toxic compounds in water and gases and for synthesis of some compounds. The mixture of various nitrogen oxide species is important for many biochemical and biological processes involved in biomedical and agricultural applications including disinfection and fertilizer production. The present proposal focuses on determination of the effects of time resolved electron density and hydroxyl radicals on plasma chemical reactions through collaboration with the Princeton Collaborative Low Temperature Plasma Research Facility (PCRF) at the Princeton Plasma Physics Laboratory (PPPL). In order to further investigate the role of the plasma generated electrons and hydroxyl radicals on the overall formation of the key species including hydrogen peroxide, hydroxyl radicals, and nitrogen oxides, the proposed work, thus seeks to determine high resolution time resolved electron density by optical emissions spectroscopy and time resolved hydroxyl radicals using laser induced fluorescence in the nanosecond discharge reactor. The combination of data on electron density and hydroxyl radical concentration will be utilized in the present work to more fully characterize the chemical reaction processes in this system and to advance the design, development, and operation of such chemical reactors for a wide range of applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Segmented Energy Routing for a Modular AC/DC Hybrid System

This article presents a modular ac/dc system with both distributed and centralized power ports for energy router (ER) applications. In each module of the described system, photovoltaic (PV) power generation units, battery-type energy storage (ES) units, and critical loads are connected to the cascaded H-bridge (CHB)-organized medium-voltage (MV) dc links, with fully distributed low-voltage (LV) dc power ports. Copies of modules share the centralized load bus and interact with an MV ac grid in parallel. Hybrid power port (HPO) assigns flexibility to the system but makes energy routings a necessity for stable operation. In this article, a segmented energy management strategy for the HPO-ER is proposed. In terms of the grid-side power transferring, the system ratings are intentionally designed to match significant power imbalance. Focally, a segmented energy management strategy is proposed to realize fully autonomous energy routing involving MV ac grid, distributed PV generations, distributed battery storages, and LV load. The system is proven to be stable using the derived impedance-based model considering the interaction between power blocks. The feasibility of the topology and control strategy is also verified through software simulation, laboratorial hardware prototype experiment, and hardware-in-the-loop (HIL) emulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Rapid charging made practical in graphite-based lithium batteries: surface-acoustic wave turbulent electrolyte mixing to overcome diffusion limited charging rates [Final Report]

One of the key limits in rapidly recharging a lithium-ion battery is the depletion of lithium ions within the electrolyte adjacent the anode during charging and long diffusion time to overcome this depletion. It also causes dendrite formation, inefficient use of the lithium, and battery degradation over many charge-discharge cycles. Because the liquid electrolyte remains quiescent and unmixed, this depletion layer’s depth rapidly grows to match the anode-cathode separation distance at even modest charge rates. The solution proposed by PI Prof. James Friend and Co-PI Prof. Ping Liu, both from the University of California, San Diego, is to mix the electrolyte and minimize the Li+ ion concentration gradient during charging. Even in the presence of the separator, the charging rate could then be significantly increased. They propose to accomplish this using surface acoustic wave (SAW)-driven acoustic streaming, a technique employing 10-mW fingernail-sized solid-state devices from the telecommunications industry to drive turbulent mixing to submicron length scales in a manner completely compatible with the typical 20700 and 18650 cells used in electric vehicles. 0.1. Turbulent acoustic streaming mixes the electrolyte during charging—even with separator Our proposed 100-MHz SAW device used to recirculate the electrolyte is compatible with lithium- ion battery electrochemistry, as it is made in our lab of single-crystal lithium niobate. Their solution is straightforward to drive from a DC power source alongside the signal provided during battery charging. The device is only needed during charging and does not consume power dur- ing battery discharge. Uniquely, SAW generates extreme accelerations of over 1 billion meters per second squared in the fluid, driving turbulent mixing from centimeter to submicron length scales, even through the porous separator materials that tend to be used in batteries, all while avoiding interfering with the anode’s solid electrolyte interphase layer that forms during use. By employing novel fluid mechanics, the investigators are proposing a new direction for battery research away from direct use of materials science and electrochemistry. The chemistry agnostic solution may be employed in any battery chemistry that makes use of liquid electrolytes, providing a broader transformative benefit to the battery research community. They are to produce a series of prismatic and 20700-cell sized 2 Ah batteries capable of being charged and discharged at least 500 times without more than 20% loss in battery capacity, and to provide analysis tools useful to the battery research and development community for adopting this approach for other battery chemistries and configurations.

25 ENERGY STORAGE↗

Challenges and Gaps in the Development of Pulsed Power for Fusion Applications: A Preroadmapping Perspective From Industry, Academia, and National Laboratory Experts

Fusion energy meets the twenty-first century World Grand Challenge of sustainable, ubiquitous, and safer energy sources. However, harnessing the promise of fusion energy has proven elusive. The competing approaches to fusion power plant design include inertial confinement fusion, National Ignition Facility (ICF-NIF, Z machine, etc.,) magnetic confinement fusion (MCF-Tokamak, stellarators, etc.), and other approaches that show promise in small- (flow stabilized Z pinches) or large-scale applications. These approaches are being accelerated with private and public funding and seek to demonstrate the feasibility of different approaches to fusion-based power plants. Yet, how can the necessary pulsed power technologies for these disruptive technology bases be accelerated with no clear “Dominant Design?” Roadmapping holds the promise to identify and develop common critical pulsed power components for laboratory, prototype, and commercial fusion, and can accelerate the commercialization of fusion reactor designs. A preroadmapping Workshop on Pulsed Power for Fusion was held at the IEEE International Pulsed Power Conference in San Antonio, TX, USA, in June 2023. The workshop had 177 attendees. Here, the common elements for many of the ICF technologies vying for dominant design were identified. The advancement of these technologies through roadmapping will enhance commercial expectations that require their rapid and innovative development in the next five years, as well as the next five to ten years. The key technologies identified that underpin and limit the advancement of fusion power include pulsed power technologies such as energy storage, high-voltage switching, additive manufacturing, and modular pulsed power circuit topologies. In conclusion, they are the focus of our effort in the following roadmap scenario, which will delineate potential paths to technology development.

Curry, Randy D. [I-Pulse Group, Albuquerque, NM (U↗

Quadrupolar density structures in driven magnetic reconnection experiments with a guide field

Magnetic reconnection is a ubiquitous process in plasma physics, driving rapid and energetic events such as coronal mass ejections. Reconnection between magnetic fields with arbitrary shear can be decomposed into an anti-parallel reconnecting component and a non-reconnecting guide-field component, which is parallel to the reconnecting electric field. This guide field modifies the structure of the reconnection layer and the reconnection rate. We present results from experiments on the MAIZE pulsed-power generator (500 kA peak current, 200 ns rise time), which use two exploding wire arrays, tilted in opposite directions, to embed a guide field in the plasma flows with a relative strength b≡B g /B rec =0, 0.4, or 1. The reconnection layers in these experiments have widths that are less than the ion skin depth, d i =c/ω pi , indicating the importance of the Hall term, which generates a distinctive quadrupolar magnetic field structure along the separatrices of the reconnection layer. Using laser imaging interferometry, we observe quadrupolar structures in the line-integrated electron density, consistent with the interaction of the embedded guide field with the quadrupolar Hall field. Our measurements extend over much larger length scales (40d i ) at higher β (∼1) than previous experiments, providing an insight into the global structure of the reconnection layer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Device Voltage Stress from Ground Leakage Current in Medium-Voltage Solid-State Transformer

Grounding related issues are critical for safe and reliable operation of solid-state transformer (SST) in medium-voltage (MV) applications, e.g., solar photovoltaic and energy storage integration, date center, electric vehicle fast charging, etc. This article presents for the first time the issue of additional device voltage stress due to grounding-loop current in current-source SST, using the soft-switching solid-state transformer (S4T) as an example. The S4T features single-stage isolated AC-AC, AC-DC, or DC-DC conversion with full-range ZVS, derived from flyback converter or current-source converter (CSC). However, the flyback operation for CSC-based SST means that magnetizing current flows through the reverse-blocking devices on only one side of the medium-frequency transformer (MFT) at a time. Then, the voltages across the devices, especially those on the other side of the MFT, can be influenced by parasitic current. A parasitic model of a modular S4T (M-S4T) prototype is developed from direct measurements and datasheets. Using the developed parasitic model and equivalent circuits, the causes of the voltage stress are analyzed. A voltage-stress mitigation scheme of connecting additional grounding capacitors is proposed. Damping resistors are also installed to damp out the grounding-loop resonance. A robust parameter design of the proposed scheme is given. The existence of the voltage stress issue and the effectiveness of the proposed scheme are verified experimentally on an MV SiC M-S4T prototype with inherent parameter variations among the five modules in the prototype. Here, both single-module and stacked-module operation are demonstrated during steady state and dynamic conditions up to 4 kV peak.

42 ENGINEERING↗

Quantifying Properties for a Mechanistic, Predictive Understanding of Aqueous Impact on Aging of Medium and Low Voltage AC and DC Cabling in Nuclear Power Plants

To address the gap in knowledge in understanding degradation in relevant service conditions, this project aimed to develop a mechanistic, predictive model of medium and low voltage cable failure based on the primary environmental degradation parameters of aqueous immersion time, temperature, and the oxidation extent. To do so, we took a two-fold approach toward evaluating degradation as related to the aqueous condition. First, we evaluated the chemical, mechanical, and electrical properties of polymers that comprise the cabling insulation under varied aqueous conditions at different temperatures. Secondly, we evaluated the performance of insulation materials under similar accelerated aging conditions in addition to the dielectric breakdown of the cabling under submersion conditions. Thermal oxidation and immersion of LDPE thin films were done using a Parr vessel and the extent of oxidation was monitored using the carbonyl index from ATR-FTIR spectrum, a ratio quantifying the carbonyl functionality produced on the LDPE film surface. Increasing the temperature, oxidation time, and oxygen pressure increased the water-vapor permeability and the carbonyl content. Thermogravimetric analysis of the films confirmed that there is indeed an initial weight loss of the smaller molecular weight molecules and volatiles. At higher temperatures, there is a secondary mass loss. Up to 70°C, the mass loss curves were similar until 80°C, when the aged films decreased at a much greater rate with respect to increasing temperature. This was seen in the 10, 50, 90% weight loss temperatures. The mechanical properties of sheet PP and HDPE as well as injection molded LDPE, HDPE, HDPP dog bones were plotted with respect to the time spent in the Parr vessel during thermal oxidation. For the sheet PP and HDPE, the UTS and the modulus of elasticity decreased while the elongation increased. The injection-molded LDPE, HDPE, and HDPP dog bones experienced a similar trend where the changes in the properties were within experimental uncertainty. This analysis of LDPE in dry and immersive oxygen-rich environments is an important baseline for future experiments looking at other degradation mechanisms. A predictive aging model for low-density polyethylene insulative cable housings was developed. This model revealed a combination of physical and chemical processes which lead to an increase in permeability and a decrease in strength of the insulator. In creating this predictive model, a gap of knowledge in the literature was revealed in two areas: understanding how the crystallinity of a polymer changes with time and visualizing the predicted pores formed through the insulator which leads to failure. Developing and using an adapted ATR-FTIR method, crystallinity was monitored and compared to bulk crystallinity found via DSC. Inhomogeneity in crystallinity changes were observed but the FTIR method but was found to be less reliable. Pore visualization was found utilizing electrical impedance spectroscopy saturated aged polyethylene films with synthesized citrate-capped gold nanoparticles, and chloroauric acid precursor. results indicate a decreasing impedance of the polyethylene films caused by the transport of ions through the film. SEM imaging was then performed for elemental analysis of the films and counter electrodes for the presence of ions. Chloride and gold ions were detected; however, no nanoparticles were found. This gives an estimated pore size of at least 0.3 nm through the aged film. Cyclic submergence of polyethylene and polypropylene in aqueous solutions of copper sulfate and Harrison’s solution were examined. It was discovered that aging in these mixed conditions and at 90°C did cause a small, yet significant increase to tensile strength for both unaged polyethylene and polypropylene. The PE and PP in cycled and submerged conditions did not have tensile strengths significantly different from dry-aged after 16 weeks. For both solutions, it was determined that capacitance increases with both water tree depth and cable temperature and is relatively independent of changing water tree AR. As for resistance, there is no apparent change between depth percentages of 10 and 80 for both solutions. This is because the water tree has not yet entered the conductor and thus there is no shorting current flowing through the tree yet. Between 80 and 100% water tree depth, it is observed that for both solutions there is a rapid decrease in resistance because the tree is now impacting the conductor shield and allowing shorting current to flow through it. The relationship between resistance and temperature was found to be inversed. As temperature increases, resistance decreases for both water tree solutions with distilled water having the most apparent difference across the range of temperatures simulated. With regards to water tree AR, resistance was found to be relatively independent at depth percentages of 10, 50, and 70, but there was some relationship at 100% depth for both solutions. At this depth, as water tree AR increased, resistance was found to also increase. Through the examination of voltage and electric field distribution plots, it was confirmed for EPR cables that increasing water tree depth leads to increasing distortion. The increase in shorting current at 100% depth for aqueous copper sulfate compared to distilled water was also visualized. Lastly, the relationship between shorting current and temperature for narrow water trees was visualized and validated using the distribution plots. This study has led to a better understanding of the effect of cable temperature, water tree solution, and geometry of the tree region on cable degradation. Furthermore, this study has documented simulation results of water tree degradation in EPR MV cables, which had been previously lacking in information. Future work in this area will add frequency into the mix and examine what effect it has on the rate of cable degradation as a result of water treeing. To compliment the work being carried by UMD on different polymer chemistries, harvested medium voltage (MV) cables were selected for accelerated aging study at ORNL. These medium voltage cables are representative of the vintages and materials that are currently in use at existing nuclear power plants (NPPs). These cables were immersed in water at 90°C and energized for a period of two years at elevated voltage. Partial discharge was measured during this period of time to track potential degradation. Unfortunately, due to the absence of failure, the extent of integration between the UMD techniques and the harvested MV insulation was limited. However, based on the findings and from the UMD research in the previous sections on polyethylene and polypropylene, follow-on characterization for harvested MV cable insulation should focus on sample preparation to take advantage of the UMD techniques to better understand mechanistic degradation in MV cable insulations. This would include: 1.) Utilization of solutions and impedance measurement insulation to track permeability in harvested and accelerated aging insulation samples, 2.) Adaptation of gold nanoparticle synthesis for electrical impedance spectroscopy with supporting SEM characterization to study pore formation in harvested and accelerated aged insulation samples, & 3.) ATR-FTIR crystallinity with multiple temperature dependent harvested MV cable insulation under different air and submerged accelerated aging. In addition, low voltage dielectric spectroscopy and high voltage dissipation factor, tan δ, could be implemented as a condition monitoring tool for harvested MV cable insulation in submerged environments.

24 POWER TRANSMISSION AND DISTRIBUTION↗