Comparing directed efficiency of III-nitride nanowire light-emitting diodes
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Here, in this work, the optical efficiency of III-nitride blue micro-LEDs (μLEDs) ranged from 5 × 5 to 60 × 60 μm 2 with different sidewall treatments at low current density range was investigated. The results showed dielectric sidewall passivation using atomic layer deposition (ALD) has superior optical enhancement compared to conventional RF sputtering, where most of the enhancement occurred at low current density range. Additionally, the use of ALD sidewall passivation and chemical treatment offered significant efficiency improvement for different sizes of μLEDs at operating less than 1 A cm −2 and the devices without sidewall treatments did not emit light. The effect of sidewall treatments to the effective Shockley–Read–Hall (SRH) nonradiative recombination coefficient, or the effective A coefficient from the ABC model, was estimated. The effective SRH nonradiative recombination coefficient was suppressed by two orders of magnitude for devices with sidewall treatments compared to devices without sidewall passivation.
Explore the source record for details and available documents.
The data processing and calculation of statistical parameters was performed by the Tektronix computer system. The data acquired for easy vendor to vendor and date code to date code analysis are summarized. Each parameter is presented with test conditions, mean, standard deviation, lowest reading, 10% point (where 10% of all readings are equal to or less than the indicated reading), 90% point (where 90% of all readings are equal to or less than the indicated reading) and the highest reading.
The necessary data to create a new class of specifications was the objective of this characterization program. Sample selection was made according to the following criteria: (1) manufacturer or qualified distributor; (2) two vendors; and (3) two date codes. The general guidelines for procurement were two QPL vendors, JAN or JANTX, and two manufacturing lots, 27 from each lot. All data were acquired with three digit accuracy. The data processing and calculation of statistical parameters were performed by the Tektronix computer system using 4 digit display.
The derivation of a simple expression for the capacitance C(V) associated with the transition region of a p-n junction under a forward bias is derived by phenomenological reasoning. The treatment of C(V) is based on the conventional Shockley equations, and simpler expressions for C(V) result that are in general accord with the previous analytical and numerical results. C(V) consists of two components resulting from changes in majority carrier concentration and from free hole and electron accumulation in the space-charge region. The space-charge region is conceived as the intrinsic region of an n-i-p structure for a space-charge region markedly wider than the extrinsic Debye lengths at its edges. This region is excited in the sense that the forward bias creates hole and electron densities orders of magnitude larger than those in equilibrium. The recent Shirts-Gordon (1979) modeling of the space-charge region using a dielectric response function is contrasted with the more conventional Schottky-Shockley modeling.
Abstract not provided.
Abstract not provided.
Purpose: It has been reported that diode sensitivity decreases by as much as 2% when the average dose rate set at the accelerator console was decreased from 600 to 40 MU/min. No explanation was given for this effect in earlier publications. This work is a detailed investigation of this phenomenon: the change of diode sensitivity versus the rate of delivery of dose pulses in the milliseconds and seconds range. Methods: X-ray beams used in this work had nominal energies of 6 and 15 MV and were generated by linear accelerators. The average dose rate was varied from 25 to 600 MU/min, which corresponded to time between microsecond-long dose pulses of 60-2.7 ms, respectively. The dose-per-pulse, dpp, was changed by positioning the detector at different source-to-detector distance. A variety of diodes fabricated by a number of manufacturers were tested in this work. Also, diodes in three different MapCHECKs (Sun Nuclear, Melbourne, FL) were tested. Results: For all diodes tested, the diode sensitivity decreases as the average dose rate is decreased, which corresponds to an increase in the pulse period, the time between radiation pulses. A sensitivity decrease as large as 5% is observed for a 60-ms pulse period. The diode sensitivity versus the pulse period is modeled by an empirical exponential function. This function has a fitting parameter, t{sub eff}, defined as the effective lifetime. The values of t{sub eff} were found to be 1.0-14 s, among the various diodes. For all diodes tested, t{sub eff} decreases as the dpp decreases and is greater for 15 MV than for 6 MV x rays. The decrease in diode sensitivity after 20 s without radiation can be reversed by as few as 60 radiation pulses. Conclusions: A decrease in diode sensitivity occurs with a decrease in the average dose rate, which corresponds to an increase in the pulse period of radiation. The sensitivity decrease is modeled by an empirical exponential function that decreases with an effective lifetime, t{sub eff}, of 1.0-14 s. t{sub eff} varies widely for different diodes, dpp, and x-ray energy. It is hypothesized that the capture of excess minority carriers by charge traps, cause the observed decrease in diode sensitivity. Also, it is hypothesized that the slow reopening of these traps occurs in the hundreds of milliseconds to seconds range at ambient temperature and this underlies the slow decrease in the diode sensitivity. Calibration of a diode is best done at the average dose rate with which it will be used. This is easily accomplished for radiation deliveries in which the average dose rate is a constant. However, for a VMAT delivery the average dose rate is a variable. For measurements made under these conditions diodes can be calibrated with a median or average dose rate which splits the difference in diode sensitivity that is known to occur with changes in average dose rate.
Purpose: Silicon diodes are widely used as detectors for relative dose measurements in radiotherapy. The common manufacturing practice is to encapsulate the diodes in plastic for protection and to facilitate mounting in scanning devices. Diodes intended for use in photon fields commonly also have a shield of a high atomic number material (usually tungsten) integrated into the encapsulation to selectively absorb low-energy photons to which silicon diodes would otherwise over-response. However, new response models based on cavity theories and spectra calculations have been proposed for direct correction of the readout from unshielded (e.g., ''electron'') diodes used in photon fields. This raises the question whether it is correct to assume that the spectrum in a water phantom at the location of the detector cavity is not perturbed by the detector encapsulation materials. The aim of this work is to investigate the spectral effects of typical encapsulations, including shielding, used for clinical diodes. Methods: The effects of detector encapsulation of an unshielded and a shielded commercial diode on the spectra at the detector cavity location are studied through Monte Carlo simulations with PENELOPE-2005. Variance reduction based on correlated sampling is applied to reduce the CPU time needed for the simulations. Results: The use of correlated sampling is found to be efficient and to not introduce any significant bias to the results. Compared to reference spectra calculated in water, the encapsulation for an unshielded diode is demonstrated to not perturb the spectrum, while a tungsten shielded diode caused not only the desired decrease in low-energy scattered photons but also a large increase of the primary electron fluence. Measurements with a shielded diode in a 6 MV photon beam proved that the shielding does not completely remove the field-size dependence of the detector response caused by the over-response from low-energy photons. Response factors of a properly corrected unshielded diode were shown to give comparable, or better, results than the traditionally used shielded diode. Conclusions: Spectra calculated for photon fields in water can be directly used for modeling the response of unshielded silicon diodes with plastic encapsulations. Unshielded diodes used together with appropriate corrections can replace shielded diodes in photon dose measurements.
Fluidic diodes are presently being considered for use in several fluoride salt-cooled high-temperature reactor designs. A fluidic diode is a passive device that acts as a leaky check valve. These devices are installed in emergency heat removal systems that are designed to passively remove reactor decay heat using natural circulation. The direct reactor auxiliary cooling system (DRACS) uses DRACS salt-to-salt heat exchangers (DHXs) that operate in a path parallel to the core flow. Because of this geometry, under normal operating conditions some flow bypasses the core and flows through the DHX. A flow diode, operating in reverse direction, is-used to minimize this flow when the primary coolant pumps are in operation, while allowing forward flow through the DHX under natural circulation conditions. The DRACSs reject the core decay heat to the environment under loss-of-flow accident conditions and as such are a reactor safety feature. Fluidic diodes have not previously been used in an operating reactor system, and therefore their characteristics must be quantified to ensure successful operation. This report parametrically examines multiple design parameters of a vortex-type fluidic diode to determine the size of diode needed to reject a particular amount of decay heat. Additional calculations were performed to size a scaled diode that could be tested in the Oak Ridge National Laboratory Liquid Salt Flow Loop. These parametric studies have shown that a 152.4 mm diode could be used as a test article in that facility. A design for this diode is developed, and changes to the loop that will be necessary to test the diode are discussed. Initial testing of a scaled flow diode has been carried out in a water loop. The 150 mm diode design discussed above was modified to improve performance, and the final design tested was a 171.45 mm diameter vortex diode. The results of this testing indicate that diodicities of about 20 can be obtained for diodes of this size. Experimental results show similar trends as the computational fluid dynamics (CFD) results presented in this report; however, some differences exist that will need to be assessed in future studies. The results of this testing will be used to improve the diode design to be tested in the liquid salt loop system.
The negative polarity rod pinch diode (NPRPD) is a potential millimeter spot size radiography source for high voltage generators (4 to 8 MV) [Cooperstein et al., 'Considerations of rod-pinch diode operation in negative polarity for radiography,' in Proceedings of the 14th IEEE Pulsed Power Conference, 2003, pp. 975-978]. The NPRPD consists of a small diameter (few mm) cylindrical anode extending from the front end of the vacuum cell through a thin annular cathode, held by a central conductor. The polarity has been inverted when compared to the original rod pinch diode [Cooperstein et al., 'Theoretical modeling and experimental characterization of a rod-pinch diode,' Phys. Plasmas 8(10), 4618-4636 (2001)] in order to take advantage from the maximal x-ray emission toward the anode holder at such a voltage [Swanekamp et al., 'Evaluation of self-magnetically pinched diodes up to 10 MV as high resolution flash X-ray sources,' IEEE Trans. Plasma Sci. 32(5), 2004-2016 (2004). We have studied this diode at 4.5 MV, driven by the ASTERIX generator [Raboisson et al., 'ASTERIX, a high intensity X-ray generator,' in Proceedings of the 7th IEEE Pulsed Power Conference, 1989, pp. 567-570.]. This generator, made up of a capacitor bank and a Blumlein line, was initially designed to test the behavior of electronic devices under irradiation. In our experiments, the vacuum diode has been modified in order to set up flash a radiographic diode [Etchessahar et al., 'Negative polarity rod pinch diode experiments on the ASTERIX generator,' in Conference Records-Abstracts, 37th IEEE International Conference on Plasma Science, 2010]. The experiments and numerical simulations presented here allowed the observation and analysis of various physical phenomena associated with the diode operation. Also, the influence of several experimental parameters, such as cathode and anode diameters, materials and surface states, was examined. In order to achieve the most comprehensive characterization of the diode, both optical and x-ray diagnostics were used, including high speed multi-image ICCD (intensified CCD) cameras, streak camera, dosimeters, spot size measurements, and pinhole cameras. A set of new results have been obtained through this study. The plasma emission from the anode and cathode surfaces and its expansion appear to be critical for the diode functioning. Also, for the first time, potential sources of diode instability were identified. Finally, an optimal and stable diode configuration was found with the following parameters: 52 rad at 1 m (in Al) and 2.2 mm spot size.