Search NASA⌕ Search

SEARCH · Search NASA

Results for “DOSIMETRY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Solar particle events observed at Mars: dosimetry measurements and model calculations

During the period from March 13, 2002 to mid-September, 2002, six solar particle events (SPE) were observed by the MARIE instrument onboard the Odyssey Spacecraft in Martian Orbit. These events were observed also by the GOES 8 satellite in Earth orbit, and thus represent the first time that the same SPE have been observed at these separate locations. The characteristics of these SPE are examined, given that the active regions of the solar disc from which the event originated can usually be identified. The dose rates at Martian orbit are calculated, both for the galactic and solar components of the ionizing particle radiation environment. The dose rates due to galactic cosmic rays (GCR) agree well with the HZETRN model calculations. Published by Elsevier Ltd on behalf of COSPAR.

Non-NASA Center↗

The Application of FLUKA to Dosimetry and Radiation Therapy

Monte Carlo transport codes like FLUKA are useful for many purposes, and one of those is the simulation of the effects of radiation traversing the human body. In particular, radiation has been used in cancer therapy for a long time, and recently this has been extended to include heavy ion particle beams. The advent of this particular type of therapy has led to the need for increased capabilities in the transport codes used to simulate the detailed nature of the treatment doses to the Y ~ ~ O U S tissues that are encountered. This capability is also of interest to NASA because of the nature of the radiation environment in space.[l] While in space, the crew members bodies are continually being traversed by virtually all forms of radiation. In assessing the risk that this exposure causes, heavy ions are of primary importance. These arise both from the primary external space radiation itself, as well as fragments that result from interactions during the traversal of that radiation through any intervening material including intervening body tissue itself. Thus the capability to characterize the details of the radiation field accurately within a human body subjected to such external 'beams" is of critical importance.

Wilson, Thomas L.↗

Active Solid State Dosimetry for Lunar EVA

The primary threat to astronauts from space radiation is high-energy charged particles, such as electrons, protons, alpha and heavier particles, originating from galactic cosmic radiation (GCR), solar particle events (SPEs) and trapped radiation belts in Earth orbit. There is also the added threat of secondary neutrons generated as the space radiation interacts with atmosphere, soil and structural materials.[1] For Lunar exploration missions, the habitats and transfer vehicles are expected to provide shielding from standard background radiation. Unfortunately, the Lunar Extravehicular Activity (EVA) suit is not expected to afford such shielding. Astronauts need to be aware of potentially hazardous conditions in their immediate area on EVA before a health and hardware risk arises. These conditions would include fluctuations of the local radiation field due to changes in the space radiation field and unknown variations in the local surface composition. Should undue exposure occur, knowledge of the dynamic intensity conditions during the exposure will allow more precise diagnostic assessment of the potential health risk to the exposed individual.[2]

Wrbanek, John D.↗

Genetic and Molecular Dosimetry of Hze Radiation

One of the unavoidable risks of spaceflight is exposure to the complex space radiation enviroment which can result in a 50-fold increase in exposure relative to like at the surface of the earth.

electromagnetic radiation HZE particles radiation ↗

Microdosimeter Instrument (MIDN-II) for Personnel Dosimetry

This group of collaborators has been funded, by the National Space Biomedical Research Institute (NSBRI) and the U. S. National Aeronautics and Space Administration (NASA) as of February, 2009 to develop a prototypic dosimeter/microdosimeter instrument that measures in real time the radiation risk to personnel in a time varying radiation field of possibly unknown composition. The microdosimetric detectors will be solid-state devices more compact, more rugged than conventional microdosimetric proportional counters used previously in space and will consume less power. The proposed detector will be based on the heritage of the MIDN-MidSTAR microdosimeter launched on the MidSTAR spacecraft on March, 2007, the only solid-state microdosimeter ever flown in space. The system will be suitable for measurements in spacesuits, spacecrafts, remote rovers, or other dynamic or static environments. Measurements as a function of time will not only provide the instantaneous and average absorbed physical dose but also corresponding microdosimetric spectra, dose rates, the dose equivalents, and the dose equivalent rates. Values of the dose equivalents are used to establish relative risks for humans exposed to radiation and to determine regulatory limits. Because these parameters will be available to the astronauts and mission control in real time, these systems can be used not only to quantify exposures and limits, but also to allow appropriate actions to be taken to reduce radiation exposures and their consequences. Earlier prototypes have been used successfully to characterize beams of energetic protons and heavier ions including carbon, oxygen, silicon, titanium, and iron at the NASA Space Radiation Laboratory at Brookhaven National Laboratory. The initial design will be presented and discussed and spectra will be presented.

Pisacane, V. L.↗

Biological Dosimetry in Astronauts

Biodosimetry data provides a direct measurement of space radiation damage, which takes into account individual radiosensitivity in the presence of confounding factors such as microgravity and other stress conditions. In contrast to physical measurements, which are external to body and require multiple devices to detect all radiation types all of which have poor sensitivity to neutrons, biodosimetry is internal and includes the effects of shielding provided by the body itself plus chromosome damage shows excellent sensitivity to protons, heavy ions, and neutrons. Moreover, chromosome damage maybe reflective of cancer risk and biodosimetry values can therefore be used to validate and develop risk assessment models that can be used to characterize excess health risk incurred by crewmembers. Cytogenetic biodosimetry methods have been used extensively for assessing terrestrial radiation exposures, and remain the most sensitive in vivo indicator of dose available to date. The main cellular radiation target is the DNA, and radiation-induced damage in the DNA molecule can be visualized as aberrations in the chromosomes (breaks in the chromosomes or exchanges of DNA material between different chromosomes). Normal chromosomes contain a single condensed and constricted area called a centromere that helps the chromosome number to remain stable when a cell divides.

George, Kerry↗

Radiation Dosimetry via Automated Fluorescence Microscopy

A developmental instrument for assessment of radiation-induced damage in human lymphocytes includes an automated fluorescence microscope equipped with a one or more chargecoupled- device (CCD) video camera(s) and circuitry to digitize the video output. The microscope is also equipped with a three-axis translation stage that includes a rotation stage, and a rotary tray that holds as many as thirty specimen slides. The figure depicts one version of the instrument. Once the slides have been prepared and loaded into the tray, the instrument can operate unattended. A computer controls the operation of the stage, tray, and microscope, and processes the digital fluorescence-image data to recognize and count chromosomes that have been broken, presumably by radiation. The design and method of operation of the instrument exploit fluorescence in situ hybridization (FISH) of metaphase chromosome spreads, which is a technique that has been found to be valuable for monitoring the radiation dose to circulating lymphocytes. In the specific FISH protocol used to prepare specimens for this instrument, metaphase lymphocyte cultures are chosen for high mitotic index and highly condensed chromosomes, then several of the largest chromosomes are labeled with three of four differently colored whole-chromosome-staining dyes. The three dyes, which are used both individually and in various combinations, are fluorescein isothiocyanate (FITC), Texas Red (or equivalent), and Cy5 (or equivalent); The fourth dye 4',6-diamidino- 2-phenylindole (DAPI) is used as a counterstain. Under control by the computer, the microscope is automatically focused on the cells and each slide is scanned while the computer analyzes the DAPI-fluorescence images to find the metaphases. Each metaphase field is recentered in the field of view and refocused. Then a four-color image (more precisely, a set of images of the same view in the fluorescent colors of the four dyes) is acquired. By use of pattern-recognition software developed specifically for this instrument, the images in the various colors are processed to recognize the metaphases and count the chromosome fragments of each color within the metaphases. The intermediate results are then further processed to estimate the proportion of cells that have suffered genetic damage. The prototype instrument scans at an average areal rate of 4.7 mm2/h in unattended operation, finding about 14 metaphases per hour. The false-alarm rate is typically less than 3 percent, and the metaphase-miss rate has been estimated to be less than 5 percent. The counts of chromosomes and fragments thereof are 50 to 70 percent accurate.

Castleman, Kenneth R.↗

Current Active Detectors for Dosimetry and Spectrometry on the International Space Station

We present a high-level overview of two of the most important radiation detection systems currently flying aboard the International Space Station(ISS), ISS-RAD and Timepix. ISS-RAD is a single, large unit that is capable of detecting both chargedand neutral high-energy particles. For most of its first three and a half years of operations onboard Station, ISS-RAD has been periodically moved to different modules, includingtheUSLab, Columbus, JEM, Node2, and Node3. In contrast, the much smaller Timepix-based detectors are deployed in several locations around the station. The first generation of these units were known as REMs, or Radiation Environment Monitors. A second generation has recently been deployed, known as REM-2 units. We will briefly describe the technologies used in these systems and their capabilities.

Cary Zeitlin↗

On-Chip p-MOSFET Dosimetry

On-chip p-FETs were developed to monitor the radiation dose of n-well CMOS ICs by monitoring the threshold voltage shifts due to radiation induced oxide and interface charge.

FET's↗

On-Chip p-MOSFET Dosimetry

On-chip p-FETs were developed to monitor the radiation dose of n-well CMOS ICs by monitoring threshold voltage shifts due to radiation induced oxide and interface charge.

FETs↗

LDEF geometry/mass model for radiation analyses

A 3-D geometry/mass model of Long Duration Exposure Facility (LDEF) was generated to aid in the interpretation of ionizing radiation experiments relative to the influence of varying shielding distributions around the dosimetry, and to allow more definitive calculations and comparisons with the measured data. This model takes into account the major individual structural members of the LDEF spacecraft, the mass in each experiment tray, and, for selected trays containing ionizing radiation dosimetry, major parts within the tray are modeled. The geometry/mass model, together with a ray tracing algorithms, was programmed for use both as a stand alone code in determining 3-D shielding distributions at dosimetry locations, and as a geometry module that can be interfaced with radiation transport codes.

Colborn, B. L.↗

Depth Dose Distribution Study within a Phantom Torso after Irradiation with a Simulated Solar Particle Event at NSRL

The adequate knowledge of the radiation environment and the doses incurred during a space mission is essential for estimating an astronaut's health risk. The space radiation environment is complex and variable, and exposures inside the spacecraft and the astronaut's body are compounded by the interactions of the primary particles with the atoms of the structural materials and with the body itself Astronauts' radiation exposures are measured by means of personal dosimetry, but there remains substantial uncertainty associated with the computational extrapolation of skin dose to organ dose, which can lead to over- or underestimation of the health risk. Comparisons of models to data showed that the astronaut's Effective dose (E) can be predicted to within about a +10% accuracy using space radiation transport models for galactic cosmic rays (GCR) and trapped radiation behind shielding. However for solar particle event (SPE) with steep energy spectra and for extra-vehicular activities on the surface of the moon where only tissue shielding is present, transport models predict that there are large differences in model assumptions in projecting organ doses. Therefore experimental verification of SPE induced organ doses may be crucial for the design of lunar missions. In the research experiment "Depth dose distribution study within a phantom torso" at the NASA Space Radiation Laboratory (NSRL) at BNL, Brookhaven, USA the large 1972 SPE spectrum was simulated using seven different proton energies from 50 up to 450 MeV. A phantom torso constructed of natural bones and realistic distributions of human tissue equivalent materials, which is comparable to the torso of the MATROSHKA phantom currently on the ISS, was equipped with a comprehensive set of thermoluminescence detectors and human cells. The detectors are applied to assess the depth dose distribution and radiation transport codes (e.g. GEANT4) are used to assess the radiation field and interactions of the radiation field with the phantom torso. Lymphocyte cells are strategically embedded at selected locations at the skin and internal organs and are processed after irradiation to assess the effects of shielding on the yield of chromosome damage. The initial focus of the present experiment is to correlate biological results with physical dosimetry measurements in the phantom torso. Further on, the results of the passive dosimetry within the anthropomorphic phantoms represent the best tool to generate reliable data to benchmark computational radiation transport models in a radiation field of interest. The presentation will give first results of the physical dose distribution, the comparison with GEANT4 computer simulations based on a Voxel model of the phantom, and a comparison with the data from the chromosome aberration study.

Berger, Thomas↗

Status - International Space Station (ISS) Crewmembers' Noise Exposures

Environmental noise in space vehicles, caused by onboard equipment and crew activities, has generated concerns for crew health and safety since early U.S. space missions. The International Space Station (ISS) provides a unique environment where acoustic conditions can be monitored while crewmembers from the U.S. and their international partners work and live for as long as 6 to 12 consecutive months. This review of acoustic dosimetry data collected to date reveals that the noise exposure limits of NASA’s stringent noise constraint flight rule have been exceeded in 41% of these dosimetry measurements since ISS Increment 17 (2008), with undefined impacts to crew. These measurements do not take into account the effects of hearing protection devices worn by the crew. The purpose of this paper is to provide an update on ISS noise exposure monitoring approaches and hearing conservation strategies that include acoustic dosimetry data collected since the ISS Increment 55 mission (April 2018). Future directions and recommendations for the ISS noise exposure monitoring program will also be presented, including research initiatives aimed at better defining the impact of ISS noise on crew health and performance.

Jose G Limardo↗

Status - International Space Station (ISS) Crewmembers' Noise Exposures

Environmental noise in space vehicles caused by onboard equipment and noisy activities has generated concerns for crew health and safety since early U.S. space missions. The International Space Station (ISS) provides a unique environment where acoustic conditions can be monitored while crewmembers from the U.S. and their international partners work and live for as long as 6 to 12 consecutive months. This review of acoustic dosimetry data collected to date reveals that the noise exposure limits of NASA’s stringent noise constraint flight rule have been exceeded in 41% of these dosimetry measurements since ISS Increment 17 (2008), with undefined impacts to crew. These measurements do not take into account the effects of hearing protection devices worn by the crew. The purpose of this paper is to provide an update on ISS noise exposure monitoring approaches and hearing conservation strategies that include acoustic dosimetry data collected since the ISS Increment 55 mission (April 2018). Future directions and recommendations for the ISS noise exposure monitoring program will also be presented, including research initiatives aimed at better defining the impact of ISS noise on crew health and performance.

Jose G Limardo↗