Search NASA⌕ Search

SEARCH · Search NASA

Results for “DR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Preeclampsia and blood lead (and other metals) in Lubumbashi, DR Congo

Among parturient women in Lubumbashi, blood lead concentrations [geometric means (25th–75th percentiles)] were higher among 40 women with preeclampsia [6.66 µg/dL (5.16–79.4)] than among 39 control women matched for age and gestation duration [5.08 µg/dL (4.27–6.30)]. Blood lead exceeded 5 µg/dL in 33 (83%) preeclamptic women and 17 (44%) control women [odds ratio 6.1 (95%CI 2.1–17.1)]. In another study, we found high levels of lead in surface dust collected in front of homes in Lubumbashi (36/127 samples exceeding 120 µg lead/g dust). Our findings support the conclusions of a systematic review that increased blood lead level increases the likelihood of preeclampsia. Moreover, our study indicates that, as in other urban areas in Africa, exposure to lead is unacceptably high among pregnant women in Lubumbashi. Preventive measures are needed to protect mothers and children from the serious adverse effects of lead exposure.

54 ENVIRONMENTAL SCIENCES↗

Information Loss Via Visual Assessment of Radiologic Images Using Modified Version of the Low-Contrast Detailed Phantom at Direct DR System

Quality in radiology images can be assessed by determining the levels of information retained or lost in an image. Information loss in images has been recently assessed via a method based on information theory and the employment of a contrast-detail (CD) phantom. In this study, the traditional CD phantom (air-Perspex) and a modified CD phantom were used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ex vivo detection of adenovirus specific CD4{sup +} T-cell responses to HLA-DR-epitopes of the Hexon protein show a contracted specificity of T{sub HELPER} cells following stem cell transplantation

Human adenovirus (HAdV) is a cause of significant morbidity and mortality in immunocompromised patients, especially after stem cell transplantation (SCT). Viral clearance has been attributed to CD4{sup +} T-cell responses against the Hexon-protein, but the frequency of specific T{sub HELPER} cells is extremely low or not detectable ex vivo and preference for different CD4{sup +} T-cell epitopes is variable among individuals. We therefore analyzed 44 healthy donors and 6 SCT-recipients for Hexon-specific CD4{sup +}-responses ex vivo, to identify epitopes which would be broadly applicable. We selected 19 candidate epitopes with predicted restriction to HLA-DR1/DR3/DR4/DR7; 16 were located within the highly conserved regions, indicating cross-reactivity of T cells among HAdV-subspecies. Ten epitopes induced CD4{sup +}-proliferation in >50% of individuals, confirmed by intracellular IFN-gamma detection. Three SCT recipients who recovered from an infection with HAdV displayed reactivity towards only a single hexon epitope, whereas healthy individuals were responsive to two to eight epitopes (median 3). The ex vivo detection of Hexon-specific CD4{sup +} T-cells, without any long-term culture in vitro, enables the detection and generation of HAdV-specific CD4{sup +} T cells for adoptive T-cell transfer against HAdV-infection post SCT.

60 APPLIED LIFE SCIENCES↗

MHC-II dynamics are maintained in HLA-DR allotypes to ensure catalyzed peptide exchange

Presentation of antigenic peptides by major histocompatibility complex class II (MHC-II) proteins determines T helper cell reactivity. The MHC-II genetic locus displays a large degree of allelic polymorphism influencing the peptide repertoire presented by the resulting MHC-II protein allotypes. During antigen processing, the human leukocyte antigen (HLA) molecule HLA-DM (DM) encounters these distinct allotypes and catalyzes exchange of the placeholder peptide CLIP by exploiting dynamic features of MHC-II. Here, we investigate 12 highly abundant CLIP-bound HLA-DRB1 allotypes and correlate dynamics to catalysis by DM. Despite large differences in thermodynamic stability, peptide exchange rates fall into a target range that maintains DM responsiveness. A DM-susceptible conformation is conserved in MHC-II molecules, and allosteric coupling between polymorphic sites affects dynamic states that influence DM catalysis. As exemplified for rheumatoid arthritis, we postulate that intrinsic dynamic features of peptide–MHC-II complexes contribute to the association of individual MHC-II allotypes with autoimmune disease.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DR-RINS: Digital real-time relative intensity noise suppressor for pump–probe spectroscopy and microscopy

Relative intensity noise (RIN) inherent in fiber lasers poses a serious obstacle to their use in pump–probe spectroscopy and imaging. RIN can be removed through an analog balanced detector, or, as we have previously shown, software adaptive noise cancellation (ANC) on digitized signals. One major drawback to software ANC is the added time required for digitizing and post-processing. In this article, we describe a design for ANC on a field-programmable gate array (FPGA), making use of high-level synthesis tools and fixed-point arithmetic to achieve real-time laser RIN suppression at 25 MHz sample rates. Unlike the software-ANC approach, the FPGA-ANC device can serve as a dedicated drop-in denoiser, placed between the detectors and a commercial lock-in amplifier. We demonstrate its application to transient absorption spectroscopy and microscopy, lowering the noise floor to ~17 dB above the shot noise limit. Furthermore, we demonstrate a dramatic improvement in data acquisition time from ~6 h to ~5 min in a real-time imaging scenario.

47 OTHER INSTRUMENTATION↗

Relationship between Aerosols, Hail Microphysics, and Z DR Columns

Mechanisms of formation of differential reflectivity columns are investigated in simulations of a midlatitude summertime hailstorm with hailstones up to several centimeters in diameter. Simulations are performed using a new version of the Hebrew University Cloud Model (HUCM) with spectral bin microphysics. A polarimetric radar forward operator is used to calculate radar reflectivity and differential reflectivity ZDR. It is shown that ZDR columns are associated with raindrops and with hail particles growing in a wet growth regime within convective updrafts. The height and volume of ZDR columns increases with an increase in aerosol concentration. Small hail forming under clean conditions grows in updrafts largely in a dry growth regime corresponding to low ZDR. Characteristics of ZDR columns are highly correlated with vertical velocity, hail size, and aerosol concentration.

54 ENVIRONMENTAL SCIENCES↗

Technical Advice and Support for the Joint Integrated Non-Intrusive Inspection (JINII) Program Task 2.2 Transmission Digital Radiography (DR)

The Cargo Advanced Automated Radiography System (CAARS) program aims to utilize advanced radiographic systems to detect radiological and nuclear threats. Validation of initial design and testing concepts is a precondition for prototype system development and large-scale deployment. As expected, Depleted Uranium (DU) is a valid surrogate for Special Nuclear Materials (SNM) in CAARS Advanced Technology Demonstration (ATD) performance field-tests of transmission radiography systems. Dual-energy transmission measurements of DU are nearly identical to SNM, and are distinct from lower Z materials, provided the samples are matched to equal areal density. Results from an alternative method, using samples of equal thickness, showed sample discrimination by material density, rather than by atomic number (Z). The transmission measurements of DU and SNM were made with equipment that is nearly identical to current field systems. X-ray source beams at endpoint energies of 5.4 MeV and 9.6 MeV were used to measure transmission through the selected sample materials. The ratio of the x-ray linear attenuation coefficient times length ({micro}L) at 5.4 MeV, to {micro}L at 9.6 MeV is a metric for atomic number based discrimination of materials. The measured ratios were compared with computed values based on LLNL photon cross section data and LLNL developed models of x-ray detector characteristics. Measured ratios for DU differed from HEU by an average of 0.25%, and from WGPu by 0.08%, which is within the noise level of 0.4 to 0.5%. For comparison, measured ratios for Sn differed from HEU by 3.2%, and from WGPu by 3.6%, well beyond the measurement noise. Measured ratios for W differed from HEU by 0.01%, and from WGPu by 0.32%. The measured ratio values presented in Table 1 demonstrate the feasibility of using a threshold ratio to discriminate low-Z (Z < 72) from high-Z (Z {ge} 72) materials (as defined by CAARS specification). In the case of our test system, a threshold ratio of 1.08 would be suitable based on the measured results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗