Search NASA⌕ Search

SEARCH · Search NASA

Results for “DRY HEAT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

CFD-Chemical Model of One-Third Scale Demonstration of DOE Sealed Canister with ATR Fuel

Road-ready and final disposition packaging configurations for the advanced test reactor (ATR) fuel currently specifies storage within helium backfilled DOE sealed standard canisters. The aluminum cladding of the ATR fuel contains an oxyhydroxide layer of boehmite/bayerite that generates hydrogen when subjected to irradiation. Understanding the effect of this hydrogen buildup over time to important for long term storage considerations. Previous modeling efforts have built a coupled CFD-chemical model to simulate the temperature gas phase concentrations within the DOE sealed standard canisters. A demonstration case for these DOE sealed canisters will be eventually performed with a one-third scale mockup that has been instrumented with thermocouples and gas concentration probes. This study seeks to model the planned canister for validation of the previously developed model, such that confidence in its long-term prediction can be increased. The deployment of the instrumented lid for online monitoring in intended for a period of 10+ years based on previous monitoring of commercial fuel storage; however, the model is still run for the previously used 50-year storage periods. This case is modeled with a G-value using a bi-linear function such that it decreases at higher dose rates to be consistent with experiments. Validation efforts of the model would likely revolve around the results for the 1st year, so the results of this timeframe are also highlighted. For dried fuel of the nominal decay heat (18W), the predicted hydrogen concentration is 0.19% after 1 year, 0.91% after 10 years, and 2.8% after 50 years, with a maximum pressure of 1.26 atm. Consistent with previous modeling, the decay heat of the fuel is the main factor that influences the results. For undried fuel in pure helium, the hydrogen concentration ranges from 0.23 to 1.2% after 1 year, 1.25-6.2% after 10 years and 8.8 to 18.84% after 50 years. For dried fuel in pure helium the hydrogen concentration ranges from 0.06% to 0.34% after 1 year, 0.35-2.11% after 10 years and 0.95 to 6.6% after 50 years. While long-term results in the presence of residual air are mostly the same, early reactions with O 2 can delay significant production of H 2 until it is consumed to form more water vapor, lowering the range to 0.14 to 1.0% after 1 year. The maximum absolute pressure that is reached across any scenario is 2.06 atm. In the event of residual air, the presence of nitric acid is possible in the range of 18-131 ppm after 1 year, 174-1180 ppm after 10 years, and 586-3500 ppm after 50 years. As long as the fuel is sufficiently dried, or of nominal decay heat, a 4% lower flammability limit of hydrogen will not be reached within a 10-year monitoring period.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Life cycle assessment of utilizing freshly cut urban wood: A case study

Large amounts of urban wood resources are generated through tree removals in urban areas. Therefore, there is a growing interest to improve the environmental performance of the urban wood supply chain by quantifying the environmental impacts of creating high-value products from urban tree removals to enhance its utilization. By surveying existing urban wood utilization operations for primary data in two major cities: Baltimore, Maryland, and Milwaukee, Wisconsin, a new life cycle inventory (LCI) dataset per m 3 of dry urban hardwood lumber and live edge slabs was created. Incorporating the new LCI data into life cycle assessment method, the total global warming (GW) impact of converting urban trees to kiln-dried lumber was estimated to be 122 kg CO 2 eq and 336 kg CO 2 eq per m 3 of lumber produced for Baltimore and Milwaukee, respectively. In both cases, the total environmental impact of the product was dominated by the conversion of urban trees to kiln dried lumber at the sawmill processing stage. Using scenario analysis for the source of heat generation used in kiln (force) drying wood, substituting wood fuel from coproducts for natural gas in a boiler for Milwaukee resulted in a substantial reduction in fossil-derived GW impact. Urban and traditional hardwood lumber production follow similar GW impact trajectories over their life-cycle stages with the lumber processing stage having the highest environmental impacts for both. Finally, increasing the overall lumber yield and decreasing kiln (force) drying would substantially improve the environmental performance of urban hardwood lumber and help make it comparable to traditional lumber.

54 ENVIRONMENTAL SCIENCES↗

Contributions to regional precipitation change and its polar-amplified pattern under warming

Abstract The polar regions are predicted to experience the largest relative change in precipitation in response to increased greenhouse-gas concentrations, where a substantial absolute increase in precipitation coincides with small precipitation rates in the present-day climate. The reasons for this amplification, however, are still debated. Here, we use an atmospheric energy budget to decompose regional precipitation change from climate models under greenhouse-gas forcing into contributions from atmospheric radiative feedbacks, dry-static energy flux divergence changes, and surface sensible heat flux changes. The polar-amplified relative precipitation change is shown to be a consequence of the Planck feedback, which, when combined with larger polar warming, favors substantial atmospheric radiative cooling that balances increases in latent heat release from precipitation. Changes in the dry-static energy flux divergence contribute modestly to the polar-amplified pattern. Additional contributions to the polar-amplified response come, in the Arctic, from the cloud feedback and, in the Antarctic, from both the cloud and water vapor feedbacks. The primary contributor to the intermodel spread in the relative precipitation change in the polar region is also the Planck feedback, with the lapse rate feedback and dry-static energy flux divergence changes playing secondary roles. For all regions, there are strong covariances between radiative feedbacks and changes in the dry-static energy flux divergence that impact the intermodel spread. These results imply that constraining regional precipitation change, particularly in the polar regions, will require constraining not only individual feedbacks but also the covariances between radiative feedbacks and atmospheric energy transport.

Bonan, David B. (ORCID:0000000338676009)↗

Metal foam heat exchangers for air and gas cooling and heating applications

Improved heat exchangers according to several embodiments are provided. The heat exchangers provide improved heat transfer for air flow in wet and dry operating conditions, while minimizing pressure drop across the heat exchanger in some applications. According to one embodiment, an improved heat exchanger includes a plurality of metal foam fins between adjacent heat exchange conduits, the heat exchange conduits being arranged parallel to each other to define parallel flow paths between an inlet header and an outlet header. The metal foam fins occupy a cross-flow region between adjacent conduits, the fins having a fixed angular orientation or being rotatable in unison to vary the thermal capacitance of the heat exchanger.

Nawaz, Kashif↗

Impact of Dry Cooler Air-Side Performance on a sCO2 Power Cycle for a CSP Application

Uncertainty around the design and control of the supercritical CO2 power cycle must be reduced before this technology can be implemented for large-scale grid support. To better understand the day-to-day performance of an sCO2 cycle, off-design performance calculations must be included for all power block components, and performance assumptions must be removed. This study has expanded the modeled scope to include the air-side performance for the dry cooler and has incorporated discretized heat transfer calculations for both streams through the pre-cooler to better predict off-design performance. This study considered a recompression Brayton cycle in a concentrating solar power application. The cycle model utilized fixed sCO2 turbomachinery maps for the main compressor, recompressor, and expander operating to supply approximately 10 MW gross at the design point. Fixed vendor-supplied fan curves were used to calculate the air-side performance of the dry cooler. The primary heater was modeled considering both the sCO2 and heat transfer fluid streams. Off-design performance was predicted for an ambient temperature range of 0-55℃, a HTF temperature range of 705-735℃, and a HTF mass flow range of 50-105% of the design point value. To understand the importance of modeling the air-side performance, the cycle off-design performance was also calculated using a constant CO2 outlet temperature assumption and a constant approach temperature assumption for the dry cooler. Results show that using these assumptions can significantly alter the power output and cycle efficiency predictions.

14 SOLAR ENERGY↗

Extending the Heat Index

The Heat Index is a widely used measure of apparent temperature that accounts for the effects of humidity using Steadman’s model of human thermoregulation. Steadman’s model, however, gives unphysical results when the air is too hot and humid or too cold and dry, leading to an undefined Heat Index. For example, at a relative humidity of 80%, the Heat Index is only defined for temperatures in the range of 288-304 K (59-88 degrees Fahrenheit). Here, Steadman’s thermoregulation model is extended to define the Heat Index for all combinations of temperature and humidity, allowing for an assessment of Earth’s future habitability. The extended Heat Index can be mapped onto physiological responses of an idealized human, such as heat exhaustion, heat stroke, and even heat death, providing an indication of regional health outcomes for different degrees of global warming.

54 ENVIRONMENTAL SCIENCES↗

Cooling and dietary crude protein affected milk production on heat-stressed dairy cows

Environmental factors, such as temperature and humidity, exert dramatic effects on the production, health, and well-being of lactating dairy cows. Heat-stressed cows undergo a series of homeorhetic adaptations that alters cellular homeostasis and nutrient utilization. As such, the objective of this study was to determine the effects of cooling and dietary crude protein (CP) content on fermentability of rumen inoculum, milk production, and health of heat-stressed cows. It was hypothesized that cooled but not heat-stressed cows would support productivity in response to an increase in dietary CP content. Thirty-six multiparous Holstein cows were randomly assigned to 1 of 4 treatments in a 2 × 2 factorial arrangement (9 cows/treatment). Treatments consisted of cooling (CO) or moderate long-term heat stress (HS) and diets containing low CP content (LCP; 12.5% CP) or moderate CP content (MCP; 16.1% CP) of dry matter. The CO treatment provided heat abatement with sprinklers and fans that came on at > 20.0°C, whereas the HS treatment did not provide sprinklers and fans. Cows were housed in pens in a freestall barn, and treatments were imposed for 21 d during July and August. Compared with the HS treatment, CO decreased afternoon rectal and vaginal temperatures (0.60 and 0.70°C) and afternoon respiration rate (27.6 breaths/min). Treatment interactions showed that compared with the LCP treatment, MCP increased milk fat yield (23%) in CO but not in HS cows. Compared with the LCP treatment, MCP decreased milk protein percent (0.14 units) in CO but increased milk protein percent (0.09 units) in HS cows. Rumen inoculum collected on d 21 showed a ~3-fold increase in total gas production in vitro in CO compared with the HS treatment. Relative to the LCP treatment, MCP increased plasma glucose and insulin and decreased total free fatty acids concentrations. In summary, under the conditions of this study CO but not HS cows responded to a CP stimulus by increasing productivity.

59 BASIC BIOLOGICAL SCIENCES↗

What drives daily precipitation over the central Amazon? Differences observed between wet and dry seasons

This study offers an alternative presentation regarding how diurnal precipitation is modulated by convective events that developed over the central Amazon during the preceding nighttime period. We use data collected during the Observations and Modelling of the Green Ocean Amazon (GoAmazon 2014/2015) field campaign that took place from 1 January 2014 to 30 November 2015 in the central Amazon. Local surface-based observations of cloud occurrence, soil temperature, surface fluxes, and planetary boundary layer characteristics are coupled with satellite data to identify the physical mechanisms that control the diurnal rainfall in central Amazon during the wet and dry seasons. This is accomplished through evaluation of the atmospheric properties during the nocturnal periods preceding raining and non-raining events. Comparisons between these non-raining and raining transitions are presented for the wet (January to April) and dry (June to September) seasons. The results suggest that wet-season diurnal precipitation is modulated by nighttime cloud coverage and local influences such as heating induced turbulence, whereas the dry-season rain events are controlled by large-scale circulations.

54 ENVIRONMENTAL SCIENCES↗

Efficiency Limits of Evaporative Fabric Drying Methods

Cloth drying is a major consumer of energy, and most drying is conducted by evaporative methods. The evaporative drying energy efficiency limit is commonly assumed to be 100%: one unit of latent heat removed per unit of energy expended. However, this ignores the “free drying” available from unsaturated ambient air and the possible role of heat pumping. We demonstrate that efficiency limits for evaporative drying are fundamentally related to both drying rate and ambient psychrometric conditions. A relationship among efficiency, drying rate, and ambient conditions is quantified for several evaporative drying technologies, and a comparison among evaporative technologies is provided. In addition, a comparison is provided between efficiency limits and state of the art device performance. This research will help guide future research in the most promising directions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-scale and multi-physics analysis, design optimization, and experimental validation of heat exchangers utilizing high performance, non-round tubes

Air-to-refrigerant heat exchangers (HXs) are fundamental components in HVAC&R systems, and considerable research has been dedicated designing continually smaller, lighter, and more efficient HX designs. In recent years, researchers have leveraged advancements in Computational Fluid Dynamics (CFD), Finite Element Analysis (FEA), and optimization algorithms to consider primary tube shape and topology optimization to design highly compact, high performance HXs for a multitude of applications. In this research, we present a computationally efficient, comprehensive, multi-scale, and multi-physics analysis and optimization method for air-to-refrigerant HXs featuring automated CFD and FEA simulations and approximation-assisted optimization. This methodology was utilized to design HXs with shape-optimized, non-round tubes which outperform current state-of-the-art tube-fin HXs without compromising structural integrity. The optimal HXs were shown to deliver similar thermal performance to the baseline HXs while also achieving more than 20% reductions in airside pressure drop and core envelope volume and more than 30% reduction in internal volume. Comprehensive experimental validation of the optimization methodology was conducted through the testing of two prototypes in a standardized wind tunnel facility under multiple operating conditions. For prototype #1 under dry evaporator conditions, the predicted heat load agreed within ± 10% of measured values and the predicted airside pressure drop agreed within ± 30%, while for dehumidifying conditions, the predicted sensible and latent heat loads agreed within ± 10% and ± 20% of the measured values, respectively. For prototype #2, the predicted condenser heat load agreed within ± 3.0% of measured values, and the predicted airside pressure drop agreed within ± 27%. The acceptable agreement between simulation and experimental results for the present application highlights the flexibility of the novel optimization methodology to design next generation HXs with improved performance and reduced volume, weight, and environmental impact.

42 ENGINEERING↗

Integrated Radio Frequency and Ultrasonics with Conventional Processes for Efficient Water Removal in Pulp and Paper and Other Biomaterial Applications

Conventional drying processes used in the pulp and paper industry primarily involve lengthy, surface based, multi-cylinder conductive and convective drying with low thermal efficiencies and often use some fossil-based energy. Integration of cross cutting, electrically-powered, volumetric drying process intensification technologies based on Radio Frequency (RF) and acoustics (Ultrasonics) (US) will directly impart energy into the biomaterials resulting in improved energy efficiency and throughput. Integration of RFUS-based drying technology is expected to enable U.S. manufacturing industry to reduce capital and operating costs, energy consumption, and carbon emissions while increasing energy efficiency and throughput, improving product quality and sustainability, and helping preserve U.S. manufacturing jobs. The hybrid drying approach incorporates directed radio frequency (RF) and ultrasonic (US) energy with conventional conduction, diffusion and convective heat and mass transfer overcoming the limitations of the conventional drying processes and that meets/exceeds the minimum goals. We have shown the effective removal of free and bound water in the biomaterials by leveraging the synergies of RF and US technologies integrated with conventional manufacturing processes.

42 ENGINEERING↗

Synthesis of boron-carbide aerogels

We present the synthesis of boron carbide aerogels utilizing nano-boron powder and resorcinol–formaldehyde (RF) organic aerogels as precursors. Monolithic aerogels were fabricated from suspensions of boron nanoparticles and RF via an organic sol-gel process, enabling effective distribution of boron in the gel network. The resulting gels underwent supercritical drying, thermal reduction, and subsequent heat treatment to yield boron carbide aerogels with densities ranging from 37 to 55 mg/cm³. By tuning the boron-to-carbon ratio, heat treatment temperature, and dwell time, surface areas up to 53 m²/g were obtained. X-ray diffraction analysis confirmed the formation of the boron carbide phase and detected the presence of residual carbon within the structure.

Materials science↗

Dirty dishes or dirty laundry? Comparing two methods for quantifying American consumers' preferences for load management in a smart home

One challenge of transitioning to renewable energy is that household electricity use and renewable generation are often misaligned. Smart home energy management systems hold promise for shifting usage to match generation, but these systems need to be designed with the occupants’ preferences in mind. The purpose of the present research is to compare two approaches for collecting and modeling consumers’ load management preferences, both of which are amenable to use in a home energy management system. Specifically, we examine the performance of Simple Multi-Attribute Rating Technique Exploiting Ranks (SMARTER) and Analytic Hierarchy Process (AHP) in quantifying consumers’ preferences regarding air temperature (air conditioning and heating), water heating, dishwashing, clothes washing and drying, monetary costs, environmental impacts, and comfort/convenience. Two studies are presented: Study 1 examines the SMARTER approach, and Study 2 focuses on the AHP approach. In both studies, online surveys (N SMARTER = 956 and N AHP = 1023) were conducted to elicit preferences from participants across the United States. The preferences modeled by both approaches were validated based on (a) their ability to predict participants’ choices in a Discrete Choice Experiment and (b) their convergence with previous research on load-shifting behavior. The validation procedure suggests that the SMARTER approach is superior in modeling consumers’ preferences for load management. Overall, this research lays the groundwork for designing a smart home interface capable of collecting occupants’ preferences and using those preferences to deliver improved occupant comfort, lower operating costs, reduced environmental impact, and more significant demand response than exists today.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Climatic Impact‐Driver Framework for Assessment of Risk‐Relevant Climate Information

Abstract The climate science and applications communities need a broad and demand‐driven concept to assess physical climate conditions that are relevant for impacts on human and natural systems. Here, we augment the description of the “climatic impact‐driver” (CID) approach adopted in the Working Group I (WGI) contribution to the Intergovernmental Panel on Climate Change (IPCC) Sixth Assessment Report. CIDs are broadly defined as “physical climate system conditions (e.g., means, events, and extremes) that affect an element of society or ecosystems. Depending on system tolerance, CIDs and their changes can be detrimental, beneficial, neutral, or a mixture of each across interacting system elements and regions.” We give background information on the IPCC Report process that led to the development of the 7 CID types (heat and cold, wet and dry, wind, snow and ice, coastal, open ocean, and other) and 33 distinct CID categories, each of which may be evaluated using a variety of CID indices. This inventory of CIDs was co‐developed with WGII to provide a useful collaboration point between physical climate scientists and impacts/risk experts to assess the specific climatic phenomena driving sectoral responses and identify relevant CID indices within each sector. The CID Framework ensures that a comprehensive set of climatic conditions informs adaptation planning and risk management and may also help prioritize improvements in modeling sectoral dynamics that depend on climatic conditions. CIDs contribute to climate services by increasing coherence and neutrality when identifying and communicating relevant findings from physical climate research to risk assessment and planning activities.

54 ENVIRONMENTAL SCIENCES↗

Next Generation System Analysis Model: Recently Added Features and Future Plans

To better enable informed decision-making regarding the back-end of the nuclear fuel cycle, the Integrated Waste Management System (IWMS) program within the U.S. Department of Energy, Office of Nuclear Energy (DOE-NE) has been sponsoring the development and application of system analysis tools capable of analyzing various system options for the management of spent nuclear fuel (SNF) and high-level radioactive waste (HLW).With these tools, IWMS architecture analyses are being conducted to support the future deployment of a comprehensive nuclear waste management system that considers all major back-end aspects of the nuclear fuel cycle (i.e., transportation, storage, and disposal). The Next Generation System Analysis Model (NGSAM) is an agent-based simulation software tool expressly designed to be capable of modeling features within various IWMS architectures. NGSAM imports data from Oak Ridge National Laboratory (ORNL)’s unified database (e.g., historic assembly information, thermal profiles for assembly heat, and at-reactor dry storage loadings) to ensure that each simulation initializes with a realistic representation of the state of commercial SNF in the U.S. Recent major enhancements implemented into NGSAM in the period since NGSAM was last presented at the WM2019 conference include: • Tracking of railroad escort car acquisition and buffer car acquisition • The addition of heavy haul truck (HHT) and barge routes for some sites, as well as support for user-defined inter-modal routes • Updates to the logic that checks the transportation cask thermal limit maps prior to package transport • An allocation method that predicts when reactor sites would pack assemblies from their spent fuel pools for dry storage, and prioritizes shipments directly from the pools of those reactor sites in the preceding periods (before the predicted loadings to dry storage), thus reducing the number of casks loaded into dry storage at reactor sites • The addition of “reactor site family” operational limits to restrict the number of loads of SNF taken from the pool and from dry storage at a given reactor site each year • Added support for multiple canister loading map options and packages with multiple compatible transportation overpacks • Updates to the handling of non-commercial SNF, including a new database that contains data to support the updates • Updates to allow analysis of hypothetical scenarios which include repackaging at reactor sites, e.g., for possible comparative analysis with other scenarios • Implementation of additional output reports, or modification of existing ones • The ability to generate and implement user edits via the NGSAM website • The ability to model loading SNF from pool storage at an interim storage facility (ISF) into dry storage at the ISF • The ability to model consolidating SNF from different existing storage containers at a DOE site into the same DOE standard canister • The ability to model transferring SNF casks from one transportation mode to another, e.g., from HHT to rail, referred to as transloading. These new features have improved NGSAM capabilities and users’ experience with the model. Preliminary NGSAM requirements for modeling advanced reactor fuels, reprocessing, treatment, and conditioning were considered, and this paper describes them at a high level. Other nuclear fuel cycle system analysis tools developed under sponsorship of DOE-NE, like the VISION code developed at Idaho National Laboratory, might be better suited for initial high-level analysis of those technologies and advanced fuel cycles. As technologies are developed and system concepts evolve, NGSAM could provide value by providing more detailed modeling of transport, storage, and disposal of spent fuel and wastes from advanced reactors and advanced fuel cycles at the fuel element and waste container level.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Energy-efficient sorption-based gas clothes dryer systems

Standard electric resistance and fuel-driven dehydration technologies exhibit a maximum coefficient of performance of well below 1 mainly due to enthalpy losses associated with the air leaving the dehydration system. To improve energy efficiency, condensing dryer systems condense the moisture captured from a product in a closed-loop air circulation cycle. Existing condensing dehydration systems including heat pump dryers, however, need to significantly cool the air to achieve dehumidification. The added cooling and subsequent heating to return the air to a desired drying temperature consume substantial energy and thus reduce drying performance. Here, an innovative sorption-based gas dehydration system is proposed to overcome barriers deteriorating energy efficiency in existing gas, electric, or heat pump dryer systems. Decoupling latent and sensible loads, the system employs a liquid-desiccant solution to directly capture air humidity, thereby allowing circulation of the air in a closed loop to achieve high drying energy efficiency. In other words, the system captures waste latent heat from the moisture produced during the dehydration process and reuses it to improve energy efficiency. This study focuses on a comprehensive quasi-steady-state thermodynamic modeling of the proposed sorption-based dehydration concept employed for a gas clothes dryer application to predict transient response and overall drying performance (i.e., time and energy metrics). The analysis indicates the proposed sorption-based gas clothes dryer system can deliver a specific moisture extraction rate of 1.71 kg of water per kWh (i.e., a combined energy factor of 3.167 kg (6.98 lbm) of dry cloth per kWh) with a drying time of 44 min. This is a 112% energy improvement compared with state-of-the-art gas clothes dryers exhibiting a combined energy factor of 1.50 kg (3.3 lbm) of dry cloth per kWh. The technology pursued here can potentially be employed as a platform for many fuel-driven equipment to take advantage of available waste thermal energy in the environment instead of simply burning a fuel.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Validated model of a thermoelectric heat pump clothes dryer using secondary pumped loops

The energy associated with clothes drying makes up 4% of the total residential electrical energy consumption in the US. The cost is high since most clothes dryers use electric resistance heating which is inexpensive but also energy inefficient. State-of-the-art vapor-compression heat pump clothes dryers offer significant energy savings but have limited market penetration in the US. Here, a new configuration of clothes dryer was studied that utilizes a solid-state thermoelectric heat pump with pumped secondary water loops and conventional fin-and-tube water-to-air heat exchangers. Experimental results are presented for the thermoelectric dryer prototype with a combined energy factor of 6.89 lb BDW /kWh (specific moisture extraction rate of 1.71 kg w /kWh) and a dry time of 84 min for a standard load size of 8.45 lb (3.83 kg) with 57.5% starting moisture content. This is a 85% energy efficiency improvement over baseline electric resistance dryers. The efficiency and drying time results achieved are similar to vapor compression heat pump dryers. Compared to previous air-based thermoelectric clothes dryers, the energy efficiency has been increased by 6%, but drying time has been reduced by as much as 47% using secondary pumped loops and separate heat exchangers, which represents a significant advancement in the technology. In addition to the experimental prototype, a model was also developed to study the performance. The model was validated against experimental prototype data and used to identify the range of performance (dry time and efficiency) that could be expected of the design.

42 ENGINEERING↗