Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data Center Cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Organizational and psychological measures for data center energy efficiency: barriers and mitigation strategies

Abstract It was last estimated that in 2020, data centers comprised approximately 2% of total US electricity consumption, with an estimated annual growth rate of 4%. As our country increasingly relies on information technology (IT), our data centers (DCs) will need to increase their energy efficiency (EE) to stabilize their energy consumption. The task of studying EE in DCs is complicated by the interconnected nature of humans and mission-critical technical systems. Moreover, the literature tends to focus on technology solutions such as improvements to IT equipment, cooling infrastructure, and software, without addressing organizational and psychological drivers. Our research demystifies the complex interactions between humans and DCs, by asking What non-technical barriers impede EE investment decision-making and/or implementing energy management strategies? To begin to answer this question, we perform a literature review of 86 resources, ranging from peer-reviewed journal publications to handbooks. We also consider related fields such as organizational behavioral management and energy intensive buildings. We develop a public Zotero library, perform content coding, and complete a rudimentary network analysis. Our findings from the literature review suggest that (1) technological solutions are abundant in the literature but fall short of providing practical guidance on the pitfalls of implementation, (2) making energy efficiency a priority at the executive level of organizations will be largely ineffective if the IT and facilities staff are not directly incentivized to increase EE, and (3) there is minimal current understanding of how the individual psychologies of IT and facilities staff affect EE implementation in DCs. In the next phase of our research, we plan to interview data center operators/experts to ground-truth our literature findings and collaboratively design decarbonization policy solutions that target organizational structure, empower individual staff, and foster a supportive external market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Capillary-Enhanced Two-Phase Micro-Cooler Using Copper-Inverse-Opal Wick with Silicon Microchannel Manifold for High-Heat-Flux Cooling Application

In this work, we demonstrate a two-phase capillary-fed boiling micro-cooler that consists of a ~ 25-..mu..m-thick copper inverse opal (CIO) porous wicking structure for high-heat-flux boiling and a silicon 3D-manifold for distributed liquid delivery and vapor extraction across a 0.5 cm x 0.5 cm heated area. At low inlet water mass flow rates of 1.5 to 1.9 g(min)-1, the micro-cooler displays nearly two-phase boiling with exit vapor quality ~ 1 and a high critical heat flux (CHF) of 253 to 320 W cm-2 with low superheat of ~ 10 degrees C resulting in a thermal resistance of boiling ~ 0.025 cm2 degrees C W-1 or heat transfer coefficient of 0.4 MW m-2 degrees C-1. For higher flow rates of 5, 10, and 15 g(min)-1, the micro-cooler exhibits a hybrid single-phase and two-phase cooling regime where the contribution of the sensible heat (single-phase) cooling is linearly added to that of the two-phase cooling. For the highest flow rate of 15 g(min)-1, the CHF is increased to ~ 500 W cm-2 resulting in an overall thermal resistance of ~ 0.18 cm2 degrees C W-1. However, the two-phase heat transfer effectiveness, which estimates the utilization level of the inlet mass flow rate for two-phase boiling, is reduced to ~ 0.11. To achieve the best cooling system performances, the micro-cooler must operate entirely within the two-phase boiling regime (exit vapor quality or two-phase heat transfer effectiveness ~ 1). Ideally, the "coolant" should be delivered near its saturation temperature (~ 100 degrees C for water), which provides significant advantages for the energy-efficient operation of data centers and power electronics. We present detailed analysis with Infrared and high speed camera images at various inlet flow rates and heat fluxes to understand complex heat transfer in the micro-cooler. Furthermore, a conjugate thermofluidic simulation model, which incorporates the physics of capillary-fed boiling in a porous copper layer, agrees well with the experimental data.

capillary-enhanced boiling↗

Opportunities for Using the Industrial Assessment Center Database for Industrial Water Use Analysis

The manufacturing sector accounted for approximately 5–6% of total U.S. water use in 2015. Of that amount, 75–80% is self supplied withdrawal from surface-water and groundwater sources and the remainder is from public water supplies. Although manufacturing facilities commonly locate in water-scarce areas, water scarcity still poses a great risk to the manufacturing sector. Reliable water is necessary for any facility that relies on it for process and comfort cooling, cleaning, employee use, and steam generation. One of these barriers to water efficiency is the lack of reliable data on overall U.S. industrial water use—how it is used and the quantities required for each sector. If a facility cannot be easily compared with a facility of similar size and sector, knowing if it is effectively using water conservation best practices is difficult. One potential source of industrial water use data is the U.S. Department of Energy (DOE)–sponsored Industrial Assessment Centers (IACs). IACs are university-based organizations that provide free audits to small- and medium-sized manufacturing facilities to identify productivity improvement and waste and energy reduction opportunities. The IACs also maintain a database of all the audits conducted, which currently holds more than 19,267 assessments and 145,000 recommendations (as of July 24, 2020). This database also contains energy utility (electricity, natural gas, and other fuels) and water utility data, making it a potential data source for industrial water use. This report attempts to create regression models to predict a small- or medium-sized industrial facility’s annual water use or cost based on its industrial subsector and several possible relevant variables. Using data collected by IAC assessments, models for several industrial subsectors were generated via stepwise regression techniques to determine which variables (annual sales, number of employees, facility/plant area, annual production hours, and a water stress metric) are relevant.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Physics-Informed Reinforcement Learning Framework for Economic-Thermal Co-Optimization of Crypto Mining Data Centers: Preprint

The rapid expansion of cryptocurrency mining has created a new class of high-density data centers characterized by extreme thermal flux and high sensitivity to volatile economic markets. Traditional thermal management strategies, typically reliant on rule-based control, maintain static setpoints that fail to account for fluctuating electricity prices and cryptocurrency values - factors critical to mining profitability. To address this, we present a physics-informed reinforcement learning (PIRL) framework for economic-thermal co-optimization in crypto mining data centers. This framework consists of a proximal policy optimization (PPO) agent, a virtual testbed powered by high-fidelity physics-based models, and an interactive frontend dashboard. The PPO agent is trained using the virtual testbed and strict hardware safety limits. This physics-informed approach allows the agent to learn a stochastic policy that dynamically balances mining revenue against operational costs by co-optimizing HVAC cooling setpoints and IT computational hashrate. The simulation results demonstrate that the integrated framework achieved an 8.62% increase in net operational profit compared to traditional baseline strategies while strictly adhering to safety-critical temperature constraints (coolant supply temperature < 32 degrees C). This work provides a scalable template for the deployment of reinforcement learning in mission critical facilities where economic volatility and physical safety must be managed simultaneously.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Synergistic Pathways for Water Security in Emerging Sectors: Data Centers and Modern Nuclear Facilities

Stand-alone data centers, nuclear-powered data centers, and novel nuclear facilities such as fusion plant and small modular reactors (SMRs) are rapidly expanding, water-intensive sectors that present a significant challenge to the water-for-energy nexus. Their large-scale consumption of water for cooling systems not only reduces downstream water quantity but also degrades quality, demanding an integrated approach by stakeholders to understand and address these impacts through infrastructure planning and development.

42 ENGINEERING↗

Grounding our Understanding of the Impacts of Boreal Forest Expansion on Shallow Cumulus Clouds with a Simple Modeling Framework

Abstract The expansion of the boreal forest poleward is a potentially important driver of feedbacks between the land surface and Arctic climate. A growing body of work has highlighted the importance of differences in evaporative resistance between different possible future Arctic land covers, which in turn alters humidity and cloudiness in the boundary layer, for these feedbacks. While thus far this problem has been studied primarily with complex Earth system models, we turn to a locally focused, idealized model capable of diagnosing and testing the sensitivity of first-order processes connecting vegetation, the atmospheric boundary layer, and low clouds in this critical region. This allows us to benchmark the mechanisms and results at the center of predictions from larger-scale simulations. A surface dominated by broadleaf trees, characterized by higher albedo and lower surface evaporative resistance, drives cooling and moistening of the boundary layer relative to a surface of needleleaf trees, characterized by lower albedo and higher surface evaporative resistance. Differences in evaporative resistance between these hypothetical Arctic vegetation covers are of equal importance to changes in albedo for the initial response of the boundary layer to boreal expansion, even with our idealized approach. However, compensation between the elevation of the lifting condensation level (LCL) and more rapid growth of the mixed layer over higher evaporative resistance surfaces can minimize changes in the favorability of shallow clouds over different land cover types under some conditions. We then perform two tests on the sensitivity of this compensating effect, to changes in water availability, represented first by a reduction in boundary layer humidity and then by both a reduction in humidity and soil moisture available to our vegetation surface. Finally, given the importance of this potential LCL–mixed-layer height compensation in our idealized modeling results, we look to determine its relevance in observational data from a field campaign in boreal Finland. These observations do confirm that such a coupling plays an important role in cumulus-topped boundary layers over a needleleaf forest surface. While our results confirm some underlying mechanisms at the center of prior work with Earth system models, they also provide motivation for future work to constrain the impact of boreal forest expansion. This will include both large eddy simulations to examine the impact of processes and feedbacks not resolved by a mixed-layer model, as well as a more systematic evaluation and comparison of relevant observations at the site in Finland and sites from prior boreal field campaigns. Significance Statement Clouds and vegetation are both important components of the climate system that interact across a range of scales. These interactions are central to understanding how changes at the land surface feedback on climate. For example, if a forest expands or recedes, diagnosing how that will impact clouds will determine whether you predict warming or cooling temperatures from that shift in the forest area. These predictions are often made with complex Earth system models, but we look to a more idealized representation of the land–atmosphere system to diagnose how shallow clouds should respond to changes in surface properties with different scenarios of boreal forest expansion at a more foundational level. This both grounds our understanding of previous analysis and provides helpful direction for future studies of this relevant and impactful land cover change.

Meteorology & Atmospheric Sciences↗

Providing Experimental Infrastructure for Accelerating Advanced Reactor Demonstrations through the National Reactor Innovation Center

A suite of experimental infrastructure projects has been developed by the National Reactor Innovation Center to accelerate advanced reactor demonstrations and facilitate their development, addressing crucial gaps in data, materials characterization, and modeling. First, the Molten Salt Thermophysical Examination Capability (MSTEC) provides a specialized platform for post-irradiation characterization of molten salt reactor fuel, coolant salts, and structural materials, essential for supporting the design and operation of advanced reactors and future commercial molten salt reactor development and licensing. The Virtual Test Bed (VTB) complements these efforts by leveraging advanced modeling and simulation tools to evaluate reactor performance and safety. Serving as a library of reference models, the VTB offers a database of multiphysics reactor models, facilitating rapid safety evaluations and includes continuous software quality assurance, crucial for accelerating deployment while maintaining reliability. Additionally, the Helium Component Test Facility (HeCTF) addresses the need for high-temperature helium-cooled reactor component testing. As the first-of-its-kind facility in the United States, HeCTF emulates high-temperature gas reactor conditions, reducing time and cost associated with component validation, thereby accelerating reactor development. Finally, In-cell Thermal Creep Frames provide a unique solution for obtaining thermal creep data from irradiated materials, critical for materials qualification and licensing. Developed by the National Reactor Innovation Center, these compact frames enable the examination of previously irradiated materials, overcoming traditional limitations and enhancing the understanding of mechanical properties crucial for reactor development. Collectively, these experimental infrastructure projects form a comprehensive framework aimed at expediting advanced reactor demonstrations, fostering innovation, and ensuring the viability of next-generation nuclear energy solutions.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Determining the effects of U/Pu ratio on subsolidus phase transitions in U-Pu-Zr metallic fuel alloys

Here, ternary alloys consisting primarily of uranium, plutonium, and zirconium (U-Pu-Zr) are among the leading candidate fuel systems considered for fast spectrum nuclear reactors. Despite historical operation data from the testing of U-Pu-Zr rods in the Experimental Breeder Reactor-II, considerable uncertainty about the evolution of phases and microstructure across the ternary composition space exists. Due to sluggish kinetics and other difficulties in handling metal actinide specimens, quantitative measurements of phase-transitions in U-Pu-Zr alloys remain sparse in scientific literature, with most investigators reporting either phase-transition temperatures or phase identification data, but not both from the same specimens. The purpose of this paper is to critically compare experimental and calculated phase transition data and correlate with the microstructure and phase characterization data of as-cast and annealed U-Pu-Zr alloys. Phase transition peaks were measured using differential scanning calorimetry in the subsolidus regions (723-948 K) of three ternary U-Pu-Zr alloys with the same zirconium concentration but various U/Pu ratios. Overlapping peaks were deconvoluted using a Frazier-Suzuki peak fitting algorithm, and the critical peak temperatures and enthalpies were calculated. In general, increasing concentrations of Pu were associated with enhanced thermal stability of the body-centered cubic γ phase upon both heating and cooling. Experimental phase transition temperatures in this study tended to agree well with the predictions of the established ternary phase diagrams and other reported phase transition temperatures in literature. Additionally, the TAF-ID thermodynamic database was used to calculate a U-Pu-40 at.% Zr pseudobinary diagram as well as ternary diagrams from 773 to 973 K. The equilibrium phase transition temperatures tended to be considerably lower than measured peak temperatures upon both heating and cooling. Recommendations for improving the quality of data in future U-Pu-Zr characterization studies are also discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AmeriFlux US-UR8 Yellow Jacket - UCRB

This is the AmeriFlux version of the carbon flux data for the site US-UR8 Yellow Jacket - UCRB. Site Description - This site is located in Yellow Jacket, Colorado, on a moderate slope. The area is irrigated using a center pivot system, with alfalfa being the dominant vegetation. The region experiences a temperate climate, characterized by cool to mild temperatures throughout the year and substantial annual precipitation, creating favorable conditions for agricultural activities.

Neale, C. U. [Daugherty Water for Food Global Inst↗

Data Report on Post-Irradiation Dimensional Change of AGC-1 Samples

This report documents the measured post irradiation dimensional change in the AGC-1 samples. The AGC-1 capsule is the first in six planned irradiation capsules comprising the Advanced Graphite Creep (AGC) test series. AGC-1 irradiation began September 5, 2009 in the Advanced Test Reactor (ATR) and was completed on January 8, 2011. The capsule was cooled for 3 months in the ATR Canal, and then shipped to MFC in April 2011 for disassembly and sample extraction. After extraction the samples were shipped to the INL Research Center (IRC) for initial post-irradiation examination (PIE) and storage in the irradiated graphite vault. The AGC-1 capsule design contained “matched pair” samples to ascertain the irradiation-induced dimensional changes and levels of creep experienced in different graphite types. The irradiation-induced dimensional changes and creep levels are determined by comparing the total dimensional change for stressed and unstressed samples of the same type of graphite exposed to the same dose levels and at similar temperatures. Under irradiation creep (i.e. permanent strain due to irradiation, stress, and temperature) the stressed samples should demonstrate more dimensional change than the unstressed samples. This additional dimensional change in the stressed samples is designated as “irradiation-induced creep” in graphite. The data are further presented using the parameters influencing dimensional change in graphite; levels of induced stress, temperature, graphite type, and dose. However, the AGC-1 post-irradiation examination is a significant endeavor and this data report serves to provide irradiation-induced dimensional change data for AGC capsule design refinement as well as a status on the progress of the PIE activities. The dimensional changes of both the samples and graphite body are very important to the design of the future AGC capsules (AGC-3 through AGC-6) and are provided as soon as the data are available in order to determine whether design changes to the next capsule are required. A complete evaluation of the irradiation-induced dimensional change data will be performed for a final AGC-1 PIE report that will include full analysis of pre- and post-irradiation data, with verified AGC-1 irradiation conditions of temperature and dose.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Psychrometric Chart v1.0.0

Psychart is a graphical program developed for NERSC for accurately monitoring air conditions for the air cooled HPC equipment. Psychart will live directly in the OMNI system as a Grafana plugin. It employs the use of Psychrolib and the Grafana Starter Panel to create a front-end program that plots the state of the environmental air on a psychrometric chart. It is highly customizable, allowing the user to modify graph bounds, optionally show ASHRAE data center comfort regions, change the series point color, and more. What sets Psychart apart from other existing psychrometric charts is its ability to plot in real-time. Other psychrometric charts that can be found online require manual input of data and do not seamlessly integrate with Grafana.

Ventura, Nicolas↗

High precision magnetic field measurement and mapping of the LEReC 180 degree bending magnet using very low field NMR with hall combined probe (140 - 350 gauss)

The Relativistic Heavy Ion Collider (RHIC) at BNL are using the Low Energy RHIC Electron Cooling (LEReC) to conduct experiments that search for the quantum chromodynamic (QCD) critical point. The first ever electron cooling based on the RF acceleration of electron beams was experimentally demonstrated on April 5, 2019 at LEReC at BNL. The first critical step in obtaining successful 3D non-magnetized cooling of the Au ion bunches in the RHIC cooling section was matching the electron beam energy with a relative error less than 5*10 -4 to the ion beam energy. Part of the LEReC beamline is a dipole magnet that bends the electron beam 180 degree. One of the most outstanding measurement challenges is that the dipole field is so low (≈200 G). Most of the existing NMR probes can only measure fields >400 G. Lower signal-to-noise ratio at low fields is requires the use of larger sample volumes. Working with CAYLAR, a NMR probe has been redesigned and optimized for these low field measurements with high resolution. We report the methods, challenges, and results for extensive magnetic field mappings of the 180 dipole magnet. A combination of NMR and Hall sensors has been successfully implemented to measure uniform field regimes inside the magnet center area and non-uniform field regimes at the magnet ends. Detailed measurement and mapping have been performed at five radii and five heights along the beam trajectory. Meanwhile a finite element magnetic modeling simulation of the magnet using Opera software has been performed. The calculated and measured data are compared, and the calculated data is good reference for measured data over long length mapping from magnet edge to center. The measured magnetic measurement data is directly useful for beam instrumentation, diagnostics and operation.

Magnetic Field Measurement↗

Futureproofing through 2035 for the AI and HPC Power Density Trend

HPC and AI are businesses necessitating growth for providing performance improvement with increased power and cooling. As HPC and AI computers and their supporting facilities approach utility scale with a frequency of technology innovation outpacing utility and construction timelines, understanding and designing for this trend has become critical. This paper will provide historical trend data for facilities and compute racks, relate power trend data to cooling technology capabilities, and reason through constraints impacting anticipated future power densities to aid the reader in futureproofing a facility’s power and cooling systems through the mid-2030’s.

97 MATHEMATICS AND COMPUTING↗

Mechanisms Behind the Long‐Distance Diurnal Offshore Precipitation Propagation in Northwestern South America

Abstract Northwestern South America (NWSA) is the rainiest region on Earth, with diurnal precipitation exhibiting extensive westward offshore propagation of up to about 1,200 km in boreal spring (March‐May). The diurnal offshore precipitation propagation begins slowly (3–10 m s −1 ) near the coast of NWSA (<200 km) but accelerates significantly (∼20 m s −1 ) and shows an afternoon enhancement far from the coast (>400 km). However, the driving mechanisms behind this long‐distance precipitation propagation remain unclear. Using a new cloud tracking and classification data set, we found that mesoscale convective systems (MCSs) are the dominant precipitation contributors in the offshore region of NWSA. Cloud tracking shows that the long‐distance propagation and the afternoon enhancement of diurnal precipitation primarily originate from MCSs initiated in the early morning, either over open oceans or from the coast of Central America. Composite tendency analysis shows that MCSs initiated near the coast of Central America have significant upward cooling and moistening signals starting from the surface before initiation. Further analysis of surface diurnal perturbation fields indicates that the land breeze is the primary driving mechanism for MCS initiation. Conversely, for MCSs initiated over open oceans, a significant downward cooling signal from 400 hPa is observed ∼7 hr before initiation, corresponding to the passage of diurnal gravity waves emitted from the Andes. Additionally, our findings highlight the critical role of lower and mid‐level moisture conditions in MCS initiation, alongside the influence of gravity waves.

Hu, Jingyi [Department of Meteorology and Atmosphe↗

Spatially resolved phase transformation mapping in 410 stainless steel during additive manufacturing visualized via real-time infrared data

Here, in this study, we demonstrate that spatially resolved cooling curves derived from real-time infrared (IR) thermography during additive manufacturing (AM) can capture spatial variations in phase transformation temperatures through cooling curve analysis (CCA). Using this approach, we show that during laser hot-wire deposition of 410 stainless steel (410SS), the martensite start temperature (M s ) evolves dynamically throughout the build. The M s temperature is spatially nonuniform, ranging from 185 °C to 348 °C, with the lowest values toward the build center and higher values toward the upper region of the deposit. In the lower portion of the build, no M s inflection is detected via CCA, consistent with transformation occurring earlier during thermal cycling followed by tempering during subsequent thermal cycles. These trends in M s are corroborated by characterizing the microstructure by electron backscatter diffraction (EBSD). Traditionally, M s is assumed to be constant, and a single interpass temperature is applied during both deposition and residual stress modeling. Our results demonstrate that IR-derived cooling curves provide a route to spatially and temporally resolved transformation temperature tracking for dynamic interpass control and improved residual-stress modeling.

Additive manufacturing↗

Low-Temperature Geothermal Play Fairway Analysis for the Denver Basin: Preprint

This project is part of a national initiative to showcase the benefits of incorporating low-temperature geothermal resource assessment into the deployment of geothermal heating and cooling (GHC), combined heat and power (CHP), and geothermal direct use (GDU) technologies. The initiative was established to accelerate the country's decarbonization efforts by identifying potential for low-temperature geothermal resource utilization (< 150 Degrees Celsius, i.e., GHC, CHP, and GDU) in selected sedimentary basins with numerous population centers. The Play Fairway Analysis (PFA) methodologies in this study were adapted from previous PFA investigations of sedimentary basin geothermal play types (SBGPTs) that evaluated the potential for low-temperature resources (< 150 Degrees Celsius). Workflows, relevant datasets, python code, common and composite geological criteria maps are utilized to develop low-temperature geothermal resource favorability maps for the Denver Basin, a sedimentary basin spanning Colorado, Nebraska, and Wyoming. The replication of these methodologies in other SBGPTs can evaluate potential for low-temperature resources. To facilitate future assessment of low-temperature geothermal resources in SBGPTs, this project provides PFA workflows, data, tools, and favorability maps that will ultimately support the utilization of low-temperature geothermal resources in sedimentary basins.

Denver Basin↗

AmeriFlux FLUXNET-1F US-Lin Lindcove Orange Orchard

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-Lin Lindcove Orange Orchard. This is the FLUXNET version of the carbon flux data for the site US-Lin Lindcove Orange Orchard produced by applying the standard ONEFlux (1F) software. Site Description - The experimental site was a citrus orchard about three km west of the UC Lindcove Research and Experiment Station. The site is characterized by a Mediterranean climate typical of Central California, with warm dry summers and cool wet winters. The soil texture for the upper horizon (0-33 cm) was loam with a particle size distribution of 42% sand, 38% silt, and 20% clay (Kearney Ag Center). Soil pH was 7.4 (Valley Tech Soil Agricultural Laboratory Services). The orchard was drip-irrigated with water applied twice per week in the warm season to ensure water avail- ability close to field capacity. The site was kept clean from understory vegetation and mechanical pruning operations took place twice a year to limit the size ofthe orange trees for harvesting and site maintenance. The block of trees in which the tower and instruments were located was ‘Valencia’ orange on trifoliate rootstock, with a planting date in the 1960’s. The square 4 ha block had dimensions of 200 m NeS and EeW. At the end of the study, we harvested a ‘Valencia’ citrus tree from within the study block to measure citrus leaf area index (LAI) and biomass density. The tree height was 3.7 m as measured with a telescoping pole. We measured canopy radii in the four cardinal directions to calculate a planar area (as seen from above) of 12.2 m2. The mean specific leaf area (SLA) of citrus leaves was 85.4 cm2 g-1 obtained by measuring leaf area of five groups of leaf samples with a LiCor Leaf area meter (mod. LI-3100C) followed by drying and weighing. LAI for the orchard was 3.00, derived using the SLA value and the total dry mass of leaves from the harvested tree, multiplied by the plant population of 237 plants per ha as obtained from spacing measurements and Google Maps imagery.

Fares, Silvano↗

University of Hawai‘i, Shallow Geothermal Resources: Energy Technology Innovation Partnership Project (Final Report)

Scientists at Lawrence Berkeley National Laboratory (Berkeley Lab) have teamed up with the University of Hawai‘i at Manoa (UH Manoa) through the U.S. Department of Energy’s Energy Technology Innovation Partnership Project to evaluate the technological and market feasibility of shallow geothermal heat exchanger (GHE) technology. UH requested this analysis to evaluate opportunities in building cooling, energy efficiency, and emissions reduction applications in Hawai‘i. UH has an abundance of geologic and geothermal data and is looking to the national labs’ expertise to execute this analysis. UH is also interested in investigating policy, regulatory, and business conditions advantageous for implementation of a pilot project and more broad deployment of this technology in Hawai‘i. In many locations around the world, the demands for heating and cooling are roughly balanced over the course of the year, so GHEs do not cause significant long-term changes in subsurface temperature. This is not the case in Hawai’i, where the demand for heating is very small, meaning that, over time, GHEs will add heat to the subsurface. If temperatures increase significantly, GHE systems will not work as designed. Regional groundwater flow has the potential to sweep heated water away from boreholes, thereby maintaining the functionality of the GHE system. Significant regional groundwater flow requires two things: a sufficiently large driving hydraulic head gradient (usually closely related to surface topography), and sufficient porosity and permeability to enable groundwater to flow in large enough quantities to enable near-borehole temperatures to be maintained at ambient values. Hawai‘i’s volcanic terrain offers ample surface topographic variation. The lava itself shows an extremely large range of porosity and permeability, so sites with large enough values of these properties must be selected. Numerical modeling of coupled groundwater and heat flow can be used to determine how large is large enough. Primarily, closed-loop systems have been investigated. Other options considered are open-loop systems and using cool seawater as the chilling source. Project work investigated the feasibility of GHE technology at two scales. At the island scale, GIS layers of various attributes relevant for GHE were combined to develop an overall favorability map for employing GHE in Hawai‘i. At the local scale, a hydrogeologic model for the subsurface component of a closed-loop system was developed for the Stan Sheriff Center at the UH Manoa campus. This site is considered promising because the rock below and immediately downgradient of the borefield is highly permeable, consisting of a subsurface karst system (limestone containing high-permeability open channels), which is underlain by a thick, high-permeability fractured basalt. Moreover, the site is near the base of the Ko‘olau Range, providing a large hydraulic head gradient. Thus, groundwater flow through the site is expected to be large, enabling efficient removal of heated groundwater. A full-GHE-system model of the site was also developed, with a simplified representation of the subsurface, in which groundwater flow is not considered and heat transfer is purely by conduction. Using the building cooling load data provided by UH, simulation results show that with groundwater flow present, a GHE can operate successfully for at least 10 years, but with no groundwater flow, the subsurface begins to heat up after only one year of operation, making the GHE unviable within 2-6 years. The team also developed a techno-economic model for this site to compare the cost of cooling using a GHE system with the costs of operating the current air-conditioning system. The GHE system is advantageous economically if favorable tax incentives and interest rates can be obtained.

15 GEOTHERMAL ENERGY↗