Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dehumidification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Performance study of the cross-flow Maisotsenko cycle in humid climate conditions

This paper presents a first numerical analysis of the cross-flow Maisotsenko cycle (M-Cycle) below dew-point evaporative cooler for humid climates with model including the water vapor condensation phenomenon. Proposed solution allows to cool ambient air below its dew-point temperature, by utilizing cooling energy in air extracted from the building, due to that it can be used as effective pre-cooling solution for traditional systems. Proposed unit has significant advantage over traditional counter and cross-flow units operating in heat recovery mode, hence it is almost insensitive on temperature of exhaust air. This is caused by effective pre-cooling of the exhaust air in its initial part. Operation in humid climates using cold extracted air results in condensation occurrence in the primary air channels, and hence partial dehumidification of the primary airflow (which allows to cool the air before its dew- point temperature). The Maisotsenko cycle exchanger used to recover heat in the air-conditioning system is compared with Maisotsenko exchanger that operates only on the ambient airflow and does not allow to recover heat from the exhaust airflow from a conditioned space. Achieved results showed that M-Cycle below dew-point air cooler can operate more effectively in humid climates than traditional cross-flow Maisotsenko cycle exchanger.

Condensation↗

Material properties of aqueous potassium acetate solutions for use in liquid desiccant air conditioning

We present thermophysical properties of aqueous potassium acetate solutions relevant to their application as a liquid desiccant in air-conditioning systems. Liquid desiccant air conditioners could provide up to 80% energy savings compared to high-efficiency vapor compression air conditioners. However, the commonly used liquid desiccants, particularly chloride salt solutions, are highly corrosive. This precludes the use of metallic components, necessitating specialized plastics and thereby driving up cost, weight, and limiting operational temperature and pressure ranges. Potassium acetate has been identified as a less corrosive alternative, potentially enabling broader material compatibility in LDAC components. In this study we systematically measured and modelled key thermophysical properties of KAc solutions density, vapor pressure, viscosity, specific heat capacity, phase behavior, and diffusion coefficient across a range of concentrations (10 - 70wt%) and temperatures. For instance, KAc exhibits a vapor pressure of 3.1 kPa at 50wt% and 40degrees C, demonstrating dehumidification capability comparable to chloride salts. By providing an extended dataset and associated models, this work advances the understanding needed to design energy-efficient, corrosion mitigating LDAC system.

36 MATERIALS SCIENCE↗

Additively manufactured multiplexed inertial coalescence filters

Multiphase flows often pose a significant challenge to the efficient and reliable design of thermofluidic systems. This paper describes multiplexed inertial coalescence filters composed of parallel helical pathways, designed to capture fine droplets (<40 µm) through inertial separation while maintaining a low pressure drop (<400 Pa). Filtration efficiencies for 7 µm and 30 µm droplets were characterized for varying flow conditions, with complete capture observed above a threshold flow rate. Models for filtration efficiency and pressure drop were developed and validated against experimental results to allow system design and optimization, enabled by the tunable additive manufacturing approach used to fabricate the filters. Filter quality factor was computed for varying droplet sizes, showcasing exceptional quality factor when compared to state-of-the-art filters documented in the literature. In conclusion, this multiplexed inertial coalescence filtration approach could find use in dehumidification systems, fog harvesting, chemical reactors, and microgravity droplet capture.

3D Printing↗

Elucidating the Microscale Behavior and Phase Separation Kinetics of Thermally Responsive Ionic Liquid–Water Mixtures

Thermally responsive ionic liquids (ILs) exhibit liquid-liquid phase separation into a water-rich (WR) and ionic-liquid-rich (ILR) phase when heated above a lower critical solution temperature (LCST). This phase behavior has been leveraged for applications ranging from forward osmosis (FO) desalination, where the IL acts as a draw solute, to refrigeration and dehumidification cycles, where the IL acts as a liquid desiccant. While significant effort has been devoted to characterizing the thermodynamic and thermophysical properties of LCST ILs, their phase separation kinetics have not been investigated. In this work, we describe the macroscale phase separation kinetics (phase separation time) by gleaning insight into the microscale colloidal behavior of aqueous mixtures of four different materials, P 4444 TFA (tetrabutylphosphonium-2,4-trifluoroacetate), P 4444 DMBS (tetrabutylphosphonium-2,4-dimethyl-benzenesulfonate), N 4444 Sal (tetrabutylammonium salicylate), and P 4444 Sal (tetrabutylphosphonium salicylate) as a function of IL concentration at a separation temperature of 70 °C. We report the discontinuous microscale size distributions for each material and correlate their theoretical settling velocities to experimental phase separation times. The results indicate that a simple Stokes' law model can predict the phase separation time within reasonable accuracy. Overall, this work lays the foundation for understanding the micro- to macroscale phase separation behavior and kinetics of LCST ILs for various water-energy applications.

LCST↗

Improving AHU Performance by Minimizing Approach Temperature, Reducing Air Maldistribution, and Efficiently Handling Sensible and Latent Loads (Phase 1 Interim Final Technical Report)

Residential air handling units (AHUs) have stayed the same in form and efficiency for the past 30+ years, with incremental improvements made to address safety, functionality, and energy-efficiency. The purpose of this research in Phase I, Topic 9a: Next Generation Residential Air Handlers, was to improve AHU performance by minimizing heat exchanger (HX) approach temperature, reducing air maldistribution, and developing alternative system configurations which more efficiently handle sensible and latent loads. In this research Optimized Thermal Systems (OTS) developed, modeled, and evaluated multiple alternative system concepts. A dual vapor compression system separate sensible and latent cooling (SSLC) concept was studied to inform work on alternative concepts and to show best-case performance benefit. System concepts included ejector enhanced vapor compression cycles, desiccant assisted dehumidification, dual evaporator SSLC, and alternative AHU HX configurations. A dual vapor compression system showed COP improvement of 20%, however, required additional components, increased unit size, and increased cost. Two types of ejector enhanced vapor compression cycles with dual evaporators improved system COP by 9 to 11%, and reduced AHU losses by as much as 18%, with design changes limited to the AHU, no unit physical size increase, and a moderate increase to system first cost. Desiccant assisted air-conditioning required increased air flow rate resulting in higher fan power and the desiccant wheel increased sensible heat load leading to increased compressor power and reduced system COP. Dual evaporator cycles were found to degrade performance due to increased expansion losses. Optimized single slab HX designs used in place of the traditional A-coil HX led to 44–49% reduction in aluminum, 47–60% less refrigerant charge, and improved HX velocity distribution.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mobile Sorption-based Thermal Battery for Harvesting Low-Temperature Geothermal Energy

Around 20% of the total primary energy in the United States is consumed for thermal demands of buildings such as space cooling, dehumidification, and space heating (EIA 2018). Low-temperature geothermal energy is abundant and can effectively satisfy buildings’ thermal demands. However, low-temperature geothermal energy is underutilized because the energy density of geothermal fluid is too low to justify the costs associated with transporting it between existing geothermal resources and buildings. The mobile sorption-based thermal battery (MSTB) system has been developed using three-phase (i.e., vapor–liquid, solution–solid, crystal) sorption technology to harvest low-temperature heat and store it with a much higher energy density than the geothermal fluid. The energy density of salt crystals is over six times higher than geothermal fluid, which makes long-distance transportation of salt crystals economically feasible. Salt crystals can be used to dehumidify air or provide space cooling in buildings, which alleviates peak demand on the electricity grid by offsetting electricity use for these end uses. This helps improve the grid’s stability and resilience. High-energy storage density, fast crystallization, and dissolution of salt crystals are all critical to the viability and performance of the MSTB system. Therefore, the design and operation of MSTB systems need to ensure effective generation and dissolution of salt crystals inside the MSTB. To achieve this target, this seedling project developed an experimental apparatus for characterizing the crystallization and dissolution processes. The energy density and potential latent cooling capacity of the MSTB are also evaluated based on lab test results. The crystallization results showed that the generated lithium chloride hydrate crystals are fluffy, the crystallization process lasts about 50 min, and the maximum crystal fraction (i.e., the ratio of crystal mass to the mass in the MSTB) can be up to 51.1% of the total mass in the MSTB at a solution flow rate of 1.58 g/s. The dissolution results show that the salt crystals in the MSTB can be fully dissolved within 15–28 min, based on different test conditions. Reducing solution flow rate and cooling water temperature can achieve increased energy storage density and crystal fraction. While the increase in the discharge rate (i.e., latent cooling capacity for dehumidifying air) is achieved by increasing flow rate and temperature of inlet diluted solution, as well as by using a pump for internal solution circulation, the discharge rate increases by 38%, from 0.95 kW to 1.31 kW. Compared with increasing the inlet solution flow rate, power consumption of salt solution transportation can be reduced by using a pump for internal solution circulation. The crystallization test results also showed that the maximum energy storage density is 981.8 kJ/kg, and the maximum discharge rate of the dissolution tests is ≤1.79 kW. Both are above the target values of 900 kJ/kg and 1.75 kW) for this project. The work reported here proves the feasibility and advancement of the MSTB system, which is helpful to the further study and improvement of the MSTB system.

15 GEOTHERMAL ENERGY↗

Field Validation of a Smart Energy Recovery Ventilation System Using Low-Cost Indoor Air Quality Sensors

This project is a field validation, using low-cost indoor air quality (IAQ) sensors, of a smart ventilation system that can help low-load homes in humid environments maintain acceptable indoor humidity conditions while providing adequate ventilation according to ASHRAE 62.2. The objectives of this research were to (1) address builders’ concerns with mechanical ventilation in humid environments and (2) answer the question of whether smart control logic helps with occupant comfort and the creation of a more acceptable indoor environment. To address the objectives of the study, the Southface team collected field data for one year in four Charleston, South Carolina, new construction homes in order to determine the differences in occupant comfort; comfort metrics; IAQ; and heating, ventilating, and air-conditioning (HVAC) energy consumption when toggling biweekly between an energy recovery ventilator (ERV) operating continuously and an ERV operating with smart, time-varying humidity control logic. The smart ventilation algorithm under consideration in this field test did create a less humid indoor environment on an annual basis as quantitatively measured through temperature and relative humidity (T/RH) readings, expressed most discernably as “percentage of time above 60% RH” and “percentage of time above 55°F dewpoint.” However, the difference it made was inconsistent during the spring, summer, and fall months, and it was only directionally consistent during the winter months. We suspect that this is primarily due to the long runtimes and concomitant dehumidification activity of the air-conditioning (A/C) units in response to the high sensible loads in Charleston. The effect of the smart ventilation algorithm was not discernable to the occupants in this study, as recorded through seasonal surveys.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Gyrosole™ and Solar Thermal HVAC Technology for 20-60kW Applications, Final Report, CRADA No. TC02164.0

This was a collaborative effort between Lawrence Livermore National Security, LLC as manager and operator of Lawrence Livermore National Laboratory (LLNL) and Sol Xorce LLC to develop LLNL’s Gyrosole™ solar thermal energy system. The original scope of the CRADA project was to develop LLNL’s Gyrosole™thermal-powered motor technology for solar thermal energy system use, and was originally entitled, "Development of Gyrosole™ Solar Thermal Technology for 20-60 kW Applications". The scope and title of the project were later modified under Amendment One to the CRADA. The technical objective of this CRADA project was to develop Gyrosole™ motor technology so that it is marketplace-ready, and to produce a motor prototype that: Produces 50kW power at >22% efficiency; Operates oil-free; Has sufficient reliability and lifetime to be suitable for both commercial and residential applications; Costs less than $100 per kW installed to produce at scale; and, Can be combined cost-effectively to produce 200kW. The motor prototype would be integrated into model systems that provide electricity generation in combination with air/water heating, heat-pump driven cooling, desiccant dehumidification, and light industrial heat supply.

14 SOLAR ENERGY↗

Heat and Mass Transfer in Hygroscopic Hydrogels

Hygroscopic hydrogels have emerged as a scalable material capable of high-performance vapor sorption for atmospheric water harvesting, dehumidification, and passive cooling due to their fast kinetics and high water uptake. Despite extensive research interest, there is a lack of understanding of the governing energy and mass transport mechanisms within the hydrogels, which hinders their optimization. Here we present a model that explains sorption and desorption in hygroscopic hydrogels for the first time. Our model couples vapor transport in the hydrogel micropores, liquid transport in the polymer nanopores, and heat transport in the porous hydro-gel to accurately capture experimentally observed sorption and desorption data. The knowledge obtained from this model can therefore guide the design of hygroscopic hydrogels and enable improved performance in multi-ple sorption-based applications.

36 MATERIALS SCIENCE↗

Maximizing Uptake of Hygroscopic Hydrogels Through Extreme Swelling-Induced Salt Loading

Hygroscopic hydrogels have emerged as scalable and low-cost materials with the potential of high-performance vapor sorption for atmospheric water harvesting, dehumidification, and passive cooling. Despite extensive research interest aimed at improving hygroscopic hydrogels, devices using these materials still exhibit insufficient performance, partly due to limited water uptake of the hydrogels. In this work, we study the swelling dynamics of hydrogels in aqueous lithium chloride solutions and use this to achieve extreme salt loading of hygroscopic hydrogels. By rationally tuning the salt concentration used for swelling we achieve successful synthesis of hygroscopic hydrogels with high water uptake of 1.76 g/g, 2.53 g/g, 3.80 g/g at relative humidites of 30%, 50%, and 70%, respectively, exceeding previous hydrogels by over 19%. These water uptakes bring the performance of hydrogels within ≈91% of the fundamental limit of commonly used hygroscopic salts, while still avoiding leakage problems common in salt solutions. Furthermore, we elucidate via models the maximum uptake achievable without leakage as a function of the operating relative humidity and hydrogel swelling ratio. The insights from this work can be used to design hygroscopic hydrogels with exceptional performance for a wide variety of sorption applications to tackle global challenges such as water scarcity and energy efficiency.

25 ENERGY STORAGE↗

Structure-Property Relationships of Hydrogel-Salt Composites for Extreme Sorption Performance

Hydrogel-salt composites have emerged as a promising low-cost material for a wide range of sorption applications including thermal energy storage, atmospheric water harvesting, and dehumidification. Despite significant efforts devoted to the synthesis of novel hydrogels and their implementation in sorption devices, very little is known about the fundamental connection between the hydrogel structure and composition with their material-level properties. This knowledge, however, is critical to enable the rational design of high-performance hydrogels targeted at the various applications. In this work, we elucidate via experiments and modeling the link between the hydrogel structure, including its salt content and polymer nanostructure, and its sorption properties. Using lithium chloride-embedded polyacrylamide hydrogels as model systems, we demonstrate that the hydrogel uptake and its kinetics are dominated by the content and properties of the salt. In fact, the polymer nanostructure has no a minor effect in its sorption performance. Based on our experimental insights, we develop a model for the simultaneous diffusion of water and salts in hydrogels, which helps to explain the observed relationship between hydrogel structure and its sorption properties. Furthermore, we leverage these insights to synthesize hydrogels with record-high water vapor uptakes of 1.79 g/g, 2.58 g/g, 3.86 g/g, and 8.51 g/g at 30%, 50%, 70%, and 90% relative humidity, respectively, owing to the use of large amounts of highly hygroscopic salts. By demonstrating the structure-property relationships, this work enables the rational design of salt-embedded hydrogels for low-cost and high-performance thermal energy storage, atmospheric freshwater production, and space conditioning.

Díaz-Marín, Carlos D↗

Field Validation of Packaged RAD-AC HVAC System: Efficiency and Load Shifting via Electrochemical Regeneration of Liquid Desiccants

In this project, Mojave and SRI have demonstrated field validation and load shifting of liquid desiccant air conditioning systems with two liquid desiccant dedicated outdoor air system (DOAS) air conditioner units – one employing traditional thermal desiccant regeneration and the other utilizing Mojave’s novel electrochemical desiccant regeneration technology based on Redox Assisted electrodialysis. The Redox Assisted Dehumidification Air Conditioning (RAD-AC) technology is further developed and validated in this work to demonstrate an Integrated Seasonal Moisture Removal Efficiency (ISMRE) > 5.0 kg/kWh and shifting of ≥ 10% electric load in ≤ 72 hours. Furthermore, the longevity and durability of Mojave’s liquid desiccant air conditioning technology is validated in field testing of the thermally regenerated unit, with the unit demonstrating operation with >90% uptime while experiencing an efficiency degradation of < 10% during a testing campaign of over 5400 hours.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design of a Proportional-Control-Based Advanced Control Strategy for Independent Temperature and Humidity Control of a Pre-Cooled Desiccant Air Cooling System

In this study, the control of a desiccant-wheel-based evaporative cooling system with a double-layer dew-point cooler system is emphasized. There are two dew-point evaporative coolers in the system and the air taken inside is subjected to pre- and post-cooling processes. The dehumidification process of the air taken in is carried out by the desiccant wheel after the pre-cooling process. A proportional-based control strategy has been developed to adjust the temperature and relative humidity of the room quickly and robustly with different operation modes for actuators to bring comfort with less energy consumption. In addition, an automatic Stop/Run mode has been added to the control strategy to save extra energy. With the developed control strategy, enabling the actuators to switch between the operation modes, more energy savings are achieved compared to both traditional ON/OFF and proportional controls. The accuracy and applicability of the developed control strategy were analyzed and it was observed that the room comfort reached the desired levels successfully under all disruptive effects. The control inputs and the energies consumed by all the actuators were investigated and it was determined that 21.19% more energy savings are provided by adding the automatic Stop/Run feature. With the multi-mode control strategy, a total of 40.90% less energy consumption is achieved compared to the classical ON/OFF control technique. Thus, it is seen that the controller developed for the desiccant-wheel-based evaporative cooler is a viable method to provide fast and robust comfort conditions with less energy.

42 ENGINEERING↗

Synergistic Density Functional Theory and Molecular Dynamics Approach to Elucidate PNIPAM–Water Interaction Mechanisms

This study employs Density Functional Theory (DFT) and Molecular Dynamics (MD) simulations to investigate interactions between water molecules and Poly(N-isopropylacrylamide) (PNIPAM). DFT reveals preferential water binding sites, with enhanced binding energy observed in the linker zone. Quantum Theory of Atoms in Molecules (QTAIM) and electron localization function (ELF) analyses highlight the roles of hydrogen bonding and steric hindrance. MD simulations unveil temperature-dependent hydration dynamics, with structural transitions marked by changes in the radius of gyration (Rg) and the radial distribution function (RDF), aligning with DFT findings. Our work goes beyond prior studies by combining a DFT, QTAIM and MD simulations approach across different PNIPAM monomer-to-30mer structures. It introduces a systematic quantification of pseudo-saturation thresholds and explores water clustering dynamics with structural specificity, which have not been previously reported in the literature. These novel insights establish a more complete molecular-level picture of PNIPAM hydration behavior and temperature responsiveness, emphasizing the importance of amide hydrogen and carbonyl oxygen sites in hydrogen bonding, which weakens above the lower critical solution temperature (LCST), resulting in increased hydrophobicity and paving the way for understanding water sorption mechanisms, offering guidance for future applications such as dehumidification and atmospheric water harvesting.

08 HYDROGEN↗

Summary report of technical discussion, NASA-ERDA solar energy proposal

The impact of the reduced energy requirements and cooling loads of solar collectors is assessed. Energy conservation measures to reduce the energy consumption have been implemented. It is indicated that solar chemical dehumidification was more efficient than solar absorption.

Source record↗

Investigation of humidity control via membrane separation for advanced Extravehicular Mobility Unit (EMU) application

This paper describes the development of a membrane-based process for dehumidifying the Extravehicular Mobility Unit (EMU). The membrane process promises to be smaller, lighter, and more energy efficient than the other technologies for dehumidification. The dehydration membranes were tested for 90 days at conditions expected to be present in the EMU. The results of these tests indicate that membrane-based technology can effectively control humidity in the EMU.

Newbold, D. D.↗

Water vapor recovery from plant growth chambers

NASA is investigating the use of plant growth chambers (PGCs) for space missions and for bases on the moon and Mars. Key to successful development of PGCs is a system to recover and reuse the water vapor that is transpired from the leaves of the plants. A design is presented for a simple, reliable, membrane-based system that allows the recovery, purification, and reuse of the transpired water vapor through control of temperature and humidity levels in PGCs. The system is based on two membrane technologies: (1) dehumidification membrane modules to remove water vapor from the air, and (2) membrane contactors to return water vapor to the PGC (and, in doing so, to control the humidity and temperature within the PGC). The membrane-based system promises to provide an ideal, stable growth environment for a variety of plants, through a design that minimizes energy usage, volume, and mass, while maximizing simplicity and reliability.

Ray, R. J.↗