Search NASA⌕ Search

SEARCH · Search NASA

Results for “Demand management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Best Practices for Resilience in Smart Grid-Interactive Efficient Buildings

The Federal Energy Management Program (FEMP) supports federal agencies' energy decisions with information and guidance on design, funding, and operations to ensure federal buildings are efficient and resilient. The modernization of building infrastructure and the evolution of buildings to support decarbonization involves complex implementation of multiple components across several systems. This includes energy-efficient equipment, on-site energy generation and storage systems, and control systems. These systems have operational modes that can operate more efficiently if they are able to behave responsively to the conditions of the electrical grid. These grid-interactive efficient buildings (GEB) allow facilities to manage power demand according to operational constraints and market signals issued by grid operators. With proper design and planning, these same capabilities have the potential to enable building and facility resilience - coordinating with microgrids, maintaining power on critical circuits to sustain essential operations, and monitoring building health and safety status during an outage. By managing the load of buildings, GEBs can also reduce the cost of backup generation and make better use of renewable power sources on site. This document outlines some of the processes and considerations to guide the design and operation of GEBs in ways that promote facility resilience.

building decarbonization↗

Stochastic Pricing Game for Aggregated Demand Response Considering Comfort Level

In recent years, demand response (DR) has been explored as a fundamental strategy for demand-side management due to its advantages in mediating intermittency of renewable energy generation, load shifting, etc. To engage customers in DR programs, several deterministic price-based DR strategies have been developed and implemented. However, the stochastic weather conditions and occupants' consumption behaviors often make the deterministic solution less robust to uncertainties. In this paper, with the consideration of the uncertainties, a stochastic Stackelberg game is proposed to model the price-demand negotiation between a distributed system operator and load aggregators, where the virtual battery constraints are extracted from the building thermostatically controlled loads (TCLs)‘ characteristics to guarantee comfortable TCLs' levels. Following the negotiation, a priority-based control method is used to allocate the optimal aggregated power DR profile at the building level and track the power signal. Several groups of experiments have demonstrated the effectiveness and robustness of the stochastic solutions.

Chen, Yang↗

A Case Study in NREL DERMS Asset Management Implementation

The National Renewable Energy Laboratory (NREL) and Smarter Grid Solutions (SGS) plan to present a case study on their implementation of SGS' Strata Grid Distributed Energy Resource Management System at NREL's Energy Systems Integration Facility (ESIF). The ESIF is one of the nation's premier energy systems integration laboratory facilities focused on development and deployment of clean energy technologies and resilient delivery systems. NREL looked for a DERMS to install at the ESIF that is capable of replicating real world scenarios to control and monitor distributed devices from small residential scale to the grid substation level. The DERMS system demonstrates the use cases of beneficial operation and coordination of modern grid devices, leverage DERs for improved grid planning and operation, demand-side management and customer engagement through bidirectional communication with utilities and energy market operations. The presentation will cover the delivery strategy of NREL and SGS, how the use cases help NREL's research, and NREL and SGS plan to expand the system and use cases.

ARIES↗

Model Predictive Control for a Grid-interactive Efficient Thermal Storage-integrated Heat Pump System

Building heating and cooling systems can be used to overcome the mismatch between the intermittent supply of renewable power and the fluctuating demand for electricity. A novel underground thermal energy storage integrated with a dual-source heat pump has been proposed to mitigate the mismatch while meeting the thermal demand of buildings efficiently. Conventional thermostat control with heuristic rules cannot provide intelligent decisions to maximize the thermal efficiency and flexibility of the proposed system. Advanced control strategies like model predictive control (MPC) have provided a new paradigm for grid-interactive efficient building operation with the advancement of computation and sensing. This study developed an MPC for the proposed system to provide grid service for Demand Side Management and minimize the operating cost of building owners. A control-oriented dynamic model of the proposed system has been developed. Given an objective function and proper constraints, an optimization problem is formulated to determine the optimal control strategy of the system. Dynamic Programming is adopted to solve the optimization problem. A rule-based control (RBC) is also developed to achieve similar goals. Short-term simulations are conducted to compare the system performance resulting from the two controls. The simulation results indicate that the MPC performs more intelligently than the RBC in charging thermal energy storage and selecting heat pump sources by taking advantage of the predicted cooling demands of the building and the performance of the integrated system. As a result, the MPC could save energy and reduce operating costs compared with the RBC. A case study shows that, for a 3-day operation, the MPC saves 36.9% energy and reduces 38.5% operating cost compared with the RBC.

Shi, Liang↗

Detailed Laboratory Evaluation of Electric Demand Load Shifting Potential of Controlled Heat Pump Water Heaters

The demand profile management of electric end uses is vital research for utilities and policymakers planning greenhouse gas emission reductions. In this study, detailed laboratory research was conducted on the load shifting potential of 4 grid-connected HPWHs and one electric resistance water heaters (ERWH). The testing applied different CTA-2045 shed and critical peak command designs under three water draw profiles. Highly-controlled laboratory experiments were conducted in Florida. One of the four HPWHs was a prototype incorporating the new CTA-2045-B protocol feature allowing ‘advanced’ load-up above tank setpoint. A three-hour morning (6 – 9 AM) and four-hour evening curtailment (4 – 8 PM) were defined as the shed or critical peak periods reflecting high-value control periods for utility coincident load for system-wide electric demand reductions. Tests were performed under baseline conditions (no load shift) and under varied load-shifting schemes, including load up and advanced load up, ahead of shed and critical peak commands. Data were collected from December 2020 – February 2022 in the laboratory and compared with field experiments in Florida and the Pacific Northwest. Grid-connected HPWHs were found to reduce peak demand by up to 0.47 kW compared to uncontrolled HPWH units, depending on time of day, control scheme, draw profile, and temperature cluster. The load up strategy demonstrated the ability of all units to utilize heat pump mode for extended periods ahead of peak events. Demand reductions for the HPWHs were much larger when compared with the ERWH— up to 1.64 kW with large hot water draws in winter.

Fenaughty, Karen↗

Advancing Grid Resilience through Smart Charge Management: Findings from Maryland’s Pilot

This report presents research findings from a four-year Smart Charge Management (SCM) pilot program conducted by Maryland’s largest electric utilities—Baltimore Gas and Electric (BGE), Potomac Electric Power Company (Pepco), and Delmarva Power & Light (DPL)—to evaluate strategies for optimizing electric vehicle (EV) charging loads and enhancing grid stability. Supported by the U.S. Department of Energy (DOE), Argonne National Laboratory collaborated with all project partners and examined the effectiveness of Time-of-Use (TOU) and Load Balancing (LB) strategies in managing peak demand, deferring costly infrastructure upgrades, and reducing grid constraints at the feeder level. Using charging data from over 4,600 EV drivers, the study analyzed SCM’s impact on the distribution systems of BGE and Pepco, which consists of over 2000 feeders. Unlike prior research that focused on system-wide trends or synthetic feeders, this analysis offers granular, feeder-level insights based on real-world operational data. It highlights how transformer density, load profiles, and infrastructure constraints influence smart charging performance. Results show feeder-level conditions play a crucial role in SCM effectiveness, with most feeders benefiting more from LB, while TOU-based SCM may be sufficient for others. By 2035, LB reduced peak charging loads by 27% on average, compared to 23% under TOU-based SCM, though some feeders saw reductions exceeding 35%, while others experienced minimal impact. Feeders with higher transformer utilization and limited capacity benefited more from LB, which more effectively distributed charging demand during off-peak hours. Beyond reducing grid constraints, SCM offers long-term operational and financial benefits. By shifting EV charging demand strategically, utilities can optimize asset utilization, delay infrastructure investments, and enhance grid performance. In terms of infrastructure upgrade deferrals, at the feeder level, LB consistently reduced peak charging loads and resulting infrastructure upgrade costs, particularly in high EV enrollment areas, decreasing the number of overloaded transformers by up to 35%, while TOU-based SCM achieved 20-30% reductions depending on feeder characteristics. At the system level, LB has the potential to defer total upgrade costs by $\$$186 million for BGE, compared to $\$$159 million under TOU-based SCM. For Pepco, TOU-based SCM performed slightly better, deferring upgrade costs by $\$$30 million, compared to $\$$29 million under LB. Section 4.5 reviews some of the system differences between BGE and Pepco. However, as EV adoption scales, TOU-based SCM will introduce secondary peak charging loads, reinforcing the need for more advanced, adaptive SCM approaches to prevent new grid challenges. As EV adoption continues to grow, feeder-level managed charging strategies will be essential for mitigating grid stress, improving infrastructure efficiency, and maintaining energy affordability for consumers. This report provides critical insights for utilities, Public Utility Commissions (PUCs), and state agencies on the role of feeder-specific smart charging in infrastructure planning, policy development, and grid modernization. The findings underscore the importance of tailored, data-driven SCM solutions that align with local grid conditions, ensuring a resilient, cost-effective transition to increasing EV adoption while safeguarding distribution system performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utilizing commercial heating, ventilating, and air conditioning systems to provide grid services: A review

The modern power grid faces multiple challenges due to an increase in the adoption of renewable generation, such as dynamically balancing supply and demand at different time scales. Demand side management in buildings plays a vital role in achieving this balance because buildings can provide grid services through a variety of building assets. However, the development of grid-interactive, efficient buildings is still in its infancy, and a systematic and holistic understanding of grid service delivery strategies in terms of energy efficiency, load shifting, load shedding and load modulating is still limited. This paper is a comprehensive review of the development and application of building-level control strategies for utilizing heating, ventilating, and air conditioning systems to provide grid services. These strategies have been investigated through numerical and experimental studies. Control algorithms, such as heuristic rule-based control and model-based control, have been used to enable the automatic control delivery of grid services. The advantages and disadvantages of the strategies are summarized and discussed. Finally, research trends are also identified, which include considering predicted mean vote-based and occupant-based thermal comfort, modeling of occupant behavior, integrating power grid operations with building control, and combining different demand flexibility modes in the control design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Detailed Evaluation of Electric Demand Load Shifting Potential of Heat Pump Water Heaters

Future utilities will emphasize home appliances to reduce greenhouse gas emissions while providing electric load shifting and demand profile management. Heat pump water heaters (HPWH) have demonstrated the ability to cut water heating energy by more than 65% compared with conventional electric resistance waters (ERWH). Laboratory research was conducted on the load shifting potential of grid-connected heat pump water heaters (HPWH), compared to ERWHs. Testing applied different CTA-2045 command designs. Highly-controlled laboratory experiments were conducted on one ERWH and four HPWHs, including a prototype incorporating the new CTA-2045-B protocol feature allowing ‘advanced’ load up above the tank setpoint. The prototype unit with the B-protocol increased tank temperature by 15oF (8.3C) under the advanced load up providing an increase of 1.8 kWh of storage for a 50-gallon (189 liter) tank. The prototype includes a built-in mixing valve to meet anti-scalding codes. With the load-shaping ability of CTA-2045-B, utilities might be able to store excess renewable energy in connected tanks when renewable wind and solar resource production is high. Tests were performed under baseline conditions (no load shift) and under several load-shifting schemes, including load up and advanced load up, ahead of shed commands. Grid-connected HPWHs reduced peak demand by as much as 0.5 kW, depending on tank volume, time of day, control scheme, and draw profile.

heat pump water heater, Demand flexibility, load s↗

Sensitivity Analysis of Occupant Preferences on Energy Usage in Residential Buildings: Preprint

Residential buildings, accounting for 37% of the total electricity consumption in the United States, are suitable for demand-side management (DSM) programs to support effective and economical operation of the power system. A home energy management system (HEMS) enables residential buildings to participate in such programs. It is important to account for occupant preferences in HEMS to ensure occupant satisfaction while participating in DSM programs. For example, people who prefer a higher thermal comfort level are likely to consume more energy. In this study, we used foresee™, a HEMS developed by the National Renewable Energy Lab (NREL), to perform a sensitivity analysis of occupant preferences with the following objectives: minimize utility cost, minimize carbon footprint, and maximize thermal comfort. To incorporate the preferences into the HEMS, the SMARTER method was used to derive a set of weighting factors for each objective. We performed week-long building energy simulations using a model of a home in Fort Collins, Colorado, where there is mandatory time-of-use electricity rate structure. The foreseeTM HEMS was used to control the home with six different sets of occupant preferences. The study shows that occupant preferences can have a significant impact and is important to consider when modeling residential buildings. Results show that the HEMS could achieve energy reduction ranging from 3% to 21%, cost savings ranging from 5% to 24%, and carbon emission reduction ranging from 3% to 21%, while maintaining a low thermal discomfort level ranging from 0.78 K-hour to 6.47 K-hour in a one-week period during winter. These outcomes quantify the impact of varying occupant preferences and will be useful for controlling the electrical grid and developing HEMS solutions.

carbon footprint↗

Controlling distributed energy resources via deep reinforcement learning for load flexibility and energy efficiency

Behind-the-meter distributed energy resources (DERs), including building solar photovoltaic (PV) technology and electric battery storage, are increasingly being considered as solutions to support carbon reduction goals and increase grid reliability and resiliency. However, dynamic control of these resources in concert with traditional building loads, to effect efficiency and demand flexibility, is not yet commonplace in commercial control products. Traditional rule-based control algorithms do not offer integrated closed-loop control to optimize across systems, and most often, PV and battery systems are operated for energy arbitrage and demand charge management, and not for the provision of grid services. More advanced control approaches, such as MPC control have not been widely adopted in industry because they require significant expertise to develop and deploy. Recent advances in deep reinforcement learning (DRL) offer a promising option to optimize the operation of DER systems and building loads with reduced setup effort. However, there are limited studies that evaluate the efficacy of these methods to control multiple building subsystems simultaneously. Additionally, most of the research has been conducted in simulated environments as opposed to real buildings. This paper proposes a DRL approach that uses a deep deterministic policy gradient algorithm for integrated control of HVAC and electric battery storage systems in the presence of on-site PV generation. The DRL algorithm, trained on synthetic data, was deployed in a physical test building and evaluated against a baseline that uses the current best-in-class rule-based control strategies. Performance in delivering energy efficiency, load shift, and load shed was tested using price-based signals. The results showed that the DRL-based controller can produce cost savings of up to 39.6% as compared to the baseline controller, while maintaining similar thermal comfort in the building. The project team has also integrated the simulation components developed during this work as an OpenAIGym environment and made it publicly available so that prospective DRL researchers can leverage this environment to evaluate alternate DRL algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Calibration of urban building energy model using smart meter data for district peak load prediction

Urban building energy modeling (UBEM) is a powerful approach to assessing baseline building energy performance and retrofits with new technologies across building stocks in cities. However, the accuracy of UBEM is often constrained by the limited availability of reliable data about building characteristics and operations, such as envelope efficiency levels, HVAC system performance, and end-use load patterns. Existing research has performed UBEM calibration using annual or monthly energy consumption data, which falls short when higher-resolution time series applications are needed, such as peak load prediction for utility operation planning. This study presents a new framework for calibrating building energy models at urban scale using smart meter data, targeting the accurate prediction of summer peak electricity loads to support robust grid planning. The framework first integrates various data sources to enhance baseline input assumptions for building models, and then calibrates the baseline models through a pattern-matching approach. A case study using CityBES and two years of AMI data from over 9000 residential customers in Portland, Oregon, demonstrated the workflow and its effectiveness. The calibrated models achieved a daily peak load mean absolute percentage error of 2.6 % during the heatwave in the calibration year, and 2.0 % in the validation year using another year of AMI data. Using the calibrated models, we analyzed the demand flexibility potential of the district building stock as an application of UBEM calibration. The findings affirm the appropriate use of UBEM for peak electric load forecasting and demand side management at the utility distribution system level.

AMI data↗

Numerical modeling and parametric study of a dual purpose underground thermal battery

We report integrating thermal energy storage with building energy systems can enable flexible building electric demands at buildings to help mitigate the mismatch between electricity supply and demand. A novel building heating and cooling system that integrates a dual-source heat pump with hybrid thermal storage named dual-purpose underground thermal battery (DPUTB) has been developed for reshaping building electric demands. The proposed DPUTB integrated geothermal heat pump system is an original innovation that enables Grid-interactive Energy Efficient buildings. This paper focuses on the study of the novel DPUTB. The DPUTB works as both a thermal storage tank (an inner tank) and a ground heat exchanger (an outer tank separated from the inner tank by the insulation material). High fidelity and computationally effective models are needed to predict the performance of the novel DPUTB. This study has developed a simplified dynamic model for the DPUTB according to heat transfer and energy conservation principles and validated it by using experimental data obtained from testing a small-scale DPUTB apparatus. A parametric study was conducted to identify a design that can achieve the target thermal storage performance of load shift and energy efficiency. The parametric study results show that the inner tank shell thermal conductivity and the phase change material's melting point are the two most influencing factors on the performance of the DPUTB. One single full-size DPUTB with the identified design could provide 1-ton cooling (3.51 kW) with the supply temperature lower than 11 °C for 4 hours in summer after being fully charged in 8 hours. The inner tank filled with phase change material is for cooling thermal storage as a latent tank in the design. However, its capacity can be as high as 60 MJ as a sensible water tank for heating storage in winter. In the future study, the DPUTB model will be incorporated into the dual-source heat pump system for evaluating the overall system performance of demand side management in the long term.

25 ENERGY STORAGE↗

Building energy efficiency and load flexibility optimization using phase change materials under futuristic grid scenario

This work investigates the energy savings and load flexibility capacity of phase change material (PCM) integrated into building envelope under a future energy generation scenario, where 80% of the energy load comes from renewable sources. Using community-scale modeling, we first determine the net thermal storage required to fully manage the demand variability at a utility grid, and then using whole-building simulations we optimize operating parameters - such as PCM thickness, latent heat, interior setpoint profile, PCM distribution, and heat transfer coefficient - to determine the optimal conditions required for maximum energy reduction and load flexibility without compromising occupants' thermal comfort. The optimal PCM-integrated envelope proposed in this study can provide annual load flexibility up to 33.6% and annual energy savings up to 10.8% in a lightweight residential building located in Baltimore, MD. This study is relevant given the increasing contributions of renewable energy in the total energy generation mix, leading to a significant time-imbalance between peak energy demand and peak energy production. While thermal energy storage using PCM is a recognized technique, there is no known prior study dedicated to examining the thermal performance of PCM-integrated envelope under future energy generation scenarios. This study bridges the research gap by investigating a practical way to implement PCMs in the buildings and maximize the energy efficiency as well as load flexibility related benefits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Occupant-driven end use load models for demand response and flexibility service participation of residential grid-interactive buildings

As demand response becomes increasingly used as a tool to support improved grid flexibility, it is important to consider that there are many potential types of energy end uses that may be used to support such flexibility. Residential appliances, often accounting for 30 % or more of residential energy use, are a currently untapped source of demand flexibility, particularly when aggregated together across homes. To date there has been very limited analysis of residential appliances for use as grid-interactive loads. As such, this research uses disaggregated energy end use data for 564 households, to model the electricity demand flexibility potential of the use of residential dishwashers, clothes washers, clothes dryers, ovens, and ranges (oven + stovetop) on both weekdays and weekends. This includes both at the building level, as well as aggregated to the grid level, specifically the Midcontinent Independent System Operator (MISO) region. This study was divided into two parts. Part 1 focuses on determining appliance-level loads, and Part 2, which involves aggregation to the grid. Findings suggest that among the studied appliances, clothes dryers provide the greatest demand reduction potential for most times of the day, followed by dishwashers and clothes washers. The maximum potential reduction for clothes dryers is found to be approximately at 11:00 a.m. and this potential sustains throughout most of the daytime period. When considering the willingness of households to participate, based on a survey of households in the Midwest region, clothes dryers still have the most potential for demand reduction. The availability of appliances for load modulation on weekdays and weekends indicates similar load reduction potential for all appliances. Overall, the results of this study suggest that there is an opportunity for shifting appliance usage to optimize grid efficiency and enhance demand response strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

What does the future hold for utility electricity efficiency programs?

Here, this study develops projections of future spending and savings from electricity efficiency programs funded by electric utility customers in the United States through 2030 based on three scenarios. Our analysis relies on detailed bottom-up modeling of current state energy efficiency policies, demand-side management and integrated resource plans, and regulatory decisions. The three scenarios represent a range of potential outcomes given the policy environment at the time of the study and uncertainties in the broader economic and state policy environment in each state. We project spending to increase to $8.6 billion in 2030 in the medium scenario, about a 45 percent increase relative to 2016 spending. In the high case, annual spending increases to $11.1 billion in 2030 and remains relatively flat in the low case ($6.8 billion in 2030). Our analysis suggests that electricity efficiency programs funded by utility customers will continue to impact load growth significantly at least through 2030, as savings as a percent of retail sales are forecast at 0.7 percent in the medium scenario and 0.98 percent in the high scenario.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Developing a small participant framework: An investigation of mode choice influential factors

An in-depth comprehension of the changing impact of mode choice influencing factors is essential in planning for behavior-adaptive mode shift policies. This study developed a framework to investigate a method of evaluation of the changes in mode choice using a small participation pool. A field application in Pima County, Arizona was developed to test the developed framework to evaluate the impact of a real transit experience. Twenty-two participants were recruited and repeated measurements were taken before and after their transit trip. The results revealed that people are less susceptible to their mental biases after a transit trip and consider more objective elements such as walking time. The developed framework resulted in successful evaluation methods that are reproducible for other application study designs. Thus, the results further present that low participant recruitment in application-based field studies can be accomplished using this developed methodology, for other regions and studies.

99 GENERAL AND MISCELLANEOUS↗

E3SM‐GCAM: A Synchronously Coupled Human Component in the E3SM Earth System Model Enables Novel Human‐Earth Feedback Research

Abstract Modeling human‐environment feedbacks is critical for assessing the effectiveness of climate change mitigation and adaptation strategies under a changing climate. The Energy Exascale Earth System Model (E3SM) now includes a human component, with the Global Change Analysis Model (GCAM) at its core, that is synchronously coupled with the land and atmosphere components through the E3SM coupling software. Terrestrial productivity is passed from E3SM to GCAM to make climate‐responsive land use and CO 2 emission projections for the next 5‐year period, which are interpolated and passed to E3SM annually. Key variables affected by the incorporation of these feedbacks include land use/cover change, crop prices, terrestrial carbon, local surface temperature, and climate extremes. Regional differences are more pronounced than global differences because the effects are driven primarily by differences in land use. This novel system enables a new type of scenario development and provides a powerful modeling framework that facilitates the addition of other feedbacks between these models. This system has the potential to explore how human responses to climate change impacts in a variety of sectors, including heating/cooling energy demand, water management, and energy production, may alter emissions trajectories and Earth system changes. Plain Language Summary Earth system models help us understand how humans are changing the climate. Currently, these models do not include human systems, so predetermined greenhouse gas, aerosol, and land use change data are input to these models. These data do not reflect human responses to changes projected by Earth system models. We have added a human component to an Earth system model to represent human responses to environmental change and calculate corresponding greenhouse gas and land use change data instead of using predetermined data. Including this human component changes projections of land use, land carbon storage, and regional climate. Key Points We have incorporated a novel, advanceable human component in an Earth system model to simulate human‐Earth feedbacks Including terrestrial productivity feedbacks from the Earth to the human systems affects land change, crop prices, carbon, and climate Regional effects of including terrestrial productivity feedbacks are greater than global effects because land change is the main driver

E3SM↗