Search NASA⌕ Search

SEARCH · Search NASA

Results for “Design Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Wind farm response to mesoscale-driven coastal low level jets: a multiscale large eddy simulation study

Realistic atmospheric turbulence–wind farm interactions during coastal low-level jet (LLJ) events are captured using high-fidelity, mesoscale-driven large eddy simulations (LES) to understand wind turbine loads, wakes and overall performance. The simulation has been carried out using the ExaWind aeroelastic solver, AMR-Wind. The simulations have been compared against a baseline unstable case matching the wind speed, wind direction and TI at hub-height location. Results indicate that the LLJ has negative impacts on the turbine hub and tower loads, and opens up potential avenues for design load mitigation strategies.

17 WIND ENERGY↗

Wind turbine generator application places unique demands on tower design and materials

The most relevant contractual tower design requirements and goal for the Mod-1 tower are related to steel truss tower construction, cost-effective state-of-the-art design, a design life of 30 years, and maximum wind conditions of 120 mph at 30 feet elevation. The Mod-1 tower design approach was an iterative process. Static design loads were calculated and member sizes and overall geometry chosen with the use of finite element computer techniques. Initial tower dynamic characteristics were then combined with the dynamic properties of the other wind turbine components, and a series of complex dynamic computer programs were run to establish a dynamic load set and then a second tower design.

Kita, J. P.↗

Field Validation of Air-Source Heat Pumps for Cold Climates

Heating energy is the largest end-use for U.S. residential buildings accounting for approximately one-third of residential building energy consumption (EIA 2021). Historically, air-source heat pumps have been limited to temperate climates because of subpar performance at extremely cold outdoor air temperatures. However, recent advances to cold-climate air-source heat pump technology, which typically rely on inverter-driven, variable-speed compressors and variable-speed fans, have significantly improved low-temperature heat pump performance enabling the technology to save energy for many homes in cold climates. The primary objective of this project was to measure in-field performance of centrally ducted, variable-capacity air-source heat pumps in cold climates to validate performance and develop field-based performance maps. The project focused on quantifying heat pump performance at cold temperatures. The sites identified for the study were primarily located in the Northwest United States since homes in the region tend to have all-electric space heating systems and high-efficiency heat pumps have been incentivized in the region for several years. NREL partnered with Ecotope, Inc., a small energy consulting firm located in Seattle, WA, for site recruitment, monitoring equipment installation, data quality management. All the sites included in the study had previously installed a high-efficiency, central heat pump system. One site was in a Denver, CO suburb, which was the only dual fuel heat pump in the study. We used airside and power measurements, collected at 5-second intervals, to quantify heat pump capacity, coefficient of performance (COP), and auxiliary heater energy consumption. We developed algorithms to automatically determine the heat pump operating mode including defrost and auxiliary heating operation. A whole-house thermal and duct audit was completed during the initial site visit to estimate winter heating loads and assess heat pump sizing. Whole-home heating design loads were calculated at ASHRAE 99% design temperatures and compared to manufacturer-reported maximum capacities to assess the heat pump sizing at each site.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Centaur Standard Shroud (CSS) static ultimate load structural tests

A series of tests were conducted on the jettisonable metallic shroud used on the Titan/Centaur launch vehicle to verify its structural capabilities and to evaluate its structural interaction with the Centaur stage. A flight configured shroud and the interfacing Titan/Centaur structural assemblies were subjected to tests consisting of combinations of applied axial and shear loads to design ultimate values, including a set of tests on thermal conditions and two dynamic response tests to verify the analytical stiffness model. The strength capabilities were demonstrated at ultimate (125 percent of design limit) loads. It was also verified that the spring rate of the flight configured shroud-to-Centaur forward structural deflections of the specimen became nonlinear, as expected, above limit load values. This test series qualification program verified that the Titan/Centaur shroud and the Centaur and Titan interface components are qualified structurally at design ultimate loads.

Source record↗

A Method for Computing Leading-Edge Loads

In this report a formula is developed that enables the determination of the proper design load for the portion of the wing forward of the front spar. The formula is inherently rational in concept, as it takes into account the most important variables that affect the leading-edge load, although theoretical rigor has been sacrificed for simplicity and ease of application. Some empirical corrections, based on pressure distribution measurements on the PW-9 and M-3 airplanes have been introduced to provide properly for biplanes. Results from the formula check experimental values in a variety of cases with good accuracy in the critical loading conditions. The use of the method for design purposes is therefore felt to be justified and is recommended.

Rhode, Richard V↗

Investigation of passive atmospheric sounding using millimeter and submillimeter wavelength channels

Activities within the period from July 1, 1992 through December 31, 1992 by Georgia Tech researchers in millimeter and submillimeter wavelength tropospheric remote sensing have been centered around the calibration of the Millimeter-wave Imaging Radiometer (MIR), preliminary flight data analysis, and preparation for TOGA/COARE. The MIR instrument is a joint project between NASA/GSFC and Georgia Tech. In the current configuration, the MIR has channels at 90, 150, 183(+/-1,3,7), and 220 GHz. Provisions for three additional channels at 325(+/-1,3) and 8 GHz have been made, and a 325-GHz receiver is currently being built by the ZAX Millimeter Wave Corporation for use in the MIR. Past Georgia Tech contributions to the MIR and its related scientific uses have included basic system design studies, performance analyses, and circuit and radiometric load design, in-flight software, and post-flight data display software. The combination of the above millimeter wave and submillimeter wave channels aboard a single well-calibrated instrument will provide unique radiometric data for radiative transfer and cloud and water vapor retrieval studies. A paper by the PI discussing the potential benefits of passive millimeter and submillimeter wave observations for cloud, water vapor and precipitation measurements has recently been published, and is included as an appendix.

Gasiewski, Albin J.↗

Investigation of passive atmospheric sounding using millimeter and submillimeter wavelength channels

Activities within the period from January 1, 1992 through June 30, 1992 by Georgia Tech researchers in millimeter and submillimeter wavelength tropospheric remote sensing have been centered around the integration and initial data flights of the MIR on board the NASA ER-2. Georgia Tech contributions during this period include completion of the MIR flight software and implementation of a 'quick-view' graphics program for ground based calibration and analysis of the MIR imagery. In the current configuration, the MIR has channels at 90, 150, 183 +/- 1,3,7, and 220 GHz. Provisions for three additional channels at 325 +/-1,3 and 9 GHZ have been made, and a 325-GHz receiver is currently being built by the ZAX Millimeter Wave Corporation for use in the MIR. The combination of the millimeter wave and submillimeter wave channels aboard a single well-calibrated instrument will provide the necessary aircraft radiometric data for radiative transfer and cloud and water vapor retrieval studies. A paper by the PI discussing the potential benefits of passive millimeter and submillimeter wave observations for cloud, water vapor and precipitation measurements has recently been accepted for publication (Gasiewski, 1992), and is included as Appendix A. The MIR instrument is a joint project between NASA/GSFC and Georgia Tech. Other Georgia Tech contributions to the MIR and its related scientific uses have included basic system design studies, performance analyses, and circuit and radiometric load design.

Gasiewski, Albin J.↗

An Investigation of the Effects of Sweep on the Characteristics of a High-Aspect-Ratio Wing in the Langley 8-Foot High-Speed Tunnel

An untwisted wing, which when unswept has an NACA 65-210 section, an aspect ratio of 9.0 and a taper ration of 2.5:1.0, has been tested with no sweep, and 30 deg and 45 deg of sweepback and sweepforward in conjunction with a typical fuselage at Mach numbers from 0.60 to 0.96 at angles of attack generally between -2 deg and 10 deg in the Langley 8-foot high-speed tunnel. Sweep was obtained by rotating the wing semispans about a point in the plane of symmetry. The normal-force, pitching-moment, profile-drag, and loading characteristics for the wings have been obtained from pressure measurements and wake surveys. The results indicate that the wings with +/-30 deg of sweep experienced the severe changes in characteristics associated with the presence of a shock at higher Mach numbers then did the wing without sweep. The differences between the Mach numbers at which the changes occurred for the wings with +/-30 deg sweep and no sweep were generally slightly less than the factor 1/cosDelta(sub r) times the Mach numbers at which the changes occurred for the unswept wing, Delta(sub r) being the sweep angle. The wings with +/-45 deg of sweep did not experience the changes in the characteristics associated with the presence of shock at an angle of attack of 2 deg at Mach numbers up to the highest test value. The magnitudes of changes in the normal-force and pitching-moment coefficients that occurred were less for the wing with 30 deg of sweep than for the unswept wing. The use of sweepforward was superior to sweepback in delaying and reducing the changes in the normal-force coefficients, but was inferior in delaying and reducing the changes in the profile-drag coefficients. Increasing the Mach number to the highest test values had little effect on the positions of the center of loads on the various configurations for the probable design load conditions.

Whitcomb, Richard T.↗

Improvements of the Load Schedule for the Machine Calibration of a Strain-Gage Balance

The load schedule for the calibration of a six-component force balance in a calibration machine was improved. Now, single-component loads are repeated in regular intervals during the calibration. This approach has several advantages. First, the number of single-component loads increases to about twenty-two percent of all loads and load combinations. Consequently, more accurate numerical estimates of the primary bridge sensitivities can be obtained if global regression is used for the analysis of the calibration data. In addition, single-component repeats make it possible to track the stability of the applied loads during the calibration process. Finally, interactions of single-component repeats can be compared with interactions that are observed during the application of manual loads to the balance. Machine calibration and manual data sets of two force balances are used to illustrate benefits of the new load schedule. It is shown in the examples how differences between the observed interactions of machine calibration and manual data can be quantified. The suggested improvements can also be implemented in the load schedule for the machine calibration of a moment or direct-read balance as long as single-component loads are included that are described in the design load format of the balance.

wind tunnel test↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow With 25% Upsizing Allowance for Heating

This documentation focuses on a single end-use savings shape upgrade - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation and where 25% upsizing (or 125% of the original size) is allowed for heating in colder climates (i.e., heating dominant regions). This document will primarily discuss the additional changes to the sizing algorithm and modeling approach, while a comprehensive overview of the fundamental modeling methodology and background of the VRF HR DOAS upgrade, including applicability and other key assumptions can be found in the original documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System. To provide more context on the 25% upsizing algorithm, if the building is a cooling dominant (e.g., design cooling load higher than design heating load ), then the outdoor unit capacity of the VRF heat pump is sized based on the design cooling load. However, if the building is heating dominant, then this building is a candidate for the 25% upsizing allowance. Once the 25% upsizing is allowed, if the 25% upsized capacity (or 125% from the original size) represented with design condition exceeds the design heating load, then the design heating load is used for calculating the rated capacity of the outdoor unit. And if the 25% upsized capacity represented with the design condition does not exceed the design heating load, then the 25% upsized capacity represented with rated condition is used for the capacity of the outdoor unit while the remaining heating load is handled with the supplemental/backup electric resistance coil.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Open-Loop Control of Adjustable Tuned Mass Dampers for Floating Wind Turbine Platforms

In this study, we demonstrate the ability of adjustable tuned mass dampers (TMDs) to reduce the platform motion of floating offshore wind turbines (FOWTs). The TMDs are located in the hull and provide control authority by varying the amount of water ballast and compressed air in a reservoir over time. The optimal TMD settings depend on the wind and wave conditions of the FOWT. We present an open-loop control scheme that changes the TMD natural frequency based on sea state and a simple method for estimating the peak wave period and significant wave height. The performance of this open-loop control is compared to ideal control of the TMDs (set knowing the exact sea state), a TMD with a constant natural frequency targeting the design load case with the greatest platform motion, and a baseline set of simulations of the platform without TMDs. The constant natural frequency case performs nearly as effectively as the actively controlled case, suggesting that the TMDs can be simply designed for extreme load conditions and provide consistent control over a range of environments; however, the methods used to find the optimal TMD parameters and estimate sea state statistics could be used in other aspects of FOWT control and design.

artificial intelligence↗

Buckling test of a 3-meter-diameter corrugated graphite-epoxy ring-stiffened cylinder

A three m diameter by three m long corrugated cylindrical shell with external stiffening rings was tested to failure by buckling. The corrugation geometry for the graphite epoxy composite cylinder wall was optimized to withstand a compressive load producing an ultimate load intensity of 157.6 kN/m without buckling. The test method used to produce the design load intensity was to mount the specimen as a cantilevered cylinder and apply a pure bending moment to the end. A load introduction problem with the specimen was solved by using the BOSOR 4 shell of revolution computer code to analyze the shell and attached loading fixtures. The cylinder test loading achieved was 101 percent of design ultimate, and the resulting mass per unit of shell wall area was 1.96 kg/sq m.

Davis, R. C.↗

Velocity and rolling-moment measurements in the wake of a swept-wing model in the 40 by 80 foot wind tunnel

Measurements were made in the wake of a swept wing model to study the structure of lift generated vortex wakes shed by conventional span loadings and by several span loadings designed to reduce wake velocities. Variations in the span loading on the swept wing generator were obtained by deflecting seven flap segments on each side by amounts determined by vortex lattice theory to approximate the desired span loadings. The resulting wakes were probed with a three component, hot wire probe to measure velocity, and with a wing to measure the rolling moment that would be induced on a following aircraft. The experimental techniques are described herein, and the measured velocity and rolling moments are presented, along with some comparisons with the applicable theories.

Rossow, V. J.↗

Ground test experience with large composite structures for commercial transports

The initial ground test of each component resulted in structural failure at less than ultimate design loads. While such failures represent major program delays, the investigation and analysis of each failure revealed significant lessons for effective utilization of composites in primary structure. Foremost among these are secondary loads that produce through-the-thickness forces which may lead to serious weaknesses in an otherwise sound structural design. The sources, magnitude, and effects of secondary loads need to be thoroughly understood and accounted for by the designers of composite primary aircraft structures.

Bohon, H. L.↗

Ground test experience with large composite structures for commercial transports

The initial ground test of each component resulted in structural failure at less than ultimate design loads. While such failures represent major program delays, the investigation and analysis of each failure revealed significant lessons for effective utilization of composites in primary structure. Foremost among these are secondary loads that produce through-the-thickness forces which may lead to serious weaknesses in an otherwise sound structural design. The sources, magnitude, and effects of secondary loads need to be thoroughly understood and accounted for by the designers of composite primary aircraft structures.

Bohon, H. L.↗

Simulation of Propellant Loading System Senior Design Implement in Computer Algorithm

Propellant loading from the Storage Tank to the External Tank is one of the very important and time consuming pre-launch ground operations for the launch vehicle. The propellant loading system is a complex integrated system involving many physical components such as the storage tank filled with cryogenic fluid at a very low temperature, the long pipe line connecting the storage tank with the external tank, the external tank along with the flare stack, and vent systems for releasing the excess fuel. Some of the very important parameters useful for design purpose are the prediction of pre-chill time, loading time, amount of fuel lost, the maximum pressure rise etc. The physics involved for mathematical modeling is quite complex due to the fact the process is unsteady, there is phase change as some of the fuel changes from liquid to gas state, then conjugate heat transfer in the pipe walls as well as between solid-to-fluid region. The simulation is very tedious and time consuming too. So overall, this is a complex system and the objective of the work is student's involvement and work in the parametric study and optimization of numerical modeling towards the design of such system. The students have to first become familiar and understand the physical process, the related mathematics and the numerical algorithm. The work involves exploring (i) improved algorithm to make the transient simulation computationally effective (reduced CPU time) and (ii) Parametric study to evaluate design parameters by changing the operational conditions

Bandyopadhyay, Alak↗

Vibration Isolation for Launch of a Space Station Orbital Replacement Unit

Delivery of Orbital Replacement Units (ORUs) to on-orbit destinations such a the International Space Station (ISS) and the Hubble Space Telescope is an important component of the space program. ORUs are integrated on orbit with space assets to maintain and upgrade functionality. For ORUs comprised of sensitive equipment, the dynamic launch environment drives design and testing requirements, and high frequency random vibrations are generally the cause for failure. Vibration isolation can mitigate the structure-borne vibration environment during launch, and hardware has been developed that can provide a reduced environment for current and future launch environments. Random vibration testing of one ORU to equivalent Space Shuttle launch levels revealed that its qualification and acceptance requirements were exceeded. An isolation system was designed to mitigate the structure-borne launch vibration environment. To protect this ORU, the random vibration levels at 50 Hz must be attenuated by a factor of two and those at higher frequencies even more. Design load factors for Shuttle launch are high, so a metallic load path is needed to maintain strength margins. Isolation system design was performed using a finite element model of the ORU on its carrier with representative disturbance inputs. Iterations on the modelled to an optimized design based on flight proven SoftRide MultiFlex isolators. Component testing has been performed on prototype isolators to validate analytical predictions.

Maly, Joseph R.↗