Search NASA⌕ Search

SEARCH · Search NASA

Results for “Determination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Chelation ion chromatography as an automated, and cost-effective analytical technique for REE determination: method development and applications

Rare earth elements (REEs), as critical minerals, have important uses in modern energy and technologies, yet are vulnerable to potential supply chain disruptions. To establish domestic REE supply chain, efficient REE detection methods for resource characterization and mineral processing will be needed to accelerate innovations for domestic REE recovery. This study developed a rapid, novel, and cost-effective for REE detection method using ion chromatography (IC) for aqueous samples. Various REE-targeted eluent gradients and post-column agent compositions were tested on the chelation ion chromatography (CIC) with UV-vis detector for optimal separation and quantification of REEs within approximately 20 min. The single-channel pump to deliver the post-column solution to UV-vis detector was replaced with a 4-channel gradient pump, to increase operation and maintenance efficiencies. After method optimization, resulting calibration curves for more than ten REEs achieved high coefficients of determination (R2>0.999) and low relatively standard deviations (below 3.24%), demonstrating sub-ppm level detection limits (0.0897 to 0.1149 mg/L). The reliability of the CIC method was validated through comparison with inductively coupled plasma mass spectrometry (ICP-MS), showing strong agreement in REE recovery from certified standards. The impact of metal ions and salts on REE recovery using CIC was also systematically investigated. CIC consistently exhibited reliable performance in the presence of salt solutions such as NaCl and Na₂SO₄ (up to 10,000 mg/L). Our study also found the presence of high concentrations of Al ions (at 10,000 mg/L) significantly influenced REE determination, and elevated concentrations of Ca ions affected the recovery of specific REEs, including La, Ce, and Pr. The CIC method was further tested on REE-containing eluents from solvent extraction tests out of fly ash leachates. REE detection from these real processing fluids were reported to achieve 90% to 100% recovery rate from our IC method, compared to ICP-MS results. This study underscores the potential of CIC as a reliable and efficient alternative for REE determination in complex matrices. It also highlights the importance of minimizing select interfering metal ions in solutions to ensure accurate results. The REE CIC method presents a promising, low-maintenance, salt-tolerant, and cost-effective alternative to traditional analytical methods for REE analysis.

detection of rare earth elements (REE)↗

Preliminary Insights Into the Feasibility of Determining the Purification Date of Enriched Uranium by Direct Measurement of the 230 Th/ 234 U Ratio Using an All-Faraday Detector Configuration on the Neoma MC-ICP-MS

Rationale: Mass spectrometric measurement of the 230 Th/ 234 U ratio to calculate the purification age of enriched uranium is typically conducted via a combination of ion counters and faraday detectors, thus requiring an inter-detector calibration scheme. Here, our aim is to understand whether the pursuit of a simplified measurement scheme involving only faraday detectors is feasible. Methods: We investigate the possibility of determining U-Th model ages for two enriched uranium standards (NBL U630 and U850) by direct measurement of the 230 Th/ 234 U ratio (without chromatographic separation or isotope dilution) on a ThermoFisher Scientific Neoma MC-ICP-MS utilizing both solution and laser ablation (LA)-based sampling techniques and an all-faraday detector configuration. Results: For the solution mode analyses conducted on aliquots containing sub μg/mL total U, we produce composite average 230 Th/ 234 U model dates of May 19, 1988 (± 351 days), and March 26, 1961 (± 2.5 years) using the directly measured 230 Th/ 234 U ratios for the NBL U630 and U850 uranium standards, which have certified purification dates of June 6, 1988 (± 190 days), and December 31, 1957 (± 36.5 days), respectively. The ages produced by LA-based sampling of dried residues of the same standards deposited onto cotton TexWipes are less accurate and of poorer precision (June 23, 2004 ± 8.7 years for U630 and December 21, 1965 ± 7.9 years for U850) but still yield meaningful information in regards to the purification date. Conclusions: We believe that further refinement of the all faraday detector measurement approach to include development of a more robust Th/U relative sensitivity factor determination, signal cutoff selection, and data processing protocols will allow for this approach to be confidently applied to enriched uranium materials with unknown purification histories. Potential advantages of the method include the reduced sample handling and infrastructure requirements as well as the ability to simultaneously generate a broad picture of the uranium isotopic composition in tandem with the U-Th age determination.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Charge Carrier Lifetime Determination in Graded Absorber Solar Cells Using Time‐Resolved Photoluminescence Simulations and Measurements

Thin‐film photovoltaic device efficiencies are limited by carrier recombination, thus understanding recombination mechanisms is critical for performance improvements. Bulk minority carrier lifetime ( τ bulk ) is a critical parameter for solar cells but is difficult to determine in P–N junction devices, especially for high doping. As doping ≥10 16 cm −3 is required for efficient drift‐charge‐carrier‐collection devices, a method for τ bulk determination in doped P–N junction devices is necessary. This work utilizes time‐resolved photoluminescence (TRPL) simulations to quantify bulk and interface recombination properties in highly doped, graded absorber CdSeTe structures. The two methods developed here for τ bulk determination include utilization of an instantaneous lifetime representation to guide TRPL fitting and direct comparison between measured and simulated decays. Simulations verified that both methods are valid for state‐of‐the‐art device architectures which include graded bandgap absorbers, graded doping, and graded lifetimes. Shifts in the dominant recombination mechanism are identified for sufficiently long τ bulk , where front and back interface quality plays a more prominent role. Evaluation of surface recombination velocities and conduction band offset illustrate electro‐optical advantages of a positive conduction band offset and highlight the necessity of improved interfaces as bulk quality in photovoltaic devices improves.

14 SOLAR ENERGY↗

Determining P, S, Br, and I content in uranium by triple quadrupole inductively coupled plasma mass spectrometry

The trace impurities of a uranium ore concentrate (UOC) can be examined to determine mine source, methods of production, and quality. This study presents a method to determine the concentration of halides and main group elements, specifically P, S, Br and I, utilizing triple quadrupole inductively coupled plasma–mass spectrometry. These analytes were measured in a uranium matrix to simulate a UOC sample. The concentrations determined with this method showed agreement with known values. Solutions with and without uranium were compared. A UOC certified reference material, CUP-2, was analyzed to further demonstrate the effectiveness of the method.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Distributed non-negative matrix factorization with determination of the number of latent features

The holistic analysis and understanding of the latent (that is, not directly observable) variables and patterns buried in large datasets is crucial for data-driven science, decision making and emergency response. Such exploratory analyses require devising unsupervised learning methods for data mining and extraction of the latent features, and non-negative matrix factorization (NMF) is one of the prominent such methods. NMF is based on compute-intense non-convex constrained minimization, which, for large datasets requires fast and distributed algorithms. However, current parallel implementations of NMF fail to estimate the number of latent features. In practice, identifying these features is both difficult and significant for pattern recognition and latent feature analysis, especially for large dense matrices. Here, we introduce a distributed NMF algorithm coupled with distributed custom clustering followed by a stability analysis on dense data, which we call DnMFk, to determine the number of latent variables. The results on synthetic data and the classical Swimmer data set demonstrate the accuracy of model determination while scaling nearly linearly across multiple processors for large data. Further, we employ DnMFk to determine the number of hidden features from a terabyte matrix.

97 MATHEMATICS AND COMPUTING↗

What are the current limits on determination of protonation state using neutron macromolecular crystallography?

The rate of deposition of models determined by neutron diffraction, or a hybrid approach that combines X-ray and neutron diffraction, has increased in recent years. The benefit of neutron diffraction is that hydrogen atom (H) positions are detectable, allowing for the determination of protonation state and water molecule orientation. This study analyses all neutron models deposited in the Protein Data Bank to date, focusing on protonation state and properties of H (or deuterium, D) atoms as well as the details of water molecules. In particular, clashes and hydrogen bonds involving H or D atoms are investigated. As water molecules are typically the least reproducible part of a structural model, their positions in neutron models were compared to those in homologous high-resolution X-ray structures. For models determined by joint refinement against X-ray and neutron data, the water structure comparison was also carried out for models re-refined against the X-ray data alone. The homologues have generally fewer conserved water molecules where X-ray only was used and the positions of equivalent waters vary more than in the case of the hybrid X-ray model. As neutron diffraction data are generally less complete than X-ray data, the influence of neutron data completeness on nuclear density maps was also analyzed. Here, we observe and discuss systematic map quality deterioration as result of data incompleteness.

Hydrogen bond↗

Rapid determination of supercritical CO 2 and brine relative permeability using an unsteady-state flow method

In this study, relative permeability of supercritical CO 2 (scCO 2 ) and brine was determined in reactive and non-reactive rock cores using a combination of unsteady-state methodology and computed tomography. Experiments were conducted using a medical grade CT scanner to determine saturation using a custom Python script. The saturation and differential pressure across the core were then used to derive four empirical constants to calculate relative permeability. This methodology increases temporal efficiency while reducing experimental complexity. Additionally, we show that the method can be used to determine scCO 2 relative permeability in a wide range of lithologies and flow rates, and with the ability to account for matrix dissolution during scCO 2 flooding.

54 ENVIRONMENTAL SCIENCES↗

Determination of the 161 Tb half-life

There is significant interest in the use of terbium radioisotopes for applications in cancer therapy and diagnosis. Of these, 161 Tb, a medium energy beta- and prolific auger emitter, is being investigated as a potential alternative to 177 Lu. The higher proportion of conversion electron and Auger electron emissions, and variety of low-energy gammas make 161 Tb an attractive targeted theranostic. As a product of nuclear fission, 161 Tb is also of importance to nuclear forensics. The current evaluated half-life of 6.89(2) d has a standard uncertainty that contributes significantly to the standard uncertainty of decay calculated activity determination. Furthermore, the accuracy of this evaluated half-life has been called into question by measurements reported recently at the Institute of Radiation Physics (IRP), Switzerland. In this work, the half-life of 161 Tb was measured at three independent laboratories located in the United Kingdom and United States of America for a total of five determinations using three independent measurement techniques. In conclusion, the half-life determined for 161 Tb of 6.9637(29) d confirms the observed 1 % relative increase observed by IRP, though the reported half-lives in this work and at IRP are significantly different (ζ-score = 3.1).

half-life↗

Accurate activity determination of a californium neutron source

Accurately counting analog events requires constructing an electronics chain that produces one count for each input pulse. Here, in this work, we review the use of Nuclear Instrumentation Module electronic units for counting neutron capture events in a 3He tube. We identify two unique types of false trigger events in a leading-edge discriminator and show how a dual timer module can be used to produce a veto window to exclude these events. We use the constructed electronics chain to build an apparatus to measure neutron pulses from a 252 Cf neutron source. We compare the measurements with a Monte Carlo N-Particle (MCNP) model to determine the activity of the neutron source. Furthermore, by making additional measurements with borated polyethylene attenuators between the source and detector, we are able to determine the boron concentration of the polyethylene. This technique provides accurate determination of the source activity to a precision of 2.8% at the k=1 level. The method used is simple, inexpensive, and requires no additional calibrated instruments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Influence of cementation on the yield surface of rocks numerically determined from digital microstructures

Digital Rock Physics has reached a level of maturity on the characterisation of primary properties that depend on the microstructure – such as porosity, permeability or elastic moduli – by numerically solving field equations on μCT scan images of rock. After small deformations or at depth though, most rocks eventually reach their limit of elasticity and the complementary plastic properties are needed to describe the full mechanical behaviour. Currently, determination of a rock’s yield surface from its microstructure is often restricted to semi-analytical criteria derived by limit analysis or numerical simulations performed on idealised geometries. Such simplification lacks representativeness, particularly for processes that affect directly the pore-grain interface such as the cementation phenomenon, happening during diagenesis. Eventually, only direct numerical simulation of elasto-plasticity performed on digitalised microstructures can be used to assess the strength of different cemented materials and its evolution with the alteration of the microstructure. In this study, we provide a comprehensive parametric study on the impact of cementation on rock strength for real microstructures of cemented granular materials. Compared to most previous studies, the whole yield surface is determined numerically (using Finite Element Method) in order to assess the influence of cementation for different stress-paths. The previously known tendency of rock to strengthen with increasing cementation volume is verified. New results on the influence of cement property namely Young’s modulus, friction and cohesion on the rock’s yield surface are explored. The envelopes obtained are compared to the ones obtained by experimental data and existing models. Finally, the framework presented in this study showcases the wider possibility of determining any rock’s or porous material’s yield surface from its microstructure.

36 MATERIALS SCIENCE↗

Evaluation of the ring tension test (RTT) for robust determination of material strengths

The ring tension test (RTT) is an experimental method for determining mechanical behavior in a material’s circumferential or hoop direction. It is a crucial test for testing anisotropic materials with tube geometry, such as nuclear fuel cladding or irradiated pipes. Several RTT configurations exist, each with their own advantages and disadvantages. However, this test is significantly more complex than traditional tensile testing and can be especially sensitive to small differences and inconsistencies in the test setup and geometry, ultimately affecting the derived mechanical properties. Previous research has focused on method development, and little work has been done on understanding the subtle differences between an ideal test and experiments, specifically when the tests are performed on highly irradiated materials in hot cells. In this work, a finite element-based investigation of the RTT is conducted to fill this gap. The two most used test configurations are investigated, comparing their ability to determine accurate material strengths through plastic deformation. Several non-ideal conditions and uncontrollable effects which are likely to occur during experimental testing such as machining tolerances, variations of specimen geometry from nominal dimensions, rotation of specimens and fixturing, and other test setup discrepancies are studied. The sensitivity of measured strengths to these conditions is presented. A mechanics-based approach to describing and correcting raw data to determine actual strengths is also included for one of the configurations, resulting in a robust correction method with highly accurate material strength measurements. Finally, based on these analyses, the hemicylindrical mandrel configuration is recommended with a gauge region oriented at a 45° angle.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Determination of neutron irradiation temperatures of SiC using electrical resistivity method

The irradiation temperature of silicon carbide (SiC) was determined post-irradiation by examination of the recovery of the electrical resistivity due to thermal annealing in a rapid heating/cooling optical furnace. High-purity, high-resistivity grade SiC is routinely used as a passive temperature monitor in neutron irradiation studies at the High Flux Isotope Reactor (HFIR), and this paper presents an alternative automated technique for determination of the irradiation temperature the SiC experienced. Neutron collisions with the atoms results in displaced lattice atoms (interstitials) that act as electron donors yielding a significant decrease in electrical resistivity. The irradiation defects become thermodynamically unstable and start to recombine, when annealed above the irradiation temperature, resulting in a recovery of the electrical resistivity. The resistivity is measured at a fixed elevated temperature above ambient, which is below the target irradiation temperature. When the resistivity is plotted as a function of annealing temperatures, a clear increase is observed due to the recovery of irradiation defects. We have demonstrated that this electrical resistivity measurement of SiC is effective to determine irradiation temperature of SiC. In conclusion, energy levels of various defects in SiC were calculated from Arrhenius plots of electrical conductivity versus inverse temperature.

36 MATERIALS SCIENCE↗

Accurate determination of the electron spin polarization in magnetized iron and nickel foils for Møller polarimetry

The Møller polarimeter in Hall A at Jefferson Lab in Newport News, VA, has provided reliable measurements of electron beam polarization for the past two decades. Past experiments have typically required polarimetry at the 1% level of absolute uncertainty which the Møller polarimeter has delivered. However, the upcoming proposed experimental program including MOLLER and SoLID have stringent requirements on beam polarimetry precision at the level of 0.4% (The MOLLER Collaboration, 2014; The SoLID collaboration, 2019), requiring a systematic re-examination of all the contributing uncertainties. Møller polarimetry uses the double polarized scattering asymmetry of a polarized electron beam on a target with polarized atomic electrons. The target is a ferromagnetic material magnetized to align the spins in a given direction. In Hall A, the target is a pure iron foil aligned perpendicular to the beam and magnetized out of plane parallel or antiparallel to the beam direction. The acceptance of the detector is engineered to collect scattered electrons close to 90° in the center of mass frame where the analyzing power is a maximum (-7/9). One of the leading systematic errors comes from determination of the target foil polarization. Polarization of a magnetically saturated target foil requires knowledge of both the saturation magnetization and g', the electron g-factor which includes components from both spin and orbital angular momentum from which the spin fraction of magnetization is determined. Target foil polarization has been previously addressed in a 1997 publication “A precise target for Møller polarimetry” by de Bever et al. (1997) at a level of precision sufficient for experiments up to this point. Several shortcomings with the previous published value require revisiting the result prior to MOLLER. Here, we utilize the existing world data to provide a best estimate for target polarization for both nickel and iron foils including uncertainties in magnetization, high-field and temperature dependence, and fractional contribution to magnetization from orbital effects. We determine the foil electron spin polarization at 294 K to be 0.08020 ± 0.00018 (@4 T applied field) for iron and 0.018845+/-0.000053 (@2 T applied field) for nickel. Finally, we conclude with a brief discussion of additional systematic uncertainties to Møller polarimetry using this technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental determination of critical resolved shear stress for strain-induced phase transformation

The current investigation reports the first attempt to measure the critical resolved shear stress to initiates strain-induced phase transformation in a three-dimensional polycrystalline aggregate using high-energy diffraction microscopy (HEDM). In situ tensile testing was performed on a Fe38.5Mn20Co20Cr15Si5Cu1.5 metastable alloy exhibiting transformation-induced plasticity (TRIP). Grains with a higher propensity for strain-induced phase transformation were tracked using HEDM. A sharp drop in grain specific stress, coinciding with the appearance of a new ε-hcp grain oriented relative to the parent γ-fcc phase, was taken as evidence of grain-specific stress required to trigger phase transformation. The highest resolved shear stress on the potential transformation systems was identified as the critical resolved shear stress (CRSS) for strain-induced phase transformation. For the studied metastable alloy, CRSS for transformation was determined to be 86±3 MPa which was very close to theoretical CRSS value determined using Schmid factor (89±12 MPa) compared to the value determined using Taylor factor (62±7 MPa).

Jain, Roopam↗

Alpha Shape Analysis (ASA) Framework for Post- Clustering Property Determination in Atom Probe Tomographic Data

While application of clustering algorithms to atom probe tomography data have enabled quantification of solute clusters in terms of number density, size, and subcomposition there exist other properties (e.g., volume, surface area, and composition) that are better determined by defining an interface between the cluster and the surrounding matrix. The limitation in composition results from an ion selection step where the expected matrix ion types are omitted from the cluster search algorithm to enhance the contrast between the matrix and cluster and to reduce the complexity of the search. Previously, composition determination within solute clusters has utilized a secondary envelopment and erosion step on top of conventional methods such as maximum separation. In this work, we present a novel stochastic method that combines the particle identification fidelity of a conventional clustering algorithm with the analytical flexibility of mesh-based approaches through the generation of alpha shapes for each identified cluster. Furthermore, the corresponding mesh accounts for concave components of the clusters and determines the volume and surface area of the clusters; additionally, the mesh boundary is utilized to update the total composition according to the internal ions.

42 ENGINEERING↗

Rapid Determination of Uranium Isotopic Abundance from Cotton Swipes: Direct Extraction via a Planar Surface Reader and Coupling to a Microplasma Ionization Source

The collection of solid particulates and liquids from surfaces by the use of cloth swipes is fairly ubiquitous. In such methods, there is a continuous concern regarding the ability to locate and quantitatively sample the analyte species from the material. In this effort, we demonstrate the initial coupling of an Advion Plate Express plate reader to a liquid sampling–atmospheric pressure glow discharge (LS-APGD) microplasma ionization source with an Orbitrap mass spectrometer to perform uranium isotopic analyses of solution residues on cotton swipes. The Plate Express employs a sampling probe head to engage and seal against the swipe surface. Subsequentially, the analyte residues are desorbed and transported within a 2% HNO 3 electrolyte flow to the ionization source. Quantitative recoveries were observed following a single 30 s extraction step, with the absolute mass sampled per extraction being ~100 ng. While the intrasample variability in the analytical responses for triplicate sampling of the same swipe yield ~30% RSD, this lack of precision is offset by the ability to determine isotope ratios for enriched uranium specimens with a precision of better than 10% RSD. Pooled, intersample precision ( n = 9) was found to be <5%RSD across the various sample compositions. Finally, 235 U/ 238 U determinations (ranging from 0.053 to 1.806) were accurate with errors of <10%, absolute. The 234 U- and 236 U-inclusive ratios were determined with similar accuracy in enriched samples. While the driving force for the effort is in the realm of nuclear nonproliferation efforts, the ubiquitous use of cloth swipes across many application areas could benefit from this convenient approach, including the use of versatile, reduced-format mass spectrometer systems.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Determining the N -Representability of a Reduced Density Matrix via Unitary Evolution and Stochastic Sampling

The N-representability problem consists in determining whether, for a given p-body matrix, there exists at least one N-body density matrix from which the p-body matrix can be obtained by contraction, that is, if the given matrix is a p-body reduced density matrix (p-RDM). The knowledge of all necessary and sufficient conditions for a p-body matrix to be N-representable allows the constrained minimization of a many-body Hamiltonian expectation value with respect to the p-body density matrix and, thus, the determination of its exact ground state. However, the number of constraints that complete the N-representability conditions grows exponentially with system size, and hence, the procedure quickly becomes intractable for practical applications. This work introduces a hybrid quantum-stochastic algorithm to effectively replace the N-representability conditions. The algorithm consists of applying to an initial N-body density matrix a sequence of unitary evolution operators constructed from a stochastic process that successively approaches the reduced state of the density matrix on a p-body subsystem, represented by a p-RDM, to a target p-body matrix, potentially a p-RDM. The generators of the evolution operators follow the well-known adaptive derivative-assembled pseudo-Trotter method (ADAPT), while the stochastic component is implemented by using a simulated annealing process. The resulting algorithm is independent of any underlying Hamiltonian, and it can be used to decide whether a given p-body matrix is N-representable, establishing a criterion to determine its quality and correcting it. We apply the proposed hybrid ADAPT algorithm to alleged reduced density matrices from a quantum chemistry electronic Hamiltonian, from the reduced Bardeen–Cooper–Schrieffer model with constant pairing, and from the Heisenberg XXZ spin model. In all cases, the proposed method behaves as expected for 1-RDMs and 2-RDMs, evolving the initial matrices toward different targets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular Structure of Sphingomyelin in Fluid Phase Bilayers Determined by the Joint Analysis of Small-Angle Neutron and X-ray Scattering Data

In this work, we have determined the fluid bilayer structure of palmitoyl sphingomyelin (PSM) and stearoyl sphingomyelin (SSM) by simultaneously analyzing small-angle neutron and X-ray scattering data. Using a newly developed scattering density profile (SDP) model for sphingomyelin lipids, we report structural parameters including the area per lipid, total bilayer thickness, and hydrocarbon thickness, in addition to lipid volumes determined by densitometry. Unconstrained all-atom simulations of PSM bilayers at 55 °C using the C36 CHARMM force field produced a lipid area of 56 Å 2 , a value that is 10% lower than the one determined experimentally by SDP analysis (61.9 Å2). Furthermore, scattering form factors calculated from the unconstrained simulations were in poor agreement with experimental form factors, even though segmental order parameter (S CD ) profiles calculated from the simulations were in relatively good agreement with S CD profiles obtained from NMR experiments. Conversely, constrained area simulations at 61.9 Å 2 resulted in good agreement between the simulation and experimental scattering form factors, but not with S CD profiles from NMR. We discuss possible reasons for the discrepancies between these two types of data that are frequently used as validation metrics for molecular dynamics force fields.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗