Dynamic diffraction artefacts in Bragg coherent diffractive imaging

This article reports a theoretical study on the reconstruction artefacts in Bragg coherent diffractive imaging caused by dynamical diffraction effects. It is shown that, unlike the absorption and refraction effects that can be corrected after reconstruction, dynamical diffraction effects have profound impacts on both the amplitude and the phase of the reconstructed complex object, causing strong artefacts. At the dynamical diffraction limit, the reconstructed shape is no longer correct, as a result of the strong extinction effect. Simulations for hemispherical particles of different sizes show the type, magnitude and extent of the dynamical diffraction artefacts, as well as the conditions under which they are negligible.

36 MATERIALS SCIENCE↗

X-ray Laue micro diffraction and neutron diffraction analysis of residual elastic strains and plastic deformation in a 1% uniaxial tensile tested nickel alloy 600 sample

The magnitude and distribution of elastic strain for a nickel alloy 600 (A600) sample that had been subjected to uniaxial tensile stress were measured by micro Laue diffraction (MLD) and neutron diffraction techniques. For a sample that had been dimensionally strained by 1%, both MLD and neutron diffraction data indicated that the global residual elastic strain was on the order of 10{sup -4}, however the micro-diffraction data indicated considerable grain-to-grain variability amongst individual components of the residual strain tensor. A more precise comparison was done by finding those grains in the MLD map that had appropriate <hkl> oriented in the specific directions matching those used in the neutron measurements and the strains were found to agree within the uncertainty. Large variations in strain values across the grains were noted during the MLD measurements which are reflected in the uncertainties. This is a possible explanation for the large uncertainty in the average strains measured from multiple grains during neutron diffraction.

36 MATERIALS SCIENCE↗

Hydrogen in polar intermetallics: Syntheses and structures of the ternary Ca{sub 5}Bi{sub 3}D{sub 0.93}, Yb{sub 5}Bi{sub 3}H{sub x}, and Sm{sub 5}Bi{sub 3}H{sub a}pprox{sub 1} by powder neutron or single crystal X-ray diffraction

The syntheses of the title compounds are described in detail. Structural characterizations from refinements of single crystal X-ray diffraction data for Yb{sub 5}Bi{sub 3}H{sub x} and Sm{sub 5}Bi{sub 3}H{sub a}pprox{sub 1} and of powder neutron diffraction data for Ca{sub 5}Bi{sub 3}D{sub 0.93(3)} are reported. These confirm that all three crystallize with the heavy atom structure type of beta-Yb{sub 5}Sb{sub 3}, and the third gives the first proof that the deuterium lies in the center of nominal calcium tetrahedra, isostructural with the Ca{sub 5}Sb{sub 3}F-type structure. These Ca and Yb phases are particularly stable with respect to dissociation to Mn{sub 5}Si{sub 3}-type product plus H{sub 2}. Some contradictions in the literature regarding Yb{sub 5}Sb{sub 3} and Yb{sub 5}Sb{sub 3}H{sub x} phases are considered in terms of adventitious hydrogen impurities that are generated during reactions in fused silica containers at elevated temperatures. - Graphical abstract: The structure of Ca{sub 5}Bi{sub 3}H{sub 0.93} occurs in the novel Ca{sub 5}Sb{sub 3}F structure type with D centered in the shaded calcium tetrahedra.

36 MATERIALS SCIENCE↗

High-Pressure Neutron Diffraction Study on H-D Isotope Effects in Brucite

A neutron powder diffraction study of hydrogenated and deuterated brucite was conducted at ambient temperature and at pressures to 9 GPa, using a Paris-Edinburgh high-pressure cell at the WAND instrument of ORNL High Flux Isotope Reactor. The two materials were synthesized by the same method and companion measurements of neutron diffraction were conducted under the same conditions. Our refinement results show that the lattice-parameters of the a axis, parallel to the sheets of Mg-O octahedra, decreases only slightly with pressure with no effect of H-D substitution. However, the c axis of Mg(OD)2 is shorter and decreases more rapidly than that of Mg(OH)2 with increasing pressure. Consequently, the unit-cell volume of deuterated brucite is slightly, but systematically smaller than that of normal brucite, which were fitted to third-order Birch-Murnaghan equation: K0=41.46 0.52 and 39.04 0.30 GPa for Mg(OH)2 and Mg(OD)2, respectively with a fixed K0 value of 10. Our results suggest that H-D substitution of brucite and other hydrous minerals with H-bonding likely influences their structural and dynamic properties under pressure, including the position of hydrogen atoms. The measured effect of H-D substitution on the unit-cell volume also demonstrates that brucite (and other hydrous minerals) preferentially incorporate deuterium over hydrogen under pressure, suggesting that the distribution of hydrogen isotopes in deep-earth conditions may differ significantly from that in near-surface environments.

08 HYDROGEN↗

Combining X-ray Absorption and X-ray Diffraction Techniques for in Situ Studies of Chemical Transformations in Heterogeneous Catalysis:Advantages and Limitations

Recent advances in catalysis instrumentations include synchrotron-based facilities where time-resolved X-ray scattering and absorption techniques are combined in the same in situ or operando experiment to study catalysts at work. To evaluate the advances and limitations of this method, we performed a series of experiments at the new XAFS/XRD instrument in the National Synchrotron Light Source. Nearly simultaneous X-ray diffraction (XRD) and X-ray absorption fine-structure (XAFS) measurements of structure and kinetics of several catalysts under reducing or oxidizing conditions have been performed and carefully analyzed. For CuFe{sub 2}O{sub 4} under reducing conditions, the combined use of the two techniques allowed us to obtain accurate data on kinetics of nucleation and growth of metallic Cu. For the inverse catalyst CuO/CeO{sub 2} that underwent isothermal reduction (with CO) and oxidation (with O{sub 2}), the XAFS data measured in the same experiment with XRD revealed strongly disordered Cu species that went undetected by diffraction. These and other examples emphasize the unique sensitivity of these two complementary methods to follow catalytic processes in the broad ranges of length and time scales.

43 PARTICLE ACCELERATORS↗

Time-Resolved Synchrotron X-ray Diffraction on Pulse Laser Heated Iron in Diamond Anvil Cell

We present time-resolved synchrotron x-ray diffraction to probe the {epsilon}-{delta} phase transition of iron during pulse-laser heating in a diamond anvil cell. The system utilizes a monochromatic synchrotron x-ray beam, a two-dimensional pixel array x-ray detector and a dual beam, double side laser-heating system. Multiple frames of the diffraction images are obtained in real-time every 22 ms over 500 ms of the entire pulse heating period. The results show the structural evolution of iron phases at 17 GPa, resulting in thermal expansion coefficient 1/V({Delta}V/{Delta}T){sub p} = 7.1 x 10{sup -6}/K for {epsilon}-Fe and 2.4 x 10{sup -5}/K for {gamma}-Fe, as well as the evidence for metastability of {gamma}-Fe at low temperatures below the {epsilon}-{gamma} phase boundary.

36 MATERIALS SCIENCE↗

X-ray back-diffraction: can we further increase the energy resolution by tuning the energy slightly below that of exact backscattering?

X-ray beams at energies tuned slightly below that of exact backscattering (extreme conditions, where X-ray back-diffraction is almost extinguished - called residual XBD) are better focused if the experiment is carried out at lower energies in order to avoid multiple-beam diffraction effects. Following previous work by the authors [Honnicke, Conley, Cusatis, Kakuno, Zhou, Bouet, Marques & Vicentin (2014). J. Appl. Cryst.47, 1658-1665], herein efforts are directed towards characterizing the residual XBD beam of an ultra-thin Si 220 crystal (UTSiXTAL) at similar to 3.2 keV. To achieve the residual XBD condition the UTSiXTAL was cooled from 310 to 273 K. The results indicate that under this extreme condition the energy resolution can be further improved. Issues with the energy resolution measurements due to incoming beam divergence and the ultra-thin crystal flatness are discussed.

low-energy X-ray back-diffraction↗

Electron diffraction of CBr{sub 4} in superfluid helium droplets: A step towards single molecule diffraction

We demonstrate the practicality of electron diffraction of single molecules inside superfluid helium droplets using CBr{sub 4} as a testing case. By reducing the background from pure undoped droplets via multiple doping, with small corrections for dimers and trimers, clearly resolved diffraction rings of CBr{sub 4} similar to those of gas phase molecules can be observed. The experimental data from CBr{sub 4} doped droplets are in agreement with both theoretical calculations and with experimental results of gaseous species. The abundance of monomers and clusters in the droplet beam also qualitatively agrees with the Poisson statistics. Possible extensions of this approach to macromolecular ions will also be discussed. This result marks the first step in building a molecular goniometer using superfluid helium droplet cooling and field induced orientation. The superior cooling effect of helium droplets is ideal for field induced orientation, but the diffraction background from helium is a concern. This work addresses this background issue and identifies a possible solution. Accumulation of diffraction images only becomes meaningful when all images are produced from molecules oriented in the same direction, and hence a molecular goniometer is a crucial technology for serial diffraction of single molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Novel diamond cells for neutron diffraction using multi-carat CVD anvils

Traditionally, neutron diffraction at high pressure has been severely limited in pressure because low neutron flux required large sample volumes and therefore large volume presses. At the high-flux Spallation Neutron Source at the Oak Ridge National Laboratory, we have developed in this paper new, large-volume diamond anvil cells for neutron diffraction. The main features of these cells are multi-carat, single crystal chemical vapor deposition diamonds, very large diffraction apertures, and gas membranes to accommodate pressure stability, especially upon cooling. A new cell has been tested for diffraction up to 40 GPa with an unprecedented sample volume of ~0.15 mm 3 . High quality spectra were obtained in 1 h for crystalline Ni and in ~8 h for disordered glassy carbon. Finally, these new techniques will open the way for routine megabar neutron diffraction experiments.

47 OTHER INSTRUMENTATION↗

Extending the limits of powder diffraction analysis: diffraction parameter space, occupancy defects, and atomic form factors

Although the determination of site occupancies is often a major goal in Rietveld refinement studies, the accurate refinement of site occupancies is exceptionally challenging due to the many correlations and systematic errors that have a hidden impact on the final refined occupancy parameters. Through the comparison of results independently obtained from neutron and synchrotron powder diffraction, improved approaches capable of detecting occupancy defects with an exceptional sensitivity of 0.1% (absolute) in the class of layered NMC Li-ion battery cathode materials have been developed. A new method of visualizing the diffraction parameter space associated with crystallographic site scattering power through the use of f* diagrams is described and this method is broadly applicable to ternary compounds. The f* diagrams allow the global minimum fit to be easily identified and also permit a robust determination of the number and type of occupancy defects within a structure. Through a comparison of neutron and X-ray diffraction results, a systematic error in the synchrotron results was identified using f* diagrams for a series of NMC compounds. Using neutron diffraction data as a reference, this error was shown to specifically result from problems associated with the neutral oxygen X-ray atomic form factor and could be eliminated by using the ionic O 2- form factor for this anion while retaining the neutral form factors for cationic species. The f* diagram method offers a new opportunity to experimentally assess the quality of atomic form factors through powder diffraction studies on chemically related multi-component compounds.

25 ENERGY STORAGE↗

Robust structural analysis of native biological macromolecules from multi-crystal anomalous diffraction data

Anomalous diffraction signals from typical native macromolecules are very weak, frustrating their use in structure determination. Here, native SAD procedures are described for enhancing the signal to noise in anomalous diffraction by using multiple crystals are described. Five applications demonstrate that truly routine structure determination is possible without the need for heavy atoms. Structure determinations for biological macromolecules that have no known structural antecedents typically involve the incorporation of heavier atoms than those found natively in biological molecules. Currently, selenomethionyl proteins analyzed using single- or multi-wavelength anomalous diffraction (SAD or MAD) data predominate for such de novo analyses. Naturally occurring metal ions such as zinc or iron often suffice in MAD or SAD experiments, and sulfur SAD has been an option since it was first demonstrated using crambin 30 years ago; however, SAD analyses of structures containing only light atoms (Z{sub max} ≤ 20) have not been common. Here, robust procedures for enhancing the signal to noise in measurements of anomalous diffraction by combining data collected from several crystals at a lower than usual X-ray energy are described. This multi-crystal native SAD method was applied in five structure determinations, using between five and 13 crystals to determine substructures of between four and 52 anomalous scatterers (Z ≤ 20) and then the full structures ranging from 127 to 1200 ordered residues per asymmetric unit at resolutions from 2.3 to 2.8 Å. Tests were devised to assure that all of the crystals used were statistically equivalent. Elemental identities for Ca, Cl, S, P and Mg were proven by f′′ scattering-factor refinements. The procedures are robust, indicating that truly routine structure determination of typical native macromolecules is realised. Synchrotron beamlines that are optimized for low-energy X-ray diffraction measurements will facilitate such direct structural analysis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simultaneous sample and spatial coherence characterisation using diffractive imaging

We demonstrate an algorithm that reconstructs the complex transmission function of an object from experimental X-ray diffraction data using partially coherent 1.4 keV X-rays that does not require a priori input of the coherence function. The quality of the reconstruction is significantly better than that obtained by assuming that the illumination is fully coherent. Our approach can be readily applied to diffraction imaging problems where a model for the spatial coherence can be assumed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spatially resolved texture and microstructure evolution of additively manufactured and gas gun deformed 304L stainless steel investigated by neutron diffraction and electron backscatter diffraction

In this study, we report the characterization of a 304L stainless steel cylindrical projectile produced by additive manufacturing. The projectile was compressively deformed using a Taylor Anvil Gas Gun, leading to a huge strain gradient along the axis of the deformed cylinder. Spatially resolved neutron diffraction measurements on the HIgh Pressure Preferred Orientation time-of-flight diffractometer (HIPPO) and Spectrometer for Materials Research at Temperature and Stress diffractometer (SMARTS) beamlines at the Los Alamos Neutron Science CEnter (LANSCE) with Rietveld and single-peak analysis were used to quantitatively evaluate the volume fractions of the α, γ, and ε phases as well as residual strain and texture. The texture of the γ phase is consistent with uniaxial compression, while the α texture can be explained by the Kurdjumov–Sachs relationship from the γ texture after deformation. This indicates that the material first deformed in the γ phase and subsequently transformed at larger strains. The ε phase was only found in volumes close to the undeformed material with a texture connected to the γ texture by the Shoji–Nishiyama orientation relationship. This allows us to conclude that the ε phase occurs as an intermediate phase at lower strain, and is superseded by the α phase when strain increases further. Furthe, we found a proportionality between the root-mean-squared microstrain of the γ phase, dominated by the dislocation density, with the α volume fraction, consistent with strain-induced martensite α formation. In conclusion, knowledge of the sample volume with the ε phase from the neutron diffraction analysis allowed us to identify the ε phase by electron back scatter diffraction analysis, complementing the neutron diffraction analysis with characterization on the grain level.

304L stainless steel↗

Quantum-dot-array diffraction grating with single order diffraction property for soft x-ray region

A gold transmission grating is used routinely to disperse the x-ray spectrum at the Z soft x-ray facility to measure the spectrum and temporal history of the absolute soft x-ray power emitted from z-pinch and hohlraum radiation sources. A quantum-dot-array diffraction grating (QDADG) of 250 lines/mm for soft x-ray is designed and fabricated for the first time according to the principle of binary sinusoidal transmission grating. The diffraction efficiencies of the grating are measured in the 150-300 eV photon energy range on the Beamline 3W1B of Beijing Synchrotron Radiation Facility. This article describes the basic concept and calibration techniques and presents calibration results. It is shown that the 250 lines/mm QDADG can be used to disperse light without higher-order diffractions in soft x-ray range, and the diffraction efficiencies of this grating are nearly constant (about 25%), which is beneficial in the spectrum analysis.

43 PARTICLE ACCELERATORS↗

Quantitative measurement of phase variation amplitude of ultrasonic diffraction grating based on diffraction spectral analysis

A new method based on diffraction spectral analysis is proposed for the quantitative measurement of the phase variation amplitude of an ultrasonic diffraction grating. For a traveling wave, the phase variation amplitude of the grating depends on the intensity of the zeroth- and first-order diffraction waves. By contrast, for a standing wave, this amplitude depends on the intensity of the zeroth-, first-, and second-order diffraction waves. The proposed method is verified experimentally. The measured phase variation amplitude ranges from 0 to 2π, with a relative error of approximately 5%. A nearly linear relation exists between the phase variation amplitude and driving voltage. Our proposed method can also be applied to ordinary sinusoidal phase grating.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High pressure Laue diffraction and its application to study microstructural changes during the α → β phase transition in Si

Here, an approach using polychromatic x-ray Laue diffraction is described for studying pressure induced microstructural changes of materials under pressure. The advantages of this approach with respect to application of monochromatic x-ray diffraction and other techniques are discussed. Experiments to demonstrate the applications of the method have been performed on the α → β phase transition in Si at high pressures using a diamond anvil cell. We present the characterization of microstructures across the α–β phase transition, such as morphology of both the parent and product phases, relative orientation of single-crystals, and deviatoric strains. Subtle inhomogeneous strain of the single-crystal sample caused by lattice rotations becomes detectable with the approach.