Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diffractive optical elements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Predesign of diamond turned refractive/diffractive elements for IR objectives

Diffractive lenses have arrived. Literally hundreds of papers have been published and technology impact reports have been written about the exciting addition of a new tool for the lens designer. Sophisticated computer programs have been developed to aid in the optimization of these diffractive phase profiles for a wide variety of applications. Now, several fabrication methods are being pursued to produce these diffractive elements economically. The best known process is the etching of a multi-level relief grating, known as binary optics. This process uses sets of computer generated lithographic masks. Another, more recently developed method is Dry Photopolymer Embossing (DPE). This replication process uses master holograms. And now, diamond turning is being applied for the machining of these elements. Diamond turning is especially well suited for infrared optics. As any process has advantages and limitations, so has diamond turning. These advantages and limitations are discussed and general guidelines are presented to aid the designer and systems engineer in the project predesign stage.

Riedl, Max J.↗

Metrology Optical Power Budgeting in SIM Using Statistical Analysis Techniques

The Space Interferometry Mission (SIM) is a space-based stellar interferometry instrument, consisting of up to three interferometers, which will be capable of micro-arc second resolution. Alignment knowledge of the three interferometer baselines requires a three-dimensional, 14-leg truss with each leg being monitored by an external metrology gauge. In addition, each of the three interferometers requires an internal metrology gauge to monitor the optical path length differences between the two sides. Both external and internal metrology gauges are interferometry based, operating at a wavelength of 1319 nanometers. Each gauge has fiber inputs delivering measurement and local oscillator (LO) power, split into probe-LO and reference-LO beam pairs. These beams experience power loss due to a variety of mechanisms including, but not restricted to, design efficiency, material attenuation, element misalignment, diffraction, and coupling efficiency. Since the attenuation due to these sources may degrade over time, an accounting of the range of expected attenuation is needed so an optical power margin can be book kept. A method of statistical optical power analysis and budgeting, based on a technique developed for deep space RF telecommunications, is described in this paper and provides a numerical confidence level for having sufficient optical power relative to mission metrology performance requirements.

stellar interferometry↗

The Solar-B Mission

The Solar-B mission is a joint enterprise between Japan, the United States of America and the United Kingdom. The collaboration is led by ISAS, the Japanese Institute for Space and Astronautical Science (ISAS), NASA and PPARC (Particle Physics and Astrophysics Research Council) play supporting roles in the development of the scientific objectives and provision of the scientific instruments. The mission's primary objective is to conduct a systems study of the solar atmosphere through the acquisition of coordinated measurements of the photosphere, the transition region/low corona and the upper corona using three instruments: an optical telescope, an extreme ultraviolet imaging spectrometer and a soft x-ray telescope. Drs. Saku Tsuneta (NAOJ) and Alan Title (LMSAL) lead the optical imaging team. The optical telescope is a 50-cm aperture, diffraction limited, Gregorian. The focal plane package will record high resolution images, Dopplergrams, and vector magnetic fields on spatial scales dominated by elemental photospheric flux tubes, and over a field of view large enough to contain small active regions. Drs. Tetsuya Watanabe, Len Culhane (MSSL) and George Doschek (NRL) led the EUV imaging and spectroscopy team. The EUV telescope has a 15-cm primary mirror feeding a toroidal grating. The optics have multiplayer coatings which select two wavebands between 180-204 A and 250-290 A. Drs. Kiyoto Shibasaki (NAOJ) and Leon Golub (SAO) lead the X-ray imaging team. The x-ray telescope will provide full disk, soft x-ray images with twice the spatial resolution of the Yohkoh SXT and enhanced sensitivity to longer (>40 A) wavelengths. The launch of Solar-B, into a sun-synchronous orbit, is scheduled for August 2004. Solar-B is the second mission in the Sun-Earth Connection, Solar-Terrestrial Probe Program which is managed by the Goddard Space Flight Center. The Science Directorate of the Marshall Space Flight Center manages the Solar-B Project for the ST Probe Project Office. This paper discusses the objectives, specifications, and design of the scientific instruments as presented at the Preliminary Design Review held at MSFC in May 2000.

Davis, John M.↗

Methods of analyzing microsize particulate aerosols and contaminants.

Methods for analyzing atmospheric aerosols and particulate contaminants from natural and industrial sources are briefly described. Their development was spurred by interest in cosmic dust investigations. These methods make it possible to analyze individual particles ranging in size from 0.01 to 1000 microns for elemental and mineralogical content. The described methods include transmission electron microscopy, scanning electron microscopy, electron probe microanalysis, X-ray diffraction, optical mineralogy, and density measurement.

Blanchard, M. B.↗

Design and initial performance evaluation of a portable short wave infrared spectroradiometer

The design, initial calibration, and performance evaluations of a portable short wave infrared (SWIR) spectroradiometer are described. The spectroradiometer covers the range from 1.1 to 2.5 microns with a spectral resolution that may be varied from less than 10 nm to more than 100 nm. A single spectrum is acquired in about 2 sec. The SNR is about 230 at a wavelength of 2.2 microns for a Lambertian surface of 90-percent reflectance illuminated by the sun at normal incidence with 14.8-nm resolution, a 25 C background temperature, and no atmospheric attenuation. FOV-defining optics are coupled by a flexible fiber-optics bundle to the spectroradiometer, which consists of a concave holographic diffraction grating with a flat focal field imaged onto a 1024-element platinum silicide linear-array detector.

Smith, Mark W.↗

Phase chemistry of Apollo 14 soil sample 14259

Optical, X-ray-diffraction and electron-microprobe techniques were used to investigate 0.26 gm of Apollo 14 soil sample 14259. Major element microprobe analyses were made of 470 mineral grains and 388 glass grains. The mineral abundances in the soil are 45% plagioclase, 41% pyroxene, 7% olivine, 3% oxides, 2% K-feldspar; 1% nickel-iron, and less than 1% troilite. The glasses have a wide range of compositions but preferred values are evident and are interpreted as representative of rock types contributing to the soil at the Fra Mauro site. Eleven per cent of the glasses have compositions like those of mare basalts or mare soils and are believed to be mare-derived. Eighty-six per cent of the glasses are equivalent in composition to basalts that have higher Al, and lower Ca/Al and Fe/Mg ratios than mare basalts. The most abundant compositional type is named Fra Mauro basaltic glass and is subdivided into three related types. The other major glass type in the soil corresponds in composition to anorthositic gabbro.

Aitken, F. K.↗

Multi-Bandwidth Frequency Selective Surfaces for Near Infrared Filtering: Design and Optimization

Frequency selective surfaces are widely used in the microwave and millimeter wave regions of the spectrum for filtering signals. They are used in telecommunication systems for multi-frequency operation or in instrument detectors for spectroscopy. The frequency selective surface operation depends on a periodic array of elements resonating at prescribed wavelengths producing a filter response. The size of the elements is on the order of half the electrical wavelength, and the array period is typically less than a wavelength for efficient operation. When operating in the optical region, diffraction gratings are used for filtering. In this regime the period of the grating may be several wavelengths producing multiple orders of light in reflection or transmission. In regions between these bands (specifically in the infrared band) frequency selective filters consisting of patterned metal layers fabricated using electron beam lithography are beginning to be developed. The operation is completely analogous to surfaces made in the microwave and millimeter wave region except for the choice of materials used and the fabrication process. In addition, the lithography process allows an arbitrary distribution of patterns corresponding to resonances at various wavelengths to be produced. The design of sub-millimeter filters follows the design methods used in the microwave region. Exacting modal matching, integral equation or finite element methods can be used for design. A major difference though is the introduction of material parameters and thicknesses that may not be important in longer wavelength designs. This paper describes the design of multi- bandwidth filters operating in the 1-5 micrometer wavelength range. This work follows on a previous design. In this paper extensions based on further optimization and an examination of the specific shape of the element in the periodic cell will be reported. Results from the design, manufacture and test of linear wedge filters built using microlithographic techniques and used in spectral imaging applications will be presented.

Cwik, Tom↗

Multi-Bandwidth Frequency Selective Surfaces for Near Infrared Filtering: Design and Optimization

Frequency selective surfaces are widely used in the microwave and millimeter wave regions of the spectrum for filtering signals. They are used in telecommunication systems for multi-frequency operation or in instrument detectors for spectroscopy. The frequency selective surface operation depends on a periodic array of elements resonating at prescribed wavelengths producing a filter response. The size of the elements is on the order of half the electrical wavelength, and the array period is typically less than a wavelength for efficient operation. When operating in the optical region, diffraction gratings are used for filtering. In this regime the period of the grating may be several wavelengths producing multiple orders of light in reflection or transmission. In regions between these bands (specifically in the infrared band) frequency selective filters consisting of patterned metal layers fabricated using electron beam lithography are beginning to be developed. The operation is completely analogous to surfaces made in the microwave and millimeter wave region except for the choice of materials used and the fabrication process. In addition, the lithography process allows an arbitrary distribution of patterns corresponding to resonances at various wavelengths to be produced. The design of sub-millimeter filters follows the design methods used in the microwave region. Exacting modal matching, integral equation or finite element methods can be used for design. A major difference though is the introduction of material parameters and thicknesses tha_ may not be important in longer wavelength designs. This paper describes the design of multi-bandwidth filters operating in the I-5 micrometer wavelength range. This work follows on previous design [1,2]. In this paper extensions based on further optimization and an examination of the specific shape of the element in the periodic cell will be reported. Results from the design, manufacture and test of linear wedge filters built using micro-lithographic techniques and used ir spectral imaging applications will be presented.

Cwik, Tom↗

FUSE/Lyman grant

A variety of options for a short wavelength spectrometer for the Lyman telescope has been studied, and the optimum configuration for this instrument identified. In this spectrometer option study it is assumed (consistent with performance goals outlined by the project) that the instrument, whose prime spectral domain is 900-12000A, will incorporate a grazing incidence telescope which will maintain good collecting efficiency down to 100A. In particular it is assumed that the telescope will have an effective focal length of 10 meters, an image quality of 1.5", and will provide a diverging f/10 beam. Designs compatible with this telescope are analyzed, and it is determined that a two-element grazing incidence spectrometer using as its first optic an ellipsoid to re-focus the beam and a varied line-space plane diffraction grating to disperse the light is the best overall design. This spectrometer could be fed by a small pick-off mirror located just behind the prime focus of the telescope and would clear the light path when not in use. A test of the diffraction efficiency of a low blaze angle grating is undertaken, which is the only technical uncertainty in the spectrometer design.

Hurwitz, M.↗

Optical Design of the Developmental Cryogenic Active Telescope Testbed (DCATT)

In the summer of 1996, three Study teams developed conceptual designs and mission architectures for the Next Generation Space Telescope (NGST). Each group highlighted areas of technology development that need to be further advanced to meet the goals of the NGST mission. The most important areas for future study included: deployable structures, lightweight optics, cryogenic optics and mechanisms, passive cooling, and on-orbit closed loop wavefront sensing and control. NASA and industry are currently planning to develop a series of ground testbeds and validation flights to demonstrate many of these technologies. The Deployed Cryogenic Active Telescope Testbed (DCATT) is a system level testbed to be developed at Goddard Space Flight Center in three phases over an extended period of time. This testbed will combine an actively controlled telescope with the hardware and software elements of a closed loop wavefront sensing and control system to achieve diffraction limited imaging at 2 microns. We will present an overview of the system level requirements, a discussion of the optical design, and results of performance analyses for the Phase 1 ambient concept for DCATT,

Davila, Pam↗

The room-temperature dissociation of the compound Au3Si

Three gold-18.6 at.% silicon specimens which were solidified by quenching from above the liquidus temperature have been reexamined after being stored at room temperature for about 8 years. It was found that the 'metastable' compound Au3Si formed on quenching had begun to dissociate by a surface nucleated, solid-state reaction. The reaction front had advanced about 0.2 mm from the surface, leaving a rim of dissociation products. These dissociation products were studied using optical and scanning electron microscopy, electron beam microprobe analysis and an X-ray micro-diffraction technique. It was concluded that the reaction produces elemental gold and silicon, as at higher reaction temperatures, but that the scale of dispersion is so extremely fine that the resulting microstructure cannot be resolved by scanning electron microscopy.

Bhattacharya, D.↗

Design of optical mirror structures

The structural requirements for large optical telescope mirrors was studied with a particular emphasis placed on the three-meter Large Space Telescope primary mirror. Analysis approaches through finite element methods were evaluated with the testing and verification of a number of element types suitable for particular mirror loadings and configurations. The environmental conditions that a mirror will experience were defined and a candidate list of suitable mirror materials with their properties compiled. The relation of the mirror mechanical behavior to the optical performance is discussed and a number of suitable design criteria are proposed and implemented. A general outline of a systematic method to obtain the best structure for the three-meter diffraction-limited system is outlined. Finite element programs, using the STRUDL 2 analysis system, were written for specific mirror structures encompassing all types of active and passive mirror designs. Parametric studies on support locations, effects of shear deformation, diameter to thickness ratios, lightweight and sandwich mirror configurations, and thin shell active mirror needs were performed.

Soosaar, K.↗

Analysis of near-field Cassegrain reflector - Plane wave versus element-by-element approach

A near-field Cassegrain reflector (NFCR) is an effective way to magnify a small phased array into a much larger-aperture antenna for limited scan applications. Traditionally the pattern analysis of NFCR is based on a plane wave approach, which simplifies the computation tremendously, but fails to provide design information about the most critical component of the whole antenna system, the feed array. Currently available computers make it possible to calculate the pattern of an NFCR by a more exact element-by-element approach. Each element in the feed array is considered individually, and the diffraction pattern from the subreflector is calculated by the geometrical theory of diffraction (including uniform theories at the shadow boundaries). The field contributions from all elements are superimposed at the curved main reflector surface, and a physical-optics integration is performed to obtain the secondary pattern.

Houshmand, Bijan↗

Two-Diffraction-Order, Beam-Splitting, Imaging Spectrometer

Two-octave imaging spectrometer utilizes light of two harmonically related wavelengths diffracted to harmonically related orders at same angles, followed by separation via dichroic beam splitter before final imaging. Conceptual design of spectrometer calls for minimum number of optical elements to achieve coverage of required visible and near-infrared wavelengths in instrument of reduced size, weight, and cost.

Labaw, Clayton C.↗

Mineralogical, Elemental and Tomographic Reconnaissance Investigation for CLPS (“METRIC”)

METRIC comprises a suite of two instruments in a Lunar lander that perform X-ray diffraction (XRD) for mineral structure, X-ray fluorescence (XRF) for elemental composition, and X-ray Micro Computed Tomography (XCT) for 3D internal micromorphology. The instruments are accompanied by optical-near IR cameras to provide local geologic context. The Honeybee Robotics PlanetVac pneumatic sampling and transfer system [1],positioned on a lander footpad, will deliver sieved regolith to the X-ray instruments for analysis. The instrument suite is intended for delivery to the lunar surface on a Commercial Lunar Payload Services (CLPS) lander. The METRICXRD/F instrument draws on heritage from the Mars Science Laboratory CheMin instrument [2] and improves upon the design in multiple ways [3]. Like CheMin, Rietveld refinement and full-pattern fitting of METRIC XRD data can identify minerals at a detection limit of ~1 wt.%, quantify their abundances when present at >3 wt.%, and determine mineral composition (e.g., Fo#in olivine) from lattice parameters for minerals present at >5 wt.%[4,5]. An optimized XRF geometry provides for improved detection and quantification of major, minor and trace elements. The METRIC XCT instrument is a miniaturized X-ray Computed Tomography scanner[6]. Lunar regolith is delivered to a 3 mm diameter, 10 mm long graphite tube inside the instrument. The tube is rotated through 360°in 0.9deg.incrementsand a divergent point source X-ray beam is directed through the material. A Charge Coupled Device (CCD)records attenuation images whose brightness and contrast area function of average atomic number and density. Quantitative data, including particle and void sizes, 3D particle shape parameters, modal volumes and pore geometry can be derived from the resulting 3D reconstructions(voxel resolution: 30 μm). Crystal morphologies derived from METRIC XCT data complement the bulk mineralogy determined by the METRIC XRD/F and provide a measure of grain size distribution for the different phases. Taken together, the METRIC instrument suite determines crystal structure, elemental composition and morphology, three principal characteristics of geological materials that are highly useful in determining the origin and subsequent processing of lunar regolith.

Moon↗

Holographic Optical Elements as Scanning Lidar Telescopes

We have developed and investigated the use of holographic optical elements (HOEs) and holographic transmission gratings for scanning lidar telescopes. For example, rotating a flat HOE in its own plane with the focal spot on the rotation axis makes a very simple and compact conical scanning telescope. We developed and tested transmission and reflection HOEs for use at the first three harmonic wavelengths of Nd:YAG lasers. The diffraction efficiency, diffraction angle, focal length, focal spot size and optical losses were measured for several HOEs and holographic gratings, and found to be suitable for use as lidar receiver telescopes, and in many cases could also serve as the final collimating and beam steering optic for the laser transmitter. Two lidar systems based on this technology have been designed, built, and successfully tested in atmospheric science applications. This technology will enable future spaceborne lidar missions by significantly lowering the size, weight, power requirement and cost of a large aperture, narrow field of view scanning telescope.

Schwemmer, Geary K.↗

Simplified dichromated gelatin hologram recording process

A simplified method for making dichromated gelatin (DCG) holographic optical elements (HOE) has been discovered. The method is much less tedious and it requires a period of processing time comparable with that for processing a silver halide hologram. HOE characteristics including diffraction efficiency (DE), linearity, and spectral sensitivity have been quantitatively investigated. The quality of the holographic grating is very high. Ninety percent or higher diffraction efficiency has been achieved in simple plane gratings made by this process.

Georgekutty, Tharayil G.↗

Observing Exoplanets in the Mid-Ultraviolet

There are good reasons for pushing the spectral range of observation to shorter wavelengths than currently envisaged for terrestrial planet-finding missions utilizing with a 4-m, diffraction-limited, optical telescope: (1) The angular resolution is higher, so the image of an exoplanet is better separated from that of the much brighter star. (2) The exozodiacal background per resolution element is smaller, so exposure times are reduced for the same incident flux. (3) Most importantly, the sensitivity to the ozone biomarker is increased by several hundred-fold by access to the ozone absorption band at 250-300 nm. These benefits must be weighed against challenges arising from the faintness of exoplanets in the mid-UV. We will evaluate both the technical and cost challenges including image quality of large telescopes, advanced mirror coatings and innovative designs for enhanced optical throughput, and CCD detectors optimized for 250-400 nm.

Heap. Sara↗