Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diffusion Coefficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Predicting Treatment Response of Colorectal Cancer Liver Metastases to Conventional Lipiodol-Based Transarterial Chemoembolization Using Diffusion-Weighted MR Imaging: Value of Pretreatment Apparent Diffusion Coefficients (ADC) and ADC Changes Under Therapy

PurposeTo use absolute pretreatment apparent diffusion coefficients (ADC) derived from diffusion-weighted MR imaging (DWI) to predict response to repetitive cTACE for unresectable liver metastases of colorectal carcinoma (CRLM) at 1 and 3 months after start of treatment.Materials and MethodsFifty-five metastases in 34 patients were examined with DWI prior to treatment and 1 month after initial cTACE. Treatment was performed in 4-week intervals. Response was evaluated at 1 and 3 months after start of therapy. Metastases showing a decrease of ≥30% in axial diameter were classified as responding lesions.ResultsOne month after initial cTACE, seven lesions showed early response. There was no significant difference in absolute pretreatment ADC values between responding and non-responding lesions (p = 0.94). Three months after initial cTACE, 17 metastases showed response. There was a significant difference (p = 0.021) between absolute pretreatment ADC values of lesions showing response (median 1.08 × 10{sup −3} mm{sup 2}/s) and no response (median 1.30 × 10{sup −3} mm{sup 2}/s). Pretreatment ADC showed fair diagnostic value to predict response (AUC 0.7). Lesions showing response at 3 months also revealed a significant increase in ADC between measurements before treatment and at one month after initial cTACE (p < 0.001). Applying an increase in ADC of 12.17%, response at 3 months after initial cTACE could be predicted with a sensitivity and specificity of 77 and 74%, respectively (AUC 0.817). Furthermore, there was a strong and significant correlation (r = 0.651, p < 0.001) between percentage change in size after third cTACE and percentage change in ADC.ConclusionIn patients with CRLM, ADC measurements are potential biomarkers for assessing response to cTACE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effective Diffusion Coefficient of Dissolved Metal Ions during 1D Pit Growth

Transport-limited dissolution of metals in corrosion pits is associated with the product of the metal ion diffusion coefficient and total concentration of metal ions (DM+·Ctot). In one dimensional (1D) pit dissolu-tion, the concentration of ionic species varies with location in the pit; at the dissolving pit bottom, the saturation of metal ion and supporting anion is ex-pected under transport control conditions, while the metal ion is nearly depleted at the pit mouth. To describe metal ion transport through pit solution with constantly-changing concentration, an effective diffusion coefficient (Deff) is proposed in this study with consideration of the combined effects of vis-cosity, temperature and electric field inside a grow-ing 1D pit. The modeled Deff·Ctot values were calcu-lated and compared with experimental DM+·Ctot val-ues for S13Cr 1D pit dissolution in different bulk chloride concentrations at 85°C. The modeled Deff·Ctot values were very close to the experimental values, validating the modeling approach suggested in this study.

Jun, Jiheon↗

Cation–polymer interactions and local heterogeneity determine the relative order of alkali cation diffusion coefficients in PEGDA hydrogels

Current research efforts are focused on endowing polymer membranes with ion–ion selectivity by incorporating ion–polymer interactions into materials to bias the selective partitioning and or diffusivity of one species over another. However, little is known about the impact of such interactions on the mechanisms of ion transport. In this study, we probe the influence of cation–polymer interactions on cation, anion, and salt diffusivity in a model membrane material, poly(ethylene glycol) diacrylate (PEGDA) by modeling concentrated polyethylene oxide solutions via molecular dynamics simulations. These results are compared to published experimental data for LiCl, NaCl, and KCl diffusion in PEGDA. Experimentally, the order of salt and cation diffusion coefficients for LiCl, NaCl, and KCl deviate from the order in aqueous solutions. Here, simulations identify these deviations to arise from cation–polymer coordination in the membrane. Both the fraction of bound cations and the average binding lifetime increases with decreasing cation hydration free energy (moving down the alkali series), leading to different diffusivity trends in the membrane compared to solution. However, to recover the experimentally observed order of diffusivities cations and salt in our simulations, we needed to incorporate membrane heterogeneity explicitly via a polymer charge scaling procedure. Together, our results indicate that cation–polymer interactions, as well as spatial heterogeneity within the membrane, play a critical role in dictating the observed order of alkali cation and salt diffusion coefficients in membranes.

36 MATERIALS SCIENCE↗

Construction of generalized quasilinear diffusion coefficient using neural networks with physical restrictions

The quasilinear diffusion coefficient (D QL ) derived from our machine learning framework shows comparable trends with the ground truth D QL obtained from GENRAY-CQL3D simulations. Additionally, for the strong absorption cases, the radial current drive profiles generated using the D QL from our model exhibit consistent behavior with those obtained from the original simulation. These findings indicate the potential of our surrogate modeling approach with physical restrictions to replicate key wave–plasma interaction characteristics while reducing computational costs. Traditionally, calculating D QL for wave–particle interactions relies on computationally intensive wave simulations coupled with Fokker–Planck solvers. To address this challenge, we developed a machine learning-based surrogate model with physical restrictions derived from cold plasma theory and bounce-averaged damping effects. First, we establish the propagation domain of Lower Hybrid Waves in the (N∥, ρ) space by identifying the accessibility limit and determining the upper and lower bounds of N∥ using the Potential Power Deposition (PPD) method. Subsequently, leveraging a database constructed using Latin hypercube sampling alongside the underlying physical restrictions (e.g. PPD), machine learning methods including U-Net and Recurrent Neural Networks are employed to design a physics-restricted machine learning framework capable of reconstructing D QL .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Non-Fermi liquid behavior of the drag and diffusion coefficients in QED plasma

We calculate the drag and diffusion coefficients in low temperature QED plasma and go beyond the leading order approximation. The non-Fermi-liquid behavior of these coefficients are clearly revealed. We observe that the subleading contributions due to the exchange of soft transverse photon in both cases are larger than the leading order terms coming from the longitudinal sector. The results are presented in closed form at zero and low temperature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ON THE DIFFERENT ANALYTICAL RESULTS OBTAINED FOR THE PARALLEL DIFFUSION COEFFICIENT OF COSMIC PARTICLES WITH ADIABATIC FOCUSING

A spatially varying mean magnetic field gives rise to so-called adiabatic focusing of energetic particles propagating through the universe. In the past, different analytical approaches have been proposed to calculate the particle diffusion coefficient along the mean field with focusing. In the present paper, we show how these different results are related to each other. New results for the parallel diffusion coefficient that are more general than previous results are also presented.

79 ASTRONOMY AND ASTROPHYSICS↗

Empirical correlations between the arrhenius' parameters of impurities' diffusion coefficients in CdTe crystals

Understanding of self- and dopant-diffusion in semiconductor devices is essential to our being able to assure the formation of well-defined doped regions. In this paper, we compare obtained in the literature up to date the Arrhenius’ parameters (D=D 0 exp(–ΔE a /kT)) of point-defect diffusion coefficients and the I-VII groups impurities in CdTe crystals and films. We found that in the diffusion process there was a linear dependence between the pre-exponential factor, D 0 , and the activation energy, ΔE a , of different species: This was evident in the self-diffusivity and isovalent impurity Hg diffusivity as well as for the dominant IIIA and IVA groups impurities and Chlorine, except for the fast diffusing elements (e.g., Cu and Ag), chalcogens O, S, and Se, halogens I and Br as well as the transit impurities Mn, Co, Fe. As a result, reasons of the lack of correspondence of the data to compensative dependence are discussed.

97 MATHEMATICS AND COMPUTING↗

Estimation of water diffusion coefficient into polycarbonate at different temperatures using numerical simulation

Nowadays, many electronic systems are exposed to harsh conditions of relative humidity and temperature. Mass transport properties of electronic packaging materials are needed in order to investigate the influence of moisture and temperature on reliability of electronic devices. Polycarbonate (PC) is widely used in the electronics industry. Thus, in this work the water diffusion coefficient into PC is investigated. Furthermore, numerical methods used for estimation of the diffusion coefficient and their assumptions are discussed. 1D and 3D numerical solutions are compared and based on this, it is shown how the estimated value can be different depending on the choice of dimensionality in the model.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Messages Do Diffuse Faster than Messengers: Reconciling Disparate Estimates of the Morphogen Bicoid Diffusion Coefficient

The gradient of Bicoid (Bcd) is key for the establishment of the anterior-posterior axis in Drosophila embryos. The gradient properties are compatible with the SDD model in which Bcd is synthesized at the anterior pole and then diffuses into the embryo and is degraded with a characteristic time. Within this model, the Bcd diffusion coefficient is critical to set the timescale of gradient formation. This coefficient has been measured using two optical techniques, Fluorescence Recovery After Photobleaching (FRAP) and Fluorescence Correlation Spectroscopy (FCS), obtaining estimates in which the FCS value is an order of magnitude larger than the FRAP one. This discrepancy raises the following questions: which estimate is "correct’’; what is the reason for the disparity; and can the SDD model explain Bcd gradient formation within the experimentally observed times? In this paper, we use a simple biophysical model in which Bcd diffuses and interacts with binding sites to show that both the FRAP and the FCS estimates may be correct and compatible with the observed timescale of gradient formation. The discrepancy arises from the fact that FCS and FRAP report on different effective (concentration dependent) diffusion coefficients, one of which describes the spreading rate of the individual Bcd molecules (the messengers) and the other one that of their concentration (the message). The latter is the one that is more relevant for the gradient establishment and is compatible with its formation within the experimentally observed times.

59 BASIC BIOLOGICAL SCIENCES↗

A comment on the position dependent diffusion coefficient representation of structural heterogeneity

Experimental studies of the variation of the mean square displacement (MSD) of a particle in a confined colloid suspension that exhibits density variations on the scale length of the particle diameter are not in agreement with the prediction that the spatial variation in MSD should mimic the spatial variation in density. The predicted behavior is derived from the expectation that the MSD of a particle depends on the system density and the assumption that the force acting on a particle is a point function of position. The experimental data are obtained from studies of the MSDs of particles in narrow ribbon channels and between narrowly spaced parallel plates and from new data, reported herein, of the radial and azimuthal MSDs of a colloid particle in a dense colloid suspension confined to a small circular cavity. In each of these geometries, a dense colloid suspension exhibits pronounced density oscillations with spacing of a particle diameter. We remove the discrepancy between prediction and experiment using the Fisher-Methfessel interpretation of how local equilibrium in an inhomogeneous system is maintained to argue that the force acting on a particle is delocalized over a volume with radius equal to a particle diameter. Our interpretation has relevance to the relationship between the scale of inhomogeneity and the utility of translation of the particle MSD into a position dependent diffusion coefficient and to the use of a spatially dependent diffusion coefficient to describe mass transport in a heterogeneous system.

74 ATOMIC AND MOLECULAR PHYSICS↗

THE IMPLICIT CONTRIBUTION OF SLAB MODES TO THE PERPENDICULAR DIFFUSION COEFFICIENT OF PARTICLES INTERACTING WITH TWO-COMPONENT TURBULENCE

We explore the transport of energetic particles in two-component turbulence in which the stochastic magnetic field is assumed to be a superposition of slab and two-dimensional modes. It is known that in magnetostatic slab turbulence, the motion of particles across the mean magnetic field is subdiffusive. If a two-dimensional component is added, diffusion is recovered. It was also shown before that in two-component turbulence, the slab modes do not explicitly contribute to the perpendicular diffusion coefficient. In the current paper, the implicit contribution of slab modes is explored and it is shown that this contribution leads to a reduction of the perpendicular diffusion coefficient. This effect improves the agreement between simulations and analytical theory. Furthermore, the obtained results are relevant for investigations of diffusive shock acceleration.

79 ASTRONOMY AND ASTROPHYSICS↗

Role of Short-Range Order on Diffusion Coefficients in the Li–Mg Alloy

Li–Mg alloys are important because of their beneficial role in fostering uniform plating and stripping of lithium in all-solid-state batteries. The alloy Li x Mg 1–x forms a solid solution on the BCC crystal structure when the lithium content is greater than x ≈ 0.3. The activation barriers of lithium and magnesium exchanges with a vacancy, crucial for substitutional diffusion, are predicted to be exceptionally low and almost identical, with negligible dependence on the alloy composition. The equilibrium vacancy concentration at room temperature is predicted to be very low, and it also remains almost constant with no dependence on Mg content in the alloy (for x Li ≥ 0.5). Nevertheless, both experiments and kinetic Monte Carlo simulations indicate that the tracer diffusion coefficients decrease by almost an order of magnitude with the addition of Mg to the alloy. In this contribution, the crucial role that chemical short-range order plays in affecting the diffusion coefficients is studied. Chemical short-range order is found to increase the effective activation barrier for lithium and magnesium diffusion by making successive atomic hops with vacancies correlated.

36 MATERIALS SCIENCE↗

EVOLUTION OF THE MAGNETIC FIELD LINE DIFFUSION COEFFICIENT AND NON-GAUSSIAN STATISTICS

The magnetic field line random walk (FLRW) plays an important role in the transport of energy and particles in turbulent plasmas. For magnetic fluctuations that are transverse or almost transverse to a large-scale mean magnetic field, theories describing the FLRW usually predict asymptotic diffusion of magnetic field lines perpendicular to the mean field. Such theories often depend on the assumption that one can relate the Lagrangian and Eulerian statistics of the magnetic field via Corrsin’s hypothesis, and additionally take the distribution of magnetic field line displacements to be Gaussian. Here we take an ordinary differential equation (ODE) model with these underlying assumptions and test how well it describes the evolution of the magnetic field line diffusion coefficient in 2D+slab magnetic turbulence, by comparisons to computer simulations that do not involve such assumptions. In addition, we directly test the accuracy of the Corrsin approximation to the Lagrangian correlation. Over much of the studied parameter space we find that the ODE model is in fairly good agreement with computer simulations, in terms of both the evolution and asymptotic values of the diffusion coefficient. When there is poor agreement, we show that this can be largely attributed to the failure of Corrsin’s hypothesis rather than the assumption of Gaussian statistics of field line displacements. The degree of non-Gaussianity, which we measure in terms of the kurtosis, appears to be an indicator of how well Corrsin’s approximation works.

79 ASTRONOMY AND ASTROPHYSICS↗

Constraining the Diffusion Coefficient with HAWC TeV Gamma-Ray Observations of Two Nearby Pulsar Wind Nebulae

Nearby electron/positron accelerators, mostly Pulsar Wind Nebulae (PWNe), have been pro- posed as potential origins of the positron excess above 10 GeV. The HAWC Observatory reveals two very extended sources spatially coincident with two nearby middle-aged pulsars: Geminga and PSR B0656+14, suggesting ultra-relativistic electrons/positrons accelerated in our backyard. Morphological studies on these two PWNe provide a constraint on the diffusion coefficient at HAWC energies. In this poster, we will present the model development and morphological studies on these PWNe, and the derived diffusion coefficient that best fits the data.

79 ASTRONOMY AND ASTROPHYSICS↗

Hydrogen Diffusion Coefficient Measures on Thin Film Uranium Oxide

Thin films of uranium oxides, putatively UO 2 and U 3 O 8 , were deposited on palladium/silver (75/25) foil discs (10 μm thick, 10 mm diameter). Methodology for sealing these foils, applying a hydrogen pressure (~ 1 atm) to the oxide side, and measuring the pressure on the permeate side (opposite side of foil) is reported. The experimental apparatus is held at 100 °C to speed diffusion, aided by the pressure differential across the foil (~1 atm (750 torr) on oxide side, initially low vacuum on permeate side, ~1x 10 -4 torr). Early results indicate an effective diffusion coefficient of roughly 7.66 x 10 -17 +/- 2.22 x 10 -17 cm 2 /sec for UO 2 . These values are in line with expectations and prior measures relative to large lag times for system baseline (substrate only). Evaluation of the technique for U 3 O 8 thin films suggests further development will be needed to extend the technique to more oxidized films (U 3 O 8 , UO 3 ). Characterization of the foils (thickness and speciation) post diffusion experiments will be carried out by SIGMA (Eric Tegtmeier and Andy Richards) in FY24 which will sharpen the uncertainty quantification for UO 2 diffusion coefficients, aiding the nucleation model for DRACO.

36 MATERIALS SCIENCE↗

Diffusion coefficients from resonant interactions with electrostatic electron cyclotron harmonic waves

Pitch-angle diffusion coefficients have been calculated for resonant interaction with electrostatic electron cyclotron harmonic (ECH) waves using quasilinear diffusion theory. Unlike previous calculations, the parallel group velocity has been included in this study. Further, ECH wave intensity is expressed as a function of wave frequency and wave normal angle with respect to ambient magnetic field. It is found that observed wave electric field amplitudes in Earth's magnetosphere are sufficient to set electrons on strong diffusion in the energy ranges of a few hundred eV. However, the required amplitudes are larger than the observed values for keV electrons and higher by about a factor of 3 compared to past calculations. Required electric field amplitudes are smaller at larger radial distances. It is concluded that ECH waves are responsible for diffuse auroral precipitation of electrons with energies less than about 500 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

WE-G-18C-02: Estimation of Optimal B-Value Set for Obtaining Apparent Diffusion Coefficient Free From Perfusion in Non-Small Cell Lung Cancer

Purpose: Diffusion-weighted MRI (DW-MRI) is increasingly being investigated for radiotherapy planning and response assessment. Selection of a limited number of b-values in DW-MRI is important to keep geometrical variations low and imaging time short. We investigated various b-value sets to determine an optimal set for obtaining monoexponential apparent diffusion coefficient (ADC) close to perfusion-insensitive intravoxel incoherent motion (IVIM) model ADC (ADC IVIM ) in nonsmall cell lung cancer. Methods: Seven patients had 27 DW-MRI scans before and during radiotherapy in a 1.5T scanner. Respiratory triggering was applied to the echo-planar DW-MRI with TR=4500ms approximately, TE=74ms, pixel size=1.98X1.98mm{sub 2}, slice thickness=4–6mm and 7 axial slices. Diffusion gradients were applied to all three axes producing traceweighted images with eight b-values of 0–1000μs/μm{sup 2}. Monoexponential model ADC values using various b-value sets were compared to ADC IVIM using all b-values. To compare the relative noise in ADC maps, intra-scan coefficient of variation (CV) of active tumor volumes was computed. Results: ADC IVIM , perfusion coefficient and perfusion fraction for tumor volumes were in the range of 880-1622 μm{sup 2}/s, 8119-33834 μm{sup 2}/s and 0.104–0.349, respectively. ADC values using sets of 250, 800 and 1000; 250, 650 and 1000; and 250–1000μs/μm{sup 2} only were not significantly different from ADC IVIM (p>0.05, paired t-test). Error in ADC values for 0–1000, 50–1000, 100–1000, 250–1000, 500–1000, and three b-value sets- 250, 500 and 1000; 250, 650 and 1000; and 250, 800 and 1000μs/μm{sup 2} were 15.0, 9.4, 5.6, 1.4, 11.7, 3.7, 2.0 and 0.2% relative to the reference-standard ADC IVIM , respectively. Mean intrascan CV was 20.2, 20.9, 21.9, 24.9, 32.6, 25.8, 25.4 and 24.8%, respectively, whereas that for ADC IVIM was 23.3%. Conclusion: ADC values of two 3 b-value sets (250, 650 and 1000; and 250, 800 and 1000μs/μm{sup 2}) approached ADC IVIM , with relative noise comparable to that of ADC IVIM . These sets may be used to obtain perfusion-insensitive ADC values in lung tumors. E. Weiss: Funding through Varian Medical Systems and Philips Oncology Systems, UpToDate royalties. G. Hugo: NIH R01CA166119, P01 CA116602, NHMRC Project Grant.

60 APPLIED LIFE SCIENCES↗