Search NASA⌕ Search

SEARCH · Search NASA

Results for “Digital Risks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

The Cybersecurity Value-at-Risk Framework

Hydropower remains one of the strongest forms of renewable energy generation methods. It is crucial to address the increasing risks associated with the rapid digitization. The push towards decarbonization also factors in the need to ensure security and resilience for grid-connected renewable energy resources. This report summarizes the U.S. Department of Energy's Water Power Technologies Office's effort to develop a cybersecurity valuation methodology that assists hydropower stakeholders in assessing risks associated with plan operations and gathers valuation guidance through a web-based applicaiton. The Hydropower Cybersecurity Value-at-Risk Framework delivers a platform for industry members to perform self assessments and make informed decisions on their cybersecurity investments.

CVF↗

SU-F-I-53: Coded Aperture Coherent Scatter Spectral Imaging of the Breast: A Monte Carlo Evaluation of Absorbed Dose

Purpose: Coherent scatter based imaging has shown improved contrast and molecular specificity over conventional digital mammography however the biological risks have not been quantified due to a lack of accurate information on absorbed dose. This study intends to characterize the dose distribution and average glandular dose from coded aperture coherent scatter spectral imaging of the breast. The dose deposited in the breast from this new diagnostic imaging modality has not yet been quantitatively evaluated. Here, various digitized anthropomorphic phantoms are tested in a Monte Carlo simulation to evaluate the absorbed dose distribution and average glandular dose using clinically feasible scan protocols. Methods: Geant4 Monte Carlo radiation transport simulation software is used to replicate the coded aperture coherent scatter spectral imaging system. Energy sensitive, photon counting detectors are used to characterize the x-ray beam spectra for various imaging protocols. This input spectra is cross-validated with the results from XSPECT, a commercially available application that yields x-ray tube specific spectra for the operating parameters employed. XSPECT is also used to determine the appropriate number of photons emitted per mAs of tube current at a given kVp tube potential. With the implementation of the XCAT digital anthropomorphic breast phantom library, a variety of breast sizes with differing anatomical structure are evaluated. Simulations were performed with and without compression of the breast for dose comparison. Results: Through the Monte Carlo evaluation of a diverse population of breast types imaged under real-world scan conditions, a clinically relevant average glandular dose for this new imaging modality is extrapolated. Conclusion: With access to the physical coherent scatter imaging system used in the simulation, the results of this Monte Carlo study may be used to directly influence the future development of the modality to keep breast dose to a minimum while still maintaining clinically viable image quality.

60 APPLIED LIFE SCIENCES↗

IBR Digital Supply Chain Gap Analysis and Recommendations

The adoption of clean energy technologies, including solar photovoltaics, continues to introduce non-traditional stakeholders to the operations and planning of the electric system. Stakeholders such as manufacturers, vendors, owners, aggregators, and others are enabling the adoption, integration, and optimum operations of solar technologies at accelerated rates. Inverters form the foundation of many digitally controlled energy sources for clean energy technologies, including Solar, Battery Energy Storage Systems, Hybrid Systems, and Hydrogen Fuel Cells. Their supply chain is complex, a series of microchips, electronic switches and other components making up its primary functions. The complexity of this space and the growing digitization associated with these components can create supply chain cyber risks. One measure to mitigate cybersecurity attacks is proper digital supply chain security. The U.S. Department of Energy (DOE) Solar Energy Technologies Office (SETO), in partnership with the Cybersecurity, Energy, Security, and Emergency Response (CESER) office, is hosting a workshop to bring together solar vendors and services providers to discuss digital supply chain security for solar systems and challenges and opportunities in the transitioning to a fully domestic supply chain for solar energy in the U.S. This workshop will support the Securing Solar for the Grid (S2G) and Energy Cyber Sense program activities. During the workshop, industry experts and researchers from DOE National Laboratories will discuss the current solar supply chain landscape and the transition to domestic manufacturing of solar components in the U.S. Tools and techniques to better manage and secure the digital supply chain of solar devices and systems will be discussed.

cybersecurity↗

Early Fault Detection in Nuclear Systems: A Digital Engineering Approach

Nuclear energy systems present unique challenges in terms of ensuring safety, reliability, and efficiency during their design and operation. Early fault detection is critical for mitigating risks and fostering system resilience. However, current methods often fall short at identifying faults during early stages, potentially leading to costly delays and safety risks. The present work proposes a comprehensive digital engineering approach that leverages digital twins, digital threads, model-based systems engineering, artificial intelligence, and immersive extended reality to support early fault detection in nuclear systems. Through a series of case studies, we highlight specific gaps in the fault detection mechanisms of traditional nuclear design and operation processes, then demonstrate a suite of solutions we are working to implement to address these shortcomings in similar projects. Our findings suggest that a digital engineering approach to design and operation can significantly improve fault detection, ultimately leading to reductions in risk.

42 - ENGINEERING↗

Roadmap for Solar Photovoltaic (PV) Cybersecurity: A vision for improving cyber maturity of distributed and utility-scale solar energy installations

As the solar energy sector continues to expand, its integration into the broader energy infrastructure presents both unprecedented opportunities and new risks. The increasing reliance on digital technologies and interconnected systems in solar energy creates an expanded attack surface for motivated cyber adversaries. Cyberattacks have the potential to cause disruptions in energy production, damage to equipment, financial losses, and compromises in national security. Therefore, ensuring robust cybersecurity measures is paramount to protect the integrity, availability, confidentiality, and access control of solar energy systems. However, there are still key gaps and challenges to be addressed in industry and research, which stakeholders must race to address as they combat a growing number of real-world cyber incidents that affect solar energy systems and a growing number of vulnerabilities discovered and disclosed in key types of equipment. This roadmap explore the current state of solar PV cybersecurity and the gaps and challenges still to be addressed.

14 - SOLAR ENERGY↗

Creating a Simulation Platform for Research and Development of Advanced Control Methods

Advanced nuclear reactors are essential to meet the changing energy requirements throughout both the United States and the rest of world. In addition to other features, they are designed to enable deployment in remote locations and operate in a fully (or near-fully) autonomous manner, which will require a new control paradigm. To realize autonomously operating reactors, the U.S. Department of Energy’s Nuclear Energy Enabling Technologies Advanced Sensors and Instrumentation (NEET ASI) program conducts research and development into the enabling technologies and methods needed, including digital twins, machine learning, and risk modeling, in addition to various types of control methods. These technologies and methods are the key foundations needed to achieve fully autonomous systems. To develop and evaluate the technologies and methods necessary for achieving autonomous operations, it is critical to identify a software tool capable of integrating all the required elements. In surveying the available solutions, no software platforms were identified that could accomplish what was needed without introducing drawbacks. This challenge was the motivation for the current effort: to develop a software platform that can seamlessly integrate autonomouscontrol-enabling technologies and methods, allowing for accelerated research and development and transfer of ideas. The resulting platform, known as the Control and Optimization Modular Modeling Application for Nuclear Deployment (COMMAND), is Python-based, and leverages open-source tools to provide flexibility and facilitate building upon prior research. It is designed to enable advanced reactor developers to deploy and test advanced control technologies and methods coupled with their own models, solutions, and hardware. Given the substantial undertaking of developing such a platform, the current effort focused on laying down scalable, flexible software foundations and infrastructure, then demonstrating the platform via a use case. These foundations included developing generic modules, which contain the base variable and system blocks (the information and functional building blocks, respectively, that can be used to design a simulation) and the data handling and storage blocks needed to exchange information between the various blocks; as well as enablingtechnology-specific modules. This platform was evaluated via a use case, which was to simulate and control a process for the Microreactor Automated Control System (MACS) test bed. While MACS is not currently directly coupled to any specific microreactor physics, it was initially developed in concert with the Microreactor Applications Research Validation and Evaluation (MARVEL) microreactor, and so the MARVEL physics are used here. As part of this use case, several enabling-technology-specific blocks within COMMAND were integrated, including a proportional integral derivative (PID) control block, a Reactor Excursion and Leak Analysis Program (RELAP5-3D) block, and an anomaly detection block. The COMMAND software platform was successfully demonstrated to achieve the scalability and flexibility objectives of this effort and will be leveraged by the program’s research efforts to advance state of the art control methodologies towards autonomous operations of advanced reactors. As new use cases are created and implemented, it is anticipated that COMMAND will continue to grow and evolve to meet new requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Navigating United States Standards and Regulation for Digital Energy Systems

This report provides an analysis of the U.S. standards and regulatory landscape for digital energy systems, focusing on cybersecurity, safety, and reliability requirements. It examines the interplay between federal mandates, state regulations, voluntary industry standards, and utility-specific policies, highlighting critical gaps between compliance and real-world risk mitigation. While NERC CIP standards enforce cybersecurity for Bulk Electric System assets, distribution-level infrastructure and emerging technologies often fall outside mandatory oversight, creating vulnerabilities. The report identifies systemic challenges such as reliance on self-attestation, uneven state adoption of safety codes, and lagging standards for advanced technologies like battery energy storage and inverter-based resources. Through a detailed gap analysis, it underscores the urgency of proactive risk-based approaches, independent verification, and strategic engagement with state and federal entities. Recommendations include adopting tiered security frameworks, strengthening procurement practices, and addressing emerging technology risks to ensure resilient and secure digital energy infrastructure. This guidance is intended for utilities, regulators, and stakeholders navigating compliance obligations and seeking to enhance cybersecurity and safety beyond minimum standards.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Digital Calibration of TR Modules for Real-time Digital Beamforming SweepSAR Architectures

Real-time digital beamforming, combined with lightweight, large aperture reflectors, enable SweepSAR architectures such as that of the proposed DESDynI [Deformation, Ecosystem Structure, and Dynamics of Ice] SAR [Synthetic Aperture Radar] Instrument (or DSI). These new instrument concepts require new methods for calibrating the multiple channels, which must be combined on-board, in real-time. The calibration of current state-of-the-art Electronically Steered Arrays typically involves pre-flight TR (Transmit/Receive) module characterization over temperature, and in-flight correction based on temperature, which ignores the effects of element aging and drifts unrelated to temperature. We are developing new methods for digitally calibrating digital beamforming arrays to reduce development time, risk and cost of precision calibrated TR modules for array architectures by accurately tracking modules' characteristics through closed-loop Digital Calibration, thus tracking systematic changes regardless of temperature. The benefit of this effort is that it would enable a new class of lightweight radar architecture, Digital Beamforming with SweepSAR, providing significantly larger swath coverage than conventional SAR architectures for solid earth and biomass remote sensing, while reducing mission mass and cost. This new instrument concept requires new methods for calibrating the multiple channels, which must be combined on-board, in real-time.

Real-time digital beamforming↗

Digitally Calibrated TR Modules Enabling Real-Time Beamforming SweepSAR Architectures for DESDynI-Class Radar Instruments

Real-time digital beamforming, combined with lightweight, large aperture reflectors, enable SweepSAR architectures such as that of the proposed DESDynI [Deformation, Ecosystem Structure, and Dynamics of Ice] SAR [Synthetic Aperture Radar] Instrument (or DSI). SweepSAR promises significant increases in instrument capability for solid earth and biomass remote sensing, while reducing mission mass and cost. This new instrument concept requires new methods for calibrating the multiple channels, which must be combined on-board, in real-time. We are developing new methods for digitally calibrating digital beamforming arrays to reduce development time, risk and cost of precision calibrated TR modules for array architectures by accurately tracking modules' characteristics through closed-loop Digital Calibration, thus tracking systematic changes regardless of temperature

SweepSar↗

INL Background, Capabilities, and Research Discussion for Potential COG Collaborations

Slides discussing general INL capabilities in a variety of research areas including LWRS, Plant Modernization, Risk-Informed Systems Analysis, the INL Digital Innovation Center of Excellence DICE, integrated online dynamic plant models, online deterministic failure-mode and reliability models of plant systems, equipment and components, and plant information models.

99 GENERAL AND MISCELLANEOUS↗

Analyzing Hardware and Software Common Cause Failures in Digital Instrumentation and Control Systems using Dual Error Propagation Method

This paper develops a methodology for quantifying software common cause failures (CCFs) in digital instrumentation and control (I&C) systems of nuclear power plants. To support the transition of analog I&C systems to digital in nuclear power plants, probabilistic risk assessment (PRA) techniques are used. The hardware components of the I&C systems have reliability databases that can be used in the PRA studies. However, the failure data for redundant software components of the systems is sparse. Failure of components constitutes a CCF, wherein two or more components or systems fail due to a single shared cause and coupling mechanism. This paper proposes a quantification approach that can simultaneously model hardware and software components, incorporate the CCFs of software systems in the models, and bridge the gap between the failure quantification of models and the development of CCF parametric databases. We demonstrate the dual error propagation method (DEPM) by developing I&C systems failure models for a representative digital reactor trip system. The DEPM models are built to simulate the control and data flows within the systems and can accommodate failure states. By expanding DEPM to software CCFs, we generated alpha factor parameter estimates for each of the modeled error propagation mechanisms.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design and construction of a prototype ACTS propagation terminal

The launch schedule for the Advanced Communication Technology Satellite (ACTS) spacecraft did not leave sufficient time for completion of the prototype ACTS Propagation Terminals (APT) prior to initiation of the APT production phase. In fact, the approach used was to construct and test all subassemblies of the terminal with special emphasis on the technically challenging portions. These include the RF front end that uses a state-of-the-art down converter which integrates a low noise amplifier, mixer, post amplifier, filter, and local oscillator port frequency doubler into a single small package. In addition, a new digital receiver that uses the latest DSP technology was developed. Both of these subassemblies were thoroughly tested. The highest risk technology in the APT program was the digital receiver. Several candidate algorithms and DSP chips were investigated early on, primarily under JPL sponsorship. A receiver was constructed based on Texas Instruments chip. The final prototype digital receiver was one based on an Analog Devices chip. The design and test results are documented in a report prepared for this grant. A Primary Design Review (PDR) was conducted 30 May 1991, and a Critical Design Review was held 7 Jul. 1992. Final complete documentation of the APT's will appear in the form of three reports: a hardware description report, a report on the data collection code (ACTS VIEW), and a report on the preprocessing code.

Stutzman, Warren↗

Technical Specification Surveillance Interval Extension Using Self-Diagnostics

As part of the Light Water Reactor Sustainability program, an ongoing research effort is being conducted on technical specifications surveillance interval extension of digital equipment in nuclear power plants. The research team is led by Idaho National Laboratory and includes Pacific Northwest National Laboratory, Technology Resources, and Oak Ridge National Laboratory. This research focuses on developing methods for applying the U.S. Nuclear Regulatory Commission (NRC)–approved guidance to implement a licensee-controlled, risk-informed surveillance frequency change program in digital instrumentation and control (I&C) systems that include self-diagnostics and online monitoring (OLM) capabilities. Although approved methods exist for extending technical specifications (TS) surveillance test intervals (STIs) for general equipment, including analog I&C equipment, gaps remain in technology and guidance on crediting newer digital equipment’s internal self-diagnostics and OLM characteristics. Previous research described a general methodology for crediting internal self-diagnostics for extending surveillance test intervals. The methodology used self-diagnostics to detect—and credited recovery from—failure. Self-diagnostics were also applied for performance monitoring during the extended surveillance interval. This report discusses the status of recent activities to evaluate the previously developed methodology using a pilot study. Although both a utility partner for a pilot study and a specific digital asset were identified in FY2020, delays in obtaining proprietary information resulted in a limited ability to fully evaluate the methodology, and further interactions were complicated by the COVID pandemic. Therefore, at that time, the use of public-domain information—along with current processes for surveillance interval extension through a surveillance frequency control program—identified the need to fully assess diagnostic coverage as part of the pilot study. Furthermore, self-diagnostics were also identified as a potential option to replace the drift analyses conducted as part of current STI extension procedures. In FY2022, the project was reconstituted with the industry partner, and information and data were made available by the industry partner to the research team for review. The shared information included failure event descriptions and data for a digital I&C system since its implementation, as well as recent STI extension interval reports developed by the utility partner on that digital I&C system. This report presents an evaluation of this information and data and describes an application of the proposed methodology cited above. The methodology seeks to take advantage of the self-diagnostics and OLM capabilities to reduce risk or reduce the level of qualitative monitoring assessment needed to perform a risk-informed STI extension using existing NRC approved guidance or both. Addressing these issues of STI extension by crediting self-diagnostics is likely to result in benefits for current and future nuclear power plant (NPP) operations, including lowering the barriers to adoption of digital I&C systems and increasing cost savings by deferring or eliminating unneeded preventive maintenance (tasks or checks or activities). Specifically, self-diagnostic and OLM capabilities of newer digital equipment being installed in non-safety and safety applications are designed to detect failures, provide early warning of potential failures, and notify plant operators to take appropriate action to reduce out of service (OOS) time thus protecting safety margins. Moreover, the equipment is expected to provide information that time-related operational degradation is identified early to ensure timely and planned corrective actions instead of a reactive and unplanned approach ahead of an extended-surveillance interval.

42 ENGINEERING↗

Digital Assurance for Grid Reliability in the Era of Large Load Growth

The rapid expansion of large electric loads is reshaping the operational and regulatory landscape of the U.S. electric grid. These facilities are reaching new scales of expansion, now exceeding a gigawatt per site, and their highly sensitive, digitally driven behaviors introduce new reliability risks. Recent grid events, including large load losses following routine transmission disturbances, highlight the consequences of limited ride-through capability, inconsistent protection settings, inadequate modeling, and lack of behind-the-meter visibility. Parallels to earlier integration challenges of new grid technologies suggest that the grid’s existing processes, standards, and interconnection frameworks are no longer adequate for emerging large loads. This brief synthesizes lessons from the evolution of inverter-based resource regulation and applies them to large-load integration. It identifies critical gaps in modeling accuracy, interconnection processes, performance standards, and compliance mechanisms. Technical recommendations emphasize advanced monitoring, improved modeling, coordinated communication protocols, modernized substations, and structured behind-the-meter control schemes. Collectively, these measures provide a roadmap to maintain bulk power system reliability while enabling the continued growth of large, electrified digital infrastructure.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Development and Application of Virtual Nuclear Power Plant Platform Concerning Environment and Society Digitally

Virtual Nuclear Power Plant, named Virtual4DS, which is developed by the advanced nuclear energy research team (FDS Team), is a platform for full range, whole cycle safety assessment and emergency decision of nuclear power plant in the digital environment and society. The function framework of Virtual4DS is shown in Fig. 1, and it is designed to ensure an overall optimization design of nuclear power plant, achieve comprehensive evaluation of safety and control of risk, and supply the decision support for accident emergency by the accident probability analysis, environmental consequence assessment and public risk evaluation built on the core of digital reactor and the foundation of the nuclear energy big data. Therefore, Virtual4DS is eligible to be applied in reactor safety, radiation safety and environment impact, emergency and public safety. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

HAZARD ANALYSIS OF DIGITAL ENGINEERED SAFETY FEATURES ACTUATION SYSTEM IN ADVANCED NUCLEAR POWER PLANTS USING A REDUNDANCY-GUIDED APPROACH

Replacing the existing aging analog instrumentation and control (I&C) systems with modern safety control and protection digital technology offers one of the foremost means of performance improvements and cost reductions for the existing nuclear power plants (NPPs). However, the qualification of digital I&C systems remains a challenge, especially considering the issue of software common-cause failures (CCFs), which are difficult to address. With the application and upgrades of advanced digital I&C systems, software CCFs have become a potential threat to plant safety because most redundant designs use similar digital platforms or software in the operating and application systems. With complex designs of multilayer redundancy to meet the single-failure criterion, digital I&C safety systems (e.g., engineered safety-features actuation system [ESFAS]) are of a particular concern in the U.S. Nuclear Regulatory Commission (NRC) licensing procedures. This paper applies a modularized approach to conduct redundancy-guided systems-theoretic hazard analysis for an advanced digital ESFAS with multilevel redundancy designs. Systematic methods and risk-informed tools are incorporated to address both hardware and software CCFs, which provide guidance to eliminate the triggers of potential single points of failure in the design of digital safety systems in advanced plant designs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data Centers and Digital Assurance Workshop 2 – Prioritizing Digital Assurance Challenges, Session 2

The second session of the TADA (Technical Assistance for Digital Assurance) Data Centers Cohort, held on November 10, 2025, focused on prioritizing digital assurance challenges at the intersection of data centers and the electric grid. Building on the foundational concepts introduced in Workshop 1, this session deepened the application of the Threat–Vulnerability–Consequence (TVC) framework and emphasized the urgency of addressing cybersecurity, supply chain integrity, and operational reliability. Participants explored the growing convergence of digital and physical systems, the expanding attack surface due to global supply chain dependencies, and the implications of AI-driven load behavior. Real-world incidents—including the Volt Typhoon campaign and vulnerabilities in Solarman and Deye platforms—were analyzed to illustrate the risks of unpatched systems, insecure APIs, and inadequate vendor oversight. Key themes included architecture and interface weaknesses, governance gaps, and human and procedural shortcomings. The workshop also examined the evolving regulatory landscape, highlighting new federal mandates around Foreign Entity of Concern (FEOC) compliance and large-load reliability standards. Through interactive exercises, stakeholders ranked and mapped digital assurance risks from their respective perspectives—utilities, operators, and vendors—laying the groundwork for mitigation strategies and shared accountability models to be developed in Workshop 3. Session 2 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Protecting Privacy of Shared Epidemiologic Data without Compromising Analysis Potential

Objective . Ensuring privacy of research subjects when epidemiologic data are shared with outside collaborators involves masking (modifying) the data, but overmasking can compromise utility (analysis potential). Methods of statistical disclosure control for protecting privacy may be impractical for individual researchers involved in small-scale collaborations. Methods . We investigated a simple approach based on measures of disclosure risk and analytical utility that are straightforward for epidemiologic researchers to derive. The method is illustrated using data from the Japanese Atomic-bomb Survivor population. Results . Masking by modest rounding did not adequately enhance security but rounding to remove several digits of relative accuracy effectively reduced the risk of identification without substantially reducing utility. Grouping or adding random noise led to noticeable bias. Conclusions . When sharing epidemiologic data, it is recommended that masking be performed using rounding. Specific treatment should be determined separately in individual situations after consideration of the disclosure risks and analysis needs.

Cologne, John↗