Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distortion correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Re-Evaluation of Active Interlock Envelopes Considering Insertion Device Correction Coils

The Active Interlock (AI) is a system that ensures that the beam position and angle through the NSLS-II storage ring is located so that the machine apertures that may be struck by synchrotron radiation are not exposed to high power beam which may compromise them. Of particular importance in the NSLS-II is to maintain the beam position and angle within the insertion device (ID) straights where insertions devices make high power x-ray beams for users which may compromise the storage ring vacuum chamber. The beam position and angle in the center of the insertion device is calculated using a pair of beam position monitors (BPMs) on either side of the device. The safe area of positions and angles within the insertion device is called the AI envelope. If there is a magnetic element between the BPMs, it needs to be accounted for in the calculation of the beam position and angle. In addition to the permanent magnet arrays that comprise the insertion device itself, there are correction coils that are used to correct any orbit distortions that are generated by imperfections in the device. It has recently come to our attention that these coils are not considered in the AI calculations, nor are the currents in these coils read by the AI. As it may be possible in theory for these coils to produce angles large enough that the synchrotron radiation beam may damage components, we analyzed the possibility for all ID types and configurations. In this report we show what changes are necessary for the AI envelope, and limits placed upon the correction coils to maintain operation of the storage ring without compromising protection.

36 MATERIALS SCIENCE↗

Application of the modified neutron source multiplication method to the prototype FBR Monju

The Modified Neutron Source Method (MNSM) is applied to the Monju reactor. This static method to estimate sub-criticality has already given good results on commercial Pressurized Water Reactors. The MNSM consists both in the extraction of the fundamental mode seen by a detector to avoid the effect of higher modes near sources, and the correction of flux distortion effects due to control rod movement. Among Monju's particularities that have a big influence on MNSM factors are: the presence of two californium sources and the position of the detector, which is located far from the core outside of the reactor vessel. The importance of spontaneous fission and ({alpha},n) reactions, which have increased during the shutdown period of 15 years, will also be discussed. In order to evaluate the detector count rate, an analytical propagation has been conducted from the reactor vessel. For two subcritical states, an estimation of the reactivity has been made and compared to experimental data obtained in the restart experiments at Monju (2010). Results indicate a good agreement between the MNSM reactivity and the reactivity measured with other methods. The reactivity dependence of the correction to apply to point kinetic equation is discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Alcock Paczy'nski test with Baryon Acoustic Oscillations: systematic effects for future surveys

We investigate the Alcock Paczy'nski (AP) test applied to the Baryon Acoustic Oscillation (BAO) feature in the galaxy correlation function. By using a general formalism that includes relativistic effects, we quantify the importance of the linear redshift space distortions and gravitational lensing corrections to the galaxy number density fluctuation. We show that redshift space distortions significantly affect the shape of the correlation function, both in radial and transverse directions, causing different values of galaxy bias to induce offsets up to 1% in the AP test. On the other hand, we find that the lensing correction around the BAO scale modifies the amplitude but not the shape of the correlation function and therefore does not introduce any systematic effect. Furthermore, we investigate in details how the AP test is sensitive to redshift binning: a window function in transverse direction suppresses correlations and shifts the peak position toward smaller angular scales. We determine the correction that should be applied in order to account for this effect, when performing the test with data from three future planned galaxy redshift surveys: Euclid, the Dark Energy Spectroscopic Instrument (DESI) and the Square Kilometer Array (SKA).

79 ASTRONOMY AND ASTROPHYSICS↗

MRI Guidance for Accelerated Partial Breast Irradiation in Prone Position: Imaging Protocol Design and Evaluation

Purpose: To design and evaluate a magnetic resonance imaging (MRI) protocol to be incorporated in the simulation process for external beam accelerated partial breast irradiation. Methods and Materials: An imaging protocol was developed based on an existing breast MRI technique with the patient in the prone position on a dedicated coil. Pulse sequences were customized to exploit T1 and T2 contrast mechanisms characteristic of lumpectomy cavities. A three-dimensional image warping algorithm was included to correct for geometric distortions related to nonlinearity of spatially encoding gradients. Respiratory motion, image distortions, and susceptibility artifacts of 3.5-mm titanium surgical clips were examined. Magnetic resonance images of volunteers were acquired repeatedly to analyze residual setup deviations resulting from breast tissue deformation. Results: The customized sequences generated high-resolution magnetic resonance images emphasizing lumpectomy cavity morphology. Respiratory motion was negligible with the subject in the prone position. The gradient-induced nonlinearity was reduced to less than 1 mm in a region 15 cm away from the isocenter of the magnet. Signal-void regions of surgical clips were 4 mm and 8 mm for spin echo and gradient echo images, respectively. Typical residual repositioning errors resulting from breast deformation were estimated to be 3 mm or less. Conclusions: MRI guidance for accelerated partial breast irradiation with the patient in the prone position with adequate contrast, spatial fidelity, and resolution is possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Effect of Online Image-Guided Anatomical Interventions for Postprostatectomy Cancer Patients

Purpose: To assess daily variations in delivered doses in postprostatectomy patients, using kilovoltage cone-beam CT (CBCT) datasets acquired before and after interventions to correct for observed distortions in volume/shape of rectum and bladder. Methods and Materials: Seventeen consecutive patients treated with intensity-modulated radiotherapy to the prostate bed were studied. For patients with large anatomical variations, quantified by either a rectal wall displacement of >5 mm or bladder volume change of >50% on the CBCT compared with the planning CT, an intervention was performed to adjust the rectum and/or bladder filling. Cumulative doses over the pre- and post-intervention fractions were calculated by tracking the position of the planning CT voxels on different CBCTs using a deformable surface-mapping algorithm. Dose and displacements vectors were projected on two-dimensional maps, the minimal dose received by the highest 95% of the planing target volume (PTV D95) and the highest 10% of the rectum volume (D10) as well as the bladder volume receiving >2 Gy (V2) were evaluated. Results: Of 544 fractions, 96 required intervention. Median (range) number of interventions per patient was 5 (2-12). Compared with the planning values, the mean (SD) pre- vs. postintervention value for PTV D95 was -2% (2%) vs. -1% (2%) (p < 0.12), for rectum D10 was -1% (4%) vs. +1% (4%) (p < 0.24), and for bladder V2 was +6% vs. +20% (p < 0.84). Conclusions: Interventions to reduce treatment volume deformations due to bladder and rectum fillings are not necessary when patients receive daily accurate CBCT localization, and the frequency of those potential interventions is low. However, for hypofractionated treatments, the relative frequency can significantly increase, and interventions can become more dosimetrically beneficial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improvements in optical metrology for high-performance variable-line-spacing x-ray gratings

Here, we discuss a project to develop a precision metrology system for variable-line-spacing x-ray gratings using interferometric microscopes. We are developing test standards and calibration techniques to measure and correct for geometrical distortion and blur, and data processing techniques to combine multiple measurements and measure line spacing with high accuracy.

Calibration methods↗

Neural posterior unfolding

Differential cross section measurements are the currency of scientific exchange in particle and nuclear physics. A key challenge for these analyses is the correction for detector distortions, known as deconvolution or unfolding. Binned unfolding of cross section measurements traditionally rely on the regularized inversion of the response matrix that represents the detector response, mapping pre-detector (`particle level') observables to post-detector (`detector level') observables. In this paper we introduce Neural Posterior Unfolding, a modern, Bayesian approach that leverages normalizing flows for unfolding. By using normalizing flows for neural posterior estimation, NPU offers several key advantages including implicit regularization through the neural network architecture, fast amortized inference that eliminates the need for repeated retraining, and direct access to the full uncertainty in the unfolded result. In addition to introducing NPU, we implement a classical Bayesian unfolding method called Fully Bayesian Unfolding (FBU) in modern Python so it can also be studied. These tools are validated on simple Gaussian examples and then tested on simulated jet substructure examples from the Large Hadron Collider (LHC). We find that the Bayesian methods are effective and worth additional development to be analysis ready for cross section measurements at the LHC and beyond.

Analysis and statistical methods↗

Energy distribution of ternary {alpha} particles in spontaneous fission of {sup 252}Cf

The energy distribution of the ternary {alpha} particles in spontaneous fission of {sup 252}Cf was measured. For the first time an energy threshold as low as 1 MeV was reached. The experiment used an array of unshielded silicon detectors measuring energy and time-of-flight (TOF) of ternary particles in coincidence with fission fragments. The TOF resolution of the system was sufficient for clear separation of {sup 6}He and tritons from {sup 4}He. The statistics were adequate to extract the {sup 6}He/{sup 4}He yield ratio. For both {sup 4}He and {sup 6}He, an excess in the yield (as compared to a Gaussian shape) was observed at energies below 9 MeV. The measured ternary {alpha} spectrum was corrected for the distortion induced by the detection geometry covering equatorial particle emission only. The emission angle was found to affect mainly the width of the energy distribution by up to 1 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Error analysis of marker-based object localization using a single-plane XRII

The role of imaging and image guidance is increasing in surgery and therapy, including treatment planning and follow-up. Fluoroscopy is used for two-dimensional (2D) guidance or localization; however, many procedures would benefit from three-dimensional (3D) guidance or localization. Three-dimensional computed tomography (CT) using a C-arm mounted x-ray image intensifier (XRII) can provide high-quality 3D images; however, patient dose and the required acquisition time restrict the number of 3D images that can be obtained. C-arm based 3D CT is therefore limited in applications for x-ray based image guidance or dynamic evaluations. 2D-3D model-based registration, using a single-plane 2D digital radiographic system, does allow for rapid 3D localization. It is our goal to investigate - over a clinically practical range - the impact of x-ray exposure on the resulting range of 3D localization precision. In this paper it is assumed that the tracked instrument incorporates a rigidly attached 3D object with a known configuration of markers. A 2D image is obtained by a digital fluoroscopic x-ray system and corrected for XRII distortions ({+-}0.035 mm) and mechanical C-arm shift ({+-}0.080 mm). A least-square projection-Procrustes analysis is then used to calculate the 3D position using the measured 2D marker locations. The effect of x-ray exposure on the precision of 2D marker localization and on 3D object localization was investigated using numerical simulations and x-ray experiments. The results show a nearly linear relationship between 2D marker localization precision and the 3D localization precision. However, a significant amplification of error, nonuniformly distributed among the three major axes, occurs, and that is demonstrated. To obtain a 3D localization error of less than {+-}1.0 mm for an object with 20 mm marker spacing, the 2D localization precision must be better than {+-}0.07 mm. This requirement was met for all investigated nominal x-ray exposures at 28 cm FOV, and for all but the lowest two at 40 cm FOV. However, even for those two nominal exposures, the expected 3D localization error is less than {+-}1.2 mm. The tracking precision was {+-}0.65 mm for the out-of-plane translations, {+-}0.05 mm for in-plane translations, and {+-}0.05 deg. for the rotations. The root mean square (RMS) difference between the true and projection-Procrustes calculated location was 1.07 mm. It is believed these results show the potential of this technique for dynamic evaluations or real-time image guidance using a single x-ray source and XRII detector.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a Single-Pass Amplifier for an Optical Stochastic Cooling Proof-of-Principle Experiment at Fermilab's IOTA Facility

Optical stochastic cooling (OSC) is a method of beam cooling which is expected to provide cooling rates orders of magnitude larger than ordinary stochastic cooling. Light from an undulator (the pickup) is amplified and fed back onto the particle beam via another undulator (the kicker). Fermilab is currently exploring a possible proof-of-principle experiment of the OSC at the integrable-optics test accelerator (IOTA) ring. To implement effective OSC a good correction of phase distortions in the entire band of the optical amplifier is required. In this contribution we present progress in experimental characterization of phase distortions associated to a Titanium Sapphire crystal laser-gain medium (a possible candidate gain medium for the OSC experiment to be performed at IOTA). We also discuss a possible option for a mid-IR amplifier

43 PARTICLE ACCELERATORS↗

Forward-Backward Asymmetry in Top Quark Production in ppbar Collisions at sqrt{s}=1.96 TeV

Reconstructable final state kinematics and charge assignment in the reaction p{bar p} {yields} t{bar t} allows tests of discrete strong interaction symmetries at high energy. We define frame dependent forward-backward asymmetries for the outgoing top quark in both the p{bar p} and t{bar t} rest frames, correct for experimental distortions, and derive values at the parton-level. Using 1.9 fb{sup -1} of p{bar p} collisions at {radical}s = 1.96 TeV recorded with the CDF II detector at the Fermilab Tevatron, we measure forward-backward top quark production asymmetries in the p{bar p} and t{bar t} rest frames of A{sub FB}{sup p{bar p}} = 0.17 {+-} 0.08 and A{sub FB}{sup t{bar t}} = 0.24 {+-} 0.14.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A novel method for correction of temporally- and spatially-variant optical distortion in planar particle image velocimetry

In-cylinder flow measurements are necessary to gain a fundamental understanding of swirl-supported, light-duty Diesel engine processes for high thermal efficiency and low emissions. Planar particle image velocimetry (PIV) can be used for non-intrusive, in situ measurement of swirl-plane velocity fields through a transparent piston. In order to keep the flow unchanged from all-metal engine operation, the geometry of the transparent piston must adapt the production-intent metal piston geometry. As a result, a temporally- and spatially-variant optical distortion is introduced to the particle images. Here, to ensure reliable measurement of particle displacements, this work documents a systematic exploration of optical distortion quantification and a hybrid back-projection procedure that combines ray-tracing-based geometric and in situ manual back-projection approaches.

33 ADVANCED PROPULSION SYSTEMS↗

Self-calibration strategies for reducing systematic slope measurement errors of autocollimators in deflectometric profilometry

Deflectometric profilometers are used to precisely measure the form of beam shaping optics of synchrotrons and X-ray free-electron lasers. They often utilize autocollimators which measure slope by evaluating the displacement of a reticle image on a detector. Based on our privileged access to the raw image data of an autocollimator, novel strategies to reduce the systematic measurement errors by using a set of overlapping images of the reticle obtained at different positions on the detector are discussed. It is demonstrated that imaging properties such as, for example, geometrical distortions and vignetting, can be extracted from this redundant set of images without recourse to external calibration facilities. This approach is based on the fact that the properties of the reticle itself do not change – all changes in the reticle image are due to the imaging process. Firstly, by combining interpolation and correlation, it is possible to determine the shift of a reticle image relative to a reference image with minimal error propagation. Secondly, the intensity of the reticle image is analysed as a function of its position on the CCD and a vignetting correction is calculated. Thirdly, the size of the reticle image is analysed as a function of its position and an imaging distortion correction is derived. It is demonstrated that, for different measurement ranges and aperture diameters of the autocollimator, reductions in the systematic errors of up to a factor of four to five can be achieved without recourse to external measurements.

47 OTHER INSTRUMENTATION↗

Correct symmetry in density functional theory calculations of δ-Pu [Slides]

Density functional theory (DFT) calculations in the delta-phase of Pu have long relied on the antiferromagnetic (AFM) spin structure to approximate the material’s unique electronic structure. The resulting tetragonal distortion away from the correct cubic symmetry was believed to be a necessary consequence of allowing an ordered spin structure.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Exact analytical solution of the linear structure growth rate in {Lambda}CDM cosmology and its cosmological applications

We derive the exact analytical solution of the linear structure growth rate in {Lambda}CDM cosmology with flat or curved geometry, under the Newtonian gauge. Unlike the well known solution under the Newtonian limit [D. J. Heath, Mon. Not. R. Astron. Soc. 179, 351 (1977)], our solution takes all general relativistic corrections into account and is hence valid at both the sub- and superhorizon scales. With this exact solution, we evaluate cosmological impacts induced by these relativistic corrections. (1) General relativistic corrections alter the density growth from z=100 to z=0 by 10% at k=0.01 h/Mpc and the impact becomes stronger toward larger scales. We caution the readers that the overdensity is not gauge invariant and the above statement is restrained to the Newtonian gauge. (2) Relativistic corrections introduce a k{sup -2} scale dependence in the density fluctuation. It mimics a primordial non-Gaussianity of the local type with f{sub NL}{sup local{approx}}1. This systematical error may become non-negligible for future all sky deep galaxy surveys. (3) Cosmological simulations with box size greater than 1 Gpc are also affected by these relativistic corrections. We provide a postprocessing recipe to correct for these effects. (4) These relativistic corrections affect the redshift distortion. However, at redshifts and scales relevant to redshift distortion measurements, such effect is negligible.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Method to Determine the Electric Field of Liquid Argon Time Projection Chambers using a UV Laser System and its Application in MicroBooNE

Liquid argon time projection chambers (LArTPCs) are today a standard detector technology for accelerator neutrino measurements, due to their high density, precise tracking, and calorimetric capabilities. An electric field (E-field) is required in such detectors to drift ionization electrons to the anode to be collected. The E-field of a TPC is often assumed to be uniform between the anode and the cathode. However, significant distortions can appear from effects such as mechanical distortions, failures, or the accumulation of space charge generated by cosmic rays. The latter is particularly relevant for detectors placed near the Earth’s surface and with large drift distances. To determine the E-field in situ, an ultraviolet (UV) laser system is installed in the MicroBooNE experiment at Fermi National Accelerator Laboratory. The purpose of this system is to provide precise measurements of the E-field, and to make it possible to correct for 3D spatial distortions due to E-field non-uniformities. Here we describe the methodology developed for deriving spatial distortions, the drift velocity and the E-field from UV-laser measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A method to determine the electric field of liquid argon time projection chambers using a UV laser system and its application in MicroBooNE

Liquid argon time projection chambers (LArTPCs) are now a standard detector technology for making accelerator neutrino measurements, due to their high material density, precise tracking, and calorimetric capabilities. An electric field (E-field) is required in such detectors to 2020 JINST 15 P07010 drift ionization electrons to the anode where they are collected. The E-field of a TPC is often approximated to be uniform between the anode and the cathode planes. However, significant distortions can appear from effects such as mechanical deformations, electrode failures, or the accumulation of space charge generated by cosmic rays. The latter effect is particularly relevant for detectors placed near the Earth’s surface and with large drift distances and long drift time. To determine the E-field in situ, an ultraviolet (UV) laser system is installed in the MicroBooNE experiment at Fermi National Accelerator Laboratory. The purpose of this system is to provide precise measurements of the E-field, and to make it possible to correct for 3D spatial distortions due to E-field non-uniformities. Here we describe the methodology developed for deriving spatial distortions, the drift velocity and the E-field from UV-laser measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗