High-Resolution Synthetic Solar Irradiance Sequence Generation: An LSTM-Based Generative Adversarial Network

The rapid growth of renewable energy resources penetration is bringing more challenges to power system planning and operation. Relevant renewable energy integration studies, such as the capability and dynamic performance of inverter-based resources' primary frequency response and fast frequency response, require high-resolution renewable generation output data that are representative of renewable energy resources. This paper focuses on creating synthetic but realistic solar irradiance data and proposes a long short-term memory-based generative adversarial network to generate high-resolution (second-level) solar irradiance sequences from low-resolution (minute-level) measurements. Combined with a classifier to recognize the solar irradiance patterns, the proposed model is trained using multi-loss functions to accurately capture the temporal correlations among both high-resolution and low-resolution sequences. Verification of the proposed approach is performed on the data set of the Oahu Solar Measurement Grid collected through the National Renewable Energy Laboratory. The results of the case studies demonstrate the proposed approach's capability to capture the statistical characteristics of different solar irradiance patterns and to generate high-quality synthetic solar irradiance sequences in high resolution.

dynamic scheduling↗

Recent progress on the APOLLO3 calculation scheme for the FLUOLE2 experiment

Studies of the neutron fluence on reactor pressure vessel and the correlated reactor lifetime issues require very good knowledge of the neutron source distribution in the reactor core and especially in the peripheral region. The FLUOLE2 experiment offers an appropriate starting configuration to investigate the possibility of using the APOLLO3 deterministic code with a two-step calculation scheme. It enables us to calculate a pin-by-pin neutron source distribution in the core, then to carry out the neutron propagation from the core to neutron detectors. In this paper, we focus on a calculation scheme dedicated to the determination of core neutron source distribution using APOLLO3 with the SHEM281 energy mesh, a Method of Characteristics (MOC) to solve the transport equation for the lattice computation step and a 20-groups 3D computation using the MINARET SN solver of APOLLO3. Reactivity and pin-by-pin reaction rate results have been analyzed. Results obtained with both lattice and core computations show a good agreement with those produced through a reference calculation using the TRIPOLI-4 Monte Carlo transport code. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Ultra-Fast Resonant DC Breaker

This project’s focus was to create an ultra-fast resonant hybrid dc circuit breaker for medium voltage electric systems. Medium voltage DC systems offer higher efficiency, additional resiliency, more controllability, and greater flexibility over comparable AC systems. Although technically, medium voltage DC systems are more attractive than their AC counterparts, no solution exists for the protection of medium voltage DC systems, and thus one cannot build a reliable MVDC system. This research will fill the technology gap, providing a MVDC protection solution, allowing mass adoption and proliferation of MVDC systems. MVDC systems will allow greater integration of renewable energy sources, higher efficiency of transmission and distribution, reduced losses in transmission lines, reduce carbon emissions, and higher electric power reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fluid-kinetic modeling of a high power density radio frequency inductively coupled positive hydrogen ion source

High power density radio-frequency (RF) inductively coupled positive ion sources are attractive candidates for next-generation neutral beam injection (NBI) systems, where higher injected power and longer pulse lengths are desired without sacrificing source reliability. Operating at absorbed power densities of order $\gt 1~\mathrm{W\,cm}^{-3}$ places these sources in a regime with stronger gas heating, higher dissociation, and non-Maxwellian electron energy distributions. The Large Uniform Plasma for Ionizing Neutrals (LUPIN) is an RF inductively coupled plasma source designed to explore this high power density regime and to provide guidance for a positive ion source upgrade for the DIII-D NBI system. LUPIN is designed to operate at up to 20 kW of RF power at 2 MHz, coupling energy through a cylindrical quartz vessel to achieve target ion current densities of $2100\,\mathrm{A\,m}^{-2}$ . This paper presents fluid-kinetic modeling of LUPIN using the hybrid plasma equipment model where electrons are treated kinetically, and the simulations reveal that electron energy distribution function transitions from nearly Maxwellian in the core to bi-Maxwellian towards the edge. Parametric simulations investigate the effects of RF power, gas pressure, and frequency on plasma density, ion flux, and uniformity. Parametric sweeps reveal that increasing power shifts the primary ionization channel from molecular to atomic with diminishing flux gains due to skin-depth contraction and gas rarefaction. Higher frequency localizes heating and increases $\mathrm{H}_2^+$ and $\mathrm{H}_3^+$ delivery to the grid, while elevated pressure boosts ionization yet hinders ion transport due to increase in collisionality.

inductively coupled plasma↗

Dark Energy Survey Year 6 Results: Redshift Calibration of the Weak Lensing Source Galaxies

Determining the distribution of redshifts for galaxies in wide-field photometric surveys is essential for robust cosmological studies of weak gravitational lensing. We present the methodology, calibrated redshift distributions, and uncertainties of the final Dark Energy Survey Year 6 (Y6) weak lensing galaxy data, divided into four redshift bins centered at $\langle z \rangle = [0.414, 0.538, 0.846, 1.157]$. We combine independent information from two methods on the full shape of redshift distributions: optical and near-infrared photometry within an improved Self-Organizing Map $p(z)$ (SOMPZ) framework, and cross-correlations with spectroscopic galaxy clustering measurements (WZ), which we demonstrate to be consistent both in terms of the redshift calibration itself and in terms of resulting cosmological constraints within 0.1$σ$. We describe the process used to produce an ensemble of redshift distributions that account for several known sources of uncertainty. Among these, imperfection in the calibration sample due to the lack of faint, representative spectra is the dominant factor. The final uncertainty on mean redshift in each bin is $σ_{\langle z\rangle} = [0.012, 0.008,0.009, 0.024]$. We ensure the robustness of the redshift distributions by leveraging new image simulations and a cross-check with galaxy shape information via the shear ratio (SR) method.

Yin, B. [Duke U.] (ORCID:0009000656049980)↗

Constraining models for the origin of ultra-high-energy cosmic rays with a novel combined analysis of arrival directions, spectrum, and composition data measured at the Pierre Auger Observatory

The combined fit of the measured energy spectrum and shower maximum depth distributions of ultra-high-energy cosmic rays is known to constrain the parameters of astrophysical models with homogeneous source distributions. Studies of the distribution of the cosmic-ray arrival directions show a better agreement with models in which a fraction of the flux is non-isotropic and associated with the nearby radio galaxy Centaurus A or with catalogs such as that of starburst galaxies. Here, we present a novel combination of both analyses by a simultaneous fit of arrival directions, energy spectrum, and composition data measured at the Pierre Auger Observatory. The model takes into account a rigidity-dependent magnetic field blurring and an energy-dependent evolution of the catalog contribution shaped by interactions during propagation. We find that a model containing a flux contribution from the starburst galaxy catalog of around 20% at 40 EeV with a magnetic field blurring of around 20° for a rigidity of 10 EV provides a fair simultaneous description of all three observables. The starburst galaxy model is favored with a significance of 4.5σ (considering experimental systematic effects) compared to a reference model with only homogeneously distributed background sources. By investigating a scenario with Centaurus A as a single source in combination with the homogeneous background, we confirm that this region of the sky provides the dominant contribution to the observed anisotropy signal. Models containing a catalog of jetted active galactic nuclei whose flux scales with the γ-ray emission are, however, disfavored as they cannot adequately describe the measured arrival directions.

79 ASTRONOMY AND ASTROPHYSICS↗

GA-Based Voltage Optimization of Distribution Feeder with High-Penetration of DERs Using Megawatt-Scale Units

In this paper, genetic algorithm (GA)-based voltage optimization of a modified IEEE-34 node distribution feeder with high penetration of distributed energy resources (DERs) is proposed using two megawatt-scale reactive power sources. Traditional voltage support units present in distribution grids are not suitable for DER-rich feeders, while voltage support using small-scale DERs present in the feeder requires considerable communication effort to reach a global solution. In this work, two megawatt-scale units are placed to improve the voltage profile across the IEEE 34-node feeder, which has been modified to include several PV units and an energy storage unit. The megawatt-scale units are optimized using GA for fast and accurate operation. The performance of the proposed scheme is verified using simulation results with a multi-platform setup where the modified IEEE-34 node feeder is modeled in OpenDSS while the GA optimization scheme is programmed in MATLAB.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Time Sequence Machine Learning-Based Data Intrusion Detection for Smart Voltage Source Converter-Enabled Power Grid

Smart inverters of distributed energy resources can enable cloud computing, condition monitoring, result visualization, remote control, and peer-to-peer energy trading in advanced power systems. However, the advent of data injection attacks in the communication architecture can alter measurement characteristics of power grids and have devastating consequences. In this article, we propose a time sequence machine learning-based anomaly detection methodology for detecting cyber intrusion into control signal setpoints and dc voltage signal measurement bias of the voltage source converter (VSC) in wind generators. We first investigated the effects of four types of denial of service, tampering signal, and stealthy-type data intrusion attacks on smart VSCs and overall wind farms. We then proposed a novel time sequence machine learning-based intrusion detection framework that can be implemented to detect different cyberattacks in the VSCs. The performance of the proposed framework has been compared with that of autoencoder and clustering-based intrusion detection framework. The proposed framework was validated by using the IEEE 39 bus power system in the presence of four wind farms in different locations. Using several metrics for intrusion detection performance, we validated the effectiveness of the proposed framework.

42 ENGINEERING↗

Protecting Customer Privacy Through Distributed Energy Resource Anonymization

Due to their stochastic nature, the increase of Renewable Energy Resources (RERs) as a primary source of energy for power grids creates challenges regarding the reliability and resilience of the system. In order to combat these obstacles, expansion of Distributed Energy Resources (DERs) and their participation in Demand Response (DR) programs is necessary. Widespread participation requires prioritizing customer privacy and addressing concerns that may arise regarding communication between DERs and the Grid Service Provider (GSP). This paper discusses the use of flow reservation resources to split the operating cycles of DER load profiles into unique phases. The splitting of phases increases anonymization of the DERs by making it more difficult to determine the individual characteristics of the device. We discuss an example of this using simulated DER load profile data and examine the resulting effectiveness by using a machine learning algorithm for classification, called Support Vector Machine (SVM).

Distributed Energy Resource, Anonymization, Renewa↗

Impact of High Penetration Distributed Energy Resources on the Bulk Electric System

The growth of distributed energy resources (DERs), mostly generation using intermittent renewable energy sources, along with the retirement of central generation (mostly conventional power plants using fossil-fuel-based resources) has implications for the steady-state and dynamic performance of the bulk electric system (BES). Among the DERs connected to the distribution system, photovoltaic (PV) systems are the most prevalent and have been installed at an increasing rate. Until recently, the penetration levels of DERs have not been high enough to create significant impacts on the reliability and security of power system operation. However, in recent years, the penetration levels of DERs have risen to a level that their impacts on the bulk electric system should be considered in a detailed fashion in planning and operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comprehensive assessment of deep reinforcement learning approaches for economic dispatch in nuclear-driven microgrids

As the electrical grid integrates more variable renewable energy sources such as wind and solar, the demand for distributed and flexible systems to address this increased variability becomes critical. Nuclear-driven microgrids provide a promising solution by offering stable generation to complement intermittent renewables, ensuring grid reliability and operating efficiency. This paper proposes a recurrent deep reinforcement learning framework for optimal economic dispatch in a nuclear-powered microgrid integrating renewable energy sources, small modular reactors, battery storage systems, and balance-of-plant dynamics. A three-agent control architecture is developed, where demand and renewable energy agents act as forecasters, and a reinforcement learning-based dispatch agent performs real-time energy allocation. A nonlinear programming formulation is first used to generate an optimal baseline for benchmarking. The proposed dispatch controller, based on Proximal Policy Optimization enhanced with Long Short-Term Memory networks, exploits temporal correlations in system dynamics by taking advantage of the time series used as inputs to improve policy robustness under uncertainty. Comparative analysis against established deep reinforcement learning methods, including Proximal Policy Optimization with a feedforward architecture, Soft Actor-Critic, and Twin Delayed Deep Deterministic Policy Gradient, demonstrates superior performance. Numerical results indicate that the proposed controller achieves a 0.39% cost reduction relative to the nonlinear programming benchmark and outperforms other learning-based methods by generating additional revenue of up to 0.35%. All reinforcement learning controllers compute dispatch actions in less than 0.3 s, resulting in a computational speedup of more than three orders of magnitude over the nonlinear programming baseline. The findings of this paper highlight their applicability for real-time operation and control in nuclear-integrated microgrids under volatile operating conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Restoration Strategy for Distribution System Resilience Enhancement

In electric power distribution systems, distributed energy resources (DERs) can act as controllable power sources and support utility operators to minimize power outages after extreme weather events (e.g., hurricane, earthquake, wildfire) and thus help enhance the grid's resilience. Meanwhile, the influences of extreme events and the capabilities of DERs are dynamic and difficult to predict. Hence, the desired distribution system restoration strategy should be able to evolve according to real-time fault/dis-turbance information and the availability of DERs. In this paper, we propose a new dynamic restoration strategy for distribution systems to enhance system resilience against potential hazards. An efficient reconfiguration algorithm is developed to eliminate the use of integer variables to relieve the computational burden. Model predictive control is implemented to adjust the system topology and DER operation set points based on the updated fault information and DER forecasts. The effectiveness of the proposed restoration model in enhancing distribution system resilience is validated through an IEEE 123-bus test system. Simulation results also validate that the proposed restoration model can mitigate the occurrence of unexpected events and the fluctuations of DERs.

distributed energy resources (DERs)↗

Dynamic Restoration Strategy for Distribution System Resilience Enhancement

In electric power distribution systems, distributed energy resources (DERs) can act as controllable power sources and support utility operators to minimize power outages after extreme weather events (e.g., hurricane, earthquake, wildfire) and thus help enhance the grid's resilience. Meanwhile, the influences of extreme events and the capabilities of DERs are dynamic and difficult to predict. Hence, the desired distribution system restoration strategy should be able to evolve according to real-time fault/disturbance information and the availability of DERs. In this paper, we propose a new dynamic restoration strategy for distribution systems to enhance system resilience against potential hazards. An efficient reconfiguration algorithm is developed to eliminate the use of integer variables to relieve the computational burden. Model predictive control is implemented to adjust the system topology and DER operation set points based on the updated fault information and DER forecasts. The effectiveness of the proposed restoration model in enhancing distribution system resilience is validated through an IEEE 123-bus test system. Simulation results also validate that the proposed restoration model can mitigate the occurrence of unexpected events and the fluctuations of DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrical Fault and Power Quality Detection Algorithms and Customer-Owned DERs Monitoring with a Cyber Grid Guard System and DLT

In this study, the electrical fault and power quality detection algorithms and customer-owned DERs monitoring use cases were implemented, with a Cyber Grid Guard system and DLT. Electrical utilities continue to deploy more intelligent electronic devices (IEDs) inside and outside electrical substations, and are associated with customer-owned distributed energy resources (DERs). Data from these IEDs, such as power meters and protection relays, must be kept confidential and of high integrity. Blockchain technology has the potential to increase microgrid resilience by enhancing data sharing security. The growing use of IEDs and customer-owned renewable energy sources (DERs) may make it necessary to connect Distributed Ledger Technology (DLT) with power system applications. We implemented the electrical faulted phase detection and power quality monitoring algorithms with a Cyber Grid Guard (CGG) system using DLT. In addition, the DERs (wind turbine farms) use case and protective relay cyber-event tests were assessed, by using the CGG system with DLT. In the experimental model, the testbed was created by using a real-time simulator and CGG system with power meters/ protective relays in the loop. The data collected from the CGG system and IEDs were compared with the same time stamp source. These results showed the successful assessment of protection, control and monitoring applications using a CGG system with DLT. In the future, power system applications for the ESGT with DERs and the CGG system will be based on executing smart contracts between electrical utilities and customer-owned DERs.

Piesciorovsky, Emilio↗

Soft-Switching Solid-State Transformer With Reduced Conduction Loss

Solid-state transformers (SSTs) are a promising solution photovoltaic (PV), wind, traction, data center, battery energy storage system (BESS), and fast charging electric vehicle (EV) applications. The traditional SSTs are typically three-stage, i.e., hard-switching cascaded multilevel rectifiers and inverters with dual active bridge (DAB) converters, which leads to bulky passives, low efficiency, and high electromagnetic interference (EMI). This article proposes a new soft-switching solid-state transformer (S4T). The S4T has full-range zero-voltage switching (ZVS), electrolytic capacitor-less dc link, and controlled dv/dt, which reduces EMI. The S4T comprises two reverse-blocking current-source inverter (CSI) bridges, auxiliary branches for ZVS, and transformer magnetizing inductor as a reduced dc link with 60% ripple. Compared with the prior S4T, an effective change on the leakage inductance diode is made to reduce the number of the devices on the main power path by 20% for significant conduction loss saving and retain the same functionality of damping the resonance between the leakage and resonant capacitors and recycling trapped leakage energy. The conduction loss saving is crucial, being the dominating loss mechanism in SSTs. Importantly, the proposed single-stage SST not only holds the potential for high power density and high efficiency but also has full functionality, e.g., multiport dc loads integration, voltage regulation, and reactive power compensation, unlike the traditional single-stage matrix SST. The S4T can achieve single-stage isolated bidirectional dc–dc, ac–dc, dc–ac, or ac–ac conversion. It can also be configured input-series output-parallel (ISOP) in a modular way for medium-voltage (MV) grids. Hence, the S4T is a promising candidate for the SST. The full functionality, e.g., voltage buck–boost, multiport, etc., and the universality of the S4T for the dc–dc, dc–ac, and ac–ac conversion are verified through the simulations and experiments of two-port and three-port MV prototypes based on 3.3 kV SiC MOSFETs in dc–dc, dc–ac, and ac–ac modes at 2 kV.

14 SOLAR ENERGY↗

Urban cells: Extending the energy hub concept to facilitate sector and spatial coupling

The rapid growth of urban areas and concerns over climate change make it vital to improve the energy sustainability of cities. Understanding the complex interactions within different sectors (sectoral) and localities (spatial) of cities plays a crucial role in improving efficiency and sustainability, which is extremely challenging due to the complex urban morphology. State-of-the-art energy concepts do not facilitate a detailed consideration of both sectoral and spatial coupling that energy infrastructure maintains at the urban scale. This has become a significant challenge when designing interconnected urban energy infrastructure. The Urban Cell concept is introduced to address this bottleneck. A novel computational model using a modular approach is introduced to create an interconnected urban infrastructure, including the energy, building, and transportation sectors. Optimal sizing of the distributed energy system (including renewables, energy storage, and dispatchable sources) and optimal urban morphology is determined within a modular unit. A game-theoretic approach is used to model the interactions between urban cells (modular units). The study revealed that the urban cell concept can reduce the net present value of the interconnected energy infrastructure by 37% while increasing the installed renewable energy capacity by 25%. This demonstrates the benefit potential of urban cells and the importance of considering interactions between different sectors and different parts within a city. The Urban Cell concept can be used to present the complex interactions maintained within a city.

Perera, ATD↗

Powered by dGen Webinar [Slides]

NLR's Powered By Webinar Series featuring NLR's dGen Modeling Tool. The Distributed Generation Market Demand (dGenTM) model simulates customer adoption of distributed energy resources for residential, commercial, and industrial entities in the United States or other countries through 2050. The model enables analysis at multiple geographic levels (national, state, and utility, or below) and offers sophistication in representation of decision-making regarding economic and behavioral considerations. Analysts have used dGen to answer questions about load forecasting and integrated resource planning, policy analysis, locational value of distributed energy resources, and more. dGen is open source, and various energy organizations - including independent system operators, regional transmission organizations, and the California Energy Commission - use the model internally.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Thermal and electric multidomain dynamic model for integration of power grid distribution with behind-the-meter devices

As renewable energy sources like solar and wind power become more integrated into the grid, coordinated control of behind-the-meter devices is crucial for enhancing grid flexibility and reliability and for meeting cost targets, with standardized models being developed to support this transition. The increasing flexibility and uncertainty of integrated renewable energy grids, along with interactions between various subsystems, make traditional steady-state modeling insufficient to capture transient and dynamic behaviors. Current models (e.g., composite load and battery equivalent models) focus on thermodynamic or electrical characteristics but overlook critical electromechanical interactions. This limits the ability to share performance information for grid services and hampers fast dynamic simulations. In addition, motor stalling is usually triggered by a fault event and attributed to the characteristics of the mechanical torque of the motor, resulting in absorption of a large amount of reactive power during the stalling period. Further, this significant withdrawal of reactive power will deteriorate the dynamic voltage stability of power grids and cause delayed voltage recovery. Therefore, an in-depth modeling of the thermodynamics or mechanical torque is essential to study the impacts of the realistic torque characteristics of those behind-the-meter devices on power system voltage stability. This study developed a dynamic multidomain model for building HVAC systems, such as air-source heat pumps, to simulate their thermal and electrical responses to grid transients. The model can accurately predict power metrics with a mean absolute percentage error of 10%, by validating against with power system computer-aided design performance data. Case studies demonstrate the model capability of capturing the transient response to sudden voltage changes, rapid load fluctuations, and system shutdowns respectively. During a sudden voltage drop (30% for 0.1s), a fully loaded heat pump’s motor speed dropped, continued declining, and shut down after 3.6s, with severe power oscillations and a torque spike. A partially loaded unit experienced temporary oscillations but stabilized. Under higher building loads, compressor speed increased from 64% to 100%, with power and torque rising before stabilizing. In safety-triggered shutdowns, power decreased after minor fluctuations, and torque briefly spiked before dropping to zero.

24 POWER TRANSMISSION AND DISTRIBUTION↗