Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distribution Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Outage Forecast-Based Preventative Scheduling Model for Distribution System Resilience Enhancement: Preprint

Distribution system resilience enhancement is an important topic to ensure customers have access to the power supply during extreme events. In fact, certain weather-related extreme events can be predicted ahead of time. Therefore, it is important to investigate how to predict grid outages using extreme weather forecasts, and how outage predictions can be incorporated into distribution system resilience enhancement. In this paper, a preventative scheduling model for distribution systems is proposed. The model targets at allocating resources, especially mobile responsive resources such as mobile backup generators and mobile energy storage systems, to prepare for an extreme event in the day-ahead context. To achieve efficient resource allocation and scheduling, a machine learning-based outage prediction module is developed to predict vulnerable or risky segments of the distribution system based on historical operating records and extreme weather event forecasts. By integrating the outage prediction results into the scheduling model, optimal resource allocation can be derived to help distribution systems prepare for an upcoming event and improve resilience performance. A real distribution feeder in North Carolina, U.S. is used in the case study to validate the proposed approach.

distributed energy resources↗

Distribution System Pricing with Distributed Energy Resources

Technological changes in the electric utility industry bring tremendous opportunities and significant challenges. Customers are installing clean sources of on-site generation such as rooftop solar photovoltaic (PV) systems. At the same time, smart appliances and control systems that can communicate with the grid are entering the retail market. Among the opportunities these changes create are a cleaner and more diverse power system, the ability to improve system reliability and system resilience, and the potential for lower total costs. Challenges include integrating these new resources in a way that maintains system reliability, provides an equitable sharing of system costs, and avoids unbalanced impacts on different groups of customers, including those who install distributed energy resources (DERs) and low-income households who may be the least able to afford the transition.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Verification of a Modeling Toolkit for the Design of Building Electrical Distribution Systems

DC electrical distribution systems offer many potential advantages over their AC counterparts. They can facilitate easier integration with distributed energy resources, improve system energy efficiency by eliminating AC/DC converters at end-use devices (e.g., laptop chargers), and reduce installation material, time, and cost. However, DC electrical distribution systems present additional design considerations, largely resulting from potentially greater magnitude and variation in cable losses. Modeling and simulation are rarely used to design such systems. However, the greater dependency of DC system energy efficiency on design choices such as distribution voltages, architecture, and integration of PV and BESS suggests that modeling and simulation may be required. Such system performance analysis is currently not a standard practice, in part due to limited availability and validation of capable software tools. This paper characterizes the accuracy of a Modelica-based Building Electrical Efficiency Analysis Model (BEEAM) toolkit, as a precursor for validating its use to perform system performance analysis and inform design decisions. The study builds upon previous verification research by characterizing complete systems comprised of commercially available equipment, and providing a more detailed analysis of simulation results. Five lighting systems with varying electrical distribution architectures were designed using market-available equipment, installed in a laboratory environment, modeled using BEEAM, and simulated using three Modelica integrated development environments (IDEs). Simulated and measured results were compared to characterize toolkit accuracy. Initial results revealed that simulated performance was mostly within ±5% of measured system-level and device-level performance. While simulation results were not found to be dependent on the IDE, some Modelica compiler interoperability issues were identified. Although the BEEAM toolkit showed promise for the targeted use case, further work is needed to determine whether the demonstrated 5% accuracy is sufficient for making real-world design decisions, and for BEEAM to advance from an interesting research tool to one that can impact real-world building projects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimization-Based Deconfliction of Distribution System Applications

Power distribution systems are transitioning towards a future with large numbers of controllable grid-edge devices and distributed generation, as well as more complex operational objectives. This evolution requires a new distribution management approach, and modular applications can play a significant role. Thus, new strategies to coordinate independent applications with diverging operational goals are necessary. In this paper, we propose a novel optimization-based deconflictor to facilitate coordination in future advanced distribution management systems.

application deconfliction, power system optimizati↗

Resiliency of Distribution Systems Incorporating Asynchronous Information for System Restoration

Resiliency of distribution systems under extreme operating conditions is critical, especially when the utility is not available. With the large-scale deployment of distributed resources, it becomes possible to restore critical loads with local non-utility resources. Distribution system operators (DSOs) need to determine the critical loads to be restored, considering limited resources and distribution facilities. Several studies on resiliency have been conducted for the restoration of distribution systems. However, the inherent asynchronous characteristic on the information availability has not been incorporated. With incomplete and asynchronous information, decisions may be made that result in underutilization of generation resources. In this paper, a new distribution system restoration approach is proposed, considering uncertain devices and associated asynchronous information. It uses a two-module architecture that efficiently optimizes restoration actions using a binary linear programming model and evaluates their feasibility with unbalanced optimal power flow. Networked microgrids are included in the model. The IEEE 123-node test feeder is used for validation. Results show that asynchronous messages may affect the restoration actions significantly and the impacts can be mitigated by the proposed decision support tool for the DSOs.

Bedoya, Juan C.↗

Control mechanism for attenuation of thermal energy pulses using cold circulators in the cryogenic distribution system of fusion devices in tokamak configuration

Operation and control of superconducting (SC) magnets in the fusion devices having tokamak configuration opens up the domain of varying peak thermal energy environment as a function of time, commensurate with the plasma pulses. The varied thermal energy environment, thus propagated to upstream of the cooling system, is responsible for the system level instability of the overall cryogenic system. The cryogenic distribution system, the regime of first impact point, therefore, has to be tuned so as to stay at the nearly stable zone of operation. The configuration of the cryogenic distribution system, considered in the present study, involves a liquid helium (LHe) bath as a thermal buffer, LHe submerged heat exchangers and cold circulator apart from the valves for implementations of the precise controls. The cold circulator supplies the forced flow supercritical helium, used for the cooling of SC magnets. The transients of the thermal energy pulses can be attenuated in the cryogenic distribution system by various methodologies. One of the adopted methodologies in the present study is with the precise speed control of the cold circulators. The adopted methodology is applied to various configurations of arrangements of internal components in the distribution system for obtaining system responses with superior attenuation of energy pulses. The process simulation approach, assumptions, considered inputs and constraints, process modeling with different configuration as well as results to accomplish the control scheme for the attenuation of the thermal energy pulses are described.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coordinated voltage control and reactive power regulation between transmission and distribution systems

Systems and methods are described for coordinating volt-var control between sub-transmission and distribution systems. Distributed energy resources of a distribution system are aggregated into virtual power plants from which reactive power can optimally be dispatched to the sub-transmission system. A sub-transmission controller executes a volt-var AC optimal power flow optimisation function to minimize voltage fluctuations that might otherwise occur when coordinating with a distribution system having distributed energy resources. The distribution system can use a sensitivity matrix for regulating voltage at distribution feeders while fulfilling a transmission or sub-transmission system's demand requests.

Samaan, Nader A.↗

Standardizing Performance Metrics for Building-Level Electrical Distribution Systems

Building-level electrical distribution systems comprise a myriad of current-carrying equipment, conversion devices, and protection devices that deliver power from the utility or local distributed energy resources to end-use building loads. Electric power has traditionally been generated, transmitted, and distributed in alternating current (AC). However, the last decade has seen a significant increase in the integration of native direct current (DC) equipment that has elevated the importance of DC distribution systems. Numerous studies have comparatively examined the performance of various electrical distribution systems in buildings but have failed to achieve uniform conclusions, primarily because of a lack of consistent and analogous performance evaluation methods. This paper aims to fill this gap by providing a standard set of metrics and measurement boundaries to consistently evaluate the performance of AC, DC, or hybrid AC/DC electrical distribution systems. The efficacy of the proposed approach is evaluated on a representative medium-sized commercial office building model with AC distribution and an equivalent hybrid AC/DC and DC distribution model, wherein the AC distribution model is concluded to be the most efficient. The simulation results show variation in computed metrics with different selected boundaries that verify the effectiveness of the proposed approach in ensuring consistent computation of the performance of building-level electrical distribution systems. This paper provides an initial set of guidelines for building energy system stakeholders to adopt appropriate solutions, thus leading to more efficient energy systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Peak Load Management in Distribution Systems Using Legacy Utility Equipment and Distributed Energy Resources: Preprint

The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS—based on real-time optimal power flow—controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sensors with Intelligent Measurement Platform and Low-cost Equipment (SIMPLE) for Monitoring and Control of Medium Voltage Distribution Systems with High Penetration of Intermittent Distributed Energy Resources

The primary focus of the SIMPLE project was to develop, commission, test and introduce intelligent voltage and current sensor platform with enhanced characteristics (accuracy, bandwidth and harmonic range) and high measurement granularity for medium voltage distribution system monitoring, protection and control. The enhancements incorporated existing (commercially available) sensors and made them suitable for applications such as voltage regulation, frequency support, fault detection and location, distribution system state estimation, power quality measurements and electrical distribution network topology processing. The development of the intelligent sensor platform was driven by the need for high-fidelity monitoring and control of medium voltage distribution feeder to enable higher penetration of renewable resources and microgrid operation.

14 SOLAR ENERGY↗

Dynamical System Scaling of a Thermocline Thermal Storage System in the Thermal Energy Distribution System (TEDS) Facility

The purpose of this study was to develop a process to convert input signals from one facility into another by reflecting geometric and environmental settings. The Dynamic Energy Transport and Integration Laboratory (DETAIL) is one facility in development that aims to emulate the daily interactions among power production industry systems and be capable of receiving real-time data from those systems as inputs. To convert signals and ensure that the temporal sequences and magnitudes reflect the laboratory settings, the ability to scale and project data is essential. To demonstrate this ability, Dynamical System Scaling (a methodology that enables systems to scale and project or extrapolate datasets to desired environments while conserving the observed transient behavior based on first principles) was applied to DETAIL’s thermocline thermal storage system in the Thermal Energy Distribution System. The thermocline system was successfully scaled and a test case was conducted to generate a doubly accelerated energy charge and discharge in reference to past experimental data from the facility. The accelerated data were determined as able to conserve the amount of energy stored and the associated test boundary conditions were charge line maximum temperature, charge line velocity, and thermocline maximum temperature at 354 °C, 0.458 m/s, and 418 °C, respectively. The research results represented a case that required signals to be accelerated without altering the stored energy.

Yoshiura, Ramon (ORCID:0000000319781313)↗

The Cost of Distribution System Upgrades to Accommodate Increasing Penetrations of Distributed Photovoltaic Systems on Real Feeders in the United States

The increasing deployment of distributed photovoltaic systems (DPV) can impact operations at the distribution level and the transmission level of the electric grid. It is important to develop and implement forward-looking approaches for calculating distribution upgrade costs that can be used to inform system planning, market and tariff design, cost allocation, and other policymaking as penetration levels of DPV increase. Using a bottom-up approach that involves iterative hosting capacity analysis, this report calculates distribution upgrade costs as a function of DPV penetration on three real feeders - two in California and one in the Northeastern United States.

14 SOLAR ENERGY↗

Peak Load Management in Distribution Systems Using Legacy Utility Equipment and Distributed Energy Resources

The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS-based on real-time optimal power flow-controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimal PV Inverter Control in Distribution Systems via Data-Driven Distributionally Robust Optimization

Distribution systems with high penetration of uncertain solar generation call for advanced control strategies of photovoltaics (PVs) inverters. This paper proposes a data-driven distributionally robust optimization (DDDRO) approach to optimally controlling the PV inverters to improve the system operation performance under solar power uncertainties. In the proposed DDDRO approach, a Wasserstein ball-based method is proposed to construct the distributional ambiguity set to model the uncertainties of PV generation through partial observations of historical data without knowing exact probability distributions. We further reformulate the computationally intractable DDDRO model to a mixed integer second order cone programming (MISOCP) problem. The effectiveness and out-of-sample performance of the proposed approach have been demonstrated on a modified IEEE 33-node system. We conduct a comparative study to compare the proposed method with traditional chance constrained programming (CCP). It shows that the proposed DDDRO approach can provide a less conservative yet robust solution to minimize the worse-case expectation of the total network loss while maintaining nodal voltages in a secure range.

Xue, Yaosuo↗