Combined Heat and Power Technology Fact Sheet Series: Thermal Energy Storage

This fact sheet provides an overview of thermal energy storage (TES) technologies, which heat or cool a storage medium and, when needed, deliver the stored thermal energy to meet heating or cooling needs. TES systems are used in commercial buildings, industrial processes, and district energy installations to deliver stored thermal energy during peak demand periods, thereby reducing peak energy use. TES systems are often integrated with electric or absorption chillers to reduce peak electricity costs and, in the case of new construction, to reduce capital costs by optimizing chiller size. TES technologies can support sites that have either renewable or fossil power generation, including combined heat and power (CHP) installations. With CHP, TES can help optimize equipment size by reducing the required peak CHP thermal capacity and increasing annual CHP usage. TES can also provide turbine inlet cooling for gas turbines used in CHP applications, which increases power production in hot ambient conditions.

Combined Heat and Power, CHP, Thermal Energy, Tech↗

CityBES v2021

City Buildings, Energy, and Sustainability (CityBES) is a web-based data and computing platform, focusing on energy modeling and analysis of a city's building stock to support district or city-scale building energy efficiency programs. CityBES uses an international open data standard, CityGML, to represent and exchange 3D city models. CityBES employs EnergyPlus to simulate building energy use and savings from energy efficient retrofits. Other CityBES features include energy benchmarking, district heating and cooling system modeling, rooftop PV analysis, building performance visualization, heat resilience modeling, as well as urban scale mapping of microclimate and heat vulnerability at census tract level. Different from other tools, CityBES uses integrated open and standard 3D city building data and models each individual building using EnergyPlus. CityBES can be used by urban planners, city energy managers, building owners, utilities, energy consultants and researchers.

Hong, Tianzhen↗

Data-driven Quasi-static Surrogate Models for Nuclear-powered Integrated Energy Systems

The integration of nuclear power into energy systems presents a promising avenue to address the growing global energy demands while minimizing greenhouse gas emissions. In this paper, we introduce a data-driven quasi-static surrogate model for nuclear-powered Integrated Energy Systems (IES) that comprises various components, including a small modular reactor (SMR), steam manifold, balance of plant (BOP), high-temperature steam electrolysis (HTSE), and district heating (DH) system. Traditional physics-based models for these components often entail significant computational resource and time consumption, necessitating the development of efficient surrogate models. The development of a complete surrogate model for the IES involves the creation of individual surrogate models for each component, leveraging machine learning techniques and simulated data. These isolated surrogate models are subsequently integrated, enabling a holistic view of the IES and reducing the computational burden associated with detailed physics-based simulations. This paper outlines the development process, validation, and the performance evaluation of the surrogate models. The exceptional performance, with low root-mean-squared errors and R-squared scores of at least 99.8% across all individual surrogate models, underscores their accuracy and practical applicability. These results demonstrate the potential of these models to expedite the analysis of nuclear-powered IES, offering insights that can shape future research and development efforts.

08 HYDROGEN↗

An HPC-Based Hydrothermal Finite Element Simulator for Modeling Underground Geothermal Behavior with Example Simulations on The Treasure Island and UC Berkeley Campus

This submission contains the source code of the Hydrothermal Finite Element Simulator used for the Treasure Island and UC Berkeley campus geothermal simulation. It contains a report that summarizes the development and validation of this Hydrothermal Finite Element Simulator, with a case study on Treasure Island site. It also contains a report that investigates the feasibility of upgrading the existing campus energy delivery system at UC Berkeley to a fifth-generation district heating and cooling system that includes geothermal heat/cold storage.

15 GEOTHERMAL ENERGY↗

Advanced Energy Approaches for Mixed-Use Developments in the Front Range Urban Corridor

The primary objective of the document is to present example technical approaches and strategies that planners and developers can reference for all-electric mixed-use developments in the Rocky Mountain Front Range urban corridor that are considering advanced energy performance goals such as high levels of energy efficiency and renewable integration. The strategies are tailored toward the vision for a zero energy, all-electric, district thermal system-connected starter district. In this example, on-site solar generation is emphasized as a strategy that can be combined with electrical and thermal energy storage for enhanced community resilience and demand flexibility. Opportunities for utilizing or adapting these strategies include: sharing with vertical developers for potential integration of strategies into vertical design guidelines; incorporation into Owner Project Requirements (OPRs); providing example strategies to design teams as a starting point for design; informing structure of agenda for a building design charrette; comparing building designs to example strategies at various points in the design process to evaluate design progression. While the technical strategies outlined in this document can help inform the development of guidelines for projects in the Front Range urban corridor, this document does not set requirements for any rating, certification, program, or policy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of Geothermal District Heating System on Flexibility of Microgrid in Tuttle, Oklahoma

Flexibility is the capability of the power grid to maintain a balance between electricity generation and variable demand. This study presents preliminary results evaluating the impact of geothermal district heating systems on the flexibility of microgrid in Tuttle, Oklahoma. Heating demand profiles were modeled using EnergyPlus for the district that includes two schools and 250 single-family houses. Then, geothermal energy production was modeled using GEOPHIRES to estimate how much heating demand in the district can be supplied by five different geothermal system scenarios. The results indicated that geothermal energy production varied depending on the resource temperature at different depths, system configurations, and flow rates. For the grid flexibility analysis, electricity consumptions in the five geothermal systems were estimated for pump operations to circulate water from the wells to radiators, while electricity consumption by air-source heat pump in the base case was estimated to supply the same heating load. Electricity consumption in the geothermal systems was significantly lower than those in base cases. The electricity saved by the geothermal system was then incorporated into the microgrid electrical load profiles where variable renewable electricity generation is significantly high. The results visually showed that geothermal district heating system can improve grid flexibility as a baseload during the winter season. The results also highlighted potential opportunities to save energy costs that will be further analyzed in future study.

Cambium↗

The value of integrating a geothermal district heating system into a microgrid

As electrical grids increasingly rely on variable renewable energy, maintaining reliability and cost efficiency becomes more complex. To address these challenges, this study analyzed the integration of geothermal district heating as a grid-responsive thermal resource within a microgrid in Tuttle, Oklahoma. Building energy modeling using EnergyPlus estimated annual district heating demand at 2.9 GWh, with a peak load of 2.8 MW th . Techno-economic analyses were conducted to meet the heating demand under three geothermal scenarios, varying by production depth, flow rate, and thermal output, each supplemented by natural gas peaking boilers. In parallel, equivalent electrical load profiles were developed using typical coefficients of performance (COPs) for air-source heat pumps and electric boilers to establish an electrified baseline scenario. A complete end-use electrical load profile was also developed for the microgrid using Cambium dataset. The modeling results demonstrated reliable and economic operation of the geothermal systems over 30 years, with COPs ranging from 2.6 to 8.9 and the lowest levelized heating cost at $\$$54.6/MWh. Geothermal integration reduced electricity consumption by up to 94.7 % compared to the non-geothermal base case, yielding annual energy savings of up to $\$$803 k. Avoided grid costs ranged from $\$$65 k–$\$$147 k per year, with individual events avoiding up to $\$$4,863 per hour. Grid-responsive operation further reduced wholesale energy costs by 53–56 %. These findings demonstrate geothermal heating, traditionally treated as a non-grid-responsive thermal resource, can be reconfigured to support dynamic grid services, offering a scalable pathway to enhance reliability and reduce costs in renewable-rich microgrids and district heating networks.

15 GEOTHERMAL ENERGY↗

Impact of Geothermal District Heating System on Flexibility of Microgrid in Tuttle, Oklahoma: Preprint

Flexibility is the capability of the power grid to maintain a balance between electricity generation and variable demand. This study presents preliminary results evaluating the impact of geothermal district heating systems on the flexibility of a conceptual microgrid in Tuttle, Oklahoma. Heating demand profiles were modeled using EnergyPlus for the district that includes two schools and 250 single-family houses. Then, geothermal energy production was modeled using GEOPHIRES to estimate how much heating demand in the district can be supplied by five different geothermal system scenarios. The results indicated that geothermal energy production varied depending on the resource temperature at different depths, system configurations, and flow rates. For the grid flexibility analysis, electricity consumptions in the five geothermal systems were estimated for pump operations to circulate water from the wells to radiators, while electricity consumption by air-source heat pump in the base case was estimated to supply the same heating load. Electricity consumption in the geothermal systems was significantly lower than those in base cases. The electricity saved by the geothermal system was then incorporated into the microgrid electrical load profiles where variable renewable electricity generation is significantly high. The results visually showed that geothermal district heating system can improve grid flexibility as a baseload during the winter season. The results also highlighted potential opportunities to save energy costs that will be further analyzed in future study.

Cambium↗

Development and Preliminary Analysis of a U.S. Geothermal Heat Pump Installation Database

This paper seeks to addresses the significant gap in the literature regarding the installation and adoption of geothermal heat pump (GHP) systems in the United States. While the "2021 U.S. Geothermal Power Production and District Heating Market Report" published by the National Renewable Energy Laboratory (NREL) focused on direct-use geothermal district heating systems, it did not include an analysis of GHP installations (Robins et al. 2021). To bridge this gap, NREL has compiled a novel database currently containing 70,470 records of GHP installations, primarily sourced from state well permits and small-scale studies. Our methodology emphasizes the collection, cleaning, and standardization of data, addressing challenges such as inconsistent reporting formats and privacy concerns. Despite limitations in data on capacity, costs, and performance, our preliminary geospatial analysis reveals insights into the distribution of GHP systems across urban and rural areas and climate zones. The paper highlights the importance of publicly accessible data for advancing GHP technology adoption with a discussion of existing data sources and their limitations, advocating for improved collaboration between NREL and industry stakeholders.

data collection↗

Design, modeling and simulation of nuclear-powered integrated energy systems with cascaded heating applications

Nuclear-renewable integrated energy systems (IES) consist of a variety of energy generation and conversion technologies and can be used to meet heterogeneous end uses (e.g., electricity, heat, and cooling demands). In addition to supply-demand balance, end-use heat demands usually require heat supply of certain temperature ranges. The effective and efficient utilization of heat produced within an IES is, therefore, a critical challenge. Here, this paper examines design options of an IES that includes heating processes of multiple temperature grades. We investigate a cascaded design configuration, where the remaining residual heat after high-grade heating processes [e.g., hydrogen production through high-temperature steam electrolysis (HTSE)] is recovered to meet the low-grade heating needs [e.g., district heating (DH)]. Additionally, a thermal energy storage system is integrated into the DH system to address the imbalance between heat supply and demand. This paper primarily focuses on the design and modeling of the proposed system and evaluates its operation with a 24-h transient process simulation using a DH demand profile with hourly resolution. The results indicate that the residual heat from the HTSE exhaust is insufficient for the DH demand, and additional topping heat directly from the reactor process steam is needed. Furthermore, the inclusion of thermal energy storage within the DH system provides the necessary balance between thermal generation and demand, thereby ensuring a consistent rated temperature of the DH supply water. This approach helps minimize the control actions needed on the reactor side.

08 HYDROGEN↗

Development of a metamodelling framework for building energy models with application to fifth-generation district heating and cooling networks

Fully defined physics-based building energy models can accurately represent building systems; however, generating models based on high-level parameters is time consuming and simulation time of complex models can be slow. This article discusses the development of a Metamodelling Framework to create metamodels from a building energy modelling dataset. The framework generates metamodels using either linear regression, random forests, or support vector regressions. A fifth-generation district heating and cooling system analysis use case was used to motivate the development of the framework. The use case required quick and accurate representations of annual building loads reported hourly. Typical annual building modelling approaches can result in a runtime of 10 min. The metamodels runtime was reduced to less than 10 s to load and run an annual simulation with user-defined covariates. The results of the metamodel performance and an abbreviated topology analysis based on the motivating use case will be presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-timescale operations of nuclear-renewable hybrid energy systems for reserve and thermal product provision

In this paper, an optimal operation strategy of a nuclear-renewable hybrid energy system (N-R HES), in conjunction with a district heating network, is developed within a comprehensive multi-timescale electricity market framework. The grid-connected N-R HES is simulated to explore the capabilities and benefits of N-R HES of providing energy products, different reserve products, and thermal products. An N-R HES optimization and control strategy is formulated to exploit the benefits from the hybrid energy system in terms of both energy and ancillary services. A case study is performed on the customized NREL-118 bus test system with high renewable penetrations, based on a multi-timescale (i.e., three-cycle) production cost model. Both day-ahead and real-time market clearing prices are determined from the market model simulation. In conclusion, the results show that the N-R HES can contribute to the reserve requirements and also meet the thermal load, thereby increasing the economic efficiency of N-R HES (with increased revenue ranging from 1.55% to 35.25% at certain cases) compared to the baseline case where reserve and thermal power exports are not optimized.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Proceedings of the Alternate Energy Systems Seminar

The Alternative Energy Systems Seminar was held on March 30, 1978, and was sponsored jointly be the Southwest District Office of the U.S. Department of Energy and JPL. The seminar was an experiment in information exchange with the aim of presenting, in a single day, status and prospects for a number of advanced energy systems to a diverse, largely nontechnical audience, and to solicit post-seminar responses from that audience as to the seminar's usefulness. The major systems presented are: (1) Solar Photovoltaic; (2) Geothermal; (3) Cogeneration Power; (4) Solar Thermal; (5) Solar Heating and Cooling; (6) Wind Energy; and (7) Systems Considerations.

Source record↗

Tunisia Renewable Energy Project systems description report

In 1979, the Agency for International Development (AID) initiated a renewable energy project with the Government of Tunisia to develop an institutional capability to plan and institute renewable energy technologies in a rural area. The specific objective of the district energy applications subproject was to demonstrate solar and wind energy systems in a rural village setting. The NASA Lewis Research Center was asked by the AID Near East Bureau to manage and implement this subproject. This report describes the project and gives detailed desciptions of the various systems.

Scudder, L. R.↗

Thermo-hydro-mechanical analysis of subsurface ice-based thermal energy storage

Ice-based thermal energy storage systems are widely utilized for cooling and managing peak electrical demand globally, offering daily or weekly storage capabilities for both individual homes and larger office buildings. However, scaling these systems for district-level cooling or integrating them with renewable energy sources presents challenges, especially in accommodating larger volumes and addressing seasonal storage requirements in densely populated urban areas. This paper proposes a novel solution by evaluating subsurface ice-based thermal energy storage, in which the underground is subjected to seasonal freeze/thaw cycles. However, these cycles may influence ground behavior, affecting pore pressure and inducing ground movement. To systematically investigate these challenges, we enhance the TOUGH-FLAC simulator by integrating water/ice phase change capabilities and updating the effective stress–strain constitutive relation. Both modifications are validated against analytical solutions or experimental data. Through numerical simulations spanning a decade with ten seasonal freeze/thaw cycles, we evaluate the performance and long-term stability of a generic subsurface ice-based thermal energy storage system, considering factors such as ground permeability, freezing pipe spacing, freeze/thaw damage, and glycol solution temperature. The simulations indicate that ice formation induces pore pressure variations that drive seasonal surface heave and settlement, controlled by ground permeability, pipe spacing, and glycol solution temperature, along with tensile and localized shear deformation around freeze pipes. This highlights the need for accurate ground property characterization and geomechanical analysis for subsurface ice-based thermal energy storage.

Ground freezing↗

U.S. Department of Energy Solar District Cup Collegiate Design Competition

The Solar District Cup is a multidisciplinary collegiate competition that challenges student teams to design and model standalone solar and solar-plus-storage systems for multiple buildings on a local electrical distribution network, such as a college campus, across a development, or in a district. Students learn cross-cutting skills that prepare them to become part of the next generation of the distributed energy workforce. Student teams act as renewable energy developers proposing to solar and solar-plus-storage system requests. Students, faculty, and prospective employers can benefit from knowing about this program and what students learn--either immediately as participants, mentors, or judges, or as potential employers of Solar District Cup alumni. RE+ is also one of our competition partners.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Synopsis of NREL's Automated Mobility District (AMD) Research Program and Associated Publications

An automated mobility district (AMD) envisions a system of integrated mobility options that serves major activity centers such as campuses, central business districts, and large medical facilities. The National Renewable Energy Laboratory (NREL) has been investigating the implementation prospects for fully automated passenger transport systems that are deployed to operate within dense urban settings. This document provides a synopsis of findings revealed over the last three phases of work, which have yielded insights into the creation and management of AMDs anticipated to use automated vehicle (AV) technology over the next decade. Phase I and Phase II tracked the deployment and lessons learned from 10 early-stage demonstrations of automated shuttle deployments, and their associated insights into the challenges for automated driving systems to achieve safe operations within district-scale deployments. Phase III began in-depth investigations of critical subsystem components, as automation, electrification, and on-demand service continue to converge within initial AMD operations. These directed studies focus on elements of electrification, curbfront/station management, the role of infrastructure sensing, and overall integration of AMD safety management in central, simultaneous coordination of multiple AMD fleets. Future research in AMDs includes systems engineering methodology (more frequently referred to as "digital twins") for planning, design, testing, and ongoing operation of AMDs; location (or co-location) of management functions; and human supervision and passenger communications for safety and security in unattended vehicles. The synopsis references the foundational research products (papers and presentations) that have been published through conference proceedings, journal articles, and NREL reports.

33 ADVANCED PROPULSION SYSTEMS↗

Techno-Economic Simulation Results Using dGeo for EGS-Based District Heating in the Northeastern United States

This dataset presents the results of techno-economic simulations performed using the Distributed Geothermal Market Demand Model (dGeo) to evaluate the feasibility of Enhanced Geothermal Systems (EGS)-based district heating in the Northeastern United States. Developed by the National Renewable Energy Laboratory (NREL), dGeo is a geospatially resolved, bottom-up modeling framework designed to explore the deployment potential of geothermal distributed energy resources. The dataset, created as part of the Cornell EGS Ground-Truthing Project, provides census tract-level data that includes inputs and outputs such as thermal demand, road length, energy prices, geothermal system sizing, annual energy contributions from geothermal and natural gas peaking boilers, system capital costs (CAPEX), operation and maintenance costs (OPEX), and the levelized cost of heat (LCOH). Key simulation parameters include geothermal gradients, measured well depths, production temperatures, and district heating piping lengths based on S1400 neighborhood road lengths. The simulations assume a target bottom hole temperature of 80C and the development of new district heating networks in each census tract.

15 GEOTHERMAL ENERGY↗