Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Rate Calculations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Dosimetry and cancer risk estimations for different radiation protection solutions at decommissioning a contaminated nuclear power plant site

Contaminated sediments originating from dredging activities in a nuclear power plant site were placed in a pond, which has to be taken into consideration during the future decommissioning process. The sediments have to be handled to free release the site. The radionuclides Co-60 and Cs-137 were identified and the activity concentrations (Bq/kg) were quantified in the range of 10–6000 and 5–50 Bq kg -1 , respectively. The absorbed dose rate to individuals of various ages and sex present at the site of the dry pond area was estimated. The radiological impact in terms of lifetime attributable risk (LAR) and effective dose were calculated. For a 30-year-old male exposed during one year without any action regarding the sediments in the dried out pond, the LAR was predicted to be 0.0027, which recalculated to effective dose corresponds to 7.6 mSv year -1 . The calculations show that countermeasures will be needed for the contaminated site.

61 RADIATION PROTECTION AND DOSIMETRY↗

Software Validation Work With The ZPPR-15 Data

The analysis activities for fast reactors involve using many different pieces of software that are relied upon for their predictive capabilities. For this software to be considered reliable, documented proof that the predictions of the software are accurate is required. In this manuscript, the validation work that covers some of the Argonne software used in fast reactor design activities is discussed and displayed. This validation work includes neutron and gamma flux distributions, reaction rate distributions, and reactivity worth. In an ideal world, a reactor development program would have access to a comprehensive set of experimental facilities to help inform the design aspects of the reactor itself. While thermal-hydraulics experiments, and to a limited degree mechanical experiments, can be carried out today for validation needs, neutronics related experimental facilities are rather impractical because of the lack of experimental facilities. Given the desired time table for construction of new reactors, the reconstitution or creation of new neutronic experimental facilities is untenable and thus those reactor development programs must rely upon any available experimental measurements that are qualitatively similar to the design. While a methodology has been proposed to assess the similarity between the past experimental measurements and the reactor itself, that aspect is beyond the scope of this manuscript. In this manuscript, the focus is entirely placed on the analysis results for a series of experiments carried out at the ZPPR facility in Idaho in the mid-1980s. In this regard, this manuscript only shows the validation of the stated neutronics software for specific loadings of the ZPPR reactor. Because of the fuel form, its proposed enrichment, and the material content of the reactor core, the ZPPR-15 experiments were identified as potential validation data for the reactor. The ZPPR-15 experiments were intended as mockups of a 330 MWe Integral Fast Reactor program which was a follow on program to the Clinch River Breeder Reactor. In the ZPPR-15 series of experiments, measurements of the neutron spectrum, control rod worth, sodium void worth, foil reaction rate distributions, Doppler worth of heated samples, gamma dose, and axial expansion worth were all carried out and published. In many cases, these reactivity coefficients are good candidates to validate the reactivity coefficient calculation scheme used by the analysis software and included in the safety analysis activities of fast reactor development projects today. This manuscript discusses the modeling methodology and accuracy of the calculated experimental results using the LANL software MCNP and the ANL software package ARC (Argonne Reactor Codes). As will be shown, for many of the experimental measurements, the two software packages are found to be good predictive analysis tools for those experiments. In other cases, problems with the analysis methodology or underlying cross section data are exposed which indicates where predictive analysis is not as reliable. Finally, in some of the measurements the conclusion is reached that the experimental measurement cannot be reproduced with the analysis software as it is simply too difficult.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Software Validation Work With The ZPPR-15 Data

The analysis activities for fast reactors involve using many different pieces of software that are relied upon for their predictive capabilities. For this software to be considered reliable, documented proof that the predictions of the software are accurate is required. In this manuscript, the validation work that covers some of the Argonne software used in fast reactor design activities is discussed and displayed. This validation work includes neutron and gamma flux distributions, reaction rate distributions, and reactivity worth. In an ideal world, a reactor development program would have access to a comprehensive set of experimental facilities to help inform the design aspects of the reactor itself. While thermal-hydraulics experiments, and to a limited degree mechanical experiments, can be carried out today for validation needs, neutronics related experimental facilities are rather impractical because of the lack of experimental facilities. Given the desired time table for construction of new reactors, the reconstitution or creation of new neutronic experimental facilities is untenable and thus those reactor development programs must rely upon any available experimental measurements that are qualitatively similar to the design. While a methodology has been proposed to assess the similarity between the past experimental measurements and the reactor itself, that aspect is beyond the scope of this manuscript. In this manuscript, the focus is entirely placed on the analysis results for a series of experiments carried out at the ZPPR facility in Idaho in the mid-1980s. In this regard, this manuscript only shows the validation of the stated neutronics software for specific loadings of the ZPPR reactor. Because of the fuel form, its proposed enrichment, and the material content of the reactor core, the ZPPR-15 experiments were identified as potential validation data for the reactor. The ZPPR-15 experiments were intended as mockups of a 330 MWe Integral Fast Reactor program which was a follow on program to the Clinch River Breeder Reactor. In the ZPPR-15 series of experiments, measurements of the neutron spectrum, control rod worth, sodium void worth, foil reaction rate distributions, Doppler worth of heated samples, gamma dose, and axial expansion worth were all carried out and published. In many cases, these reactivity coefficients are good candidates to validate the reactivity coefficient calculation scheme used by the analysis software and included in the safety analysis activities of fast reactor development projects today. This manuscript discusses the modeling methodology and accuracy of the calculated experimental results using the LANL software MCNP and the ANL software package ARC (Argonne Reactor Codes). As will be shown, for many of the experimental measurements, the two software packages are found to be good predictive analysis tools for those experiments. In other cases, problems with the analysis methodology or underlying cross section data are exposed which indicates where predictive analysis is not as reliable. Finally, in some of the measurements the conclusion is reached that the experimental measurement cannot be reproduced with the analysis software as it is simply too difficult.

Aliberti, Gerardo↗

Idaho National Laboratory CY 2024 National Emission Standards for Hazardous Air Pollutants Analysis, Methodology, and Results for Radionuclides

This report documents the methodology and results for calculating the effective dose equivalent (EDE) to the maximally exposed individual (MEI) from atmospheric radionuclide emissions from Idaho National Laboratory (INL) sources in Calendar Year (CY) 2024. The calculations were performed in accordance with requirements in Code of Federal Regulations (CFR), Title 40, “Protection of the Environment,” Part 61, “National Emission Standards for Hazardous Air Pollutants (NESHAPs),” Subpart H, “National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities” (40 CFR 61, Subpart H). UDFs were calculated using the computer model CAP88-PC for unit (1 Ci/yr) emission rates at INL Site facilities and INL in-town (Idaho Falls) facilities and stored in Microsoft Access databases. The UDFs—in this case, mrem/Ci—were then combined with radionuclide-specific release (emission) rates for each facility-specific source to compute doses at predetermined public receptor locations, including the MEI locations. This report contains the dose results and a description of the methodology and tools used to compute the doses.

07 - ISOTOPES AND RADIATION SOURCES↗

Activation estimates of the RHIC beam dump

In anticipation of the expiration of the RHIC ASE in December 2025 and the need to demonstrate compliance with nuclear facility rule (10CFR830), this study quantifies the radionuclide inventory and respective activity at the beam dumps by simulating a period of five years of operation using conservative assumptions. Simulations were performed with the Monte Carlo particle transport and interaction code FLUKA and its dosimetry results were compared with measured dose rate data, showing good agreement. The beam dump was deemed to constitute the main hotspot of residual radiation and also representative of a worst case scenario in terms of induced activation. The activation levels calculated indicate that the RHIC tunnel will be well below the thresholds of a DOE’s category-3 nuclear facility classification.

43 PARTICLE ACCELERATORS↗

A physiologically based pharmacokinetic (PBPK) model to align dosimetry of the isobutyl metabolic series in rats and humans

Here, we developed a physiologically based pharmacokinetic (PBPK) model in rats and humans for the isobutyl metabolic series including isobutyl acetate, isobutanol, isobutyraldehyde, and isobutyric acid. Chemical manufactures routinely use these compounds as solvents, for chemical synthesis, as potential biofuels, de-icing fluids, and additives for food and/or fragrance in consumer products. Human exposure to isobutyl compounds can occur through inhalation or oral routes. We previously developed a PBPK model for the propyl metabolic series and utilized it as a framework to create the isobutyl PBPK model due to the chemical similarities between the two series. To support model development, we measured in vitro metabolism of isobutyl acetate in rat and human blood and liver S9 fractions. Compared to rats, humans demonstrated faster isobutyl acetate hydrolysis in liver S9 fractions, while the hydrolysis rates in blood were similar between the two species. We used concentrations of isobutyl compounds measured in air and blood from rats exposed to isobutyl acetate and isobutanol as well as other published data to further parameterize the model. Following exposure to either isobutyl acetate or isobutanol, we observed isobutanol concentrations highest among the isobutyl compounds in the blood of rats. Overall, the model accurately predicts measured time course concentrations of isobutyl acetate, isobutanol, and isobutyric acid in available data in rats and humans. Sensitivity analyses identified alveolar ventilation rates, isobutyl metabolism rates, and cardiac output as the most sensitive parameters affecting concentrations of isobutyl compounds in blood. The isobutyl PBPK model enables comparisons of internal dose metrics across various isobutyl compound exposures and species and allows for calculation of equivalent external exposures that result in the same dose metric. Regulators can employ this PBPK model to predict and align internal dose metrics of isobutyl compounds for risk assessment purposes.

2-methyl-1-propanol↗

Use of the Manuela 3D/Radiation Scanning Tool at Nuclear Facilities - 20437

Licensees, facility operators and decommissioning contractors have a need for comprehensive, accurate and precise radiological and topographical data to plan and execute safe and efficient Decontamination and Decommissioning (D and D) projects. Traditional approaches rely greatly upon labor and administratively intensive data collection methods that require considerable time and effort to glean the relevant data to plan and perform work in a radiological work area. Orano Decommissioning Services has developed and utilized at French nuclear facilities a lightweight portable scanning instrument called MANUELA (Mobile Apparatus for Nuclear Expertise Localization Assistance). Recently Orano conducted demonstrations at two United States nuclear facilities using MANUELA that may prove useful in areas of the fuel cycle including: - ALARA (As Low As Reasonably Achievable) planning during facility operations; - Scoping and site characterization during the D and D planning phase; - Remedial action support during active decommissioning work; - Radiation and modeling planning for plant modifications; - Support Final Status Survey and demonstration of 'end state' compliance for license termination. MANUELA is currently being evaluated for use during decommissioning of nuclear facilities and could aide in demonstrating compliance with end state criteria after decommissioning. Of particular interest are decommissioning projects planned for various sites across the United States. Most of these sites present unique challenges and opportunities to safely and efficiently decommission in a regulatory compliant manner. The two demonstration site's current conditions of relatively low radiation levels inside containment proved to be ideal platforms to deploy the MANUELA instrument for evaluation of the complex geometries typically found in a nuclear facility. The MANUELA instrument was able to precisely identify local hot spots of the reactor system's primary equipment and was able to simultaneously overlay the dose information onto the scanned 3D images. Using data like this, a licensee would be able to make informed technical and personnel decisions on methods to remediate, shield or properly dispose of the radioactive source term. MANUELA can be used throughout the decommissioning process to validate progress and continue to refine the work activities to optimize the efforts of the crew which reduces downtime waiting for survey results, whereas traditional survey methodology relies on a physical survey to be performed and the data transcribed onto survey maps that are only two dimensional. The traditional format tends to be inaccurate and difficult to interpret the precise location(s) of hot spots or generalized dose rates. The resultant scan also allows the user to know the exact extent of the survey versus transposing information onto a map with only a portion of the map area scanned. MANUELA also compiles all of the relevant survey data into a downloadable table format which includes the measurement identification number, time stamp, point space location on the XYZ plane, and the dose rate value. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results of a Multi-institutional Phase 2 Clinical Trial for 4DCT-ventilation Functional Avoidance Thoracic Radiation Therapy

Radiation pneumonitis remains a major limitation in the radiation therapy treatment of patients with lung cancer. Functional avoidance radiation therapy uses functional imaging to reduce pulmonary toxic effects by designing radiation therapy plans that reduce doses to functional regions of the lung. Lung functional imaging has been developed that uses 4-dimensional computed tomography (4DCT) imaging to calculate 4DCT-based lung ventilation (4DCT-ventilation). A phase 2 multicenter study was initiated to evaluate 4DCT-ventilation functional avoidance radiation therapy. The study hypothesis was that functional avoidance radiation therapy could reduce the rate of grade ≥2 radiation pneumonitis to 12% compared with a 25% historical rate, with the trial being positive if ≤16.4% of patients experienced grade ≥2 pneumonitis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determination of X-ray detection limit and applications in perovskite X-ray detectors

X-ray detection limit and sensitivity are important figure of merits for perovskite X-ray detectors, but literatures lack a valid mathematic expression for determining the lower limit of detection for a perovskite X-ray detector. In this work, we present a thorough analysis and new method for X-ray detection limit determination based on a statistical model that correlates the dark current and the X-ray induced photocurrent with the detection limit. The detection limit can be calculated through the measurement of dark current and sensitivity with an easy-to-follow practice. Alternatively, the detection limit may also be obtained by the measurement of dark current and photocurrent when repeatedly lowering the X-ray dose rate. While the material quality is critical, we show that the device architecture and working mode also have a significant influence on the sensitivity and the detection limit. Our work establishes a fair comparison metrics for material and detector development.

47 OTHER INSTRUMENTATION↗

Cross-Code Verification of Neutronics Analysis Tools at INL Applied for 238 Pu Production in the Advanced Test Reactor

Here, analyses are completed for experiments prior to experiment irradiation in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). Various codes are used to qualify all experiments planned for insertion in the reactor, thereby ensuring that all safety and programmatic requirements are satisfied preirradiation. Among the common experiment analysis tools at INL are MCNP5 coupled to ORIGEN2 (MOPY) and MC21. MOPY uses MCNP5 for transport calculations along with calculations for fluxes and select reaction rates, and then ORIGEN2 handles the step-by-step and postirradiation depletion. MC21 handles all in-reactor transport and step-by-step, during-irradiation, depletion calculations, and then ORIGEN (SCALE 6.2.3) is used for decay and dose calculations postirradiation. The MOPY results, along with those obtained via two variations of the MC21 model, were compared in terms of 238 Pu production in the ATR’s H10 position. For the MOPY model, the MC21 model utilizing the HELIOS-based fission product (FP) library, and the MC21 model utilizing the expanded 1300 FP library, the during-cycle irradiation in-core heating results were sufficiently equivalent; however, the MOPY model and the MC21 model with the HELIOS library showed some differences relating to the respective FP libraries. Ultimately, the MC21 model with a 1300 FP library produced the most consistent results throughout the cycle, whereas the MC21 model that utilized the (smaller) HELIOS library was able to handle during-irradiation analysis but lacked certain short-lived FPs that significantly contributed to the total decay heat at shutdown. MOPY, on the other hand, was found to overpredict fission gas production, as a result of limitations in the ORIGEN2 code.

ATR↗

HBU R and D Cask Transportation Options - 20436

The TN-32B HBU Demonstration Cask was successfully loaded in November 2017 with 32 high burnup (HBU) fuel assemblies at Dominion's North Anna Nuclear Plant and is collecting thermal data as intended. The first two phases of this very successful project sponsored by DOE and EPRI was designed to collect thermal data of HBU fuel to support extended storage. The next phase of the project requires the cask be licensed for transportation so the cask can be relocated to a site (to be determined by DOE) to facilitate long term monitoring and additional research on the fuel. This is a unique challenge given the constraints that exist for this particular bolted metal cask. The TN-32B cask is a 234,288 lb. (storage configuration) dry storage system that was selected for this project and it was modified to provide thermal data and the ability to collect gas samples after loading. Several major issues must be addressed to obtain the transport license including protecting the seven lid penetrations that were made to allow for the insertion of the thermocouples into the selected fuel assemblies after the cask was loaded. In order to protect the integrity of the research, the payload must remain as is. Therefore, the cask system must be placed into the transportation configuration without rewetting the fuel, replacing the lid and without removing the thermocouple instrumentation that is currently installed. A critical portion of the design and engineering that was performed in the first two phases of the project was to ensure that future transportation of the cask was integrated into the approach. Efforts were made to accommodate requirements such as containment boundary leakage testing, installation of impact limiter brackets and lid bolts suitable for transportation. Due to the science requirements of the project, the fuel selected was intended to yield the highest payload temperatures permitted to provide the greatest value for the researchers. This resulted in higher than usual external dose rates and surface temperatures that warranted performing as much preparatory work prior to cask loading to ensure ALARA and personnel safety to the greatest extent practical rather than working on a loaded cask. In addition to the work performed prior to cask load, there are remaining challenges such as protecting the modified lid, design and fabrication of impact limiters that accommodate the modified cask lid and preserving the thermocouple connections for continued monitoring. The project team is currently performing the necessary calculations, engineering, and design to support the licensing as required by the US NRC. Pre-application meetings have been held to inform the regulator of the planned technical approach to ensure compliance with the applicable regulations. The current plan is to obtain the transportation C of C by the end of 2021. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Review of Variables Impacting the Indoor Inhalation Radon Equilibrium Factor (FEQ)

With radon and its daughter products estimated as the second leading cause of lung cancer in the United States, it is imperative to understand their relative equilibrium inside commercial, community, and residential dwellings. The radon indoor inhalation fractional equilibrium factor (F eq ) quantifies the disequilibrium between radon and its progeny in indoor air, and recent advances have shown how air exchange rates (ACH) influence F eq . These numerically derived ACH-dependent F eq values are incorporated into the U.S. EPA's Radon Vapor Intrusion Screening Level (RVISL) calculator, which assists risk assessors in evaluating radon exposure. To advance the risk assessment science of actinon (Rn-219), thoron (Rn-220), and radon (Rn-222), the impact of variables such as indoor aerosol concentration and composition, outdoor air quality, household-specific characteristics, and environmental/meteorological conditions on the F eq must be examined. The primary objective of this research is to analyze these additional variables to determine the usefulness of incorporating such adjustment factors into the RVISL calculator and to identify areas of future research. Studies regarding the influence of these parameters are presented along with recommendations regarding the adjustment of the numerically derived F eq value. For example, elevated indoor aerosol concentrations, such as those originating from outdoor PM 2.5 or cigarette smoke, increase the abundance of accumulation- mode particles indoors, which in turn raises F eq values by facilitating the attachment of radon progeny to these aerosols. Smoking increases both the bronchial dose and F eq , while regions with high smog levels demonstrate the impact of regional air quality on F eq . In contrast, air cleaning systems and purifiers have been shown to reduce the F eq , suggesting that these systems could help mitigate radon exposure. Additionally, higher F eq values are typically observed during winter when ventilation rates are lower. This paper presents adjustment factors that may be applied to the RVISL F eq , emphasizing the need for further research to refine these variables and ensure accurate risk assessments in diverse environments. Applying these adjustment factors will minimize calculator over- and underestimations, providing a more accurate representation of the real-world risk associated with radon.

54 ENVIRONMENTAL SCIENCES↗

SCALE Shielding Calculations for Advanced Reactor Accident Scenarios

The study results presented in this paper demonstrate the capabilities of the SCALE computer code for non–light water reactor (non-LWR) radiation source term and shielding calculations in support of the U.S. Nuclear Regulatory Commission non-LWR fuel cycle demonstration project. Representative non-LWR types, including the sodium-cooled fast reactor (SFR), the molten salt reactor (MSR), and the heat pipe microreactor (HPMR), were analyzed to evaluate dose rates associated with postulated accident scenarios (SFR and MSR), reactor operation (MSR and HPMR), and fuel self-protecting characteristics (HPMR). New features were implemented in SCALE depletion codes to better simulate MSR operation.

MSR↗

Pressurization Analysis for Heating of a Screw Top Utility Can Loaded With Plutonium Oxide Powder by a 1273 K Fire

The documented safety analysis for the Savannah River National Laboratory (SRNL) evaluates the consequences of a postulated 1273 K fire in a glovebox. The radiological dose consequences for a pressurized release of plutonium oxide powder during such a fire depend on the maximum pressure that is attained inside the oxide storage containers. The oxide storage configuration selected for analysis is can/bag/can, comprised of oxide powder inside an 8.38 × 10 -6 m 3 stainless steel B vial inside 0.006 kg of polyethylene bagging inside a one-quart screw top utility can of the type commonly used to package solvents or rubber cements. To enable evaluation of the dose consequences, temperature and pressure transients have been calculated for exposure of a typical set of storage containers to the fire. The pressurization analysis credits venting to and from the B vial but does not credit venting or leakage from the can. Due to the low rate of venting from the B vial into the can gas space, the can pressure is nearly independent of the B vial pressure. Calculated maximum pressures are compared to the utility can burst pressure. In lieu of a structural analysis of the utility cans, burst pressures and leakage rates were measured using compressed nitrogen gas. The measured gauge burst pressure was 0.250 ± 0.043 MPa. The measured burst pressures are lower than the calculated maximum pressure due to fire exposure, indicating that the utility cans could burst during exposure to a 1273 K fire.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Initial Testing of Alkaline Earth Metal Ion Absorption on Crystalline Silicotitanate - 20440

The Tank Closure Cesium Removal process at the Savannah River Site (SRS) has processed aqueous tank waste using the inorganic ion exchange media IONSIV{sup TM} R9120-Ba (which is also known as Crystalline Silicotitanate (CST)). Salt-cake in Tank 10H at SRS was dissolved and processed through filters and ion exchange columns. The primary purpose of the process is to remove Cs-137 from the aqueous waste so that it can be disposed as low level waste. It is known that this inorganic media also absorbs strontium from solution, and that strontium competes with cesium ions for absorption sites. The strontium ion is actually more strongly absorbed than the cesium ion from typical tank waste. However, strontium is typically present in low concentrations so does not normally cause a significant impact. Strontium is present as both non-radioactive isotopes and the radioactive Sr-90 isotope; with the non-radioactive isotopes being much more abundant. Although the total strontium solubility is usually much lower than cesium, some tank waste compositions can have a high enough soluble strontium concentration to decrease the cesium absorption. Relatedly, some testing at SRS suggested that another alkaline earth metal, calcium, may also absorb onto CST and may decrease cesium absorption. Barium is also an important species in treatment of tank waste, but is also usually present at low concentrations. However, after the Cs-137 is absorbed onto CST, it emits a beta particle and converts to Ba-137m, which then decays to non-radioactive Ba-137 by emission of a gamma ray. If the Ba-137m were to desorb quickly, it could impact the dose rate in down-stream equipment. In order to understand the impact of these alkaline earth metals on CST, SRNL performed testing using simulants of SRS tank waste that contain soluble barium, strontium, and calcium. Testing examined both removal of the alkaline earth metals and their impact on removal of cesium. Testing involved first developing realistic waste simulant formulations and dissolving the alkaline earth metals to high enough concentrations to potentially impact the Cs absorption. Once the formulations were developed and prepared, computer modeling was used to calculate the expected Cs absorption behavior to determine if the alkaline earth metals impact the performance. Measurements of the alkaline earth metals absorption by the media is also important for disposition of spent media because of the added radionuclide inventory from the Sr-90. These initial tests are examining the general impact and will be used to determine if further testing or measurements are needed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Defect-specific strength factors and superposition model for predicting strengthening of ion irradiated Fe18Cr alloy

Here, a high-purity binary alloy Fe18Cr was subjected to heavy-ion irradiation in order to provide improved understanding of the irradiation effect on radiation hardening associated with dislocation loop and network formation, α’ precipitation. The specimens were irradiated with 8 MeV Fe ions (~2 μm ion range) to midrange doses of 0.37 and 3.7 dpa at 300, 350 and 450 °C using dose rates of ~10 –5 –10 –3 dpa/s. Nanoindentation testing was performed to extract the bulk equivalent hardness at low depth from these ion irradiated specimens. High-quality transmission electron microscopy (TEM) images were acquired by utilizing a flash electropolishing method on the Focused Ion Beam (FIB) prepared liftouts. An accurate calculation of the strength factor was provided based on detailed TEM characterization of the irradiated microstructures. A newly refined hardening superposition method was applied to combine the strengthening components from each microstructure. The good agreement between microstructure predicted strength and measured strength further demonstrated the fidelity to use hardening model to quantify the mechanical properties of ion irradiated materials.

36 MATERIALS SCIENCE↗

Development of a MOOSE-based crystal plasticity model with irradiation defect evolution for irradiation creep in 316

Irradiation creep and irradiation swelling are two of the lifetime limiting factors for structural materials in nuclear reactors. These mechanical effects are driven by irradiation defect evolution and the interaction of those defects with dislocations in the microstructure. We present here a coupled cluster dynamics – crystal plasticity approach to model irradiation swelling and creep behavior in 316 SS. The time-dependent evolution of irradiation defects is calculated with a cluster dynamics approach and passed to the crystal plasticity model to compute the dislocation evolution. We show the impact of the irradiation defect evolution on the stress state in the material, which drives inelastic deformation through dislocation motion. The inelastic deformation in the 316 SS is dependent on the dose rate, where the inelastic deformation driven by the early-stage irradiation defect evolution determines the mechanical behavior of the 316 SS.

316 Stainless Steels↗

Dosimetric delivery validation of dynamically collimated pencil beam scanning proton therapy

Pencil beam scanning (PBS) proton therapy target dose conformity can be improved with energy layer-specific collimation. One such collimator is the dynamic collimation system (DCS), which consists of four nickel trimmer blades that intercept the scanning beam as it approaches the lateral extent of the target. While the dosimetric benefits of the DCS have been demonstrated through computational treatment planning studies, there has yet to be experimental verification of these benefits for composite multi-energy layer fields. The objective of this work is to dosimetrically characterize and experimentally validate the delivery of dynamically collimated proton therapy with the DCS equipped to a clinical PBS system. Approach. Optimized single field, uniform dose treatment plans for 3 × 3 × 3 cm 3 target volumes were generated using Monte Carlo dose calculations with depths ranging from 5 to 15 cm, trimmer-to-surface distances ranging from 5 to 18.15 cm, with and without a 4 cm thick polyethylene range shifter. Treatment plans were then delivered to a water phantom using a prototype DCS and an IBA dedicated nozzle system and measured with a Zebra multilayer ionization chamber, a MatriXX PT ionization chamber array, and Gafchromic™ EBT3 film. Main results. For measurements made within the SOBPs, average 2D gamma pass rates exceeded 98.5% for the MatriXX PT and 96.5% for film at the 2%/2 mm criterion across all measured uncollimated and collimated plans, respectively. For verification of the penumbra width reduction with collimation, film agreed with Monte Carlo with differences within 0.3 mm on average compared to 0.9 mm for the MatriXX PT. Significance. We have experimentally verified the delivery of DCS-collimated fields using a clinical PBS system and commonly available dosimeters and have also identified potential weaknesses for dosimeters subject to steep dose gradients.