Search NASA⌕ Search

SEARCH · Search NASA

Results for “Drug Design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Evaluation of the Oxygen Concentrator Prototypes: Pressure Swing Adsorption Prototype and Electrochemical Prototype

An oxygen concentrator is needed to provide enriched oxygen in support of medical contingency operations for future exploration human spaceflight programs. It would provide continuous oxygen to an ill or injured crew member in a closed cabin environment. Oxygen concentration technology is being pursued to concentrate oxygen from the ambient environment so oxygen as a consumable resource can be reduced. Because oxygen is a critical resource in manned spaceflight, using an oxygen concentrator to pull oxygen out of the ambient environment instead of using compressed oxygen can provide better optimization of resources. The overall goal of this project is to develop an oxygen concentrator module that minimizes the hardware mass, volume, and power footprint while still performing at the required clinical capabilities. Should a medical event occur that requires patient oxygenation, the release of 100 percent oxygen into a small closed cabin environment can rapidly raise oxygen levels to the vehicles fire limit. The use of an oxygen concentrator to enrich oxygen from the ambient air and concentrate it to the point where it can be used for medical purposes means no oxygen is needed from the ultra-high purity (99.5+% O2) oxygen reserve tanks. By not adding oxygen from compressed tanks to the cabin environment, oxygen levels can be kept below the vehicle fire limit thereby extending the duration of care provided to an oxygenated patient without environmental control system intervention to keep the cabin oxygen levels below the fire limits. The oxygen concentrator will be a Food and Drug Administration (FDA) clearable device. A demonstration unit for the International Space Station (ISS) is planned to verify the technology and provide oxygen capability. For the ISS, the demonstration unit should not exceed 10 kg (approximately 22 lb), which is the soft stowage mass limit for launch on resupply vehicles for the ISS. The unit's size should allow for transport within the spacecraft to an ill crewmember. The user interface needs to be designed for ease of use by the local care provider and with consideration to the limited amount of training available to the astronaut corps for medical equipment and procedures.

Gilkey, Kelly M.↗

NASA Tech Briefs, March 2012

The topics include: 1) Spectral Profiler Probe for In Situ Snow Grain Size and Composition Stratigraphy; 2) Portable Fourier Transform Spectroscopy for Analysis of Surface Contamination and Quality Control; 3) In Situ Geochemical Analysis and Age Dating of Rocks Using Laser Ablation-Miniature Mass Spectrometer; 4) Physics Mining of Multi-Source Data Sets; 5) Photogrammetry Tool for Forensic Analysis; 6) Connect Global Positioning System RF Module; 7) Simple Cell Balance Circuit; 8) Miniature EVA Software Defined Radio; 9) Remotely Accessible Testbed for Software Defined Radio Development; 10) System-of-Systems Technology-Portfolio-Analysis Tool; 11) VESGEN Software for Mapping and Quantification of Vascular Regulators; 12) Constructing a Database From Multiple 2D Images for Camera Pose Estimation and Robot Localization; 13) Adaption of G-TAG Software for Validating Touch and Go Asteroid Sample Return Design Methodology; 14) 3D Visualization for Phoenix Mars Lander Science Operations; 15) RxGen General Optical Model Prescription Generator; 16) Carbon Nanotube Bonding Strength Enhancement Using Metal Wicking Process; 17) Multi-Layer Far-Infrared Component Technology; 18) Germanium Lift-Off Masks for Thin Metal Film Patterning; 19) Sealing Materials for Use in Vacuum at High Temperatures; 20) Radiation Shielding System Using a Composite of Carbon Nanotubes Loaded With Electropolymers; 21) Nano Sponges for Drug Delivery and Medicinal Applications; 22) Molecular Technique to Understand Deep Microbial Diversity; 23) Methods and Compositions Based on Culturing Microorganisms in Low Sedimental Fluid Shear Conditions; 24) Secure Peer-to-Peer Networks for Scientific Information Sharing; 25) Multiplexer/Demultiplexer Loading Tool (MDMLT); 26) High-Rate Data-Capture for an Airborne Lidar System; 27) Wavefront Sensing Analysis of Grazing Incidence Optical Systems; 28) Foam-on-Tile Damage Model; 29) Instrument Package Manipulation Through the Generation and Use of an Attenuated-Fluent Gas Fold; 30) Multicolor Detectors for Ultrasensitive Long-Wave Imaging Cameras; 31) Lunar Reconnaissance Orbiter (LRO) Command and Data Handling Flight Electronics Subsystem; and 32) Electro-Optic Segment-Segment Sensors for Radio and Optical Telescopes.

Source record↗

Microfluidic Mixing Technology for a Universal Health Sensor

A highly efficient means of microfluidic mixing has been created for use with the rHEALTH sensor an elliptical mixer and passive curvilinear mixing patterns. The rHEALTH sensor provides rapid, handheld, complete blood count, cell differential counts, electrolyte measurements, and other lab tests based on a reusable, flow-based microfluidic platform. These geometries allow for cleaning in a reusable manner, and also allow for complete mixing of fluid streams. The microfluidic mixing is performed by flowing two streams of fluid into an elliptical or curvilinear design that allows the combination of the flows into one channel. The mixing is accomplished by either chaotic advection around micro - fluidic loops. All components of the microfluidic chip are flow-through, meaning that cleaning solution can be introduced into the chip to flush out cells, plasma proteins, and dye. Tests were performed on multiple chip geometries to show that cleaning is efficient in any flowthrough design. The conclusion from these experiments is that the chip can indeed be flushed out with microliter volumes of solution and biological samples are cleaned readily from the chip with minimal effort. The technology can be applied in real-time health monitoring at patient s bedside or in a doctor s office, and real-time clinical intervention in acute situations. It also can be used for daily measurement of hematocrit for patients on anticoagulant drugs, or to detect acute myocardial damage outside a hospital.

Chan, Eugene Y.↗

Applications of aerospace technology in biology and medicine

A bipolar, donor-recipient model of medical technology transfer is introduced to provide a basis for the team's methodology. That methodology is designed (1) to identify medical problems and NASA technology that in combination constitute opportunities for successful medical products, (2) to obtain the early participation of industry in the transfer proces, and (3) to obtain acceptance by the medical community of new medical products based on NASA technology. Two commercial technology transfers and five institutional technology transfers were completed in 1977. A new, commercially available teaching manikin system uses NASA-developed concepts and techniques for effective visual presentation of information and data. Drugs shipped by the National Cancer Institute to locations throughout the world are maintained at low temperatures in shipping containers that incorporate recommendations made by NASA.

Beall, H. C.↗

Health Maintenance System (HMS) Hardware Research, Design, and Collaboration

The Space Life Sciences division (SLSD) concentrates on optimizing a crew member's health. Developments are translated into innovative engineering solutions, research growth, and community awareness. This internship incorporates all those areas by targeting various projects. The main project focuses on integrating clinical and biomedical engineering principles to design, develop, and test new medical kits scheduled for launch in the Spring of 2011. Additionally, items will be tagged with Radio Frequency Interference Devices (RFID) to keep track of the inventory. The tags will then be tested to optimize Radio Frequency feed and feed placement. Research growth will occur with ground based experiments designed to measure calcium encrusted deposits in the International Space Station (ISS). The tests will assess the urine calcium levels with Portable Clinical Blood Analyzer (PCBA) technology. If effective then a model for urine calcium will be developed and expanded to microgravity environments. To support collaboration amongst the subdivisions of SLSD the architecture of the Crew Healthcare Systems (CHeCS) SharePoint site has been redesigned for maximum efficiency. Community collaboration has also been established with the University of Southern California, Dept. of Aeronautical Engineering and the Food and Drug Administration (FDA). Hardware disbursements will transpire within these communities to support planetary surface exploration and to serve as an educational tool demonstrating how ground based medicine influenced the technological development of space hardware.

Gonzalez, Stefanie M.↗

NASA's plans for life sciences research facilities on a Space Station

A Life Sciences Research Facility on a Space Station will contribute to the health and well-being of humans in space, as well as address many fundamental questions in gravitational and developmental biology. Scientific interests include bone and muscle attrition, fluid and electrolyte shifts, cardiovascular deconditioning, metabolism, neurophysiology, reproduction, behavior, drugs and immunology, radiation biology, and closed life-support system development. The life sciences module will include a laboratory and a vivarium. Trade-offs currently being evaluated include (1) the need for and size of a 1-g control centrifuge; (2) specimen quantities and species for research; (3) degree of on-board analysis versus sample return and ground analysis; (4) type and extent of equipment automation; (5) facility return versus on-orbit refurbishment; (6) facility modularity, isolation, and system independence; and (7) selection of experiments, design, autonomy, sharing, compatibility, and integration.

Arno, R.↗

Code Blue on Orbit: Treating Cardiac Arrest on the ISS

As a result of the Columbia tragedy on February 1,2003, the International Space Station (ISS) crew size has been temporarily reduced from three to two. This change forces adaptations in many operational procedures used by the crew, including medical protocols which were designed for scenarios involving one casualty and two caregivers. The Office of Space Medicine directed that the procedure for the resuscitation of a crewmember in cardiac arrest be rewritten for use by a single care provider. Methods: Adaptation of this procedure made use of current American Heart Association Advanced Cardiac Life Support (ACLS) procedures and reflects necessary compromises between the realities of the operational environment and prompt provision of medical care. Results: Numerous changes were incorporated due to the diminution in available personnel, including substitution of endotracheal rather than intravenous delivery of drugs, more rapid defibrillation, addition of a precordial thump, removal of transcutaneous pacing, streamlining of procedural steps, and clarification of termination criteria. Discussion: The on-orbit care available to the ISS crewmembers is constrained by numerous factors, including crew medical training, minimal medical assets, limited air/ground communication , and a single caregiver for the foreseeable future. All of these combine to make a successful resuscitation unlikely, however, this procedure must ultimately deal with not only the patient's welfare, but also that of the caregiver, the mission, and the program.

Bacal, Kira↗

Causes of chronic orthostatic hypotension

OBJECTIVE: To determine the frequency of various causes of orthostatic hypotension. DESIGN: Survey. SETTING: Tertiary referral center. PATIENTS: One hundred patients with moderate to severe orthostatic hypotension. RESULTS: Twenty-seven percent of the patients had primary autonomic failure, 35% had secondary autonomic failure, and 38% had hypotension without evidence of generalized autonomic degeneration. CONCLUSIONS: In a tertiary referral center, only a minority of patients with severe orthostatic hypotension will have Shy-Drager syndrome or Bradbury-Eggleston syndrome as their primary disease. Occasional patients who initially appear to have Bradbury-Eggleston syndrome ultimately prove to have Shy-Drager syndrome or paraneoplastic autonomic failure. Antidepressant drugs, even in low doses, remain a major overlooked cause of orthostatic hypotension.

NASA Discipline Regulatory Physiology↗

Implantable Wireless MEMS Sensors for Medical Uses

Sensors designed and fabricated according to the principles of microelectromechanical systems (MEMS) are being developed for several medical applications in outer space and on Earth. The designs of these sensors are based on a core design family of pressure sensors, small enough to fit into the eye of a needle, that are fabricated by a "dissolved wafer" process. The sensors are expected to be implantable, batteryless, and wireless. They would be both powered and interrogated by hand-held radio transceivers from distances up to about 6 in. (about 15 cm). One type of sensor would be used to measure blood pressure, particularly for congestive heart failure. Another type would be used to monitor fluids in patients who have hydrocephalus (high brain pressure). Still other types would be used to detect errors in delivery of drugs and to help patients having congestive heart failure.

Chimbayo, Alexander↗

Colloidal Gelation-2 and Colloidal Disorder-Order Transition-2 Investigations Conducted on STS-95

The Colloidal Gelation-2 (CGEL 2) and Colloidal Disorder-Order Transition-2 (CDOT 2) investigations flew on Space Shuttle Discovery mission STS-95 (also known as the John Glenn Mission). These investigations were part of a series of colloid experiments designed to help scientists answer fundamental science questions and reduce the trial and error involved in developing new and better materials. Industries dealing with semiconductors, electro-optics, ceramics, and composites are just a few that may benefit from this knowledge. The goal of the CGEL 2 investigation was to study the fundamental properties of colloids to help scientists better understand their nature and make them more useful for technology. Colloids consist of very small (submicron) particles suspended in a fluid. They play a critical role in the technology of this country, finding uses in materials ranging from paints and coatings to drugs, cosmetics, food, and drink. Although these products are routinely produced and used, there are still many aspects of their behavior about which scientists know little. Understanding their structures may allow scientists to manipulate the physical properties of colloids (a process called "colloidal engineering") to produce new materials and products. Colloid research may even improve the processing of known products to enhance their desirable properties.

Hoffmann, Monica T.↗

A Manual Control Test for the Detection and Deterrence of Impaired Drivers

A brief manual control test and a decision strategy were developed, laboratory tested, and field validated which provide a means for detecting human operator impairment from alcohol or other drugs. The test requires the operator to stabilize progressively unstable controlled element dynamics. Control theory and experimental data verify that the human operator's control ability on this task is constrained by basic cybernetic characteristics, and that task performance is reliably affected by impairment effects on these characteristics. Assessment of human operator control ability is determined by a statistically based decision strategy. The operator is allowed several chances to exceed a preset pass criterion. Procedures are described for setting the pass criterion based on individual ability and a desired unimpaired failure rate. These procedures were field tested with apparatus installed in automobiles that were designed to discourage drunk drivers from operating their vehicles. This test program demonstrated that the control task and detection strategy could be applied in a practical setting to screen human operators for impairment in their basic cybernetic skills.

Stein, A. C.↗

CO2 capture by means of an enzyme-based reactor

We report a means for efficient and selective extraction of carbon dioxide (CO(2)) at low to medium concentration from mixed gas streams. CO(2) capture was accomplished by use of a novel enzyme-based, facilitated transport contained liquid membrane (EBCLM) reactor. The parametric studies we report explore both structural and operational parameters of this design. The structural parameters include carbonic anhydrase (CA) concentration, buffer concentration and pH, and liquid membrane thickness. The operational parameters are temperature, humidity of the inlet gas stream, and CO(2) concentration in the feed stream. The data show that this system effectively captures CO(2) over the range 400 ppm to at least 100,000 ppm, at or around ambient temperature and pressure. In a single pass across this homogeneous catalyst design, given a feed of 0.1% CO(2), the selectivity of CO(2) versus N(2) is 1,090 : 1 and CO(2) versus O(2) is 790 :1. CO(2) permeance is 4.71 x 10(-8) molm(-2) Pa(-1) sec(-1). The CLM design results in a system that is very stable even in the presence of dry feed and sweep gases.

NASA Discipline Life Support Systems↗

Insulin secretion and sensitivity in space flight: diabetogenic effects

Nearly three decades of space flight research have suggested that there are subclinical diabetogenic changes that occur in microgravity. Alterations in insulin secretion, insulin sensitivity, glucose tolerance, and metabolism of protein and amino acids support the hypothesis that insulin plays an essential role in the maintenance of muscle mass in extended-duration space flight. Experiments in flight and after flight and ground-based bedrest studies have associated microgravity and its experimental paradigms with manifestations similar to those of diabetes, physical inactivity, and aging. We propose that these manifestations are characterized best by an etiology that falls into the clinical category of "other" causes of diabetes, including, but not restricted to, genetic beta-cell defects, insulin action defects, diseases of the endocrine pancreas, endocrinopathies, drug or chemically induced diabetes, infections, immune-mediated metabolic alteration, and a host of genetic related diseases. We present data showing alterations in tumor necrosis factor-alpha production, insulin secretion, and amino acid metabolism in pancreatic islets of Langerhans cultured in a ground-based cell culture bioreactor that mimics some of the effects of microgravity. Taken together, space flight research, ground-based studies, and bioreactor studies of pancreatic islets of Langerhans support the hypothesis that the pancreas is unable to overcome peripheral insulin resistance and amino acid dysregulation during space flight. We propose that measures of insulin secretion and insulin action will be necessary to design effective countermeasures against muscle loss, and we advance the "disposition index" as an essential model to be used in the clinical management of space flight-induced muscle loss.

Review↗

Biofabrication in Space - A Perspective

Human exploration of Mars is one of the primary goals of NASA. A three-year human exploration mission to Mars is a viable design reference mission (Design Reference Mission). If we are sending a four member crew, comprehensive understanding of the health conditions of the crew is important. Based on the biomedical results of long-duration crew members at ISS, and during gravitational transitions, a few maladaptation have been observed. Discovering the root-cause of these aberrations and finding suitable mitigations at the molecular and cellular levels are of importance for a successful mission. Developing and executing the technologies to carry out tissue generation in space as well as the development of an analog hardware for tissue generation under terrestrial conditions will be discussed. These tissues were typically used to develop disease models and drug toxicology studies for several weeks and many other applications. The significant progress made during the last two decades have unfolded developments in organ generation, stem cell generation in space. When you remove the gravitational force during these cellular building processes while in space, other forces like surface tension, intermolecular forces, Coriolis force, loss of convection, reduced shear force, dominate the environment leading to behavior that we may not observe under terrestrial conditions. Based on these discoveries, the fundamental mechanisms could be better understood and new insights into bioprocesses could be developed for an exciting future.

Antony Jeevarajan↗

Recovery from vestibular ototoxicity

OBJECTIVE: Determine whether subjects with documented vestibular ototoxicity recover vestibular function and, if so, investigate the recovery dynamics. STUDY DESIGN: Prospective and retrospective reviews and repeated measures. SETTING: Clinical research and technology center. SUBJECTS: Twenty-eight subjects who received vestibulotoxic medications were followed for at least 12 months after initial treatment. CONTROLS: Our subject sample was compared with a published database of normal individuals. INTERVENTIONS: All 28 subjects received systemically administered medications known to be ototoxic. The subjects' treating physicians controlled medication, dosage, and administration schedules. MAIN OUTCOME MEASURES: Tests of horizontal canal vestibulo-ocular function were performed. Subjects' auditory and vestibular symptoms were recorded. RESULTS: Eleven subjects (39%) showed changes in horizontal canal vestibulo-ocular gain constant (GC) and/or time constant (TC) consistent with vestibular ototoxicity. When tested 1 year after ototoxic drug administration, eight of the nine subjects who experienced ototoxic decrease in GC showed a recovery of GC to normal limits. Only one of the eight subjects who experienced ototoxic decrease in TC showed recovery of TC to within normal limits. Ototoxicity onset and recovery were independent of baseline vestibular function, and ototoxicity onset did not correlate with cumulative dose of ototoxic medication. There was no relationship between subjective symptoms and ototoxicity onset. CONCLUSIONS: Recovery of GC after vestibular ototoxicity is more commonly observed than recovery of TC. Because ototoxic changes developed and continued in an unpredictable time and manner in relation to ototoxic drug administration, we propose that once ototoxic changes in vestibulo-ocular reflex are detected, ototoxic medications should be discontinued as soon as possible.

NASA Discipline Neuroscience↗

Space motion sickness

Research on the etiology, prediction, treatment and prevention of space motion sickness, designed to minimize the impact of this syndrome which was experienced frequently and with severity by individuals on the Skylab missions, on Space Shuttle crews is reviewed. Theories of the cause of space motion sickness currently under investigation by NASA include sensory conflict, which argues that motion sickness symptoms result from a mismatch between the total pattern of information from the spatial senses and that stored from previous experiences, and fluid shift, based upon the redistribution of bodily fluids that occurs upon continued exposure to weightlessness. Attempts are underway to correlate space motion sickness susceptibility to different provocative environments, vestibular and nonvestibular responses, and the rate of acquisition and length of retention of sensory adaptation. Space motion sickness countermeasures under investigation include various drug combinations, of which the equal combination of promethazine and ephedrine has been found to be as effective as the scopolomine and dexedrine combination, and vestibular adaptation and biofeedback training and autogenic therapy.

Homick, J. L.↗

Free-Energy Calculations. A Mathematical Perspective

Ion channels are pore-forming assemblies of transmembrane proteins that mediate and regulate ion transport through cell walls. They are ubiquitous to all life forms. In humans and other higher organisms they play the central role in conducting nerve impulses. They are also essential to cardiac processes, muscle contraction and epithelial transport. Ion channels from lower organisms can act as toxins or antimicrobial agents, and in a number of cases are involved in infectious diseases. Because of their important and diverse biological functions they are frequent targets of drug action. Also, simple natural or synthetic channels find numerous applications in biotechnology. For these reasons, studies of ion channels are at the forefront of biophysics, structural biology and cellular biology. In the last decade, the increased availability of X-ray structures has greatly advanced our understanding of ion channels. However, their mechanism of action remains elusive. This is because, in order to assist controlled ion transport, ion channels are dynamic by nature, but X-ray crystallography captures the channel in a single, sometimes non-native state. To explain how ion channels work, X-ray structures have to be supplemented with dynamic information. In principle, molecular dynamics (MD) simulations can aid in providing this information, as this is precisely what MD has been designed to do. However, MD simulations suffer from their own problems, such as inability to access sufficiently long time scales or limited accuracy of force fields. To assess the reliability of MD simulations it is only natural to turn to the main function of channels - conducting ions - and compare calculated ionic conductance with electrophysiological data, mainly single channel recordings, obtained under similar conditions. If this comparison is satisfactory it would greatly increase our confidence that both the structures and our computational methodologies are sufficiently accurate. Channel conductance, defined as the ratio of ionic current through the channel to applied voltage, can be calculated in MD simulations by way of applying an external electric field to the system and counting the number of ions that traverse the channel per unit time. If the current is small, a voltage significantly higher than the experimental one needs to be applied to collect sufficient statistics of ion crossing events. Then, the calculated conductance has to be extrapolated to the experimental voltage using procedures of unknown accuracy. Instead, we propose an alternative approach that applies if ion transport through channels can be described with sufficient accuracy by the one-dimensional diffusion equation in the potential given by the free energy profile and applied voltage. Then, it is possible to test the assumptions of the equation, recover the full voltage/current dependence, determine the reliability of the calculated conductance and reconstruct the underlying (equilibrium) free energy profile, all from MD simulations at a single voltage. We will present the underlying theory, model calculations that test this theory and simulations on ion conductance through a channel that has been extensively studied experimentally. To our knowledge this is the first case in which the complete, experimentally measured dependence of the current on applied voltage has been reconstructed from MD simulations.

free energy↗

Pharmacokinetics of Intranasal Scopolamine Gel Formation During Antiorthostatic Bedrest - A Microgravity Analog

Space Motion sickness (SMS) is an age old problem for astronauts on both short and long duration space flights. Scopolamine (SCOP) is the most frequently used drug for the treatment of motion sickness (MS) which is currently available in transdermal patch and tablet dosage forms. These formulations of SCOP are ineffective for the treatment of SMS. Intranasal dosage forms are noninvasive with rapid absorption and enhanced bioavailability thus allowing precise and reduced dosing options in addition to offering rescue and treatment options. As such, an intranasal gel dosage formulation of scopolamine (INSCOP) was developed and Pharmacokinetics (PK) and bioavailability were determined under IND guidelines. The present clinical trial compares PK and bioavailability of INSCOP in 12 normal, healthy subjects (6 male/ 6 female) during ambulation (AMB) and antiorthostatic bedrest (ABR) used as a ground-based microgravity analog. Subjects received 0.2 and 0.4 mg doses of INSCOP during AMB and ABR in a four-way crossover design. Results indicated no difference between AMB and ABR in PK parameters after 0.2 mg dose. Clearance (Cls) decreased with a concomitant increase in maximum concentration and area under concentration versus time curve (AUC) during ABR after the 0.4 mg dose. This difference in AUC and Cls at the higher but not the lower dose during ABR may suggest that ABR may affect metabolism and/or clearance at higher doses of INSCOP. These results indicate that dosing adjustment may be required for treatment of SMS with INSCOP in space.

Lakshmi, Putcha↗