Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dual exposure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Precision Structure Engineering of High-Entropy Oxides under Ambient Conditions

High-entropy oxides (HEOs) have unveiled a unique frontier in the realm of heterogeneous catalysis, taking advantage of the entropic effect and increased complexities to deliver ultrahigh stability and large tuning capability. However, current HEO synthesis mainly relies on high-temperature annealing approaches affording HEOs possessing no or low surface area, inferior active site exposure efficiency, and low controllability over the structure tuning. The grand challenge lies in producing high-quality HEO catalysts with high active site utilization efficiency, which relies on precision structure engineering, preferably under mild conditions. In this work, an in situ lattice engineering approach was developed to afford a supported HEO catalyst under ambient conditions. The HEO compositions (CuCoFeNiMnO x ) were uniformly integrated into the lattice of CeO 2 driven by cavitation-induced nucleation being generated via ultrasonication. The as-afforded catalysts were featured by high surface area, atomically dispersed HEO compositions, active redox properties, abundant oxygen vacancies (O V ), antiagglomeration, and high phase stability under harsh conditions. Compared with the ex situ introduction of HEO on the surface, the in situ method provides dual benefits to maintain the dispersity of HEO via entropic and lattice confinement effects. Engineering the complex HEO within the lattice of fluorite-structured CeO 2 also yields abundant defects (e.g., O V ) and active metal sites with strong reducing properties (e.g., Ce 3+ and Cu + ), which greatly improves the activity of the lattice oxygen and tunability of the adsorption behavior of the guest molecules, especially in the presence of impurities (e.g., water and propane). The catalytic performance of the supported HEO catalyst in oxidative procedures surpasses the pure dense phase HEO as well as the ex situ-generated catalysts. Further, the synthesis approach being developed in this work, together with the fundamental understanding in structure evolution and reaction mechanism, showcases a facile pathway under ambient conditions to generate stable catalysts capable of maintaining structural robustness in high-temperature conditions while delivering enhanced catalytic performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Three-Dimensional, Transgenic Cell Models to Quantify Space Genotoxic Effects

The space environment contains radiation and chemical agents known to be mutagenic and carcinogenic to humans. Additionally, microgravity is a complicating factor that may modify or synergize induced genotoxic effects. Most in vitro models fail to use human cells (making risk extrapolation to humans more difficult), overlook the dynamic effect of tissue intercellular interactions on genotoxic damage, and lack the sensitivity required to measure low-dose effects. Currently a need exists for a model test system that simulates cellular interactions present in tissue, and can be used to quantify genotoxic damage induced by low levels of radiation and chemicals, and extrapolate assessed risk to humans. A state-of-the-art, three-dimensional, multicellular tissue equivalent cell culture model will be presented. It consists of mammalian cells genetically engineered to contain multiple copies of defined target genes for genotoxic assessment,. NASA-designed bioreactors were used to coculture mammalian cells into spheroids, The cells used were human mammary epithelial cells (H184135) and Stratagene's (Austin, Texas) Big Blue(TM) Rat 2 lambda fibroblasts. The fibroblasts were genetically engineered to contain -a high-density target gene for mutagenesis (60 copies of lacl/LacZ per cell). Tissue equivalent spheroids were routinely produced by inoculation of 2 to 7 X 10(exp 5) fibroblasts with Cytodex 3 beads (150 micrometers in diameter). at a 20:1 cell:bead ratio, into 50-ml HARV bioreactors (Synthecon, Inc.). Fibroblasts were cultured for 5 days, an equivalent number of epithelial cells added, and the fibroblast/epithelial cell coculture continued for 21 days. Three-dimensional spheroids with diameters ranging from 400 to 600 micrometers were obtained. Histological and immunohistochemical Characterization revealed i) both cell types present in the spheroids, with fibroblasts located primarily in the center, surrounded by epithelial cells; ii) synthesis of extracellular matrix; and iii,, mitotic cells located throughout the spheroids. Spheroidal integrity and cell viability were retained for the 30-day test period after removal of spheroids from the bioreactor. Potential utility of this three-dimensional, transgenic model for genotoxicity was initially assessed by exposure of spheroids to 0-2 Gy neon at dose rates of 0.3 to 1.5 Gy/min (National Institute of Radiological Sciences, Chiba, Japan). Quantification of mutation at the lacl gene revealed a linear dose response for mutation induction. Limited sequencing analysis of mutant clones revealed higher frequencies of deletions and multiple base sequence changes with increasing dose. These results suggest that our three-dimensional, transgenic model is applicable to a wide variety of studies involving the quantification, identification, and characterization of genotoxicity incurred in space and on Earth. This model uniquely allows investigation of the interaction of relevant factors, namely cell-to-cell interactions and the mechanistic interaction of microgravity with radiation insults and DNA repair. Using this three-dimensional model will allow us to obtain dual genotoxic information (i.e., mutation rate plus chromosome aberration data) from the same system so that one endpoint can be used to reference the other, thereby increasing the fidelity of the data set. Moreover, the tissue-equivalent nature of the three-dimensional model provides high confidence for relevance of risk assessment, i.e., the establishment of quality factors directly applicable to the microgravity environment.

Gonda, S. R.↗

Plant genotype and rhizobia strain combinations strongly influence the transcriptome under heavy metal stress conditions in Medicago truncatula

Heavy metals such as cadmium (Cd) and mercury (Hg) pose significant threats to plant health and food safety as they are absorbed from the environment. Legumes are generally considered sensitive to heavy metals but possess standing genetic variation for accumulation and tolerance to toxic ions. We conducted a transcriptomic analysis on hydroponically and soil grown Medicago truncatula plants to investigate gene expression responses to Cd and Hg exposure in roots, leaves, and nodules. By using plant genotypes with varying metal tolerance or accumulation levels, we observed distinct clustering of gene ontologies, indicating tissue-specific, genotype-specific, and metal-specific gene expression patterns. Considering the symbiotic relationship between legumes and nitrogen-fixing bacteria, we further examined plant phenotypes and transcriptomes of plant genotypes with contrasting Hg accumulation levels and inoculated them with high or low Hg-tolerant Sinorhizobium medicae strains that have presence-absence variation for a mercury reductase (Mer) operon. Host plants inoculated with the Hg-tolerant rhizobia strain possessing a Mer operon exhibited less reduction in nodule number and plant biomass. A smaller reduction in iron (Fe) distribution in nodules after Hg stress was measured using X-ray Fluorescence (XRF) imaging. Dual transcriptome (host plant and bacteria) analysis of nodules revealed a remarkable decrease in the number of differentially expressed genes (DEGs) and clustering of gene ontologies in plants inoculated with the Hg-tolerant rhizobia strain, including symbiosis related genes. This finding suggests that the Hg-tolerant rhizobia strain has the potential to mitigate Hg stress in host plants. Furthermore, we observed genotype by-genotype interactions between the high Hg accumulating plant genotype and the Hg-tolerant rhizobia strain. These findings provide insights into enhancing plant resilience in contaminated environments through optimizing legume-rhizobia interactions for heavy metal tolerance.

59 BASIC BIOLOGICAL SCIENCES↗

Control of Risks Through the Use of Procedures: A Method for Evaluating the Change in Risk

This paper considers how procedures can be used to control risks faced by an organization and proposes a means of recognizing if a particular procedure reduces risk or contributes to the organization's exposure. The proposed method was developed out of the review of work documents and the governing procedures performed in the wake of the Columbia accident by NASA and the Space Shuttle prime contractor, United Space Alliance, LLC. A technique was needed to understand the rules, or procedural controls, in place at the time in the context of how important the role of each rule was. The proposed method assesses procedural risks, the residual risk associated with a hazard after a procedure's influence is accounted for, by considering each clause of a procedure as a unique procedural control that may be beneficial or harmful. For procedural risks with consequences severe enough to threaten the survival of the organization, the method measures the characteristics of each risk on a scale that is an alternative to the traditional consequence/likelihood couple. The dual benefits of the substitute scales are that they eliminate both the need to quantify a relationship between different consequence types and the need for the extensive history a probabilistic risk assessment would require. Control Value is used as an analog for the consequence, where the value of a rule is based on how well the control reduces the severity of the consequence when operating successfully. This value is composed of two parts: the inevitability of the consequence in the absence of the control, and the opportunity to intervene before the consequence is realized. High value controls will be ones where there is minimal need for intervention but maximum opportunity to actively prevent the outcome. Failure Likelihood is used as the substitute for the conventional likelihood of the outcome. For procedural controls, a failure is considered to be any non-malicious violation of the rule, whether intended or not. The model used for describing the Failure Likelihood considers how well a task was established by evaluating that task on five components. The components selected to define a well established task are: that it be defined, assigned to someone capable, that they be trained appropriately, that the actions be organized to enable proper completion and that some form of independent monitoring be performed. Validation of the method was based on the information provided by a group of experts in Space Shuttle ground processing when they were presented with 5 scenarios that identified a clause from a procedure. For each scenario, they recorded their perception of how important the associated rule was and how likely it was to fail. They then rated the components of Control Value and Failure Likelihood for all the scenarios. The order in which each reviewer ranked the scenarios Control Value and Failure Likelihood was compared to the order in which they ranked the scenarios for each of the associated components; inevitability and opportunity for Control Value and definition, assignment, training, organization and monitoring for Failure Likelihood. This order comparison showed how the components contributed to a relative relationship to the substitute risk element. With the relationship established for Space Shuttle ground processing, this method can be used to gauge if the introduction or removal of a particular rule will increase or decrease the .risk associated with the hazard it is intended to control.

Praino, Gregory T.↗

A volatile organic analyzer for Space Station: Description and evaluation of a gas chromatography/ ion mobility

A Volatile Organic Analyzer (VOA) is being developed as an essential component of the Space Station's Environmental Health System (EHS) air quality monitoring strategy to provide warning to the crew and ground personnel if volatile organic compounds exceed established exposure limits. The short duration of most Shuttle flights and the relative simplicity of the contaminant removal mechanism have lessened the concern about crew exposure to air contaminants on the Shuttle. However, the longer missions associated with the Space Station, the complex air revitalization system and the proposed number of experiments have led to a desire for real-time monitoring of the contaminants in the Space Station atmosphere. Achieving the performance requirements established for the VOA within the Space Station resource (e.g., power, weight) allocations led to a novel approach that joined a gas chromatograph (GC) to an ion mobility spectrometer (IMS). The authors of this paper will discuss the rational for selecting the GC/IMS technology as opposed to the more established gas chromatography/mass spectrometry (GC/MS) for the foundation of the VOA. The data presented from preliminary evaluations will demonstrate the versatile capability of the GC/IMS to analyze the major contaminants expected in the Space Station atmosphere. The favorable GC/IMS characteristics illustrated in this paper included excellent sensitivity, dual-mode operation for selective detection, and mobility drift times to distinguish co-eluting GC peaks. Preliminary studies have shown that the GC/IMS technology can meet surpass the performance requirements of the Space Station VOA.

Limero, Thomas F.↗

Expanding the Description of Spaceflight Effects beyond Bone Mineral Density [BMD]: Trabecular Bone Score [TBS] in ISS Astronauts

Dual-energy x-ray absorptiometry [DXA] is the widely-applied bone densitometry method used to diagnose osteoporosis in a terrestrial population known to be at risk for age-related bone loss. This medical test, which measures areal bone mineral density [aBMD] of clinically-relevant skeletal sites (e.g., hip and spine), helps the clinician to identify which persons, among postmenopausal women and men older than 50 years, are at high risk for low trauma or fragility fractures and might require an intervention. The most recognized osteoporotic fragility fracture is the vertebral compression fracture which can lead to kyphosis or hunched backs typically seen in the elderly. DXA measurement of BMD however is recognized to be insufficient as a sole index for assessing fracture risk. DXA's limitation may be related to its inability to monitor changes in structural parameters, such as trabecular vs. cortical bone volumes, bone geometry or trabecular microarchitecture. Hence, in order to understand risks to human health and performance due to space exposure, NASA needs to expand its measurements of bone to include other contributors to skeletal integrity. To this aim, the Bone and Mineral Lab conducted a pilot study for a novel measurement of bone microarchitecture that can be obtained by retrospective analysis of DXA scans. Trabecular Bone Score (TBS) assesses changes to trabecular microarchitecture by measuring the grey color "texture" information extracted from DXA images of the lumbar spine. An analysis of TBS in 51 ISS astronauts was conducted to assess if TBS could detect 1) an effect of spaceflight and 2) a response to countermeasures independent of DXA BMD. In addition, changes in trunk body lean tissue mass and in trunk body fat tissue mass were also evaluated to explore an association between body composition, as impacted by ARED exercise, and bone microarchitecture. The pilot analysis of 51 astronaut scans of the lumbar spine suggests that, following an ISS mission, DXA BMD and TBS are detecting different effects of ARED exercise and of ARED + Bisphosphonate on the lumbar spine of astronauts. There is emerging evidence associating reduced TBS with terrestrial metabolic bone disorders where a TBS <1.200 is associated with "degraded" while > 1.350 is associated with "normal." However, it is not possible to conclude how the spaceflight-induced changes in TBS increase risk for vertebral fractures in the astronaut or if changes in body composition of the trunk region could be an indirect method of assessing exercise effect on bone microarchitecture. More importantly, this pilot analysis demonstrates a new, minimal risk approach for monitoring changes to vertebral bone microarchitecture. This method could help assess the combined skeletal effects of spaceflight with the effects of aging in the astronaut after return to Earth.

Sibonga, J. D.↗

DarkSide-20k sensitivity to light dark matter particles

The dual-phase liquid argon time projection chamber is presently one of the leading technologies to search for dark matter particles with masses below 10 GeV c$^{−2}$. This was demonstrated by the DarkSide-50 experiment with approximately 50 kg of low-radioactivity liquid argon as target material. The next generation experiment DarkSide-20k, currently under construction, will use 1,000 times more argon and is expected to start operation in 2027. Based on the DarkSide-50 experience, here we assess the DarkSide-20k sensitivity to models predicting light dark matter particles, including Weakly Interacting Massive Particles (WIMPs) and sub-GeV c$^{−2}$ particles interacting with electrons in argon atoms. With one year of data, a sensitivity improvement to dark matter interaction cross-sections by at least one order of magnitude with respect to DarkSide-50 is expected for all these models. A sensitivity to WIMP–nucleon interaction cross-sections below 1 × 10$^{−42}$ cm$^{2}$ is achievable for WIMP masses above 800 MeV c$^{−2}$. With 10 years exposure, the neutrino fog can be reached for WIMP masses around 5 GeV c$^{−2}$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Mars Gravity Simulation Project

Human beings who make abrupt transitions between one gravitational environment and another undergo severe disruptions of their visual perception and visual- motor coordination, frequently accompanied by "space sickness." Clearly, such immediate effects of exposure to a novel gravitational condition have significant implications for human performance. For example, when astronauts first arrive in Earth orbit their attempts to move about in the spacecraft and to perform their duties are uncoordinated, inaccurate, and inefficient. Other inter-gravitational transitions for which these difficulties can be expected include going from the 0 g of the spacecraft to the. 16 g of the Moon, from 0 g to the .38 g of Mars, and from 0 g back to the 1.0 g of Earth. However, after astronauts have actively interacted with their new gravitational environment for several days, these problems tend to disappear, evidence that some sort of adaptive process has taken place. It would be advantageous, therefore, if there were some way to minimize or perhaps even to eliminate this potentially hazardous adaptive transition period by allowing astronauts to adapt to the altered gravitational conditions before actually entering them. Simultaneous adaptations to both the altered and the normal gravitational environment as a result of repeatedly adapting to one and readapting to the other, a phenomenon known as dual adaptation. The objective of the Mars Gravity Simulator (MGS) Project is to construct a simulation of the visual and bodily effects of altered gravity. This perceptual-motor simulation is created through the use of: 1) differential body pressure to produce simulated hypo-gravity and 2) treadmill-controlled virtual reality to create a corresponding visual effect. It is expected that this combination will produce sensory motor perturbations in the subjects. Both the immediate and adaptive behavioral (postural and ambulatory) responses to these sensory perturbations will be assessed.

Korienek, Gene↗

Trabecular Bone Mechanical Properties and Fractal Dimension

Countermeasures for reducing bone loss and muscle atrophy due to extended exposure to the microgravity environment of space are continuing to be developed and improved. An important component of this effort is finite element modeling of the lower extremity and spinal column. These models will permit analysis and evaluation specific to each individual and thereby provide more efficient and effective exercise protocols. Inflight countermeasures and post-flight rehabilitation can then be customized and targeted on a case-by-case basis. Recent Summer Faculty Fellowship participants have focused upon finite element mesh generation, muscle force estimation, and fractal calculations of trabecular bone microstructure. Methods have been developed for generating the three-dimensional geometry of the femur from serial section magnetic resonance images (MRI). The use of MRI as an imaging modality avoids excessive exposure to radiation associated with X-ray based methods. These images can also detect trabecular bone microstructure and architecture. The goal of the current research is to determine the degree to which the fractal dimension of trabecular architecture can be used to predict the mechanical properties of trabecular bone tissue. The elastic modulus and the ultimate strength (or strain) can then be estimated from non-invasive, non-radiating imaging and incorporated into the finite element models to more accurately represent the bone tissue of each individual of interest. Trabecular bone specimens from the proximal tibia are being studied in this first phase of the work. Detailed protocols and procedures have been developed for carrying test specimens through all of the steps of a multi-faceted test program. The test program begins with MRI and X-ray imaging of the whole bones before excising a smaller workpiece from the proximal tibia region. High resolution MRI scans are then made and the piece further cut into slabs (roughly 1 cm thick). The slabs are X-rayed again and also scanned using dual-energy X-ray absorptiometry (DEXA). Cube specimens are then cut from the slabs and tested mechanically in compression. Correlations between mechanical properties and fractal dimension will then be examined to assess and quantify the predictive capability of the fractal calculations.

Hogan, Harry A.↗

WISE 2005: LBNP Exercise and Flywheel Resistive Exercise as an Effective Countermeasure Combination

Long-term exposure to microgravity can cause a severe musculoskeletal loss and cardiovascular deconditioning in astronauts. In this report, the effectiveness of combined supine treadmill exercise in a lower body negative pressure chamber (LBNPex) and flywheel resistive exercise (Rex) countermeasures was determined to prevent bone loss, reduced aerobic upright exercise capacity and reduced muscle strength. We hypothesized that exercise subjects (EX) would show less decrease in bone mineral density (BMD), peak oxygen consumption (VO2pk) and knee extensor strength (KES) than control subjects (CON). Sixteen healthy female subjects (34 plus or minus 4yrs, 164 plus or minus 6.5cm, 58 plus or minus 5kg; mean plus or minus SD) participated in a 60-d 6 degree head-down tilt bed rest (BR) study after providing written informed consent. Subjects were assigned to one of two groups: a non- exercising CON group or an EX group performing LBNPex 2-4 d/wk and Rex every 3rd-d. VO2pk was measured with a maximal, graded, upright treadmill test performed pre-BR and on 3-d after BR. BMD was assessed pre-BR and 3-d after BR by dual energy x-ray absorptiometry total body DEXA scan (DEXA; HOLOGIC QDR 4500 Elite ). A Cybex dynamometer was employed to measure the isokinetic KES before and 5-d after BR. Two-way repeated measures ANOVA were performed with time as the repeated factor. Statistical significance was set at p less than 0.05. CON experienced a significant decrease in BMD in the trochanter (PRE: 0.670 0.045; POST: 0.646 0.352 g(raised dot) per square centimeter) and in the whole hip (PRE: 0.894 0.059; POST: 0.858 0.057 g(raised dot) per square centimeter). BMD also decreased significantly in EX in the trochanter (PRE: 0.753 plus or minus 0.0617; POST: 0.741 plus or minus 0.061 g(raised dot) per square centimeter) and whole hip (PRE: 0.954 plus or minus 0.067; POST: 0.935 plus or minus 0.069 g(raised dot) per square centimeter). BMD losses were significantly less in EX than in CON subjects. VO2pk was significantly decreased in the CON after BR (PRE: 38.0 plus or minus 4.8; POST: 29.9 plus or minus 4.2 ml(raised dot) per kilogram per minute), but not in the EX (PRE: 39.0 plus or minus 2.0; POST: 37.8 plus or minus 1.9 ml(raised dot) per kilogram per minute). KES was significantly reduced by 30% in CON (PRE: 113 plus or minus 12; POST: 78 plus or minus 8 N-m), but was not different in EX (PRE: 126 plus or minus 25; POST: 115 plus or minus 25 N-m). The combination LBNPex and Rex during 60-d BR protects against cardiovascular and musculoskeletal deconditioning and may be an efficacious countermeasure for prolonged space flight.

Meuche, S.↗

Visual-vestibular integration motion perception reporting

Self-orientation and self/surround-motion perception derive from a multimodal sensory process that integrates information from the eyes, vestibular apparatus, proprioceptive and somatosensory receptors. Results from short and long duration spaceflight investigations indicate that: (1) perceptual and sensorimotor function was disrupted during the initial exposure to microgravity and gradually improved over hours to days (individuals adapt), (2) the presence and/or absence of information from different sensory modalities differentially affected the perception of orientation, self-motion and surround-motion, (3) perceptual and sensorimotor function was initially disrupted upon return to Earth-normal gravity and gradually recovered to preflight levels (individuals readapt), and (4) the longer the exposure to microgravity, the more complete the adaptation, the more profound the postflight disturbances, and the longer the recovery period to preflight levels. While much has been learned about perceptual and sensorimotor reactions and adaptation to microgravity, there is much remaining to be learned about the mechanisms underlying the adaptive changes, and about how intersensory interactions affect perceptual and sensorimotor function during voluntary movements. During space flight, SMS and perceptual disturbances have led to reductions in performance efficiency and sense of well-being. During entry and immediately after landing, such disturbances could have a serious impact on the ability of the commander to land the Orbiter and on the ability of all crew members to egress from the Orbiter, particularly in a non-nominal condition or following extended stays in microgravity. An understanding of spatial orientation and motion perception is essential for developing countermeasures for Space Motion Sickness (SMS) and perceptual disturbances during spaceflight and upon return to Earth. Countermeasures for optimal performance in flight and a successful return to Earth require the development of preflight and in-flight training to help astronauts acquire and maintain a dual adaptive state. Despite the considerable experience with, and use of, an extensive set of countermeasures in the Russian space program, SMS and perceptual disturbances remain an unresolved problem on long-term flights. Reliable, valid perceptual reports are required to develop and refine stimulus rearrangements presented in the PAT devices currently being developed as countermeasures for the prevention of motion sickness and perceptual disturbances during spaceflight, and to ensure a less hazardous return to Earth. Prior to STS-8, crew member descriptions of their perceptual experiences were, at best, anecdotal. Crew members were not schooled in the physiology or psychology of sensory perception, nor were they exposed to the appropriate professional vocabulary. However, beginning with the STS-8 Shuttle flight, a serious effort was initiated to teach astronauts a systematic method to classify and quantify their perceptual responses in space, during entry, and after flight. Understanding, categorizing, and characterizing perceptual responses to spaceflight has been greatly enhanced by implementation of that training system.

Harm, Deborah L.↗

pH Sensitive Microcapsules for Delivery of Corrosion Inhibitors

A considerable number of corrosion problems can be solved by coatings. However, even the best protective coatings can fail by allowing the slow diffusion of oxygen and moisture to the metal surface. Corrosion accelerates when a coating delaminates. Often, the problems start when microscopic nicks or pits on the surface develop during manufacturing or through wear and tear. This problem can be solved by the incorporation of a self-healing function into the coating. Several new concepts are currently under development to incorporate this function into a coating. Conductive polymers, nanoparticles, and microcapsules are used to release corrosion-inhibiting ions at a defect site. The objective of this investigation is to develop a smart coating for the early detection and inhibition of corrosion. The dual function of this new smart coating system is performed by pH-triggered release microcapsules. The microcapsules can be used to deliver healing agents to terminate the corrosion process at its early stage or as corrosion indicators by releasing dyes at the localized corrosion sites. The dyes can be color dyes or fluorescent dyes, with or without pH sensitivity. Microcapsules were formed through the interfacial polymerization process. The average size of the microcapsules can be adjusted from 1 to 100 micron by adjusting the emulsion formula and the microcapsule forming conditions. A typical microcapsule size is around 10 microns with a narrow size distribution. The pH sensitivity of the microcapsule can also be controlled by adjusting the emulsion formula and the polymerization reaction time. Both corrosion indicator (pH indicator) and corrosion inhibitor containing microcapsules were formed and incorporated into paint systems. Test panels of selected steels and aluminum alloys were painted using these paints. Testing of compatibility between the microcapsule system and different paint systems are in progress. Initial experiments with the microcapsule containing paint show visible color changes at induced corrosion sites and improvement of corrosion protection. Further investigation of the performance of the coating using electrochemical techniques and long term exposure are currently underway.

Li, Wenyan↗

Statistical Engineering Toward Commercial Supersonic Flight: NASA's Quesst Mission

NASA’s Quesst Mission has dual goals of demonstrating low-noise supersonic technology in flight and surveying public reactions to low-noise supersonic overflight. For half a century, commercial aircraft have been required to fly slower than the speed of sound over land to prevent “creating an unacceptable situation” on the ground due to sonic booms. However, aircraft shaping techniques honed through decades of research have dramatically changed the way shockwaves from supersonic flight merge together as they travel to the ground. What used to sound like a boom on the ground will be transformed into a thump. NASA is now building a full-scale, piloted demonstration aircraft called the X-59 to demonstrate low-noise supersonic flight. In 2024, the X-59 aircraft will commence a national series of community overflight surveys to collect data on how people perceive “sonic thumps.” The results will be provided to national and international noise regulators as they consider creating new standards that allow commercial supersonic flight over land at acceptably low noise levels. In this presentation we provide historical context for the current prohibitions on supersonic commercial flight. Using data collected during earlier NASA tests, we demonstrate how generalized linear mixed models can be used to inform the functional dose-response curve. We also illustrate simulation experiments of the variability of sonic thump exposure across the United States. Finally, we discuss some of the challenges in designing the future community studies and generalizing them to a nationally-representative dose-response curve.

Quesst↗

The effect of space flight on spatial orientation

Both during and following early space missions, little neurosensory change in the astronauts was noted as a result of their exposure to microgravity. It is believed that this lack of in-flight adaptation in the spatial orientation and perceptual-motor system resulted from short exposure times and limited interaction with the new environment. Parker and Parker (1990) have suggested that while spatial orientation and motion information can be detected by a passive observer, adaptation to stimulus rearrangement is greatly enhanced when the observer moves through or acts on the environment. Experience with the actual consequences of action can be compared with those consequences expected on the basis of prior experience. Space flight today is of longer duration, and space craft volume has increased. These changes have forced the astronauts to interact with the new environment of microgravity, and as a result substantial changes occur in the perceptual and sensory-motor repsonses reflecting adaptation to the stimulus rearrangement of space flight. We are currently evaluating spatial orientation and the perceptual-motor systems' adaptation to microgravity by examining responses of postural control, head and gaze stability during locomotion, goal oriented vestibulo-ocular reflex (VOR), and structured quantitative perceptual reports. Evidence suggests that humans can successfully replace the gravitational reference available on Earth with cues available within the spacecraft or within themselves, but that adaptation to microgravity is not appropriate for a return to Earth. Countermeasures for optimal performance on-orbit and a successful return to earth will require development of preflight and in-flight training to help the astronauts acquire and maintain a dual adaptive state. An understanding of spatial orientation and motion perception, postural control, locomotion, and the VOR will aid in this process.

Reschke, Millard F.↗

Estimating Trabecular Bone Mechanical Properties From Non-Invasive Imaging

An important component in developing countermeasures for maintaining musculoskeletal integrity during long-term space flight is an effective and meaningful method of monitoring skeletal condition. Magnetic resonance imaging (MRI) is an attractive non-invasive approach because it avoids the exposure to radiation associated with X-ray based imaging and also provides measures related to bone microstructure rather than just density. The purpose of the research for the 1996 Summer Faculty Fellowship period was to extend the usefulness of the MRI data to estimate the mechanical properties of trabecular bone. The main mechanical properties of interest are the elastic modulus and ultimate strength. Correlations are being investigated between these and fractal analysis parameters, MRI relaxation times, apparent densities, and bone mineral densities. Bone specimens from both human and equine donors have been studied initially to ensure high-quality MR images. Specimens were prepared and scanned from human proximal tibia bones as well as the equine distal radius. The quality of the images from the human bone appeared compromised due to freezing artifact, so only equine bone was included in subsequent procedures since these specimens could be acquired and imaged fresh before being frozen. MRI scans were made spanning a 3.6 cm length on each of 5 equine distal radius specimens. The images were then sent to Dr. Raj Acharya of the State University of New York at Buffalo for fractal analysis. Each piece was cut into 3 slabs approximately 1.2 cm thick and high-resolution contact radiographs were made to provide images for comparing fractal analysis with MR images. Dual energy X-ray absorptiometry (DEXA) scans were also made of each slab for subsequent bone mineral density determination. Slabs were cut into cubes for mechanical using a slow-speed diamond blade wafering saw (Buehler Isomet). The dimensions and wet weights of each cube specimen were measured and recorded. Wet weights were also recorded. Each specimen was labeled and marked to denote anatomic orientations, i.e. superior/inferior (S/I), media/lateral (M/L), and anterior/posterior (A/P). The actual locations of each cube cut were documented and images distributed to define ROI locations for other analyses (to Raj Acharya for fractal analysis, to Jon Richardson at Baylor College of Medicine for DEXA, and to Chen Lin at Baylor College of Medicine for T2* MRI analysis). Quasistatic mechanical testing consisted of compressive loading in all three mutually perpendicular anatomic directions. Cyclic loading was applied for 10 cycles to precondition the specimen and results calculated for the eleventh. For one of three directions tested on each specimen, the 10 cycles were followed with loading to failure. Testing is currently proceeding and once completed the results will be correlated with data from the other analyses. One of the main points of interest is the relationship between fractal dimension and mechanical properties. Throughout preparation and testing all specimens were maintained hydrated with physiological saline and stored frozen when not being used.

Hogan, Harry A.↗

Virtual Reality as a Medium for Sensorimotor Adaptation Training and Spaceflight Countermeasures

Astronauts experience a profound sensorimotor adaptation during transition to and from the microgravity environment of space. With the upcoming shift to extra‐long duration missions (upwards of 1 year) aboard the International Space Station, the immediate risks to astronauts during these transitory periods become more important than ever to understand and prepare for. Recent advances in virtual reality technology enable everyday adoption of these tools for entertainment and use in training. Embedding an individual in a virtual environment (VE) allows the ability to change the perception of visual flow, elicit automatic motor behavior and produce sensorimotor adaptation, not unlike those required during long duration microgravity exposure. The overall goal of this study is to determine the feasibility of present head mounted display technology (HMD) to produce reliable visual flow information and the expected adaptation associated with virtual environment manipulation to be used in future sensorimotor adaptability countermeasures. To further understand the influence of visual flow on gait adaptation during treadmill walking, a series of discordant visual flow manipulations in a virtual environment are proposed. Six healthy participants (3 male and 3 female) will observe visual flow information via HMD (Oculus Rift DK2) while walking on an instrumented treadmill at their preferred walking speed. Participants will be immersed in a series of VE's resembling infinite hallways with different visual characteristics: an office hallway, a hallway with pillars and the hallway of a fictional spacecraft. Participants will perform three trials of 10 min. each, which include walking on the treadmill while receiving congruent or incongruent visual information via the HMD. In the first trial, participants will experience congruent visual information (baseline) where the hallway is perceived to move at the same rate as their walking speed. The final two trials will be randomized among participants where the hallway is perceived to move at either half (0.5x) or twice (2.0x) their preferred walking speed. Participants will remain on the treadmill between trials and will not be warned of the upcoming change to visual flow to minimize preparatory adjustments. Stride length, step frequency and dual‐support time will be quantified during each trial. We hypothesize that participants will experience a rapid modification in gait performance during periods of adaptive change, expressed as a decrease in step length, an increase in step frequency and an increase in dual‐support time, followed by a period of adaptation where these movement parameters will return to near‐baseline levels. As stride length, step frequency and dual support times return to baseline values, an adaptation time constant will be derived to establish individual time‐to‐adapt (TTA). HMD technology represents a paradigm shift in sensorimotor adaptation training where gait adaptability can be stressed using off‐the‐shelf consumer products and minimal experimental equipment, allowing for greater training flexibility in astronaut and terrestrial applications alike.

Madansingh, S.↗

A Novel Hybrid Ultramicrotomy/FIB-SEM Technique: Preparation of Serial Electron-Transparent Thin Sections of a Hayabusa Grain

The Japanese space agency's (JAXA) Hayabusa mission returned the first particulate samples (typically <100micron) from the surface of an asteroid (25143 Itokawa). These precious samples provide important insights into early Solar System processes, but their sizes pose tremendous challenges to coordinated analysis using a variety of nano- and micro-beam techniques. The ability to glean maximal information from individual particles has become increasingly important and depends critically on sample preparation. We developed a hybrid technique combining traditional ultramicrotomy with focused ion beam (FIB) techniques, allowing for more thorough in situ investigations of grain surfaces and interiors. Using this method, we increase the number of FIB-prepared sections that can be recovered from a particle with dimensions on the order of tens of microns. These sections can be subsequently analyzed using a variety of analytical techniques. Particle RA-QD02-0211 is a approx. 40×40×20 micron particle from Itokawa containing olivine and Fe sulfides. It was embedded in low viscosity epoxy and partly sectioned to a depth of approx 10 micron; sections are placed on Cu grids with thin amorphous films for transmission electron microscope (TEM) analyses. With the sample surface partly exposed, the epoxy bullet is trimmed to a height of approx. 5mm to accommodate the allowable dimensions for FIB work (FEI Quanta 600 3D dual beam FIB-SEM). Using a diamond trim knife, the epoxy surrounding the grain is removed on 3 sides (to within a few microns of the grain); the depth of material removed extends well below the bottom of the particle. The sample is attached to an SEM pin mount, the epoxy coated with conductive paint, and the entire assembly coated with approx. 40nm of carbon to eliminate sample charging during FIB work. A protective carbon cap is placed according to the plan for the 15 FIB sections. The central 'spine' of the cap runs perpendicular to the front of the sample, and the 'ribs' protruding from either side run parallel. Each rib indicates the location of a planned FIB section, and the spine contains the final two planned sections. We use a cap with a 4 micron-wide spine and 2micron-wide ribs that have ≳3.5 micron of space between them (narrower cuts result in too much re-deposition of material inside the trenches). Using a 30kV, 3nA ion-beam we expose the front surface of the grain and commence milling trenches between sections. Rather than using the typical C-cut to prepare the sample for lift-out, an L-cut is used instead, leaving the sample connected by an interior tab. tab. Sections are lifted out, attached to TEM grids and thinned to electron transparency. TEM analyses show that our hybrid technique preserves both interior and edge features, including surface modifications from exposure to the space environment, such as damaged rims that form in response to solar wind implantation effects and adhering grains. In addition, the FIB sections provide larger areas that are free of fractures and chatter effects in comparison to the microtome thin sections, thus enabling more accurate measurements of solar flare particle track densities that are used to determine the surface exposure age of the particles.

Berger, Eve L.↗

Biomechanical Modeling Analysis of Loads Configuration for Squat Exercise

INTRODUCTION: Long duration space travel will expose astronauts to extended periods of reduced gravity. Since gravity is not present to assist loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to minimize loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Unlike the International Space Station (ISS), the area available for an exercise device in the next generation of spacecraft for travel to the Moon or to Mars is limited and therefore compact resistance exercise device prototypes are being developed. The Advanced Resistive Exercise Device (ARED) currently on the ISS is being used as a benchmark for the functional performance of these new devices. Biomechanical data collection and computational modeling aid the device design process by quantifying the joint torques and the musculoskeletal forces that occur during exercises performed on the prototype devices. METHODS The computational models currently under development utilize the OpenSim [1] software platform, consisting of open source code for musculoskeletal modeling, using biomechanical input data from test subjects for estimation of muscle and joint loads. The OpenSim Full Body Model [2] is used for all analyses. The model incorporates simplified wrap surfaces, a new knee model and updated lower body muscle parameters derived from cadaver measurements and magnetic resonance imaging of young adults. The upper body uses torque actuators at the lumbar and extremity joints. The test subjects who volunteer for this study are instrumented with reflective markers for motion capture data collection while performing squat exercising on the Hybrid Ultimate Lifting Kit (HULK) prototype device (ZIN Technologies, Middleburg Heights, OH). Ground reaction force data is collected with force plates under the feet, and device loading is recorded through load cells internal to the HULK. Test variables include the applied device load and the dual cable long bar or single cable T-bar interface between the test subject and the device. Data is also obtained using free weights with the identical loading for a comparison to the resistively loaded exercise device trials. The data drives the OpenSim biomechanical model, which has been scaled to match the anthropometrics of the test subject, to calculate the body loads. RESULTS Lower body kinematics, joint moments, joint forces and muscle forces are obtained from the OpenSim biomechanical analysis of the squat exercises under different loading conditions. Preliminary results from the model for the loading conditions will be presented as will hypotheses developed for follow on work.

Human Factors Engineering↗