Search NASA⌕ Search

SEARCH · Search NASA

Results for “EAR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Physiological and Thermal Responses of MS Patients to Head and Vest Cooling: A Case Study

Personal cooling systems are used to alleviate symptoms of multiple sclerosis (MS) and to prevent increased core temperature during daily activities. The objective of this study was to determine the operating characteristics and the physiologic changes produced by short term application of the stationary thermal control system used by most clinical institutions. The Life Enhancement Tech (LET) Mark VII portable cooling system and a lightweight Head-vest active cooling garment were used to cool the head and chest regions of 4 male and 3 female MS patients (30 to 66 yrs. old) in this study. The subjects, seated in an upright position at normal room temperature (approx. 24 C), were tested for 60 min. with the liquid cooling garment (LCG) operated at 50 F. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures, heart rate, respiration, and an activity index were recorded continuously on a U.F.I., Inc., Biolog ambulatory monitor. All temperature responses showed extreme variation among subjects. The cold-sensitive subject's rectal temperature increased initially in response to cooling; the heat sensitive subject's rectal temperature decreased. After 40 min. of cooling and during recovery, all subjects'rectal temperatures decreased. Oral temperatures began to decrease after 30 min. of cooling. After 60 min. of cooling, temperature drops ranged from approx. 0.3 - 0.8 C. Oral temperatures continued to decrease during recovery (approx. 0.2 C). The car temperature of the heat sensitive subject was increased after cooling, other subjects exhibited an ear temperature decrease (0.0 - 0.5 C). These data indicate that head and vest cooling may be used to reduce the oral temperatures of MS patients by the approximate amount needed for symptomatic relief as shown by other researchers. The combination of a small subject population and a large subject variance does not permit us to draw statistical conclusions about the temperature response of MS patients. An individual's heat or cold sensitivity may influence their thermal response to cooling. This factor should be considered in the prescribed use of liquid cooling garments in the therapeutic management of MS.

Luna, Bernadette↗

Hearing Aid Assembly

Progress in hearing aids has come a long way. Yet despite such progress hearing aids are not the perfect answer to many hearing problems. Some adult ears cannot accommodate tightly fitting hearing aids. Mouth movements such as chewing, talking, and athletic or other active endeavors also lead to loosely fitting ear molds. It is well accepted that loosely fitting hearing aids are the cause of feedback noise. Since feedback noise is the most common complaint of hearing aid wearers it has been the subject of various patents. Herein a hearing aid assembly is provided eliminating feedback noise. The assembly includes the combination of a hearing aid with a headset developed to constrict feedback noise.

Grugel, Richard N.↗

Ribbon Synaptic Plasticity in Gravity Sensors of Rats Flown on Neurolab

Previous spaceflight experiments (Space Life Sciences-1 and -2 (SLS-1 and SLS-2)) first demonstrated the extraordinary ability of gravity sensor hair cells to change the number, kind, and distribution of connections (synapses) they make to other cells while in weightlessness. The number of synapses in hair cells in one part of the inner ear (the utricle) was markedly elevated on flight day 13 (FD13) of SLS-2. Unanswered questions, however, were whether these increases in synapses occur rapidly and whether they remain stable in weightlessness. The answers have implications for long-duration human space travel. If gravity sensors can adapt quickly, crews may be able to move easily between different gravity levels, since the sensors will adapt rapidly to weightlessness on the spacecraft and then back to Earth's gravity when the mission ends. This ability to adapt is also important for recovery from balance disorders. To further our understanding of this adaptive potential (a property called neuronal synaptic plasticity), the present Neurolab research was undertaken. Our experiment examined whether: (a) increases in synapses would remain stable throughout the flight, (b) changes in the number of synapses were uniform across different portions of the gravity sensors (the utricle and saccule), and (c) synaptic changes were similar for the different types of hair cells (Type I and Type II). Utricular and saccular maculae (the gravity-sensing portions of the inner ear) were collected in flight from rats on FD2 and FD14. Samples were also collected from control rats on the ground. Tissues were prepared for ultrastructural study. Hair cells and their ribbon synapses were examined in a transmission electron microscope. Synapses were counted in all hair cells in 50 consecutive sections that crossed the striolar zone. Results indicate that utricular hair cell synapses initially increased significantly in number in both types of hair cells by FD2. Counts declined by FD14, but the mean number of synapses in utricular Type II cells remained significantly higher than in the ground control rats. For saccular samples, synaptic number in Type I and Type II cells declined on FD2, but returned to near-baseline values by FD14. These findings indicate that: (a) synaptic plasticity occurs rapidly in weightlessness, and (b) synaptic changes are not identical for the two types of hair cells or for the two maculae.

Ross, Muriel D.↗

Caspase inhibitors promote vestibular hair cell survival and function after aminoglycoside treatment in vivo

The sensory hair cells of the inner ear undergo apoptosis after acoustic trauma or aminoglycoside antibiotic treatment, causing permanent auditory and vestibular deficits in humans. Previous studies have demonstrated a role for caspase activation in hair cell death and ototoxic injury that can be reduced by concurrent treatment with caspase inhibitors in vitro. In this study, we examined the protective effects of caspase inhibition on hair cell death in vivo after systemic injections of aminoglycosides. In one series of experiments, chickens were implanted with osmotic pumps that administrated the pan-caspase inhibitor z-Val-Ala-Asp(Ome)-fluoromethylketone (zVAD) into inner ear fluids. One day after the surgery, the animals received a 5 d course of treatment with streptomycin, a vestibulotoxic aminoglycoside. Direct infusion of zVAD into the vestibule significantly increased hair cell survival after streptomycin treatment. A second series of experiments determined whether rescued hair cells could function as sensory receptors. Animals treated with streptomycin displayed vestibular system impairment as measured by a greatly reduced vestibulo-ocular response (VOR). In contrast, animals that received concurrent systemic administration of zVAD with streptomycin had both significantly greater hair cell survival and significantly increased VOR responses, as compared with animals treated with streptomycin alone. These findings suggest that inhibiting the activation of caspases promotes the survival of hair cells and protects against vestibular function deficits after aminoglycoside treatment.

NASA Discipline Neuroscience↗

Photosynthetic capacity and dry mass partitioning in dwarf and semi-dwarf wheat (Triticum aestivum L.)

Efficient use of space and high yields are critical for long-term food production aboard the International Space Station. The selection of a full dwarf wheat (less than 30 cm tall) with high photosynthetic and yield potential is a necessary prerequisite for growing wheat in the controlled, volume-limited environments available aboard long-term spaceflight missions. This study evaluated the photosynthetic capacity and carbon partitioning of a full-dwarf wheat cultivar, Super Dwarf, which is routinely used in spaceflight studies aboard U.S. space shuttle and NASA/Mir missions and made comparisons with other dwarf and semi-dwarf wheat cultivars utilized in other ground-based studies in plant space biology. Photosynthetic capacity of the flag leaf in two dwarf (Super Dwarf, BB-19), and three semi-dwarf (Veery-10, Yecora Rojo, IBWSN 199) wheat cultivars (Triticum aestivum L.) was assessed by measuring: net maximum photosynthetic rate, RuBP carboxylation efficiency, chlorophyll concentration and flag leaf area. Dry mass partitioning of carbohydrates to the leaves, sheaths, stems and ear was also assessed. Plants were grown under controlled environmental conditions in three replicate studies: slightly enriched CO2 (370 micromoles mol-1), high photosynthetic photon flux (1000 micromoles m-2 s-1; 58 mol m-2 d-1) for a 16 h photoperiod, 22/15 degrees C day/night temperatures, ample nutrients and water provided by one-half strength Hoagland's nutrient solution (Hoagland and Arnon, 1950). Photosynthetic capacity of the flag leaf was determined at anthesis using net CO2 exchange rate versus internal CO2 concentration curves measured under saturating light (2000 micromoles m-2 s-1) and CO2 (1000 micromoles mol-1). Dwarf wheat cultivars had greater photosynthetic capacities than the taller semi-dwarfs, they averaged 20% higher maximum net photosynthetic rates compared to the taller semi-dwarfs, but these higher rates occurred only at anthesis, had slightly greater carboxylation efficiencies and significantly increased chlorophyll concentrations per unit leaf area. The reduced-height wheat had significantly less dry mass fraction in the stem but greater dry mass partitioned to the ear than the taller semi-dwarfs (Yecora rojo, IBWSN-199). Studies with detached heads confirm that the head is a significant sink in the shorter wheat cultivars.

Non-NASA Center↗

Perception of tilt (somatogravic illusion) in response to sustained linear acceleration during space flight

During the 1998 Neurolab mission (STS-90), four astronauts were exposed to interaural and head vertical (dorsoventral) linear accelerations of 0.5 g and 1 g during constant velocity rotation on a centrifuge, both on Earth and during orbital space flight. Subjects were oriented either left-ear-out or right-ear-out (Gy centrifugation), or lay supine along the centrifuge arm with their head off-axis (Gz centrifugation). Pre-flight centrifugation, producing linear accelerations of 0.5 g and 1 g along the Gy (interaural) axis, induced illusions of roll-tilt of 20 degrees and 34 degrees for gravito-inertial acceleration (GIA) vector tilts of 27 degrees and 45 degrees , respectively. Pre-flight 0.5 g and 1 g Gz (head dorsoventral) centrifugation generated perceptions of backward pitch of 5 degrees and 15 degrees , respectively. In the absence of gravity during space flight, the same centrifugation generated a GIA that was equivalent to the centripetal acceleration and aligned with the Gy or Gz axes. Perception of tilt was underestimated relative to this new GIA orientation during early in-flight Gy centrifugation, but was close to the GIA after 16 days in orbit, when subjects reported that they felt as if they were 'lying on side'. During the course of the mission, inflight roll-tilt perception during Gy centrifugation increased from 45 degrees to 83 degrees at 1 g and from 42 degrees to 48 degrees at 0.5 g. Subjects felt 'upside-down' during in-flight Gz centrifugation from the first in-flight test session, which reflected the new GIA orientation along the head dorsoventral axis. The different levels of in-flight tilt perception during 0.5 g and 1 g Gy centrifugation suggests that other non-vestibular inputs, including an internal estimate of the body vertical and somatic sensation, were utilized in generating tilt perception. Interpretation of data by a weighted sum of body vertical and somatic vectors, with an estimate of the GIA from the otoliths, suggests that perception weights the sense of the body vertical more heavily early in-flight, that this weighting falls during adaptation to microgravity, and that the decreased reliance on the body vertical persists early post-flight, generating an exaggerated sense of tilt. Since graviceptors respond to linear acceleration and not to head tilt in orbit, it has been proposed that adaptation to weightlessness entails reinterpretation of otolith activity, causing tilt to be perceived as translation. Since linear acceleration during in-flight centrifugation was always perceived as tilt, not translation, the findings do not support this hypothesis.

STS-90 Shuttle Project↗

Gravitoinertial force magnitude and direction influence head-centric auditory localization

We measured the influence of gravitoinertial force (GIF) magnitude and direction on head-centric auditory localization to determine whether a true audiogravic illusion exists. In experiment 1, supine subjects adjusted computer-generated dichotic stimuli until they heard a fused sound straight ahead in the midsagittal plane of the head under a variety of GIF conditions generated in a slow-rotation room. The dichotic stimuli were constructed by convolving broadband noise with head-related transfer function pairs that model the acoustic filtering at the listener's ears. These stimuli give rise to the perception of externally localized sounds. When the GIF was increased from 1 to 2 g and rotated 60 degrees rightward relative to the head and body, subjects on average set an acoustic stimulus 7.3 degrees right of their head's median plane to hear it as straight ahead. When the GIF was doubled and rotated 60 degrees leftward, subjects set the sound 6.8 degrees leftward of baseline values to hear it as centered. In experiment 2, increasing the GIF in the median plane of the supine body to 2 g did not influence auditory localization. In experiment 3, tilts up to 75 degrees of the supine body relative to the normal 1 g GIF led to small shifts, 1--2 degrees, of auditory setting toward the up ear to maintain a head-centered sound localization. These results show that head-centric auditory localization is affected by azimuthal rotation and increase in magnitude of the GIF and demonstrate that an audiogravic illusion exists. Sound localization is shifted in the direction opposite GIF rotation by an amount related to the magnitude of the GIF and its angular deviation relative to the median plane.

NASA Discipline Neuroscience↗

Spatial orientation and balance control changes induced by altered gravitoinertial force vectors

To better understand the mechanisms of human adaptation to rotating environments, we exposed 19 healthy subjects and 8 vestibular-deficient subjects ("abnormal"; four bilateral and four unilateral lesions) to an interaural centripetal acceleration of 1 g (resultant 45 degrees roll-tilt of 1.4 g) on a 0.8-m-radius centrifuge for periods of 90 min. The subjects sat upright (body z-axis parallel to centrifuge rotation axis) in the dark with head stationary, except during 4 min of every 10 min, when they performed head saccades toward visual targets switched on at 3- to 5-s intervals at random locations (within +/- 30 degrees) in the earth-horizontal plane. Eight of the normal subjects also performed the head saccade protocol in a stationary chair adjusted to a static roll-tilt angle of 45 degrees for 90 min (reproducing the change in orientation but not the magnitude of the gravitoinertial force on the centrifuge). Eye movements, including voluntary saccades directed along perceived earth- and head-referenced planes, were recorded before, during, and immediately after centrifugation. Postural center of pressure (COP) and multisegment body kinematics were also gathered before and within 10 min after centrifugation. Normal subjects overestimated roll-tilt during centrifugation and revealed errors in perception of head-vertical provided by directed saccades. Errors in this perceptual response tended to increase with time and became significant after approximately 30 min. Motion-sickness symptoms caused approximately 25% of normal subjects to limit their head movements during centrifugation and led three normal subjects to stop the test early. Immediately after centrifugation, subjects reported feeling tilted 10 degrees in the opposite direction, which was in agreement with the direction of their earth-referenced directed saccades. Postural COP, segmental body motion amplitude, and hip-sway frequency increased significantly after centrifugation. These postural effects were short-lived, however, with a recovery time of several postural test trials (minutes). There were also asymmetries in the direction of postcentrifugation COP and head tilt which depended on the subject's orientation during the centrifugation adaptation period (left ear or right ear out). The amount of total head movements during centrifugation correlated poorly or inversely with postcentrifugation postural stability, and the most unstable subject made no head movements. There was no decrease in postural stability after static tilt, although these subjects also reported a perceived tilt briefly after return to upright, and they also had COP asymmetries. Abnormal subjects underestimated roll-tilt during centrifugation, and their directed saccades revealed permanent spatial distortions. Bilateral abnormal subjects started out with poor postural control, but showed no postural decrements after centrifugation, while unilateral abnormal subjects had varying degrees of postural decrement, both in their everyday function and as a result of experiencing the centrifugation. In addition, three unilateral, abnormal subjects, who rode twice in opposite orientations, revealed a consistent orthogonal pattern of COP offsets after centrifugation. These results suggest that both orientation and magnitude of the gravitoinertial vector are used by the central nervous system for calibration of multiple orientation systems. A change in the background gravitoinertial force (otolith input) can rapidly initiate postural and perceptual adaptation in several sensorimotor systems, independent of a structured visual surround.

Clinical Trial↗

Ocular counterrolling induced by centrifugation during orbital space flight

During the 1998 Neurolab mission (STS-90), four astronauts were exposed to interaural centripetal accelerations (Gy centrifugation) of 0.5 g and 1 g during rotation on a centrifuge, both on Earth and during orbital space flight. Subjects were oriented either left-ear out or right-ear out, facing or back to motion. Binocular eye movements were measured in three dimensions using a video technique. On Earth, tangential centrifugation that produces 1 g of interaural linear acceleration combines with gravity to tilt the gravitoinertial acceleration (GIA) vector 45 degrees in the roll plane relative to the head vertical, generating a summed vector of 1.4 g. Before flight, this elicited mean ocular counterrolling (OCR) of 5.7 degrees. Due to the relative absence of gravity during flight, there was no linear acceleration along the dorsoventral axis of the head. As a result, during in-flight centrifugation, gravitoinertial acceleration was strictly aligned with the centripetal acceleration along the interaural axis. There was a small but significant decrease (mean 10%) in the magnitude of OCR in space (5.1 degrees). The magnitude of OCR during postflight 1 g centrifugation was not significantly different from preflight OCR (5.9 degrees). Findings were similar for 0.5 g centrifugation, but the OCR magnitude was approximately 60% of that induced by centrifugation at 1 g. OCR during pre- and postflight static tilt was not significantly different and was always less than OCR elicited by centrifugation of Earth for an equivalent interaural linear acceleration. In contrast, there was no difference between the OCR generated by in-flight centrifugation and by static tilt on Earth at equivalent interaural linear accelerations. These data support the following conclusions: (1) OCR is generated predominantly in response to interaural linear acceleration; (2) the increased OCR during centrifugation on Earth is a response to the head dorsoventral 1 g linear acceleration component, which was absent in microgravity. The dorsoventral linear acceleration could have activated either the otoliths or body-tilt receptors that responded to the larger GIA magnitude (1.4 g), to generate the increased OCR during centrifugation on Earth. A striking finding was that magnitude of OCR was maintained throughout and after flight. This is in contrast to most previous postflight OCR studies, which have generally registered decreases in OCR. We postulate that intermittent exposure to artificial gravity, in the form of the centripetal acceleration experienced during centrifugation, acted as a countermeasure to deconditioning of this otolith-ocular orienting reflex during the 16-day mission.

Non-NASA Center↗

EphB2 guides axons at the midline and is necessary for normal vestibular function

Mice lacking the EphB2 receptor tyrosine kinase display a cell-autonomous, strain-specific circling behavior that is associated with vestibular phenotypes. In mutant embryos, the contralateral inner ear efferent growth cones exhibit inappropriate pathway selection at the midline, while in mutant adults, the endolymph-filled lumen of the semicircular canals is severely reduced. EphB2 is expressed in the endolymph-producing dark cells in the inner ear epithelium, and these cells show ultrastructural defects in the mutants. A molecular link to fluid regulation is provided by demonstrating that PDZ domain-containing proteins that bind the C termini of EphB2 and B-ephrins can also recognize the cytoplasmic tails of anion exchangers and aquaporins. This suggests EphB2 may regulate ionic homeostasis and endolymph fluid production through macromolecular associations with membrane channels that transport chloride, bicarbonate, and water.

Non-NASA Center↗

Otoconia biogenesis, phylogeny, composition and functional attributes

This work consolidates data about these interesting organic crystals of vertebrate inner ears. It addresses 5 aspects of inner ear otoliths not completely understood to date: 1) embryological data that explains the formation of the crystals, 2) the significance of the organic and the inorganic phase of the otolith and the changing patterns of otoconia formation along the evolutionary tree, 3) otoliths contribution for detecting linear acceleration, 4) the effect that altered gravity and aminoglycosides have on the development and adult shape of the crystals, and the evolutionary significance of a changing shape of the crystals from primitive forms (lamprey) to high vertebrate birds and mammals is discussed, 5) functional attributes of the otolithic organs and morphological modifications of the otoliths by physical and chemical insults are presented with an extensive discussion of the most relevant literature published and available to us.

Non-NASA Center↗

Kinematic principles of primate rotational vestibulo-ocular reflex. II. Gravity-dependent modulation of primary eye position

The kinematic constraints of three-dimensional eye positions were investigated in rhesus monkeys during passive head and body rotations relative to gravity. We studied fast and slow phase components of the vestibulo-ocular reflex (VOR) elicited by constant-velocity yaw rotations and sinusoidal oscillations about an earth-horizontal axis. We found that the spatial orientation of both fast and slow phase eye positions could be described locally by a planar surface with torsional variation of <2.0 +/- 0.4 degrees (displacement planes) that systematically rotated and/or shifted relative to Listing's plane. In supine/prone positions, displacement planes pitched forward/backward; in left/right ear-down positions, displacement planes were parallel shifted along the positive/negative torsional axis. Dynamically changing primary eye positions were computed from displacement planes. Torsional and vertical components of primary eye position modulated as a sinusoidal function of head orientation in space. The torsional component was maximal in ear-down positions and approximately zero in supine/prone orientations. The opposite was observed for the vertical component. Modulation of the horizontal component of primary eye position exhibited a more complex dependence. In contrast to the torsional component, which was relatively independent of rotational speed, modulation of the vertical and horizontal components of primary position depended strongly on the speed of head rotation (i.e., on the frequency of oscillation of the gravity vector component): the faster the head rotated relative to gravity, the larger was the modulation. Corresponding results were obtained when a model based on a sinusoidal dependence of instantaneous displacement planes (and primary eye position) on head orientation relative to gravity was fitted to VOR fast phase positions. When VOR fast phase positions were expressed relative to primary eye position estimated from the model fits, they were confined approximately to a single plane with a small torsional standard deviation ( approximately 1.4-2.6 degrees). This reduced torsional variation was in contrast to the large torsional spread (well >10-15 degrees ) of fast phase positions when expressed relative to Listing's plane. We conclude that primary eye position depends dynamically on head orientation relative to space rather than being fixed to the head. It defines a gravity-dependent coordinate system relative to which the torsional variability of eye positions is minimized even when the head is moved passively and vestibulo-ocular reflexes are evoked. In this general sense, Listing's law is preserved with respect to an otolith-controlled reference system that is defined dynamically by gravity.

NASA Discipline Neuroscience↗

What is the minimal vestibular function required for compensation?

Living with an uncompensated, abnormal vestibular system requires oppressive modification of life style and often prevents return to work and activities of daily living. Patients with vestibular abnormalities were studied to determine the minimal residual vestibular function required to achieve compensation. Three groups of patients with (a) complete unilateral loss of vestibular function with normal horizontal canal-vestibulo-ocular (HCVOR) function in the opposite ear, (b) complete unilateral loss with abnormal HCVOR function in the opposite ear, and (c) bilateral reduction of vestibular function from aminoglycoside toxicity underwent vestibuloocular (VOR), optokinetic (OKN), visual-VOR (VVOR), and computerized dynamic posturography (CDP) tests before and after therapeutic procedures. Results suggest that a minimal VOR response amplitude must be present for compensation of VVOR function to occur. The roles of VOR and OKN phase shifts in vestibular compensation are more complicated and require further study. Compensation of vestibulospinal function does not necessarily accompany VOR or VVOR compensation. Ascending and descending vestibular compensatory mechanisms may involve different spatial sensory inputs. Results of these studies have important implications for the diagnosis and treatment of patients with vestibular disorders, including selection and monitoring of patients for therapeutic regimens such as vestibular nerve section and streptomycin therapy.

Non-NASA Center↗

Elliptical-P cells in the avian perilymphatic interface of the Tegmentum vasculosum

Elliptical cells (E-P) are present at the perilymphatic interface lumen (PIL) of the lagena. The E-P cells often separate from the tegmentum vasculosum (TV) and have touching processes that form a monolayer between the K+ rich perilymph and the Na+ rich endolymph, similar to the mammalian Reissner's membrane. We examined the TV of chicks (Gallus domesticus) and quantitated the expression of anti-S100 alphaalphabetabeta and S100 beta. There was a 30% increase of S100 beta saturation in the light cells facing the PIL when compared to other TV light cells. We show that: (1) the dimer anti- S100 alphaalphabetabeta and the monomer anti-S100 beta are expressed preferentially in the light cells and the E-P cells of TV; (2) expression of S100 beta is higher in light cells facing the PIL than in adjacent cells; (3) the expression of the dimer S100 alphaalphabetabeta and monomer S100 beta overlaps in most inner ear cell types, including the cells of the TV, most S100 alphaalphabetabeta positive cells express S 100 beta, but S100 beta positive cells do not always express S100 alphaalphabetabeta; and (4) the S100 beta expression in light cells, the abundant Na+-K+ ATPase on dark cells of the TV, and previously demonstrated co-localization of S100 beta/GABA in sensory cells suggest that S100 beta could have, in the inner ear, a dual neurotrophic-ionic modulating function.

NASA Discipline Neuroscience↗

Conventional and cross-correlation brain-stem auditory evoked responses in the white leghorn chick: rate manipulations

Rate-dependent changes in the chick brain-stem auditory evoked response (BAER) using conventional averaging and a cross-correlation technique were investigated. Five 15- to 19-day-old white leghorn chicks were anesthetized with Chloropent. In each chick, the left ear was acoustically stimulated. Electrical pulses of 0.1-ms duration were shaped, attenuated, and passed through a current driver to an Etymotic ER-2 which was sealed in the ear canal. Electrical activity from stainless-steel electrodes was amplified, filtered (300-3000 Hz) and digitized at 20 kHz. Click levels included 70 and 90 dB peSPL. In each animal, conventional BAERs were obtained at rates ranging from 5 to 90 Hz. BAERs were also obtained using a cross-correlation technique involving pseudorandom pulse sequences called maximum length sequences (MLSs). The minimum time between pulses, called the minimum pulse interval (MPI), ranged from 0.5 to 6 ms. Two BAERs were obtained for each condition. Dependent variables included the latency and amplitude of the cochlear microphonic (CM), wave 2 and wave 3. BAERs were observed in all chicks, for all level by rate combinations for both conventional and MLS BAERs. There was no effect of click level or rate on the latency of the CM. The latency of waves 2 and 3 increased with decreasing click level and increasing rate. CM amplitude decreased with decreasing click level, but was not influenced by click rate for the 70 dB peSPL condition. For the 90 dB peSPL click, CM amplitude was uninfluenced by click rate for conventional averaging. For MLS BAERs, CM amplitude was similar to conventional averaging for longer MPIs.(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Discipline Neuroscience↗

Journal of Gravitational Physiology, Volume 12, Number 1

The following topics were covered: System Specificity in Responsiveness to Intermittent -Gx Gravitation during Simulated Microgravity in Rats; A Brief Overview of Animal Hypergravity Studies; Neurovestibular Adaptation to Short Radius Centrifugation; Effect of Artificial Gravity with Exercise Load by Using Short-Arm Centrifuge with Bicycle Ergometer as a Countermeasure Against Disused Osteoporosis; Perception of Body Vertical in Microgravity during Parabolic Flight; Virtual Environment a Behavioral and Countermeasure Tool for Assisted Gesture in Weightlessness: Experiments during Parabolic Flight; Artificial Gravity: Physiological Perspectives for Long-Term Space Exploration; Comparison of the Effects of DL-threo-Beta-Benzyloxyaspartate on the Glutamate Release from Synaptosomes before and after Exposure of Rats to Artificial Gravity; Do Perception and Postrotatory Vestibulo-Ocular Reflex Share the Same Gravity Reference?; Vestibular Adaptation to Changing Gravity Levels and the Orientation of Listing's Plane; Compound Mechanism Hypothesis on +Gz - Induced Brain Injury and Dysfunction of Learning and Memory; Environmental Challenge Impairs Prefrontal Brain Functions; Effect of 6-Days of Support Withdrawal on Characteristics of Balance Function; Hypergravity-Induced Changes of Neuronal Activities in CA1 Region of Rat Hippocampus; Audiological Findings in Antiorthostatic Position Modelling Microgravitation; Investigating Human Cognitive Performance during Spaceflight; The Relevance of the Minimization of Torque Exchange with the Environment in Weightlessness is Confirmed by Asimulation Study; Characteristics of the Eyes Pursuit Function during Readaptation to Terrestrial Gravity after Prolonged Flights Aboard the International Space Station; Comparison of Cognitive Performance Tests for Promethazine Pharmacodynamics in Human Subjects; Structural Reappraisal of Dendritic Tree of Cerebellar Purkinje Cell for Novel Functional Modeling of Elementary Sensorimotor Adaptive Processes; Orpheus 0 G or Ear in Microgravity to Establish Symptoms Concomittant of Inner and Middle Ear and Osteoporosis in Microgravity; Understanding Visual Perception in the Perspective of Gravity; Cortical Regions Associated with Orthostatic Stress in Conscious Humans; Restoration of Central Blood Volume: Application of a Simple Concept and Simple Device to Counteract Cardiovascular Instability in Syncope and Hemorrhage; WISE-2005: Integrative Cardiovascular Responses with LBNP during 60-Day Bed Rest in Women; Intracranial Pressure Increases during Weightlessness. A Parabolic Flights Study; Lower Limb & Portal Veins Echography for Predicting Risk of Thrombosis during a 90-D Bed Rest; Calf Tissue Liquid Stowage and Muscular and Deep Vein Distension in Orthostatic Tests after a 90-Day Head Down Bed Rest; Morphology of Brain Vessels in the Tail Suspended Rats Exposed to Intermittent 2 G; Alterations in Vasoreactivity of Femoral Artery Induced by Hindlimb Unweighting are Related to the Changes of Contractile Protein in Rats; and Respiratory Sinus Arrhythmia: A Marker of Decreased Parasympathetic Modulation after Short Duration.

Fuller, Charles A.↗

Medical Devices Assess, Treat Balance Disorders

You may have heard the phrase as difficult as walking and chewing gum as a joking way of referring to something that is not difficult at all. Just walking, however, is not all that simple physiologically speaking. Even standing upright is an undertaking requiring the complex cooperation of multiple motor and sensory systems including vision, the inner ear, somatosensation (sensation from the skin), and proprioception (the sense of the body s parts in relation to each other). The compromised performance of any of these elements can lead to a balance disorder, which in some form affects nearly half of Americans at least once in their lifetimes, from the elderly, to those with neurological or vestibular (inner ear) dysfunction, to athletes with musculoskeletal injuries, to astronauts returning from space. Readjusting to Earth s gravity has a significant impact on an astronaut s ability to balance, a result of the brain switching to a different "model" for interpreting sensory input in normal gravity versus weightlessness. While acclimating, astronauts can experience headaches, motion sickness, and problems with perception. To help ease the transition and study the effects of weightlessness on the body, NASA has conducted many investigations into post-flight balance control, realizing this research can help treat patients with balance disorders on Earth as well. In the 1960s, the NASA-sponsored Man Vehicle Laboratory at the Massachusetts Institute of Technology (MIT) studied the effects of prolonged space flight on astronauts. The lab s work intrigued MIT doctoral candidate Lewis Nashner, who began conducting NASA-funded research on human movement and balance under the supervision of Dr. Larry Young in the MIT Department of Aeronautics and Astronautics. In 1982, Nashner s work resulted in a noninvasive clinical technique for assessing the cooperative systems that allow the body to balance, commonly referred to as computerized dynamic posturography (CDP). CDP employs a series of dynamic protocols to isolate and assess balance function deficiencies. The technology was based on Nashner s novel, engineering-inspired concept of balance as an adaptable collaboration between multiple sensory and motor systems. CDP proved useful not only for examining astronauts, but for anyone suffering from balance problems. Today, CDP is the standard medical tool for objectively evaluating balance control.

Source record↗

Advanced Infant Car Seat Would Increase Highway Safety

An advanced infant car seat has been proposed to increase highway safety by reducing the incidence of crying, fussy behavior, and other child-related distractions that divert an adult driver s attention from driving. In addition to a conventional infant car seat with safety restraints, the proposed advanced infant car seat would include a number of components and subsystems that would function together as a comprehensive infant-care system that would keep its occupant safe, comfortable, and entertained, and would enable the driver to monitor the baby without having to either stop the car or turn around to face the infant during driving. The system would include a vibrator with bulb switch to operate; the switch would double as a squeeze toy that would make its own specific sound. A music subsystem would include loudspeakers built into the seat plus digital and analog circuitry that would utilize plug-in memory modules to synthesize music or a variety of other sounds. The music subsystem would include a built-in sound generator that could synthesize white noise or a human heartbeat to calm the baby to sleep. A second bulb switch could be used to control the music subsystem and would double as a squeeze toy that would make a distinct sound. An anti-noise sound-suppression system would isolate the baby from potentially disturbing ambient external noises. This subsystem would include small microphones, placed near the baby s ears, to detect ambient noise. The outputs of the microphone would be amplified and fed to the loudspeakers at appropriate amplitude and in a phase opposite that of the detected ambient noise, such that the net ambient sound arriving at the baby s ears would be almost completely cancelled. A video-camera subsystem would enable the driver to monitor the baby visually while continuing to face forward. One or more portable miniature video cameras could be embedded in the side of the infant car seat (see figure) or in a flip-down handle. The outputs of the video cameras would be transmitted by radio or infrared to a portable, miniature receiver/video monitor unit that would be attached to the dashboard of the car. The video-camera subsystem can also be used within transmission/reception range when the seat was removed from the car. The system would include a biotelemetric and tracking subsystem, which would include a Global Positioning System receiver for measuring its location. This subsystem would transmit the location of the infant car seat (even if the seat were not in a car) along with such biometric data as the baby s heart rate, perspiration rate, urinary status, temperature, and rate of breathing. Upon detecting any anomalies in the biometric data, this subsystem would send a warning to a paging device installed in the car or carried by the driver, so that the driver could pull the car off the road to attend to the baby. A motion detector in this subsystem would send a warning if the infant car seat were to be moved or otherwise disturbed unexpectedly while the infant was seated in it: this warning function, in combination with the position- tracking function, could help in finding a baby who had been kidnapped with the seat. Removable rechargeable batteries would enable uninterrupted functioning of all parts of the system while transporting the baby to and from the car. The batteries could be recharged via the cigarette-lighter outlet in the car or by use of an external AC-powered charger.

Dabney, Richard↗