Search NASA⌕ Search

SEARCH · Search NASA

Results for “ECCS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Off-Gas Generation Rate during Chemical Cleaning Operations at the Savannah River Site - 12499

The enhanced chemical cleaning process (ECC) is being developed at the Savannah River Site (SRS) to remove the residual radioactive sludge heel that remains in a liquid waste storage tank. Oxalic acid is the chemical agent utilized for this purpose. However, the acid also corrodes the carbon steel tank wall and cooling coils. If the oxalic acid has little interaction with the sludge, hydrogen gas could conceivably evolve at cathodic areas due to the corrosion of the carbon steel. Scenarios where hydrogen evolution could occur during ECC include the initial filling of the tank prior to agitation and near the end of the process when there is little or no sludge present. The purpose of this activity was to provide a bounding estimate for the hydrogen generation rate during the ECC process. Sealed vessel coupon tests were performed to estimate the hydrogen generation rate due to corrosion of carbon steel by oxalic acid. These tests determined the maximum instantaneous hydrogen generation rate, the rate at which the generation rate decays, and the total hydrogen generated. The tests were performed with polished ASTM A285 Grade C carbon steel coupons. This steel is representative of the Type I and II waste tanks at SRS. Bounding conditions were determined for the solution environment. The oxalic acid concentration was 2.5 wt.% and the test temperature was 75 deg. C. The test solution was agitated and contained no sludge simulant. Duplicate tests were performed and showed excellent reproducibility for the hydrogen generation rate and total hydrogen generated. The results showed that the hydrogen generation rate was initially high, but decayed rapidly within a couple of days. A statistical model was developed to predict the instantaneous hydrogen generation rate as a function of exposure time by combining both sets of data. An upper bound on the maximum hydrogen generation rate was determined from the upper 95% confidence limit. The upper bound limit on the maximum instantaneous generation rate at 5 hours was 6.1 x 10{sup -5} m{sup 3}/m{sup 2}/minute. After two and five days the upper bound limit decayed to 7.9 x 10{sup -6} and 1.3 x 10{sup -6} m{sup 3}/m{sup 2}/minute, respectively. The total volume of hydrogen gas generated during the test was calculated from the model equation. An upper bound on the total gas generated was determined from the upper 95% confidence limit. The upper bound limit on the total hydrogen generated during the 163 hour test was 0.101 m{sup 3}/m{sup 2}. Corrosion rates were determined from the coupon tests and also calculated from the measured hydrogen generation rates. Excellent agreement was achieved between the time averaged corrosion rate calculated from the hydrogen generation rates and the corrosion rates determined from the coupon tests. The corrosion rates were on the order of 0.45 mmpy. Good agreement was also observed between the maximum instantaneous corrosion rate as calculated from the hydrogen generation rate and the corrosion rate determined by previous electrochemical tests. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Future Electron-Ion Collider

Generalized Parton Distributions include rich information and became a powerful tool for studying hadron structure. Deeply Virtual Compton Scattering is the golden channel to access GPDs. The development of high luminosity and high-acceptance detectors (Electron-Ion Collider) allows physicists to overcome the difficulty of DVCS measurements. The outstanding performance of the accelerator performs the eA collisions at the center of mass energy from 20 to 140 GeV, while the luminosity at the scale of 1034 cm?2s?1. The new type of high-density crystal, PWO-II, produced by CRYTUR in 2×2×20 cm3 will be utilized in the calorimeter. The transparency of PWO-II crystals is > 70% at 620 nm, > 60% at 420 nm, and >35% at 360 nm. The crystals also show good radiation hardness under 30 Gy radiation exposure. Ten PWO-II crystals have a uniform light yield at 30 p.e./MeV, providing sufficient light yield to reduce the fluctuation of the energy measurements. Near 3000 crystals were constructed inside the 12-sided polygon supporting structure in the simulation. The island clustering algorithm was used for reconstructed the energy. The energy resolution study by the particle gun shows the stochastic term and constant term are 1.8% and 1.2%, respectively. The spatial resolution of NEEMC varies from 5% to 15% of the crystal?s width depending on the particle?s incident angle. The pion rejection of NEEMC can reach 103 with electron efficiency > 85% when the particle?s energy is larger than 1GeV. The Pi0- identified efficiency study can be interpreted as finding the local maxima in the single cluster caused by two high energy close photons. The study results show that efficiency is nearly 100% for pi0 energy is smaller than 10 GeV, and efficiency drops to 30% with 20 GeV pi0. The new type of 3x3 pixelated AC-LGAD were wire bonded to ALTIROC for performance test. The cross-talk between the adjacent channels is about 20% for VPA and 10% for TZ. A series of the TDC characteristic measurements show that the jitter for both preamplifiers is about 20 ps, and the time-walk effect is mild for inject charge > 12 pF. Furthermore, the beta source radiation results quantify the sharing scale of the 3x3 pixels AC-LGAD (? 20%). The electronics simulation study results show no significant changes in the spatial resolution, whether ADC resolution is 8, 10, or 12 bits. The 8-bit ADC is decided to use in the EICROC as it has a smaller size and power consumption than the 10-bit and 12-bit ADC. The ECCE is one of the full detector proposals for EIC. The new type of DVCS generator, called TOPEG, is used to generate the high acceptance beam configurations of 18×110 GeV2 electron and 4He. The acceptance study shows a -1.8 < ? < -1.4 gap between the BEMC and EEMC. The 10?x,y geometry cut is applied on the Roman Pots, so the acceptance of Roman Pots quickly drops to 0% when the polar angle of the recoiled 4He < 2 mrad. This primary ECCE simulation study suggests extending the acceptance of BEMC longitudinally as the structure limits the radial size of EEMC. The acceptance of the Roman Pots is still challenging. In 2023, The overall design of ePIC was finalized by merging two full detector proposals (ECCE and ATHENA) after a series of intensive simulation studies.

Wang, Pu-Kai↗

The behavior of ANGRA 2 nuclear power plant core for a small break LOCA simulated with RELAP5 code

This work discusses the behavior of Angra 2 nuclear power plant core, for a postulate Loss of Coolant Accident (LOCA) in the primary circuit for Small Break Loss Of Coolant Accident (SBLOCA). A pipe break of the hot leg Emergency Core Cooling System (ECCS) was simulated with RELAP 5 code. The considered rupture area is 380 cm{sup 2}, which represents 100% of the ECCS pipe flow area. Results showed that the cooling is enough to guarantee the integrity of the reactor core.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

RISMC Industry Application no. 1 (ECCS/LOCA) - Core Characterization Automation: Lattice Codes Interface for PHISICS/RELAP5-3D

The U.S. NRC is currently proposing rulemaking '10 CFR 50.46c' to revise the loss-of-coolant-accident (LOCA) and emergency core cooling system (ECCS) acceptance criteria to include the effects of higher burn-up on cladding performance. The key implications of this proposition are that the cladding performance cannot be evaluated in isolation anymore. Both cladding and ECCS performance need to be considered in a coupled manner. This also implies that models for cladding performance as well as LOCA methodologies will need to be updated for regulatory purposes. Furthermore, efforts need to be made to find the limiting case within the regulatory input space. The Risk-Informed Safety Margin Characterization (RISMC) Pathway, as part of the DOE Light Water Reactor Sustainability (LWRS) research and development program initialed several programs at the Idaho National Laboratory (INL) to support the industry in the transition to the new rule and to offer potential solutions to this LOCA/ECCS analysis. One of these programs is the Industry Application no. 1 (IA1). Its purpose is to provide to the plant owner/operator a vehicle to inform decisions to manage margins related to compliance with the proposed 10 CFR 50.46c rule. IA1's goal is to develop an Integrated Evaluation Model (IEM) to revisit how uncertainties are propagated across the physical disciplines and data involved, as well as well as how risks are evaluated in a LOCA under 10 CFR 50.46c. This IEM is called LOCA Tool-kit for the US (LOTUS) and it connects five major disciplines involved in LOCA analysis. The focus of LOTUS is to establish the automation interfaces among the five disciplines. LOTUS will utilize in a first step existing computer codes. The risk-informed margins management approach for IA1 will provide a means of quantifying the impact on the key LOCA analysis figures-of-merit like peak cladding temperature (PCT), equivalent cladding reacted (ECR), etc. of a change in LOCA analysis inputs. The information that the risk analysis and associated tools provide can then be used for decision-making and margin management. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sensitivity Tests of Aluminum Precipitate Preparation Methods on Head Loss through Debris Beds on a Sump Screen

During a Loss-of-Coolant Accident (LOCA) in Pressurized Water Reactors (PWRs), buffered borated water as a coolant from the Refueling Water Storage Tank (RWST) will be injected into the primary loop to cool down the core depending on the break size. For long-term cooling, the coolant will be collected in the containment sump. Then, the Emergency Core Cooling System (ECCS) will pump the coolant through the sump strainers into the reactor. During this phase, buffered borated water produces chemical precipitate by reacting with the structural materials in the containment. Chemical effects evaluated as part of Generic Safety Issue 191 (GSI-191) resolution studies are broadly defined as any chemically induced phenomenon that affects ECCS performance. Initial chemical effects studies jointly sponsored by the Nuclear Regulatory Commission (NRC) and Industry collaborators led to a Westinghouse Owners Group (WOG) study that provided bases for deterministic quantification of chemical effects. The WCAP-16530-NP developed protocols to produce Aluminum Oxyhydroxide (AlOOH), Calcium Phosphate, and Sodium Aluminum Silicate (SAS). The surrogate generation protocol used the metal salt (aluminum nitrate and calcium acetate) unlike post-LOCA accident scenarios where metals leach into a buffered borated solution. Bahn et al. demonstrated that the WCAP-16530-NP SAS precipitate did not produce as much head loss as the WCAP-16530-NP AlOOH precipitate, thus, the present study focused on the effect of AlOOH precipitate on head loss through a fibrous debris bed. In the past, most of the tests were conducted in high approach velocity conditions, approximately 0.03 m/s. After modifications of sump strainer size in PWRs, the approach velocity to the sump strainer was reduced by an order of magnitude, approximately 0.001 ∼ 0.003 m/s. Howe et al. and Kim et al. conducted several head loss tests at the approach velocity of 0.003 m/s. In the present study, an approach velocity of 0.0006 m/s was selected for an extremely slow power plant condition. A PCI strainer design was used as previous head loss tests and debris bypass tests conducted by Lee et al. Three different chemical precipitate preparation methods were used in this study. The additional head loss of the debris bed caused by those chemical precipitates was investigated. The debris bed was produced with NUKON{sup R} fiberglass thermal insulator and additional particulates including dirt, Tin powder, acrylic powder, and Calcium silicate (CalSil). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

RISMC Industry Application no. 1 (ECCS/LOCA) Core characterization automation: Reference PWR designs for IA no. 1

The U.S. NRC is currently proposing rulemaking '10 CFR 50.46c' to revise the loss-of-coolant-accident (LOCA) and emergency core cooling system (ECCS) acceptance criteria to include the effects of higher burn-up on cladding performance. The key implications of this proposition are that both cladding and ECCS performance need to be considered in a coupled manner. This implies that LOCA methodologies will need to be updated for regulatory purposes. The Risk-Informed Safety Margin Characterization (RISMC) Pathway, as part of the DOE Light Water Reactor Sustainability (LWRS) research and development program initialed several programs at the Idaho National Laboratory (INL) to support the industry by offering potential solutions to this new LOCA/ECCS analysis. One of these programs is the Industry Application no. 1 (IA1). It's goal is to develop an integrated evaluation model called LOCA Toolkit for the US (LOTUS) to revisit how risks are evaluated in a LOCA under 10 CFR 50.46c. The focus of LOTUS is to establish the automation interfaces among the physics disciplines involved, namely the core design automation, the fuels/clad performance, the system analysis, the risk assessment and the core design optimization. The risk-informed margins management approach for IA1 will provide a means of quantifying the impact on the key LOCA analysis figures-of-merit like peak cladding temperature (PCT), equivalent cladding reacted (ECR), etc. of a change in LOCA analysis inputs. The information obtained can then be used for decision-making and margin management. The modular approach for LOTUS will enable plant owners/vendors to further customize the LOTUS framework for use within their established codes and methods. One of the LOTUS modules deals with the core design automation (CD-A). The purpose of this module is to supply the LOCA analysis with initial conditions, i.e. assembly/pin power histories, power shapes, etc. to be employed by the Fuels/Clad Performance (EP) and System Analysis (SA) modules. In the CD-A module, the plant owner/operator will characterize his core design with the tools he has. For the current LOTUS demonstration, the tools used are the already coupled codes PHISICS and RELAP5-3D2,3. Cross section generation will be done using the Studsvik lattice code HELIOS-2.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Microstructure and Magnetic Properties of Exchange-Coupled Co{sub 72}Pt{sub 28}/Pt/Co{sub 81}Ir{sub 19} Composite Media for Perpendicular Magnetic Recording

In this work, we report the investigation of microstructure and magnetic properties of the Co{sub 72}Pt{sub 28}/Pt/Co{sub 81}Ir{sub 19} exchange-coupled composite (ECC) media using soft-layer (SL) of Co{sub 81}Ir{sub 19} with negative magnetocrystalline anisotropy (MA). Our TEM images show that the hard-layer (HL) exhibits a columnar type microstructure with well-isolated grains and the exchange-coupled SL with hcp-structure show the same texture. Strong coupling of the two layers have been evidenced by the magnetic characterization for all the studied films with Pt inter-layer thickness ranging from 0 to 2 nm. Importantly, these ECC media films have much lower coercivities and much higher thermal stabilities in the favor of high-density magnetic recording.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spot-Scanning-Based Proton Therapy for Extracranial Chordoma

Purpose: To evaluate effectiveness and safety of spot-scanning-based proton-radiotherapy (PT) for extracranial chordomas (ECC). Methods and Material: Between 1999-2006, 40 patients with chordoma of C-, T-, and L-spine and sacrum were treated at Paul Scherrer Institute (PSI) with PT using spot-scanning. Median patient age was 58 years (range, 10-81 years); 63% were male, and 36% were female. Nineteen patients (47%) had gross residual disease (mean 69 cc; range, 13-495 cc) before PT, and 21 patients (53%) had undergone prior titanium-based surgical stabilization (SS) and reconstruction of the axial skeleton. Proton doses were expressed as Gy(RBE). A conversion factor of 1.1 was used to account for higher relative biological effectiveness (RBE) of protons compared with photons. Mean total dose was 72.5 Gy(RBE) [range, 59.4-75.2 Gy(RBE)] delivered at 1.8-2.0 Gy(RBE) dose per fraction. Median follow-up time was 43 months. Results: In 19 patients without surgical stabilization, actuarial local control (LC) rate at 5 years was 100%. LC for patients with gross residual disease but without surgical stabilization was also 100% at 5 years. In contrast, 12 failures occurred in 21 patients with SS, yielding a significantly decreased 5-year LC rate of 30% (p = 0.0003). For the entire cohort, 5-year LC rates were 62%, disease-free survival rates were 57%, and overall survival rates were 80%. Rates were 100% for patients without SS. No other factor, including dosimetric parameters (V95, V80) were predictive for tumor control on univariate analysis. Conclusion: Spot-scanning-based PT at PSI delivered subsequently to function-preserving surgery for tumor debulking, decompression of spinal cord, or biopsy only is safe and highly effective in patients with ECC without major surgical instrumentation even in view of large, unresectable disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of iron-chromium-aluminum samples exposed to accident conditions followed by quench in the QUENCH-19 experiment

The QUENCH-19 experiment was a first-of-its-kind full-bundle test simulating accident conditions followed by water quench on accident-tolerant fuel (ATF) cladding. Here, a type of FeCrAl(Y) alloy, B136Y3, was developed at Oak Ridge National Laboratory and tested at the Karlsruhe Institute of Technology using Kanthal APM corner rods, a shroud, and Kanthal AF spacer grids. Testing conditions were similar to those in QUENCH-15—which tested ZIRLO cladding behavior—so that B136Y3 and ZIRLO cladding could be compared. QUENCH-19 consisted of an initial pre-oxidation heating followed by a transient. Then, a maximum power hold, which was not present in QUENCH-15, was executed to extend the heating period for the FeCrAl(Y) rods. Finally, a rapid water quench was executed that was similar to emergency core coolant system (ECCS) actuation. Compared with the ZIRLO rods in QUENCH-15, the bundle in QUENCH-19 released significantly less H 2 (9.2 g vs. 47.6 g) and achieved a much lower maximum temperature (1455°C vs. 1880°C). Furthermore, no breakaway oxidation was observed in QUENCH-19. Metallographic mounts revealed that despite the symmetry of the setup, at elevations near the maximum temperature, cladding and thermocouples were heavily damaged, substantial melting and oxidation occurred, and the cladding underwent chemical interaction with the thermocouple sheaths. Additionally, the ZrO 2 spacers detrimentally interacted with the cladding, leading to mixed oxide debris and the full destruction of some rods. Additional failure was found in certain cooler rods that may have risen due to the high thermal expansion coefficient of FeCrAl alloys. This paper presents an analysis of this work, which suggests that FeCrAl cladding can chemically survive anticipated loss-of-coolant accident events followed by rapid ECCS quench if the correct geometry and core design are present.

36 MATERIALS SCIENCE↗

Comparison of dislocation characterization by electron channeling contrast imaging and cross-correlation electron backscattered diffraction

In this paper, the relative capabilities and limitations of electron channeling contrast imaging (ECCI) and cross-correlation electron backscattered diffraction (CC-EBSD) have been assessed by studying the dislocation distributions resulting from nanoindentation in body centered cubic Ta. Qualitative comparison reveals very similar dislocation distributions between the CC-EBSD mapped GNDs and the ECC imaged dislocations. Approximate dislocation densities determined from ECC images compare well to those determined by CC-EBSD. Nevertheless, close examination reveals subtle differences in the details of the distributions mapped by these two approaches. Finally, the details of the dislocation Burgers vectors and line directions determined by ECCI have been compared to those determined using CC-EBSD and reveal good agreement.

36 MATERIALS SCIENCE↗

Troponin T3 regulates nuclear localization of the calcium channel Ca{sub v}β{sub 1a} subunit in skeletal muscle

The voltage-gated calcium channel (Ca{sub v}) β{sub 1a} subunit (Ca{sub v}β{sub 1a}) plays an important role in excitation–contraction coupling (ECC), a process in the myoplasm that leads to muscle-force generation. Recently, we discovered that the Ca{sub v}β{sub 1a} subunit travels to the nucleus of skeletal muscle cells where it helps to regulate gene transcription. To determine how it travels to the nucleus, we performed a yeast two-hybrid screening of the mouse fast skeletal muscle cDNA library and identified an interaction with troponin T3 (TnT3), which we subsequently confirmed by co-immunoprecipitation and co-localization assays in mouse skeletal muscle in vivo and in cultured C2C12 muscle cells. Interacting domains were mapped to the leucine zipper domain in TnT3 COOH-terminus (160–244 aa) and Ca{sub v}β{sub 1a} NH{sub 2}-terminus (1–99 aa), respectively. The double fluorescence assay in C2C12 cells co-expressing TnT3/DsRed and Ca{sub v}β{sub 1a}/YFP shows that TnT3 facilitates Ca{sub v}β{sub 1a} nuclear recruitment, suggesting that the two proteins play a heretofore unknown role during early muscle differentiation in addition to their classical role in ECC regulation. - Highlights: • Previously, we demonstrated that Ca{sub v}β{sub 1a} is a gene transcription regulator. • Here, we show that TnT3 interacts with Ca{sub v}β{sub 1a}. • We mapped TnT3 and Ca{sub v}β{sub 1a} interaction domain. • TnT3 facilitates Ca{sub v}β{sub 1a} nuclear enrichment. • The two proteins play a heretofore unknown role during early muscle differentiation.

60 APPLIED LIFE SCIENCES↗

Software Analytical Instrument for Assessment of the Process of Casting Slabs

The paper describes the original proposal of ways of solution and function of the program equipment for assessment of the process of casting slabs. The program system LITIOS was developed and implemented in EVRAZ Vitkovice Steel Ostrava on the equipment of continuous casting of steel (further only ECC). This program system works on the data warehouse of technological parameters of casting and quality parameters of slabs. It enables an ECC technologist to analyze the course of casting melt and with using statistics methods to set the influence of single technological parameters on the duality of final slabs. The system also enables long term monitoring and optimization of the production.

36 MATERIALS SCIENCE↗

Design and numerical simulation of a high power capacity relativistic backward wave oscillator with an electron collection cavity

A high power capacity relativistic backward wave oscillator with an electron collection cavity (ECC) placed at the downstream of the slow wave structure (SWS) is presented. The breakdown threshold is increased, and the density of seed electron is suppressed by preventing the secondary electron, plasma, and powder generated from the bombardment of spent electron beam on the surface of the collector drifting to the extractor and beam-wave interaction region. The maximum longitudinal electric field in the device is reduced through extension of the span between electron beam and slow wave structure and weakening the Cerenkov radiation. The conversion efficiency reaches up to 52% owing to enhanced transit time radiation taking place at the entrance of the ECC. The maximum longitudinal electric field is 1.1 MV/cm on the surface of SWSs when the output power is 7.3 GW and the power capacity improves significantly.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

GAS EMISSIONS IN PLANCK COLD DUST CLUMPS-A SURVEY OF THE J = 1-0 TRANSITIONS OF {sup 12}CO, {sup 13}CO, AND C{sup 18}O

A survey toward 674 Planck cold clumps of the Early Cold Core Catalogue (ECC) in the J = 1-0 transitions of {sup 12}CO, {sup 13}CO, and C{sup 18}O has been carried out using the Purple Mountain Observatory 13.7 m telescope. Six hundred seventy-three clumps were detected with {sup 12}CO and {sup 13}CO emission, and 68% of the sample has C{sup 18}O emission. Additional velocity components were also identified. A close consistency of the three line peak velocities was revealed for the first time. Kinematic distances are given for all the velocity components, and half of the clumps are located within 0.5 and 1.5 kpc. Excitation temperatures range from 4 to 27 K, slightly larger than those of T{sub d} . Line width analysis shows that the majority of ECC clumps are low-mass clumps. Column densities N{sub H{sub 2}} span from 10{sup 20} to 4.5 Multiplication-Sign 10{sup 22} cm{sup -2} with an average value of (4.4 {+-} 3.6) Multiplication-Sign 10{sup 21} cm{sup -2}. N{sub H{sub 2}} cumulative fraction distribution deviates from the lognormal distribution, which is attributed to optical depth. The average abundance ratio of the {sup 13}CO to C{sup 18}O in these clumps is 7.0 {+-} 3.8, higher than the terrestrial value. Dust and gas are well coupled in 95% of the clumps. Blue profile asymmetry, red profile asymmetry, and total line asymmetry were found in less than 10% of the clumps, generally indicating that star formation is not yet developed. Ten clumps were mapped. Twelve velocity components and 22 cores were obtained. Their morphologies include extended diffuse, dense, isolated, cometary, and filament, of which the last is the majority. Twenty cores are starless, and only seven cores seem to be in a gravitationally bound state. Planck cold clumps are the most quiescent among the samples of weak red IRAS, infrared dark clouds, UC H II candidates, extended green objects, and methanol maser sources, suggesting that Planck cold clumps have expanded the horizon of cold astronomy.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiation-Induced Error Mitigation by Read-Retry Technique for MLC 3-D NAND Flash Memory

Here, we have evaluated the Read-Retry (RR) functionality of the 3-D NAND chip of multilevel-cell (MLC) configuration after total ionization dose (TID) exposure. The RR function is typically offered in the high-density state-of-the-art NAND memory chips to recover data once the default memory read method fails to correct data with error correction codes (ECCs). In this work, we have applied the RR method on the irradiated 3-D NAND chip that was exposed with a Co-60 gamma-ray source for TID up to 50 krad (Si). Based on our experimental evaluation results, we have proposed an algorithm to efficiently implement the RR method to extend the radiation tolerance of the NAND memory chip. Our experimental evaluation shows that the RR method coupled with ECC can ensure data integrity of MLC 3-D NAND for TID up to 50 krad (Si).

3-D NAND↗

Memory Errors in Modern Systems: The Good, The Bad, and The Ugly

Several recent publications have shown that hardware faults in the memory subsystem are commonplace. These faults are predicted to become more frequent in future systems that contain orders of magnitude more DRAM and SRAM than found in current memory subsystems. These memory subsystems will need to provide resilience techniques to tolerate these faults when deployed in high-performance computing systems and data centers containing tens of thousands of nodes. Therefore, it is critical to understand the efficacy of current hardware resilience techniques to determine whether they will be suitable for future systems. In this paper, we present a study of DRAM and SRAM faults and errors from the field. We use data from two leadership-class high-performance computer systems to analyze the reliability impact of hardware resilience schemes that are deployed in current systems. Our study has several key findings about the efficacy of many currently deployed reliability techniques such as DRAM ECC, DDR address/command parity, and SRAM ECC and parity. We also perform a methodological study, and find that counting errors instead of faults, a common practice among researchers and data center operators, can lead to incorrect conclusions about system reliability. Lastly, we use our data to project the needs of future large-scale systems. We find that SRAM faults are unlikely to pose a significantly larger reliability threat in the future, while DRAM faults will be a major concern and stronger DRAM resilience schemes will be needed to maintain acceptable failure rates similar to those found on today's systems.

97 MATHEMATICS AND COMPUTING↗

TREATMENT TANK OFF-GAS TESTING FOR THE ENHANCED CHEMICAL CLEANING PROCESS

The purpose of this activity was to provide a bounding estimate of the volume of hydrogen gas generated during Enhanced Chemical Cleaning (ECC) of residual sludge remaining in a Type I or Type II treatment tank as well as to provide results independent of the sludge volume in the waste tank to be cleaned. Previous testing to support Chemical Cleaning was based on a 20:1 oxalic acid to sludge ratio. Hydrogen gas evolution is the primary safety concern. Sealed vessel coupon tests were performed to estimate the hydrogen generation rate due to corrosion of carbon steel by 2.5 wt.% oxalic acid. These tests determined the maximum instantaneous hydrogen generation rate, the rate at which the generation rate decays, and the total hydrogen generated. These values were quantified based on a small scale methodology similar to the one described in WSRC-STI-2007-00209, Rev. 0. The measured rates support identified Safety Class functions. The tests were performed with ASTM A285 Grade C carbon steel coupons. Bounding conditions were determined for the solution environment. The oxalic acid concentration was 2.5 wt.% and the test temperature was 75 C. The test solution was agitated and contained no sludge simulant. Duplicate tests were performed and showed excellent reproducibility for the hydrogen generation rate and total hydrogen generated. The results showed that the hydrogen generation rate was initially high, but decayed rapidly within a couple of days. A statistical model was developed to predict the instantaneous hydrogen generation rate as a function of exposure time by combining both sets of data. An upper bound on the maximum hydrogen generation rate was determined from the upper 95% confidence limit. The upper bound confidence limit for the hydrogen generation rate is represented by the following equation. ln (G{sub v}) = -8.22-0.0584 t + 0.0002 t{sup 2}. This equation should be utilized to estimate the instantaneous hydrogen generation rate per unit surface area, G{sub v}, at a given time, t. The units for G{sub v} and t are ft{sup 3}/ft{sup 2}/min and hours, respectively. The total volume of hydrogen gas generated during the test was calculated from the model equation. An upper bound on the total gas generated was determined from the upper 95% confidence limit. The upper bound limit on the total hydrogen generated during the 163 hour test was 0.332 ft{sup 3}/ft{sup 2}. The maximum instantaneous hydrogen generation rate for this scenario is greater than that previously measured in the 8 wt.% oxalic acid tests due to both the absence of sludge in the test (i.e., greater than 20:1 ratio of acid to sludge) and the use of polished coupons (vs. mill scale coupons). However, due to passivation of the carbon steel surface, the corrosion rate decays by an order of magnitude within the first three days of exposure such that the instantaneous hydrogen generation rates are less than that previously measure in the 8 wt.% oxalic acid tests. While the results of these tests are bounding, the conditions used in this study may not be representative of the ECC flowsheet, and the applicability of these results to the flowsheet should be evaluated for the following reasons: (1) The absence of sludge results in higher instantaneous hydrogen generation rates than when the sludge is present; and (2) Polished coupons do not represent the condition of the carbon steel interior of the tank, which are covered with mill scale. Based on lower instantaneous corrosion rates measured on mill scale coupons exposed to oxalic acid, lower instantaneous hydrogen generation rates are expected for the tank interior than measured on the polished coupons. Corrosion rates were determined from the coupon tests and also calculated from the measured hydrogen generation rates. Excellent agreement was achieved between the time averaged corrosion rate calculated from the hydrogen generation rates and the corrosion rates determined from the coupon tests. The corrosion rates were on the order of 18 to 28 mpy. Good agreement was also observed between the maximum instantaneous corrosion rate as calculated from the hydrogen generation rate and the corrosion rate determined by previous electrochemical tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of Flexibility Options on Grid Economic Carrying Capacity of Solar and Wind: Three Case Studies

In this study, we attempt to quantify the benefits of various options of grid flexibility by measuring their impact on two measures: economic carrying capacity and system costs. Flexibility can increase ECC and reduce overall system costs. In some cases, options that provide a limited increase in ECC can provide significant operational savings, thus demonstrating the need to evaluate flexibility options using multiple metrics. The value of flexibility options varies regionally due to different generation mixes and types of renewables. The more rapid decline in PV value compared to wind makes PV more dependent on adding flexibility options, including transmission and energy storage.

14 SOLAR ENERGY↗