Search NASA⌕ Search

SEARCH · Search NASA

Results for “EIS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Properties of the Inter-area Modes of the U.S. Eastern Interconnection System

With an increase in the oscillation events observed in the U.S. Eastern Interconnection (EI), it has become increasingly important to have a good understanding of the EI system oscillatory behavior. However, as compared to the Western Interconnection system (WI), not much work has been done in this regard for the EI system. Therefore, in this paper, a thorough analysis is carried out to identify inter-area modes and their properties for the EI system using model-based approach. Multi-channel Prony method is used in this paper for estimating system modes and mode-shapes.

Agrawal, Urmila↗

Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method

Using electrochemical impedance spectroscopy, we have devised a method of sensing the microscopic surface conditions on the surface of niobium as it is undergoing an electrochemical polishing (EP) treatment. The method uses electrochemical impedance spectroscopy (EIS) to gather information on the surface state of the electrode without disrupting the polishing reaction. The EIS data is analyzed using a so-called distribution of relaxation times (DRT) method. Using DRT, the EIS data can be deconvolved into discrete relaxation time peaks without any a priori knowledge of the electrode dynamics. By analyzing the relaxation time peaks, we are able to distinguish two distinct modes of the EP reaction. As the polishing voltage is increased, the electrode transitions from the low voltage EP mode, characterized by a single relaxation time peaks, to the high voltage EP mode, characterized by two relaxation time peaks. We theorize that this second peak is caused by the formation of an oxide layer on the electrode. We also find that this oxide induced peak transitions from to a negative relaxation time, which is indicative of a blocking electrode process. By analyzing EPed samples, we show that samples polished in the low voltage mode have significantly higher surface roughness due to grain etching and faceting. We find that the surface roughness of the samples only improves when the oxide film peak is present and in the negative relaxation time region. This shows that EIS combined with DRT analysis can be used to predict etching on EPed Nb. This method can also be performed before or during the EP, which could allow for adjustment of polishing parameters to guarantee a smooth cavity surface finish.

43 PARTICLE ACCELERATORS↗

Identifying electrochemical processes by distribution of relaxation times in proton exchange membrane electrolyzers

Distribution of relaxation time (DRT) is used to interpret electrochemical impedance spectroscopy (EIS) for proton exchange membrane (PEM) water electrolyzers, with an attempt to separate overlapped relaxation processes in Nyquist plots. By varying operating conditions and catalyst loadings, four main relaxation peaks arising from EIS can be identified and successfully separated from low to high frequencies as (P1) mass transport, (P2) oxygen evolution reaction kinetics, (P3) reaction kinetics (with faster time constant than P2), and (P4) ionic transport. Here, the shape, height, and frequency of the DRT peaks change with different membrane electrode assembly (MEA) configurations. Electron microscopy reveals distinct features from the cross-sectioned MEAs which verify critical DRT results in that increasing the iridium (Ir)-anode loading from 0.2 mgIr/cm 2 to 1.5 mgIr/cm 2 reduces kinetic losses due to higher site-access; a thick and compacted anode, however, also triggers higher ohmic resistances from membrane/catalyst layer hydration and increases transport losses due to longer ionomer pathways. DRT provides higher resolution to EIS for deconvoluting processes with different relaxation times and the quantification of DRT peaks improves the accounting of total losses from each process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the Impact of Granularity of Space-Based Urban CO2 Emissions in Urban Atmospheric Inversions: A Case Study for Indianapolis, IN

Quantifying greenhouse gas (GHG) emissions from cities is a key challenge towards effective emissions management. An inversion analysis from the INdianapolis FLUX experiment (INFLUX) project, as the first of its kind, has achieved a top-down emission estimate for a single city using CO2 data collected by the dense tower network deployed across the city. However, city-level emission data, used as a priori emissions, are also a key component in the atmospheric inversion framework. Currently, fine-grained emission inventories (EIs) able to resolve GHG city emissions at high spatial resolution, are only available for few major cities across the globe. Following the INFLUX inversion case with a global 1x1 km ODIAC fossil fuel CO2 emission dataset, we further improved the ODIAC emission field and examined its utility as a prior for the city scale inversion. We disaggregated the 1x1 km ODIAC non-point source emissions using geospatial datasets such as the global road network data and satellite-data driven surface imperviousness data to a 3030 m resolution. We assessed the impact of the improved emission field on the inversion result, relative to priors in previous studies (Hestia and ODIAC). The posterior total emission estimate (5.1 MtC/yr) remains statistically similar to the previous estimate with ODIAC (5.3 MtC/yr). However, the distribution of the flux corrections was very close to those of Hestia inversion and the model-observation mismatches were significantly reduced both in forward and inverse runs, even without hourly temporal changes in emissions. EIs reported by cities often do not have estimates of spatial extents. Thus, emission disaggregation is a required step when verifying those reported emissions using atmospheric models. Our approach offers gridded emission estimates for global cities that could serves as a prior for inversion, even without locally reported EIs in a systematic way to support city-level Measuring, Reporting and Verification (MRV) practice implementation.

EIs↗

How reliable is distribution of relaxation times (DRT) analysis? A dual regression-classification perspective on DRT estimation, interpretation, and accuracy

The distribution of relaxation times (DRT) has gained increasing attention and adoption in recent years as a versatile method for analyzing electrochemical impedance spectroscopy (EIS) data obtained from complex devices like fuel cells, electrolyzers, and batteries. The DRT deconvolutes the impedance without a priori specification of a generative model, which is especially useful for interpretation and model selection when the governing principles of the system under study are not fully understood. However, DRT estimation is an ill-posed inversion problem that must be addressed with a subjective choice of regularization and tuning, which leaves substantial risk of misleading interpretations of EIS data. In this work, we suggest a new classification view of the DRT inversion to clarify DRT estimation and interpretation. We introduce a dual regression-classification framework that unifies the classification and regression views of the DRT inversion with wide-reaching implications for DRT analysis. The dual framework is employed to demonstrate a new kind of DRT inversion algorithm and develop novel evaluation metrics that capture previously ignored aspects of DRT accuracy. These approaches are applied to both synthetic data and experimental spectra collected from a protonic ceramic fuel cell and a lithium-ion battery to illustrate their broad utility. The dual inversion algorithm shows promising performance for accurate DRT estimation and autonomous model identification, while the dual evaluation approach produces metrics that meaningfully assess the strengths and risks of DRT algorithms. Here this work provides valuable insight for both practical application of the DRT to experimental data and further development of EIS analysis methods.

36 MATERIALS SCIENCE↗

Overestimated Eddy Kinetic Energy in the Eddy‐Rich Regions Simulated by Eddy‐Resolving Global Ocean–Sea Ice Models

Abstract The performance of eddy‐resolving global ocean–sea ice models in simulating mesoscale eddies is evaluated using six eddy‐resolving experiments forced by different atmospheric reanalysis products. Interestingly, eddy‐resolving ocean general circulation models (OGCMs) tend to simulate more (less) energetic eddy‐rich (eddy‐poor) regions with a smaller (larger) spatial extent than satellite observation, which finally shows that larger (smaller) mesoscale energy intensity (EI) is simulated in the eddy‐rich (eddy‐poor) regions. Quantitatively, there is an approximately 27%–60% overestimation of EI in the eddy‐rich regions, which are mainly located in the Kuroshio–Oyashio Extension, the Gulf Stream, and the Antarctic Circumpolar Currents regions, although the global mean EI is underestimated by 25%–45%. Apparently, the eddy kinetic energy in the eddy‐poor region is underestimated. Further analyses based on coherent mesoscale eddy properties show that the overestimation in the eddy‐rich regions is mainly attributed to mesoscale eddies’ intensity and is more prominent when mesoscale eddies are in their growth stage.

54 ENVIRONMENTAL SCIENCES↗

Signatures of the exciton gas phase and its condensation in monolayer 1T-ZrTe 2

The excitonic insulator (EI) is a Bose-Einstein condensation (BEC) of excitons bound by electron-hole interaction in a solid, which could support high-temperature BEC transition. The material realization of EI has been challenged by the difficulty of distinguishing it from a conventional charge density wave (CDW) state. In the BEC limit, the preformed exciton gas phase is a hallmark to distinguish EI from conventional CDW, yet direct experimental evidence has been lacking. Here we report a distinct correlated phase beyond the 2×2 CDW ground state emerging in monolayer 1T-ZrTe 2 and its investigation by angle-resolved photoemission spectroscopy (ARPES) and scanning tunneling microscopy (STM). The results show novel band- and energy-dependent folding behavior in a two-step process, which is the signatures of an exciton gas phase prior to its condensation into the final CDW state. Our findings provide a versatile two-dimensional platform that allows tuning of the excitonic effect.

36 MATERIALS SCIENCE↗

Excited quantum anomalous and spin Hall effect: dissociation of flat-bands-enabled excitonic insulator state

Quantum anomalous Hall effect (QAHE) and quantum spin Hall effect (QSHE) are two interesting physical manifestations of 2D materials that have an intrinsic nontrivial band topology. In principle, they are ground-state equilibrium properties characterized by Fermi level lying in a topological gap, below which all the occupied bands are summed to a non-zero topological invariant. In this work, we propose theoretical concepts and models of ‘excited’ QAHE (EQAHE) and EQSHE generated by dissociation of an excitonic insulator (EI) state with complete population inversion (CPI), a unique many-body ground state enabled by two yin-yang flat bands (FBs) of opposite chirality hosted in a diatomic Kagome lattice. The two FBs have a trivial gap in between, i.e. the system is a trivial insulator in the single-particle ground-state, but nontrivial gaps above and below, so that upon photoexcitation the quasi-Fermi levels of both electrons and holes will lie in a nontrivial gap achieved by the CPI-EI state, as demonstrated by exact diagonalization calculations. Then dissociation of singlet and triplet EI state will lead to EQAHE and EQSHE, respectively. Realizations of yin-yang FBs in real materials are also discussed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Collective modes in excitonic insulators: Effects of electron-phonon coupling and signatures in the optical response

Here, we consider a two-band spinless model describing an excitonic insulator (EI) on the two-dimensional square lattice with anisotropic hopping parameters and electron-phonon (el-ph) coupling, inspired by the EI candidate Ta 2 NiSe 5 . We systematically study the nature of the collective excitations in the ordered phase which originates from the interband Coulomb interaction and the el-ph coupling. When the ordered phase is stabilized only by the Coulomb interaction (pure EI phase), its collective response exhibits a massless phase mode in addition to the amplitude mode. We show that in the BEC regime, the signal of the amplitude mode becomes less prominent and that the anisotropy in the phase-mode velocities is reduced. Through coupling to the lattice, the phase mode acquires a mass and the signal of the amplitude mode becomes less prominent. Importantly, the character of the softening mode at the boundary between the normal semiconductor phase and the ordered phase depends on the parameters. In particular, we point out that even for el-ph coupling smaller than the Coulomb interaction, the mode that softens to zero at the boundary can have a phonon character. We also discuss how the collective modes can be observed in the optical conductivity. Furthermore, we study the effects of nonlocal interactions on the collective modes and show the possibility of realizing a coexistence of an in-gap mode and an above-gap mode split off from the single-amplitude mode in the system with local interactions only.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Flat-Band-Enabled Triplet Excitonic Insulator in a Diatomic Kagome Lattice

The excitonic insulator (EI) state is a strongly correlated many-body ground state, arising from an instability in the band structure of narrow-gap semiconductors towards exciton formation. Here we show that the flat valence and conduction bands of a Yin-Yang Kagome lattice, as exemplified in a superatomic graphene lattice, conspire to enable an interesting state of triplet EI, based on first-principles Density Functional Theory (DFT) calculations combined with many-body GW and Bethe-Salpeter Equation (BSE). As an intrinsic property of topological flat bands, highly localized electron and hole wavefunctions significantly reduce the screening and enhance the exchange interaction, leading to an unusually high triplet exciton binding energy (~1.2 eV) exceeding the GW band gap by ~0.2 eV and a huge singlet-triplet splitting of ~0.4 eV. Here, the flat-bands-enabled triplet EI state also points to the possibility of complete population inversion between the two topological flat bands for the realization of excited quantum spin Hall effect. Our findings enrich once again the intriguing physics of flat bands, which has drawn broad interest.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Excitonic Condensate in Flat Valence and Conduction Bands of Opposite Chirality

Excitonic Bose-Einstein condensation (EBEC) has drawn increasing attention recently with the emergence of 2D materials. A general criterion for EBEC, as expected in an excitonic insulator (EI) state, is to have negative exciton formation energies in a semiconductor. Here, using exact diagonalization of a multiexciton Hamiltonian modeled in a diatomic kagome lattice, we demonstrate that the negative exciton formation energies are only a prerequisite but insufficient condition for realizing an EI. By a comparative study between the cases of both conduction and valence flat bands (FBs) versus that of a parabolic conduction band, we further show that the presence and increased FB contribution to exciton formation provide an attractive avenue to stabilize the excitonic condensate, as confirmed by calculations and analyses of multiexciton energies, wave functions, and reduced density matrices. In conclusion, our results warrant a similar many-exciton analysis for other known and/or new candidates of EIs and demonstrate the FBs of opposite parity as a unique platform for studying exciton physics, paving the way to material realization of spinor BEC and spin superfluidity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Determining Proton Transport in Pseudo Catalyst Layers Using Hydrogen Pump DC and AC Techniques

Optimizing electrode morphology with a more uniform ionomer distribution is key to reducing ohmic losses and increasing electrocatalyst utilization in polymer electrolyte fuel cells (PEFCs). Inherent ionomer conductivity, volume fraction and tortuosity determine effective ionic conductivity. We use hydrogen pump (HP) method to measure effective ionic conductivity of a pseudo catalyst layer (PCL) comprised of Vulcan XC-72 carbon black and 3M 825 EW ionomer with ionomer to carbon (I/C) ratios of 0.6, 1 and 1.4 and relative humidity (RH) range of 50 to 120%. These direct current (DC) experiments are then compared with electrochemical impedance spectroscopy (EIS). Both DC and EIS methods show good agreement, indicating that EIS can be used as an alternative to DC method in HP experiment. Ionic conductivity for PCL with I/C of 1 and 1.4 was found to be about one order of magnitude higher than I/C of 0.6 for most of the RH range. At 90% RH tortuosities for I/C = 1 and 1.4 were close to 1, whereas tortuosity for I/C = 0.6 was 3. With decrease in relative humidity tortuosities increased linearly and at 50% relative humidity a PCL with I/C = 0.6 had the highest tortuosity of 6.1.

25 ENERGY STORAGE↗

Interpreting Ionic Conductivity for Polymer Electrolyte Fuel Cell Catalyst Layers with Electrochemical Impedance Spectroscopy and Transmission Line Modeling

A cathode catalyst layer containing optimally distributed ionomer is critical to reduce the platinum loading and increase its utilization in polymer electrolyte fuel cells. Here, electrochemical impedance spectroscopy (EIS) was used to measure effective ionic conductivity of pseudo catalyst layers (PCLs) at a relative humidity (RH) range of 50%-120%. These results are compared to previous work using the hydrogen pump (HP) method. EIS effective ionic conductivity results reported here are higher than those from the HP because in the HP set-up ionic pathways must be effectively connected through the PCL to be counted, whereas in the EIS measurement, ionomer segments that are in contact with the membrane but are not effectively connected all the way through the PCL can be detected. Double layer capacitances and effective ionic conductivities of Pt/C catalyst layers with various supports and ionomer to carbon (I/C) ratios were studied. High surface area carbon support resulted in a lower effective ionic conductivity compared to the graphitized carbon support due to worse ionomer dispersion. Effective ionic conductivities of Pt/C layers were compared to that of PCLs. On average, effective ionic conductivities of Pt/C layers were higher than PCLs because of possible carbon agglomeratio n within the PCLs.

25 ENERGY STORAGE↗

Machine Learning Benchmarks for the Classification of Equivalent Circuit Models from Electrochemical Impedance Spectra

Analysis of Electrochemical Impedance Spectroscopy (EIS) data for electrochemical systems often consists of defining an Equivalent Circuit Model (ECM) using expert knowledge and then optimizing the model parameters to deconvolute various resistance, capacitive, inductive, or diffusion responses. For small data sets, this procedure can be conducted manually; however, it is not feasible to manually define a proper ECM for extensive data sets with a wide range of EIS responses. Automatic identification of an ECM would substantially accelerate the analysis of large sets of EIS data. We showcase machine learning methods to classify the ECMs of 9,300 impedance spectra provided by QuantumScape for the BatteryDEV hackathon. The best-performing approach is a gradient-boosted tree model utilizing a library to automatically generate features, followed by a random forest model using the raw spectral data. A convolutional neural network using boolean images of Nyquist representations is presented as an alternative, although it achieves a lower accuracy. We publish the data and open source the associated code. The approaches described in this article can serve as benchmarks for further studies. A key remaining challenge is the identifiability of the labels, underlined by the model performances and the comparison of misclassified spectra.

25 ENERGY STORAGE↗

Early Detection of Li-Ion Battery Thermal Runaway Using Commercial Diagnostic Technologies

The rate of electric vehicle (EV) adoption, powered by the Li-ion battery, has grown exponentially; largely driven by technological advancements, consumer demand, and global initiatives to reduce carbon emissions. As a result, it is imperative to understand the state of stability (SoS) of the cells inside an EV battery pack. That understanding will enable the warning of or prevention against catastrophic failures that can lead to serious injury or even, loss of life. The present work explores rapid electrochemical impedance spectroscopy (EIS) coupled with gas sensing technology as diagnostics to monitor cells and packs for failure markers. These failure markers can then be used for onboard assessment of SoS. Experimental results explore key changes in single cells and packs undergoing thermal or electrical abuse. Rapid EIS showed longer warning times, followed by VOC sensors, and then H 2 sensors. While rapid EIS gives the longest warning time, with the failure marker often appearing before the cell vents, the reliability of identifying impedance changes in single cells within a pack decreases as the pack complexity increases. This provides empirical evidence to support the significant role that cell packaging and battery engineering intricacies play in monitoring the SoS.

25 ENERGY STORAGE↗

Criterion validity of wrist accelerometry for assessing energy intake via the intake-balance technique

Background: Intake-balance assessments measure energy intake (EI) by summing energy expenditure (EE) with concurrent change in energy storage (ΔES). Prior work has not examined the validity of such calculations when EE is estimated via open-source techniques for research-grade accelerometry devices. The purpose of this study was to test the criterion validity of accelerometry-based intake-balance methods for a wrist-worn ActiGraph device. Methods: Healthy adults (n = 24) completed two 14-day measurement periods while wearing an ActiGraph accelerometer on the non-dominant wrist. During each period, criterion values of EI were determined based on ΔES measured by dual X-ray absorptiometry and EE measured by doubly labeled water. A total of 11 prediction methods were tested, 8 derived from the accelerometer and 3 from non-accelerometry methods (e.g., diet recall; included for comparison). Group-level validity was assessed through mean bias, while individual-level validity was assessed through mean absolute error, mean absolute percentage error, and Bland–Altman analysis. Results: Mean bias for the three best accelerometry-based methods ranged from -167 to 124 kcal/day, versus -104 to 134 kcal/day for the non-accelerometry-based methods. The same three accelerometry-based methods had mean absolute error of 323–362 kcal/day and mean absolute percentage error of 18.1-19.3%, versus 353–464 kcal/day and 19.5-24.4% for the non-accelerometry-based methods. All 11 methods demonstrated systematic bias in the Bland–Altman analysis. Conclusions: Accelerometry-based intake-balance methods have promise for advancing EI assessment, but ongoing refinement is necessary. We provide an R package to facilitate implementation and refinement of accelerometry-based methods in future research (see paulhibbing.com/IntakeBalance).

60 APPLIED LIFE SCIENCES↗

Proximal Observations of Epicentral Infrasound Generated by Shallow Low-Magnitude Earthquakes in the Permian Basin, West Texas

Infrasound generated by earthquakes and explosions is generally detected at receivers at epicentral distances of hundreds to thousands of kilometers. However, proximal (<50 km) observations are especially important for low-magnitude earthquakes and low-yield explosions that may not generate signals capable of being detected at great ranges. Here, in this study, we present on the signals detected on an infrasound array 3 km away from two M L 2.9 earthquakes in the Permian Basin of west Texas. Local infrasound (LIS), generated at receivers during the passage of seismic waves, was detected following each earthquake. Epicentral infrasound (EIS), created at or near the epicenter and propagating away as a sound wave, was also detected. Array processing methods show that the EIS signals arrive from the same direction as the earthquake epicenters and at acoustic speeds. To our knowledge, these are the first observations of laterally propagating EIS at proximal ranges following an earthquake of any magnitude.

58 GEOSCIENCES↗

Performance Assessment of Photovoltaic Panels Using Impedance Spectroscopy

The goal of this project was to develop a technique for measuring internal characteristics of a PV module using light modulation under a fixed voltage bias while measuring the resulting alternating current. This technique, light-intensity modulated impedance spectroscopy (LIMIS), has the promise of detecting early signs of panel aging and degradation that could be used for example by solar farm operators to have early warnings to repair or replace panels to maintain reliability of the overall PV array. LIMIS would be complementary with the previously developed electrochemical impedance spectroscopy (EIS), which uses an alternating voltage applied electrically to a solar cell with a similar alternating current measurement. EIS has mostly been developed for individual PV cells rather than whole modules. The project was intended to assess what different information could be revealed by LIMIS, which may in some cases be more scalable to larger modules and potentially more practical to apply in field measurements without needing to electrically disconnect PV modules. We began with small 10 W PV modules and built a testbed capable of oscillating the light intensity with frequencies up to 50 kHz. In parallel, we built a large testbed for testing large 250 W PV modules. Meanwhile, we developed procedures for established measurement techniques: current–voltage (I–V), EIS, and electroluminescence (EL) imaging, where panels are subjected to forward bias while their infrared emission is recorded using a camera modified to be sensitive to IR wavelengths. In addition, we developed protocols for accelerated aging of PV modules in two ways. Thermal cycling from –40°C to +90°C simulates the diurnal temperature cycles on a rooftop. Mechanical stress by dropping a 227 g ball from a height of 1 m simulates damage such as that due to hail impacts.

14 SOLAR ENERGY↗