Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRIC INSULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A brief survey of radiation effects on polymer dielectrics

Future space power needs are extrapolated to be at least three to four orders of magnitude more than is currently available. This long-term reliable power will be required on missions such as the Space Station, Pathfinder, Space Plane, and high-powered satellites, and for defense. Electrical insulation and dielectrics are the key electrical materials needed to support these power systems, where a single-point system failure could prove catastrophic or even fatal for the whole mission. Therefore, the impact of radiation, an environmental stress, on the properties and performance of insulation and dielectrics must be understood. The influence of radiation on polymer dielectrics, the insulating materials most commonly used for power transmission and storage, is reviewed. The effects of the type of radiation, dose, rate, and total exposure on the key electrical, mechanical, and physical properties of polymer dielectrics are described and explained.

Laghari, Javaid R.↗

Industry Scan of Non-SF6 Gas-Insulated Technologies

Sulfur Hexafluoride (SF 6 ) is a specialty gas with excellent electrical insulation properties which has been used extensively in the power industry. This gas is unfortunately also one of the most potent greenhouse gases known to humanity. A 2014 report by the Intergovernmental Panel on Climate Change found that SF 6 has a global warming potential (GWP) 23,000 times higher than Carbon Dioxide, and has the highest GWP of all gases assessed (Myhre 2013). SF 6 is almost exclusively man-made and is produced for use as an insulator in high voltage electrical equipment. This makes the production and use of SF 6 one of the leading sources of anthropogenic climate change. Since SF 6 recognition as a significant contributor to climate change, most governments and organizations have sought ways to reduce or eliminate their use of this gas. Many utilities have initiated leak monitoring and repair programs which have significantly reduced emissions of this gas into the atmosphere. While leak reduction programs have been effective at reducing emission rates in the developed world, leak rates remain frozen at ~1% annually. However, one of the largest and fastest growing markets for this gas is in the developing world where emissions standards are often lacking (P&S Intelligence. 2023). To fully eliminate the environmental impacts of SF 6 , alternative technology is needed. The ideal replacement would be a technology that can fulfil the same role as SF 6 , at the same cost or cheaper, but without adverse environmental effects. Currently, no technology fits this description, however several promising technologies have begun to enter the market. This report was commissioned by the United States Department of Energy’s Office of Electricity under the Transformer Resilience and Advanced Components (TRAC) program to assess the state of industry adoption and manufacturing capability for SF 6 -free alternative technologies for use at the high-voltage level, and the primary barriers to broader adoption. While this report is tailored to the United States, the findings should be relevant to all stakeholders seeking to reduce SF 6 emissions.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Determination of life for a polyimide-epoxy alternator insulation system

Tests were conducted to predict remaining electrical insulation life of a polyimide epoxy insulated 60 KW, 208 volt homopolar inductor alternator, following completion of 23,130 hours of turbo-alternator endurance tests. The sectioned armature winding of this alternator stator was used as means to evaluate and measure end-life at several aging temperatures for development of an Arrhenius plot. A one-half life rate of 11.3 C was established from these data with a predicted remaining life of 60,000 hours at an armature winding temperature of 248 C and a total life, including endurance test time, of 61,645 hours.

Penn, W. B.↗

Scaling Electric Machines to a Megawatt and Material Options

Megawatt (MW) electric aircraft propulsion (EAP) is seen as a significant contributor toward achieving the goals set forth by the Sustainable Flight National Partnership. A large part of enabling MW EAP is developing specific-power-dense electric machines. As specific-power-dense electric machines are scaled up from kW to MW power levels, the thermal stresses on the machines increase in both magnitude and performance-affecting characteristics. This is particularly true for the stators of these machines. Analysis via thermal resistance network modeling and multiscale modeling reveals that increasing amounts of heat will be trapped in the stator windings as the power levels increase. The challenges this presents can be addressed through material advancements whereby materials gain multifunctionality. Specifically, the electrical insulation and potting materials, along with the electrical conductor, that compose the stator slot must work together (gain multifunctionality) to relieve the increased thermal stress. Materials research at the NASA Glenn Research Center points to some useful solutions in this trade space.

Electric Machine↗

Scaling Electric Machines to a Megawatt and Material Options

Megawatt (MW) electric aircraft propulsion (EAP) is seen as a significant contributor toward achieving the goals set forth by the Sustainable Flight National Partnership. A large part of enabling MW EAP is developing specific-power-dense electric machines. As specific-power-dense electric machines are scaled up from kW to MW power levels, the thermal stresses on the machines increase in both magnitude and performance-affecting characteristics. This is particularly true for the stators of these machines. Analysis via thermal resistance network modeling and multiscale modeling reveals that increasing amounts of heat will be trapped in the stator windings as the power levels increase. The challenges this presents can be addressed through material advancements whereby materials gain multifunctionality. Specifically, the electrical insulation and potting materials, along with the electrical conductor, that compose the stator slot must work together (gain multifunctionality) to relieve the increased thermal stress. Materials research at the NASA Glenn Research Center points to some useful solutions in this trade space.

Electric Machine↗

Sialons as high temperature insulators

Sialons were evaluated for application as high temperature electrical insulators in contact with molybdenum and tungsten components in hard vacuum applications. Both D.C. and variable frequency A.C. resistivity data indicate the sialons to have electrical resistivity similar to common oxide in the 1000 C or higher range. Metallographic evaluations indicate good bonding of the type 15R ALN polytype to molybdenum and tungsten. The beta prime or modified silicon nitride phase was unacceptable in terms of vacuum stability. Additives effect on electrical resistivity. Similar resistivity decreases were produced by additions of molybdenum or tungsten to form cermets. The use of hot pressing at 1800 C with ALN, Al2 O3 and Si3N4 starting powders produced a better product than did a combination of SiO2 and AIN staring powders. It was indicated that sialons will be suitable insulators in the 1600K range in contact with molybdenum or tungsten if they are produced as a pure ceramic and subsequently bonded to the metal components at temperatures in the 1600K range.

Phillips, W. M.↗

Method of Fault Detection and Rerouting

A system and method for detecting damage in an electrical wire, including delivering at least one test electrical signal to an outer electrically conductive material in a continuous or non-continuous layer covering an electrically insulative material layer that covers an electrically conductive wire core. Detecting the test electrical signals in the outer conductive material layer to obtain data that is processed to identify damage in the outer electrically conductive material layer.

Medelius, Pedro J.↗

Coaxial anode wire for gas radiation counters

The design and characteristics of a gas radiation counter are discussed. The coaxial anode consists of an elongated central wire covered with an electrically insulating sleeve. Several longitudinally discontinuous segments of an electrically conductive coating are disposed about the insulating sleeve in a coaxial pattern along the length of the central wire. The conductive coating segments form a veto or rejection anode at each end of the central wire and a main or primary charge detecting anode between the ends. The segments are coupled together so that the primary charge detecting anode is connected to detection circuitry in anti-coincidence with the veto anodes. Background radiation detected by either of the veto anodes and the primary charge detecting anode is rejected and the sensitivity of the radiation counter device is increased.

Kraushaar, W. L.↗

NASA-GRC High Voltage Materials Development and Test Capabilities Portfolio

This presentation provides the background information on NASA-GRC high voltage (HV) materials team research efforts towards electrified propulsion systems since 2016 . Additionally, it covers polymer and ceramic filler materials development for HV electrical insulation composites, copper/ carbon nanotube hybrid conductors, modeling efforts, HV test capabilities, and future material processing capabilities.

Boron Nitride↗

Flexible Ceramic-Insulated Cable

Cable withstands heat, radiation, and oxidation. Ceramic beads electrically insulate copper conductor from sheath of copper tape. Also suitable for furnaces, nuclear reactors, and robots operating in hot, radioactive environments.

Bouquet, Frank L.↗

Bubble Formation and Detachment in Reduced Gravity Under the Influence of Electric Fields

The objective of the study is to investigate the behavior of individual air bubbles injected through an orifice into an electrically insulating liquid under the influence of a static electric field. Both uniform and nonuniform electric field configurations were considered. Bubble formation and detachment were recorded and visualized in reduced gravity (corresponding to gravity levels on Mars, on the Moon as well as microgravity) using a high-speed video camera. Bubble volume, dimensions and contact angle at detachment were measured. In addition to the experimental studies, a simple model, predicting bubble characteristics at detachment was developed. The model, based on thermodynamic considerations, accounts for the level of gravity as well as the magnitude of the uniform electric field. Measured data and model predictions show good agreement and indicate that the level of gravity and the electric field magnitude significantly affect bubble shape, volume and dimensions.

Herman, Cila↗

Electric Field Effect on Bubble Detachment in Variable Gravity Environment

The subject of the present study, the process of bubble detachment from an orifice in a plane surface, shows some resemblance to bubble departure in boiling. Because of the high heat transfer coefficients associated with phase change processes, boiling is utilized in many industrial operations and is an attractive solution to cooling problems in aerospace engineering. In terrestrial conditions, buoyancy is responsible for bubble removal from the surface. In space, the gravity level being orders of magnitude smaller than on earth, bubbles formed during boiling remain attached at the surface. As a result, the amount of heat removed from the heated surface can decrease considerably. The use of electric fields is proposed to control bubble behavior and help bubble removal from the surface on which they form. The objective of the study is to investigate the behavior of individual air bubbles injected through an orifice into an electrically insulating liquid under the influence of a static electric field. Bubble cycle life were visualized in terrestrial conditions and for several reduced gravity levels. Bubble volume, dimensions and contact angle at detachment were measured and analyzed for different parameters as gravity level and electric field magnitude. Situations were considered with uniform or non-uni form electric field. Results show that these parameters significantly affect bubble behavior, shape, volume and dimensions.

Iacona, Estelle↗

Bubble Detachment in Variable Gravity Under the Influence of Electric Fields

The objective of the research is to investigate the behavior of individual air bubbles injected through an orifice into an electrically insulating liquid under the influence of a static electric field. Situations were considered with both uniform and nonuniform electric fields. Bubble formation and detachment were visualized in terrestrial gravity as well as for several levels of reduced gravity (lunar, martian and microgravity) using a high-speed video camera. Bubble volume, dimensions and contact angles at detachment were measured. In addition to the experimental studies, a simple model, predicting bubble characteristics at detachment in an initially uniform electric field was developed. The model, based on thermodynamic considerations, accounts for the level of gravity as well as the magnitude of the uniform electric field. The results of the study indicate that the level of gravity and the electric field magnitude significantly affect bubble behavior as well as shape, volume and dimensions.

Herman, Cila↗

Materials for Power Transmission in Extreme Environments

NASA’s goal for a sustained human presence on the Moon and a future Lunar economy requires the development of novel power transmission materials for extreme environments. As an increasing number of public and private entities set their sights towards a future on the Moon, the demand for surface power will dramatically increase – potentially up to megawatt levels. A Lunar economy is envisioned to include a human habitat, manned and unmanned science exploration assets, excavation rovers and systems, and large-scale infrastructure construction such as solar arrays and power grids. A NASA trade study estimated that 1 to 3 km of power transmission lines (1 to 3 KV ac and dc) will be needed over time. Current high power and voltage SOA cables/wire can easily exceed 1 kg/m where mass is not as critical. Connectors, deployment spools and robots further increase the subsystem mass significantly increasing costs. On the other hand, advances in aeronautics provides path towards space missions. The operating environment on the Moon presents substantial risk to safe and reliable power transmission due to space weathering and degradation. These challenges include cosmic and UV radiation, extreme temperatures swings, the electrostatic Lunar exosphere, and the electrostatic and abrasive lunar regolith. The critical need for lightweight, safe and reliable power cables/wires materials is evident. In this presentation, the extreme high altitude and lunar environments and recent materials development from NASA Glenn Research Center’s High Voltage Materials team towards meeting NASA’s objectives and goals for aeronautics and space missions.

Cu/CNT conductors↗