Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRIC NETWORK”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Patternable Mesoporous Thin Film Quantum Materials via Block Copolymer Self-Assembly: An Emergent Technology?

Recent developments in quantum materials hold promise for revolutionizing energy and information technologies. The use of soft matter self-assembly, for example, by employing block copolymers (BCPs) as structure directing or templating agents, offers facile pathways toward quantum metamaterials with highly tunable mesostructures via scalable solution processing. Here, we report the preparation of patternable mesoporous niobium carbonitride-type thin film superconductors through spin-coating of a hybrid solution containing an amphiphilic BCP swollen by niobia sol precursors and subsequent thermal processing in combination with photolithography. Spin-coated as-made BCP-niobia hybrid thin films on silicon substrates after optional photolithographic definition are heated in air to produce a porous oxide, and subsequently converted in a multistep process to carbonitrides via treatment with high temperatures in reactive gases including ammonia. Grazing incidence small-angle X-ray scattering suggests the presence of ordered mesostructures in as-made BCP-niobia films without further annealing, consistent with a distorted alternating gyroid morphology that is retained upon thermal treatments. Wide-angle X-ray scattering confirms the synthesis of phase-pure niobium carbonitride nanocrystals with rock-salt lattices within the mesoscale networks. Electrical transport measurements of unpatterned thin films show initial exponential rise in resistivity characteristic of thermal activation in granular systems down to 12.8 K, at which point resistivity drops to zero into a superconducting state. Magnetoresistance measurements determine the superconducting upper critical field to be over 16 T, demonstrating material quality on par with niobium carbonitrides obtained from traditional solid-state synthesis methods. Here. we discuss how such cost-effective and scalable solution-based quantum materials fabrication approaches may be integrated into existing microelectronics processing, promising the emergence of a technology with tremendous academic and industrial potential by combining the capabilities of soft matter self-assembly with quantum materials.

36 MATERIALS SCIENCE↗

Framework for Supporting Adaptive Droop Based Power Electronic Systems

The electric grid is evolving into an electrical network composed of power electronic converters interconnected with renewable and energy storage technologies. This requires the adoption of more advanced control such as volt/var regulation, fast frequency control, and active power frequency response. This work presents a communication and control framework to support dynamically changing droop control segments that can be used for different optimization schemes. Results are presented to work in a controller hardware in the loop testbed.

Starke, Michael↗

Regional Inertia Estimation Using Actual Event Measurements: Florida Case

As inverter-based resources’ integration in power grids increases, their uneven distribution across the electrical network leads to the formation of local regions that are weakly coupled to the larger interconnection. This signifies the necessity of regional frequency dynamics investigation and analyzing various inertia metrics. This paper presents a practical methodology for estimating regional rate-of-change of frequency (RoCoF) using actual event recordings, which is then used to evaluate regional inertia. Florida (FL) is selected as the region of interest due to its distinct regional frequency dynamics and the rising levels of solar generation. We identify and analyze confirmed events from 2017 to 2024 that occurred in FL. The results indicate that FL contributes about 14% to the total inertia of the US Eastern Interconnection, which approximately matches its share of generation capacity. Results also highlight seasonal fluctuations in energy generation, which play a significant role in influencing inertia and thus the RoCoF levels. This emphasizes the importance of estimating regional inertia to enhance grid operations for a future that focuses on distributed generation.

Dulal, Saurav [University of Tennessee, Knoxville ↗

Solid State Power Substations (SSPS): A Multi-Hierarchical Architecture from Substation to Grid Edge

With the growing deployment of distributed generation, or power electronic interfaced renewable energy and storage technologies, the nature and behavior of the grid is changing. Synchronous machine-driven asset contributions to the generation mix are shrinking, leading to concerns regarding grid stability. Furthermore, the scale of smaller distributed PE resources needed for managing the electrical network could dwarf the existing system leading to more complex optimization problems and communication interconnections. This paper introduces the concept of a hierarchal system of controllers that spans the grid edge or the customer end to distribution scale substations or solid-state power substation (SSPS). This concept focuses on minimizing the number of interfaces and optimization considerations in the grid by clustering resources into nodes and hubs. The work validates the concept in a controller hardware-in-the-loop (cHIL) platform.

Chinthavali, Madhu Sudhan↗

Seamless Transition of Critical Infrastructures using Droop Controlled Grid-forming Inverters

Seamless recovery of power to critical infrastructures, after grid failure, is a crucial need arising in scenarios that are increasingly becoming more frequent. Here, this article proposes a seamless transition strategy using a single and unified mode-dependent droop controlled grid-forming inverters. The control strategy achieves the following objectives: 1) regulates the output active and reactive power by the droop-controlled inverters to a desired value while operating in on-grid mode; 2) seamless transition and recovery of power injections into the load after grid failure by inverters that operates in grid-forming mode all the time; 3) requires only a single bit of information on the grid/network status for the mode transition. A framework for assessing the stability of the system and to guide the choice of parameters for controllers is developed using control-oriented modeling. A controller hardware-in-the-loop-based real-time simulation study on a test system based on the realistic electrical network of a commercial-scale medical center is conducted for initial prototyping of the control strategy. A hardware experiment is conducted with two 3 - $\phi$, 480 -V, 125 -kVA grid-forming inverters, a 3 - $\phi$, 480 -V, 270 -kVA grid simulator, a physical grid switch, and a physical load bank. The experimental data establishes the effectiveness of the always grid-forming operation and control of inverters in meeting power delivery objectives when on-grid and off-grid under various kinds of loads and scenarios while minimizing transients during transitions. Furthermore, performance comparison with existing strategies showcases the advantage of the proposed strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid-tied Multilevel Inverter with Phase-locked Loop Algorithm

A multilevel inverter is an electronic device capable of changing direct current energy to alternant current energy with a voltage and frequency established by the user. They are ideal for connecting renewable energy sources to the AC grid, energy plants, and smart grids. The voltage must be balanced and synchronized with the electrical network for adequate performance. This paper shows the voltage synchronization between an inverter output voltage and the AC grid using a phase-locked loop based on an adaptive observer. The proposed algorithm can perform under grid uncertainties such as noise and generates a reference signal for the modulation used in the inverter. The algorithm is robust and computationally efficient and can be implemented through basic elements such as operational amplifiers, resistors, and capacitors, reducing its difficulty in executing it in a system.

42 ENGINEERING↗

Keyless Infrastructure Security Solution (KISS): VOLTTRON™ KSI ® Blockchain Design and Specification

This document provides the technical design specifications that are required for Keyless Infrastructure Security Solution (KISS) development, including, definitions and roles of the new KISS-related products—GridAware and LinkLite—an overview of the DNP3 communications the VOLTTRON™ DNP3 agent is using for distribution control, data flow, historian processing, setup, and installation. These technical specifications provide step-by-step instructions for configuration, implementation, and deployment of the KISS subsystem, docket creation, and verification using the GridAware dashboard. Based on this document and the KISS specification requirements and device risk assessment documents, KISS will be developed by integrating keyless signature infrastructure (KSI) blockchain to increase the cybersecurity, integrity, and trustworthiness of critical energy delivery systems (EDSs). The KISS architecture consists of a VOLTTRON™ agent-based distribution control system platform and GridAware (KSI blockchain capability) for secure energy exchanges in a decentralized electrical network.

42 ENGINEERING↗

Enabling Data Exchange and Data Integration with the Common Information Model: An Introduction for Power Systems Engineers and Application Developers

The Common Information Model (CIM) is an open-source information model that is used to model an electrical network and the various equipment used on the network. CIM is widely used for data exchange of bulk transmission power systems and is finding increasing use for distribution systems. Use of a non-proprietary information model (such as CIM) that has been agreed upon and adopted by numerous utilities, vendors, and researchers allows significant reduction in the effort and cost of data integration. Likewise, adoption of open data platforms built around the CIM increases available functionalities for managing and optimizing the smart grid of the future. This report is intended as an introduction to CIM for utility engineers, power systems researchers, and application developers, providing a broad view of the CIM and how particular profiles can be adapted for various use cases. Unlike most other CIM introduction documents and the International Electrotechnical Commission (IEC) standards (which are mostly targeted to an audience of data scientists, enterprise database managers, and platform developers), this report is intended for users of traditional power systems analysis software and other readers without any prior experience with canonical information models, data profiles, or UML modeling.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Method for Coupled Electromagnetic and Circuit Simulations to Evaluate Surge Arrester Performance in Protecting Equipment Against E1 HEMP

Surge arrester behavioral modeling for realistic systems embedded in an E1 high-altitude electromagnetic pulse environment inherently encompasses three interconnected complications: (1) the need to account for signal propagation across two domains, electromagnetics and electrical; (2) the need to include both linear and nonlinear circuit components in the analysis; and (3) the need to understand that the over-current and over-voltage mitigation performance is dependent not only on the properties of the surge arrester and protected load but also on the topology of the overall electrical network. This study presents a framework to address these challenges in a systematic manner to consider the effectiveness of protective measures for a common class of equipment in power generation facilities. Full-wave simulations were carried out to derive circuit-domain (i.e., lumped element–based) equivalent models for the excitation waveform and the physical components of the system. Then, these equivalent models were imported to a circuit solver and combined with a high-frequency surge arrester model to evaluate mitigation performance. The methodology outlined is general enough such that it can be applied for other electromagnetic interference problems that involve E2/E3 HEMP or microwave emissions.

42 ENGINEERING↗

Methodology to Implement a Microgrid in a University Campus

This paper presents the method we followed to design a microgrid at a university campus based on available resources. Due to introduction of renewable resources to produce energy, a methodology that allows design a microgrid in a university campus is very useful. Hence, we present a series of steps that must be carried out to estimate the resource to be used, the installation, area needed, and the capacity of the systems needed are also described. In addition, the models of the distributed resources that constitutes the microgrid are presented and explained. To validate the proposed methodology, simulations were performed using Opal-RT-LAb. As a test scenario we selected the Mayagüez campus of the University of Puerto Rico where we conducted analysis of the available resource and capacity of the systems is needed to satisfy demand of critical loads, considering a predetermined number of days of austerity. Our study results in determination of dimensions, cost and effectiveness of the microgrid. Simulations results also show that the proposed microgrid satisfy demand with the same reliability, or better, than the traditional electrical network. Additionally, the best options for this purpose are photovoltaic, batteries, and combined heat and power, if the technological advances and availability of resources to the date for Puerto Rico are considered.

36 MATERIALS SCIENCE↗

Techno-Economic Modelling of Tidal Energy Converter Arrays in the Tacoma Narrows

Hydrokinetic tidal energy converter (TEC) technology is yet to become cost competitive with other renewable energy sources. Understanding the interaction between energy production and the costs incurred harvesting that energy may unlock the economic potential of this technology. Although hydrodynamic simulation of TEC arrays has matured over time, including demonstration of how small and large arrays affect the resource, integration of cost modelling is often limited. The advanced ocean energy array techno-economic modelling tool ‘DTOcean’ enables designers to calculate and improve the levelised cost of energy (LCOE) of an array through parametric simulation of the energy extraction, design of the electrical network, moorings and foundations, and simulation of the installation and lifetime operations and maintenance of the array. This work presents a verification of DTOcean’s ability to simulate the techno-economic performance of TEC arrays by reproducing the hypothetical RM1 reference model, a semi-analytical model of a TEC array based in the Tacoma Narrows of Washington state, U.S.A. It is demonstrated that DTOcean can produce a reasonable estimate to the LCOE predicted by the reference model, giving (in Euro cents per kiloWatt hour) 36.69 ¢/kWh against the reference model’s 34.612 ¢/kWh for 10 TECs, while for 50 TECs, DTOcean calculated 20.34 ¢/kWh compared to 17.34 ¢/kWh for the reference model.

Topper, Mathew B. R. (ORCID:0000000347324347)↗

Two-axis leveling detector system

Electro-mechanical device for measuring tilt angles in order to establish level base without optical reference is described. Angular displacement is detected by movement of bubble in conducting fluid containing electrode network. Electrical signal causes compensation for small movements in horizontal and vertical planes.

Weiner, L.↗