Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRONIC AMPLIFIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Waveguide Power-Amplifier Module for 80 to 150 GHz

A waveguide power-amplifier module capable of operating over the frequency range from 80 to 150 GHz has been constructed. The module comprises a previously reported power amplifier packaged in a waveguide housing that is compatible with WR-8 waveguides. (WR- 8 is a standard waveguide size for the nominal frequency range from 90 to 140 GHz.) The waveguide power-amplifier module is robust and can be bolted to test equipment and to other electronic circuits with which the amplifier must be connected for normal operation.

Samoska, Lorene↗

Secondary electron yields of solar system ices

The secondary electron yields of H2O, CO2, NH3, and CH3OH ices have been measured as a function of electron beam energy in the 2- to 30-keV energy range. The ices were produced on a liquid-nitrogen-cooled cold finger and transferred under vacuum to a SEM where the yield measurements were made. The imaging capabilities of the SEM provide a means of correlating the yield measurements with the morphology of the ices and are also used to monitor charging effects. The yields were determined by measuring the amplified current from a secondary electron detector and calibrating this current signal with the amplified current signal from samples of metals with known secondary electron yields. Each of the measured yields is found to decrease with an increase in energy in the 2- to 30-keV range. Estimates are given for the maximum secondary electron yield Y(max) of each ice and the energy at which this maximum yield occurs. Implications for the charging of solar system ice grains are discussed.

Suszcynsky, David M.↗

Medium power amplifiers covering 90 - 130 GHz for telescope local oscillators

This paper describes a set of power amplifier (PA) modules containing InP High Electron Mobility Transistor (HEMT) Monolithic Millimeter-wave Integrated Circuit (MMIC) chips. The chips were designed and optimized for local oscillator sources in the 90-130 GHz band for the Atacama Large Millimeter Array telescope. The modules feature 20-45 mW of output power, to date the highest power from solid state HEMT MMIC modules above 110 GHz.

coplanar waveguides↗

Phased Array Radiometer Calibration Using a Radiated Noise Source

Electronic beam steering capability of phased array antenna systems offer significant advantages when used in real aperture imaging radiometers. The sensitivity of such systems is limited by the ability to accurately calibrate variations in the antenna circuit characteristics. Passive antenna systems, which require mechanical rotation to scan the beam, have stable characteristics and the noise figure of the antenna can be characterized with knowledge of its physical temperature [1],[2]. Phased array antenna systems provide the ability to electronically steer the beam in any desired direction. Such antennas make use of active components (amplifiers, phase shifters) to provide electronic scanning capability while maintaining a low antenna noise figure. The gain fluctuations in the active components can be significant, resulting in substantial calibration difficulties [3]. In this paper, we introduce two novel calibration techniques that provide an end-to-end calibration of a real-aperture, phased array radiometer system. Empirical data will be shown to illustrate the performance of both methods.

Srinivasan, Karthik↗

Development of an End-to-End Demonstration Readout Chain for Athena-X-IFU

The X-IFU (X-ray Integral Field Unit) of the Athena (Advanced Telescope for High-ENergy Astrophysics) telescope, scheduled for launch in the early 2030's, will provide X-ray spectroscopy data with unprecedented spectral and spatial resolution. This will be achieved by a 3 kilo-pixel array of TES (transition-edge sensor) microcalorimeters. The complete detection chain is under development by a large international collaboration. The detector array will be provided by NASA Goddard Space Flight Center, the cold TDM (time domain multiplexing) electronics by NIST, the cold amplifier by VTT, the cold focal-plane assembly by SRON, the warm front-end electronics by APC, and the DRE (digital readout electronics) by IRAP. In order to perform an end-to-end demonstration of the X-IFU readout chain, a 50 mK test bench is being developed at IRAP in collaboration with CNES. The test bench is based on a two-stage ADR cryostat from Entropy GmbH and a 1024-pixel array from Goddard associated with its cold TDM readout from NIST. The setup will initially be validated using a warm electronic chain from NIST and Goddard. We will describe the complete system being installed in the cryostat and the first results obtained with these electronics. We will also review the status of the integration of the DRE prototype in the demonstration chain and the way forward in the integration and testing of the complete X-IFU readout chain.

S Beaumont↗

A simulation framework for evaluating electronic order workflows in integrated health records

Electronic health record (EHR) systems are critical to modern healthcare delivery, yet the dynamic workflows that govern electronic order processing remain underexplored. Inefficiencies in these digital pathways can cause delays in care, repetitive workloads, and even patient harm. This study presents a discrete-event simulation framework used to reconstruct and evaluate EHR-based order workflows in a large integrated healthcare system. Using real-world data extracted from the Veterans Health Administration’s Corporate Data Warehouse, the authors mapped order events to standardized state transitions and modeled their progression across different facilities of varying complexity levels. After being calibrated with empirical distributions of transition times and validated against observed time-in-system metrics, the simulation demonstrates close alignment with historical performance. Scenario analyses reveal that resource capacity constraints significantly amplify the impact of electronic order surges, which are reflected in the disproportionate growth in backlogs and processing delays. Adjustments in transition probabilities further increased recirculation and extended workflow paths. Network-based analysis identified Reserved, InProgress, and Completed as structurally critical states that function as hubs within the process network but the transitions in-between also act as major bottlenecks. These results showcased the effectiveness of simulation-based approaches in monitoring EHR order processing performance and evaluating consequences of workflow changes on healthcare network resources planning. The proposed simulation framework provides a scalable data-driven tool to support operational decision-making and improve the efficiency of electronic order management in complex healthcare environments.

Engineering↗

Constant-amplitude, frequency- independent phase shifter

Electronic circuit using operational amplifiers provides output with constant phase shift amplitude, with respect to sinusoidal input, over wide range of frequencies. New circuit includes field effect transistor, Q, operational amplifiers, A1 and A2, and phase detector.

Deboo, G. J.↗

A gamma ray monitor for the OSO-7 spacecraft.

A NaI(T2) gamma ray spectrometer with a CsI(Na) charged particle and anti-Compton shield has been developed for the spacecraft. The spacecraft telemetry system employs a 800 Hz clock and reads data out on a basic 32-word (byte) Main Frame cycle. The data from the instrument include spectral data, X-ray data, and housekeeping data. The gamma ray pulses from the anode of the central detector flow through the front end electronics, where they are amplified by a charge sensitive preamplifier. The admission of the desired gamma ray into the data stream is controlled by a linear gate.

Higbie, P. R.↗

Laboratory measurement of the S(9) pure rotation frequency in H2

The S(9) J = 11-9 ground-state transition in H2 is investigated experimentally, applying a 514.5-nm 300-mW single-mode CW Ar-ion laser to probe the stimulated Raman emission of a CH4-air flame pumped by a single-frequency electronically scannable dye laser amplified to 2 MW by a 10-Hz frequency-doubled Nd:YAG laser. An H2 Raman spectrum with an S(9) frequency of 2130.102 + or - 0.004/cm is shown, and the results are found to be consistent with the measurements obtained in the Orion molecular cloud by Knacke and Young (1980 and 1981).

Jennings, D. E.↗

Low-noise cryogenic transmission line

New low-noise cryogenic input transmission lines have been developed for the Deep Space Network (DSN) at 1.668 GHz for cryogenically cooled Field Effect Transistors (FET) and High Electron Mobility Transistor (HEMT) amplifiers. These amplifiers exhibit very low noise temperatures of 5 K to 15 K, making the requirements for a low-noise input transmission line critical. Noise contribution to the total amplifier system from the low-noise line is less than 0.5 K for both the 1.668-GHz and 2.25-GHz FET systems. The 1.668-GHz input line was installed in six FET systems which were implemented in the DSN for the Venus Balloon Experiment. The 2.25-GHz input line has been implemented in three FET systems for the DSN 34-m HEF antennas, and the design is currently being considered for use at higher frequencies.

Norris, D.↗

Cosmic background radiation anisotropy at degree angular scales - Further results from the South Pole

We report further results from the University of California at Santa Barbara program to measure anisotropy in the cosmic background radiation at angular scales near 1 deg, an angular range corresponding to the largest scales where structure is observed. A 30 GHz high electron mobility transistor amplifier-based detector was coupled to the Advanced Cosmic Microwave Explorer, a 1 m off-axis Gregorian telescope. We present data that represent 64 of the total of 500 hr acquired with this system during the 1990-1991 season. The data have a statistical error of 13.5/micro-K/pixel. These are the smallest error bars of any data set of this type published to date. The data contain a significant signal with a maximum likelihood Delta T/T roughly 1 x 10 exp -5. The spectrum of the signal seen in slightly less than 2 sigma away from the thermal spectrum expected of primordial fluctuations in the cosmic background radiation. If the source of the fluctuations is primordial, then the data are consistent with cold dark matter scenarios when normalized to the large-scale anisotropy observed by COBE, while if the origin of the signal is foreground emission or another form of contaminant then the data are marginally inconsistent with standard cold dark matter models. In either case, the data are sufficiently sensitive to provide a crucial test of many models.

Schuster, Jeffrey↗

Challenging Implementation and Operations Traditions

The Deep Space Network (DSN) that provides for the communications link between the deep space missions and the science users currently consists of a small set of very large monolithic tracking antennas. This ground-based network includes a total of 12 antennas located in three roughly equidistant longitudes around the earth and utilizes a decentralized approach to it operations. Recently, however, studies have suggested that the number, complexity, and data throughput of the future set of space probes will be increasing dramatically. This demands more performance from the DSN than is currently available. In identifying the architecture for the future DSN required to support this mission set, one concept that proves promising is one that consists of a great many number of much smaller antennas configured in an array. This concept has been supported by the developments in antenna manufacturing technology and the consistent decrease in the cost of electronics required to receive, amplify, and combine signals from deep space probes. Furthermore, it is clear that past developments in the DSN have not benefited from the applications of economies of scale.

ANTENNA ARRAYS↗

High-Precision Shape Control of In-Space Deployable Large Membrane/Thin-Shell Reflectors

This innovation has been developed to improve the resolutions of future spacebased active and passive microwave antennas for earth-science remote sensing missions by maintaining surface figure precisions of large membrane/thin-shell reflectors during orbiting. The intention is for these sensing instruments to be deployable at orbit altitudes one or two orders of magnitude higher than Low Earth Orbit (LEO), but still being able to acquire measurements at spatial resolution and sensitivity similar to those of LEO. Because active and passive microwave remote sensors are able to penetrate through clouds to acquire vertical profile measurements of geophysical parameters, it is desirable to elevate them to the higher orbits to obtain orbital geometries that offer large spatial coverage and more frequent observations. This capability is essential for monitoring and for detailed understanding of the life cycles of natural hazards, such as hurricanes, tropical storms, flash floods, and tsunamis. Major components of this high-precision antenna-surface-control system include a membrane/thin shell reflector, a metrology sensor, a controller, actuators, and corresponding power amplifier and signal conditioning electronics (see figure). Actuators are attached to the back of the reflector to produce contraction/ expansion forces to adjust the shape of the thin-material reflector. The wavefront-sensing metrology system continuously measures the surface figure of the reflector, converts the surface figure to digital data and feeds the data to the controller. The controller determines the control parameters and generates commands to the actuator system. The flexible, piezoelectric polymer actuators are thus activated, providing the control forces needed to correct any distortions that exist in the reflector surface. Piezoelectric polymer actuators are very thin and flexible. They can be implemented on the back of the membrane/thin-shell reflector without introducing significant amounts of mass or stiffness to the reflector. They can be rolled up or folded to accommodate the packaging needed for launch. An analytical model of the system, which includes the membrane reflector, actuator, and controller has been developed to investigate the functionality of this control system on a 35-meter-diameter membrane reflector. The performance of this system under external disturbances such as in space thermal loads and W-error due to inflation has been investigated. A subscale breadboard has been developed, and the functionality of this control concept has been demonstrated by this breadboard.

Watkins, Ronald↗

Particle propagation effects on wave growth in a solar flux tube

The evolution of a distribution of electrons is followed after they are injected impulsively at the top of a coronal magnetic loop, with the objective of studying the plasma instabilities which result. At early times the downgoing electrons have beamlike distributions and amplify electrostatic waves via the Cerenkov resonance; the anomalous Doppler resonance is found to be less important. Slightly later, while the electrons are still predominantly downgoing, they are unstable to cyclotron maser generation of z-mode waves with omega(p) much less than Omega, or to second harmonic x-mode waves. The energetics of these instabilities, including saturation effects and heating of the ambient plasma, are discussed. It is suggested that coalescence of two z-mode waves generated by cyclotron maser emission of the downgoing electrons may produce the observed microwave spike bursts.

White, S. M.↗

Cooled Low-Noise HEMT Microwave Amplifiers

Prototype cooled low-noise microwave amplifiers based on high-electron-mobility transistors (HEMT's) considered as replacements for cooled ruby masers used as low-noise receiver-front-end amplifiers in communications, radio science, radar systems, radio astronomy, and telemetry. HEMT amplifier operates at 12 K, requires less cooling power and operates at lower cost with simpler, more-reliable cooling system.

Bautista, J. Javier↗

Refocusing of the spent axisymmetric beam in klystron tubes

Analytic methods were developed and employed to optimize the magnetic field transition region between the output interaction gap of a klystron and a multi-stage depressed potential electrostatic beam collector, in order to enhance the power conversion efficiency of satellite-borne broadcast transmitters. Permanent magnet structures were designed to provide the magnetic field distributions required to expand and recollimate the spent electron beam of the power amplifier klystron for proper entry into the beam collector. These design criteria for magnetic field distributions for expanding and recollimating spent-beam electrons for optimal entry into a multi-stage depressed potential collector are generally applicable to traveling-wave tubes as well as klystrons.

Branch, G. M.↗

Simple photometer circuits using modular electronic components

Operational and peak holding amplifiers are discussed as useful circuits for bioluminescence assays. Circuit diagrams are provided. While analog methods can give a good integration on short time scales, digital methods were found best for long term integration in bioluminescence assays. Power supplies, a general photometer circuit with ratio capability, and variations in the basic photometer design are also considered.

Wampler, J. E.↗