Search NASA⌕ Search

SEARCH · Search NASA

Results for “ENERGY MODELING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Current observational constraints to the holographic dark energy model with a new infrared cutoff via the Markov chain Monte Carlo method

In this paper, the holographic dark energy models with the new infrared cutoff for both the flat case and the nonflat case are confronted with the combined constraints of current cosmological observations: type Ia supernovae, baryon acoustic oscillations, current cosmic microwave background, and the observational Hubble data. By utilizing the Markov chain Monte Carlo method, we obtain the best fit values of the parameters with 1{sigma}, 2{sigma} errors in the flat model: {Omega}{sub b}h{sup 2}=0.0230{sub -0.0010-0.0014}{sup +0.0008+0.0012}, {alpha}=0.9788{sub -0.0927-0.1249}{sup +0.1297+0.1354}, {beta}=0.4739{sub -0.0723-0.0984}{sup +0.0793+0.1055}, {Omega}{sub de0}=0.7869{sub -0.0304-0.0455}{sup +0.0291+0.0370}, {Omega}{sub m0}=0.2131{sub -0.0291-0.0370}{sup +0.0304+0.0455}, H{sub 0}=70.46{sub -2.97-4.02}{sup +2.82+3.89}. In the nonflat model, the constraint results are found in 1{sigma}, 2{sigma} regions: {Omega}{sub b}h{sup 2}=0.0229{sub -0.0010-0.0014}{sup +0.0010+0.0013}, {Omega}{sub k}=0.0014{sub -0.0597-0.0743}{sup +0.0604+0.0604}, {alpha}=0.9637{sub -0.2840-0.3333}{sup +0.2291+0.2894}, {beta}=0.4712{sub -0.0756-0.0961}{sup +0.1412+0.1703}, {Omega}{sub de0}=0.7829{sub -0.2130-0.2386}{sup +0.1588+0.1901}, {Omega}{sub m0}=0.2157{sub -0.1012-0.1241}{sup +0.1562+0.1800}, H{sub 0}=70.64{sub -3.32-4.45}{sup +2.74+3.52}. In the best fit holographic dark energy models, the equation of state of dark energy and the deceleration parameter at present are characterized by w{sub de0}=-0.9278{+-}0.0626, q{sub 0}=-0.5951{+-}0.0586 (flat case) and w{sub de0}=-0.9501{+-}0.1442, q{sub 0}=-0.6164{+-}0.0805 (nonflat case). Compared to the {Lambda}CDM model, it is found the current combined data sets do not favor the holographic dark energy model over the {Lambda}CDM model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Economic assessment and energy model scenarios of municipal solid waste incineration and gas turbine hybrid dual-fueled cycles in Thailand

Finding environmentally benign methods related to sound municipal solid waste (MSW) management is of highest priority in Southeast Asia. It is very important to study new approaches which can reduce waste generation and simultaneously enhance energy recovery. One concrete example of particular significance is the concept of hybrid dual-fuel power plants featuring MSW and another high-quality fuel like natural gas. The hybrid dual-fuel cycles provide significantly higher electrical efficiencies than a composite of separate single-fuel power plant (standalone gas turbine combined cycle and MSW incineration). Although hybrid versions are of great importance for energy conversion from MSW, an economic assessment of these systems must be addressed for a realistic appraisal of these technologies. This paper aims to further examine an economic assessment and energy model analysis of different conversion technologies. Energy models are developed to further refine the expected potential of MSW incineration with regards to energy recovery and environmental issues. Results show that MSW incineration can play role for greenhouse gas reduction, energy recovery and waste management. In Bangkok, the electric power production via conventional incineration and hybrid power plants can cover 2.5% and 8% of total electricity consumption, respectively. The hybrid power plants have a relative short payback period (5 years) and can further reduce the CO{sub 2} levels by 3% in comparison with current thermal power plants.

54 ENVIRONMENTAL SCIENCES↗

DEPRECATED: Campus Energy Model for Control and Performance Validation [SWR-15-13]

DEPRECATED: https://github.com/NatLabRockies/CampusEnergyModeling The core of the modeling platform is an extensible block library for the MATLAB/Simulink software suite. The platform enables true co-simulation (interaction at each simulation time step) with NREL's state-of-the-art modeling tools and other energy modeling software.

Ball, Brian↗

Campus Energy Model for Control and Performance Validation

The core of the modeling platform is an extensible block library for the MATLAB/Simulink software suite. The platform enables true co-simulation (interaction at each simulation time step) with NREL's state-of-the-art modeling tools and other energy modeling software.

Source record↗

Innovations in Building Energy Modeling: Research and Development Opportunities for Emerging Technologies

Building energy modeling (BEM) is a multipurpose tool for building energy efficiency (EE). The U.S. Department of Energy Building Technologies Office (BTO) seeks to expand the use and effectiveness of BEM in the design and operation of commercial and residential buildings with the goal of achieving lasting reductions in total and peak energy use. This report identifies gaps and outlines recommended initiatives to achieve this goal, based on a combination of technical analysis and stakeholder input. In addition to BTO, this report can benefit BEM professionals (architects, mechanical engineers, energy consultants, building auditors, equipment manufacturers, and BEM software vendors) and BEM clients (building owners and operators, EE program administrators, EE service providers, policymakers, and policy and code jurisdictions such as states and cities). This report was developed in two phases. In the first, BTO worked with a team from Navigant Consulting (now Guidehouse) to characterize objectives, opportunities, and current activities; identify gaps and barriers; and define initiatives. To collect input, Navigant conducted telephone interviews and workshops with industry experts. The initial phase produced a draft report, which was released for public review in 2016 and yielded over 400 comments. Based on these comments, BTO compiled a second draft report that addressed many of those comments while acknowledging changes that had occurred both at BTO and in the industry. Unlike the first draft report, the second focused much more heavily on BTO’s own role, portfolio, and activities. BTO is a direct player in the BEM field - it funds the development of several significant software packages that are embedded in commercial products - and transparency about its goals and future plans is requisite. BTO recognizes that a great number of other public and private organizations contribute to the BEM enterprise. With the second draft report, BTO did not attempt to produce a blueprint for the industry as a whole, but rather a working document BTO can use to iteratively solicit stakeholder input and synthesize it into a program. BTO released the second draft report for public review in 2019. The second round of review generated 83 pages of feedback and comments - almost exactly the length of the draft report itself - a significant portion of which was collected and synthesized by IBPSA-USA Advocacy Committee. This final report incorporates this feedback. This report does not address the use of BEM in support of building-based grid services, a recent BTO initiative called Grid-interactive Efficient Buildings (GEB). In 2019, BTO published a report that specifically addresses the role of BEM - and other “integration” technologies - in GEB.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Possible equilibria of interacting dark energy models

Interacting dark energy and the holographic principle offer a possible way of addressing the cosmic coincidence problem as well as accounting for the size of the dark energy component. The equilibrium points of the Friedmann equations which govern the evolution behavior of dark energy, matter, and curvature components can determine the qualitative behavior of the cosmological models. These possible equilibria and their behavior are examined in a general framework, and some illustrative examples are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Empirical Validation of Building Energy Modeling using Flexible Research Platform

Recently, efforts have been made to provide reliable empirical data for ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs, to enable improved accuracy of building energy model (BEM) engines and improved characterization of their accuracy. The motivation for this effort is that the use of reliable empirical validation data sets in the evaluation of building energy modeling tools will lead to more consistent and validated simulation engines across all software vendors. This would expedite the use of building energy modeling in designing new buildings and retrofitting existing buildings, which delivers more energy efficient buildings.As part of a three-year multi-lab empirical validation project sponsored by U.S. DOE, this research project generated cooling season test plans by reviewing ASHRAE Standard 140, and the tests were performed based on the test plan. Finally, the experimental data sets were compared with the EnergyPlus model to demonstrate the validation procedure.

Im, Piljae↗

Observational constraints to Ricci dark energy model by using: SN, BAO, OHD, fgas data sets

We perform a global constraint on the Ricci dark energy model with both the flat case and the non-flat case, using the Markov Chain Monte Carlo (MCMC) method and the combined observational data from the cluster X-ray gas mass fraction, Supernovae of type Ia (397), baryon acoustic oscillations, current Cosmic Microwave Background, and the observational Hubble function. In the flat model, we obtain the best fit values of the parameters in 1σ,2σ regions: Ω{sub m0} = 0.2927{sup +0.0420+0.0542}{sub −0.0323−0.0388}, α = 0.3823{sup +0.0331+0.0415}{sub −0.0418−0.0541}, Age/Gyr = 13.48{sup +0.13+0.17}{sub −0.16−0.21}, H{sub 0} = 69.09{sup +2.56+3.09}{sub −2.37−3.39}. In the non-flat model, the best fit parameters are found in 1σ,2σ regions:Ω{sub m0} = 0.3003{sup +0.0367+0.0429}{sub −0.0371−0.0423}, α = 0.3845{sup +0.0386+0.0521}{sub −0.0474−0.0523}, Ω{sub k} = 0.0240{sup +0.0109+0.0133}{sub −0.0130−0.0153}, Age/Gyr = 12.54{sup +0.51+0.65}{sub −0.37−0.49}, H{sub 0} = 72.89{sup +3.31+3.88}{sub −3.05−3.72}. Compared to the constraint results in the ΛCDM model by using the same datasets, it is shown that the current combined datasets prefer the ΛCDM model to the Ricci dark energy model.

79 ASTRONOMY AND ASTROPHYSICS↗

Observational constraints on the interacting Ricci dark energy model

We consider an extension of the holographic Ricci dark energy model by introducing an interaction between dark energy and matter. In this model, the dark energy density is given by {rho}{sub {Lambda}=}-(1/2){alpha}M{sub p}{sup 2}R, where R is the Ricci scalar curvature, M{sub p} is the reduced Planck mass, and {alpha} is a dimensionless parameter. The interaction rate is given by Q={gamma}H{rho}{sub {Lambda},} where H is the Hubble expansion rate, and {gamma} is a dimensionless parameter. We investigate current observational constraints on this model by applying the type Ia supernovae, the baryon acoustic oscillation and the cosmic microwave background anisotropy data. It is shown that a nonvanishing interaction rate is favored by the observations. The best fit values are {alpha}=0.45{+-}0.03 and {gamma}=0.15{+-}0.03 for the present dark energy density parameter {Omega}{sub {Lambda}0}=0.73{+-}0.03.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a metamodelling framework for building energy models with application to fifth-generation district heating and cooling networks

Fully defined physics-based building energy models can accurately represent building systems; however, generating models based on high-level parameters is time consuming and simulation time of complex models can be slow. This article discusses the development of a Metamodelling Framework to create metamodels from a building energy modelling dataset. The framework generates metamodels using either linear regression, random forests, or support vector regressions. A fifth-generation district heating and cooling system analysis use case was used to motivate the development of the framework. The use case required quick and accurate representations of annual building loads reported hourly. Typical annual building modelling approaches can result in a runtime of 10 min. The metamodels runtime was reduced to less than 10 s to load and run an annual simulation with user-defined covariates. The results of the metamodel performance and an abbreviated topology analysis based on the motivating use case will be presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pilgrim Hot Springs Building Dimensions and Energy Modeling

This dataset was created to model the anticipated heating load of a geothermal project in development for the historical site of Pilgrim Hot Springs, and adds to the history of geothermal studies at the site. Models include an historical building (Nun's Quarters), existing modern buildings (Caretaker's Cabin, Igloo, Visitor's Cabin, Staff Shower Hut), and planned building projects (Changing Room, Greenhouse). Modeling results were used to determine feasible geothermal system typologies. The previous study linked below ("Village of Solomon Development of Energy Efficiency Building Standards for New Construction") feeds in to this project. The dataset includes DWG drawings and AKwarm energy models (.hm2) of a subset of existing buildings at the site of Pilgrim Hot Springs. All buildings were modeled in their current state, and some were additionally modeled with improvements to the building envelope. Energy modeling results exported from AKwarm include .htm and .png images.

AKwarm↗

Energy Modeling for the Artisan Food Center

The Artisan Food Center is a 6912 sq.ft food processing plant located in Dayton, Washington. PNNL was contacted by Strecker Engineering to assist with the building’s energy analysis as a part of the project’s U.S. Green Building Council’s Leadership in Energy and Environmental Design (LEED) submittal requirements. The project is aiming for LEED Silver certification, one of the prerequisites to which is a whole building energy model to demonstrate compliance with American Society of Heating Refrigeration and Air Conditioning Engineers (ASHRAE) 90.1 2007 Appendix G, Performance Rating Method. The building incorporates a number of energy efficiency measures as part of its design and the energy analysis aimed at providing Strecker Engineering with the know-how of developing an energy model for the project as well as an estimate of energy savings of the proposed design over the baseline design, which could be used to document points in the LEED documentation. This report documents the ASHRAE 90.1 2007 baseline model design, the proposed model design, the modeling assumptions and procedures as well as the energy savings results in order to inform the Strecker Engineering team on a possible whole building energy model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

On dark energy models of single scalar field

In this paper we revisit the dynamical dark energy model building based on single scalar field involving higher derivative terms. By imposing a degenerate condition on the higher derivatives in curved spacetime, one can select the models which are free from the ghost mode and the equation of state is able to cross the cosmological constant boundary smoothly, dynamically violate the null energy condition. Generally the Lagrangian of this type of dark energy models depends on the second derivatives linearly. It behaves like an imperfect fluid, thus its cosmological perturbation theory needs to be generalized. We also study such a model with explicit form of degenerate Lagrangian and show that its equation of state may cross -1 without any instability.

79 ASTRONOMY AND ASTROPHYSICS↗

ReVision Home: Energy Modeling

This fact sheet provides information about specifications and energy modeling results of the ReVision Home in Las Vegas, NV.

CARB↗

Evaluation of an Incremental Ventilation Energy Model for Estimating Impacts of Air Sealing and Mechanical Ventilation

Changing the rate of airflow through a home affects the annual thermal conditioning energy. Large-scale changes to airflow rates of the housing stock can significantly alter the energy consumption of the residential energy sector. However, the complexity of existing residential energy models hampers the ability to estimate the impact of policy changes on a state or nationwide level. The Incremental Ventilation Energy (IVE) model developed in this study was designed to combine the output of simple airflow models and a limited set of home characteristics to estimate the associated change in energy demand of homes. The IVE model was designed specifically to enable modelers to use existing databases of home characteristics to determine the impact of policy on ventilation at a population scale. In this report, we describe the IVE model and demonstrate that its estimates of energy change are comparable to the estimates of a wellvalidated, complex residential energy model when applied to homes with limited parameterization. Homes with extensive parameterization would be more accurately characterized by complex residential energy models. The demonstration included a range of home types, climates, and ventilation systems that cover a large fraction of the residential housing sector.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Revisiting dark energy models using differential ages of galaxies

In this work, we use a test based on the differential ages of galaxies for distinguishing the dark energy models. As proposed by Jimenez and Loeb in [1], relative ages of galaxies can be used to put constraints on various cosmological parameters. In the same vein, we reconstruct H {sub 0} {sub dt} / dz and its derivative ( H {sub 0} {sub d} {sup 2} {sup t} / dz {sup 2}) using a model independent technique called non-parametric smoothing . Basically, dt / dz is the change in the age of the object as a function of redshift which is directly linked with the Hubble parameter. Hence for reconstruction of this quantity, we use the most recent H ( z ) data. Further, we calculate H {sub 0} {sub dt} / dz and its derivative for several models like Phantom, Einstein de Sitter (EdS), ΛCDM, Chevallier-Polarski-Linder (CPL) parametrization, Jassal-Bagla-Padmanabhan (JBP) parametrization and Feng-Shen-Li-Li (FSLL) parametrization. We check the consistency of these models with the results of reconstruction obtained in a model independent way from the data. It is observed that H {sub 0} {sub dt} / dz as a tool is not able to distinguish between the ΛCDM, CPL, JBP and FSLL parametrizations but, as expected, EdS and Phantom models show noticeable deviation from the reconstructed results. Further, the derivative of H {sub 0} {sub dt} / dz for various dark energy models is more sensitive at low redshift. It is found that the FSLL model is not consistent with the reconstructed results, however, the ΛCDM model is in concordance with the 3σ region of the reconstruction at redshift z ≥ 0.3.

79 ASTRONOMY AND ASTROPHYSICS↗