Search NASA⌕ Search

SEARCH · Search NASA

Results for “EXTERIOR INSULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Energy and Moisture Impact of EIFS Walls in the USA

ABSTRACT This paper summarizes a family of computer simulations that have been performed to assess the hygrothermal performance of exterior insulation finish systems and discusses the validation of the model prior to its use. This research deals with evaluation of the performance of a number of selected wall systems in all 8 IECC USA climate zones. The research produced a range of performances that are representative of generic EIFS wall systems, and not for a specific manufactured product. A comparison was performed between three different EIFS walls and a brick wall system.

Desjarlais, Andre Omer↗

Efficient Solutions for New Homes Case Study: Savannah Gardens

The Savannah Housing Department is leading sustainable and affordable housing development in Georgia. It partnered with Southface Energy Institute, a member of the U.S. Department of Energy’s Partnership for Home Innovation Building America research team, to seek cost-effective solutions for increasing the energy efficiency of the Savannah Housing Department’s standard single-family home plans in the Savannah Gardens Community. Based on engineering, cost, and constructability analyses, the combined research team chose to pilot two technologies to evaluate efficiency and comfort impacts for homeowners: a heat-pump water heater in an encapsulated attic and an insulated exterior wall sheathing.

building america↗

Stand-Off Furring in Deep Energy Retrofits: Syracuse, New York (Fact Sheet)

IBACOS, in collaboration with GreenHomes America, was contracted by the New York State Energy Research and Development Authority to research exterior wall insulation solutions. This research investigated cost-effective deep energy retrofit (DER) solutions for improving the building shell exterior while achieving a cost-reduction goal, including reduced labor costs to reach a 50/50 split between material and labor. The strategies included exterior wall insulation plus energy upgrades as needed in the attic, mechanical and ventilation systems, and basement band joist, walls, and floors. The work can be integrated with other home improvements such as siding or window replacement. This strategy minimizes physical connections to existing wall studs, encapsulates existing siding materials (including lead paint) with spray foam, and creates a vented rain screen assembly to promote drying. GreenHomes America applied construction details created by IBACOS to a test home. 2x4 framing members were attached to the wall at band joists and top plates using 'L' clips, with spray foam insulating the wall after framing was installed. Windows were installed simultaneously with the framing, including extension jambs. The use of clips in specific areas provided the best strength potential, and 'picture framing' the spray foam held the 2x4s in place. Short-term testing was performed at this house, with monitoring equipment installed for long-term testing. Testing measurements will be provided in a later report, as well as utility impact (before and after), costs (labor and materials), construction time, standard specifications, and analysis for the exterior wall insulation strategy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Moisture and Structural Analysis for High Performance Hybrid Wall Assemblies

This report describes the work conducted by the Building Science Corporation (BSC) Building America Research Team's 'Energy Efficient Housing Research Partnerships' project. Based on past experience in the Building America program, they have found that combinations of materials and approaches—in other words, systems—usually provide optimum performance. No single manufacturer typically provides all of the components for an assembly, nor has the specific understanding of all the individual components necessary for optimum performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New York State Energy Research and Development Authority Exterior Building Solutions To Insulation

TO4 8.2.2: Space Cond. for Deep Energy Retrofits The purpose of this project for the New York State Energy Research and Development Authority (NYSERDA) is to find new or improved strategies for exterior building solutions in regard to insulation that will provide extensive energy-savings benefits for homeowners. Deep energy retrofits (DER) is one of the solutions. In the past, DERs have been expensive and hard for the average homeowner to budget. The DER solutions that IBACOS and GreenHomes America (GHA) are proposing will be market friendly, affordable, and easily repeatable. The insulation strategies that will be used on nine test homes include the following: - Rigid foam insulation - Four homes will have approximate center-of-wall R-values of R-28, including furring strips for siding, with additional systems approach work to supply the complete integrated DER solution. - Spray foam insulation - Four homes will have approximate center-of-wall R-values of R-30, with additional systems approach work to supply the complete integrated DER solution. - HPwES upgrade - One home will include criteria from the Home Performance with ENERGY STAR (HPwES) program, including dense pack walls and window upgrades for this retrofit strategy. In addition to the insulation, the strategies will include treatment where needed in the attic, mechanical systems, ventilation and basement band joist, walls, and floors.

acca manual rs↗

Technology Solutions Case Study: Stand-Off Furring in Deep Energy Retrofits

IBACOS, in collaboration with GreenHomes America, was contracted by the New York State Energy Research and Development Authority to research exterior wall insulation solutions. This research investigated cost-effective deep energy retrofit (DER) solutions for improving the building shell exterior while achieving a cost-reduction goal, including reduced labor costs to reach a 50/50 split between material and labor. The strategies included exterior wall insulation plus energy upgrades as needed in the attic, mechanical and ventilation systems, and basement band joist, walls, and floors. The work can be integrated with other home improvements such as siding or window replacement. This strategy minimizes physical connections to existing wall studs, encapsulates existing siding materials (including lead paint) with spray foam, and creates a vented rain screen assembly to promote drying. GreenHomes America applied construction details created by IBACOS to a test home. 2x4 framing members were attached to the wall at band joists and top plates using "L" clips, with spray foam insulating the wall after framing was installed. Windows were installed simultaneously with the framing, including extension jambs. The use of clips in specific areas provided the best strength potential, and "picture framing" the spray foam held the 2x4s in place. Short-term testing was performed at this house, with monitoring equipment installed for long-term testing.

Building America↗

Hygric Redistribution in Insulated Assemblies: Retrofitting Residential Envelopes Without Creating Moisture Issues

This research report was prepared by the Building Science Corporation Building America Research Team as part of the Energy Efficient Housing Research Partnerships project. The project title is Hygric Redistribution in Insulated Assemblies. The exterior retrofit of frame assemblies can be risky when impermeable insulating sheathings of relatively low thermal resistance are used. For example, basic hygrothermal analysis demonstrates that removing the existing cladding and installing a board foam insulation with low vapor permeance (such as ½-in. foil faced rigid insulation) directly over the sheathing membrane under a replacement cladding (such as vinyl siding) is likely to cause moisture problems in cold climates. One such problem is known as a “cold sided vapor barrier.” Tens of thousands of such retrofit and renovation projects have been completed, however, without apparent problems. There is also a perception that when water is intentionally drained in a drainage cavity between exterior insulation and the existing structure following an energy retrofit, moisture-related durability concerns exist for the sheathing and wood structure. This experimental program includes a literature review of previous research, laboratory testing programs, and an analysis of full-scale test wall performance in the U.S. Department of Energy’s climate zone 4C.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermally Anisotropic Composites for Heat Redirection and Thermal Management in Building Envelopes

In building envelope systems, thermal management is important from energy conservation and thermal comfort perspectives, and is typically done via insulation, thermal mass, solar control and shading, etc. Thermal anisotropy is commonly utilized in electronics for heat dissipation. This article investigates the feasibility of utilizing thermally anisotropic composites (TACs) to reduce unwanted heat gains and losses through the building envelope by redirecting the heat transfer to or from appropriate heat sinks and sources.Numerical simulations of building envelope components using COMSOL Multiphysics and whole building simulations using EnergyPlus (E+) were performed to estimate the energy savings potential of TACs used in external walls of residential buildings. Application of TACs was compared with baseline walls with cavity insulation as well as with and without exterior continuous insulation (CI). The COMSOL simulations indicated 75% or higher reductions in heat gains when using a TAC coupled with a heat sink compared to an exterior CI case. In terms of energy savings in a hot climate, E+ models estimated cooling energy savings of 19% with a "TAC + heat sink" compared to a baseline wall with only cavity insulation. Further, a small-scale test sample with a TAC-heat sink system was built and tested in a multi-transducer heat flow meter (HFM). The heat sink was a copper tube circulating cold water. The experiments verified the re-direction of heat to a sink and significant reduction in heat transfer through the test specimen. The experiments showed that the heat redirection only occurred in the presence of both thermal anisotropy and water circulation; if either element was missing, the system behaved like a traditional envelope component.

Biswas, Kaushik↗

Advanced Envelope Research for Factory Built Housing, Phase 3 - Whole-House Prototyping

The Advanced Envelope Research effort will provide factory homebuilders with high performance, cost-effective envelope designs that can be effectively integrated into the plant production process while meeting the thermal requirements of the 2012 IECC standards. Given the affordable nature of manufactured homes, impact on first cost is a major consideration in developing new envelope technologies. This work is part of a multi-phase effort. Phase 1 identified seven envelope technologies and provided a preliminary assessment of three methods for building high performance walls. Phase 2 focused on developing viable product designs, manufacturing strategies, addressing code and structural issues, and cost analysis of the three selected options. An industry advisory committee helped narrow the research focus to perfecting a stud wall design with exterior continuous insulation (CI). Phase 3, completed in two stages, continued the design development effort, exploring and evaluating a range or methods for applying CI to factory built homes. The scope also included material selection, manufacturing and cost analysis, and prototyping and testing. During this phase, a home was built with CI, evaluated, and placed in service. The experience of building a mock up wall section with CI and then constructing on line a prototype home resolved important concerns about how to integrate the material into the production process. First steps were taken toward finding least expensive approaches for incorporating CI in standard factory building practices and a preliminary assessment suggested that even at this early stage the technology is attractive when viewed from a life cycle cost perspective.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Envelope Research for Factory Built Housing, Phase 3. Whole-House Prototyping

The Advanced Envelope Research effort will provide factory homebuilders with high performance, cost-effective envelope designs that can be effectively integrated into the plant production process while meeting the thermal requirements of the 2012 IECC standards. This work is part of a multiphase effort. Phase 1 identified seven envelope technologies and provided a preliminary assessment of three methods for building high performance walls. Phase 2 focused on developing viable product designs, manufacturing strategies, addressing code and structural issues, and cost analysis of the three selected options. An industry advisory committee helped narrow the research focus to perfecting a stud wall design with exterior continuous insulation (CI). This report describes Phase 3, which was completed in two stages and continued the design development effort, exploring and evaluating a range or methods for applying CI to factory built homes. The scope also included material selection, manufacturing and cost analysis, and prototyping and testing. During this phase, a home was built with CI, evaluated, and placed in service. The experience of building a mock up wall section with CI and then constructing on line a prototype home resolved important concerns about how to integrate the material into the production process. First steps were taken toward finding least expensive approaches for incorporating CI in standard factory building practices and a preliminary assessment suggested that even at this early stage the technology is attractive when viewed from a life cycle cost perspective.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental and numerical evaluations of the energy savings potential of thermally anisotropic composites

Previous numerical studies conducted in FY 17 showed that the application of thermally anisotropic composites (TACs) coupled with a heat sink/source can re-direct and reduce unwanted heat flows through exterior building walls, with associated reductions in envelope-generated heating and cooling loads in buildings. The numerical analyses included two-dimensional finite element models (FEM) of wall assemblies and whole-building modeling to estimate the annual reductions in wall-generated heating and cooling loads, and associated energy consumption. The FY17 study used combined FEM and EnergyPlus (E+) simulations of a typical two-story, single-family DOE prototype residential building model.1 We studied performance of several configurations of walls containing exterior continuous insulation and thermally anisotropic composites on the wall exterior. The study showed that annual energy cost savings of up to $270 are possible under Phoenix and Baltimore weather conditions, by retrofitting a baseline wall with an anisotropic composite. In the cases considered, the TAC consisted of three layers of aluminum foil-faced foam boards. In general, it was found that the anisotropic composites were effective in reducing cooling loads; more investigation on heating loads is needed. During FY 18, ORNL performed a series of laboratory tests of anisotropic composites and appropriate heat sink/source, validated the FEMs used for the FY17 numerical study using experimental data, and revisited the whole-building modeling. Wall prototypes were created and tested in ORNL’s large scale climate simulator (LSCS) under variable conditions approximating summer and winter time periods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hygric Redistribution in Insulated Assemblies. Retrofitting Residential Envelopes Without Creating Moisture Issues

The Building America program has recognized that most of the current housing stock is in need of energy related retrofits. One of the best ways of reducing the space conditioning energy consumption is to improve the thermal performance of the enclosure by adding exterior board foam insulation. This report quantifies the amount of water that can become trapped in the drainage cavity of typical wall systems, and measures the effect of water trapped in the drainage cavity on the moisture content of the sheathing. This study also attempts to explain the discrepancy between hygrothermal simulations and field performance of low permeance, low R-value exterior insulation (e.g. ¾-in. foil faced polyisocyanurate) in cold climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Case Studies of Residential Façade Upgrades in Four Climate Zones

This paper reports on a project that explored the viability of insulation and window upgrades during siding retrofits in four case studies across the United States. Thousands of homes are re-sided every year, but only a fraction of consumers add insulation and upgrade the windows at the same time, even though a siding replacement is the ideal time to update the thermal performance of building enclosures. To better understand why more siding retrofits do not include insulation and window upgrades, research staff from several organizations collaborated with the U.S. Department of Energy on a multi-faceted research project that included a cost analysis, workforce analysis, market assessment, and contractor assessment. This paper will review four in-field case studies conducted with contractors actively engaged in home re-siding projects that agreed to add rigid insulation and window upgrades as part of their projects. Findings from the case studies will be presented including contractor perspectives, cost, and technical approaches on projects, located in multiple climate zones including Bellingham WA, Jackson MS, Kalamazoo MI, and Phoenix AZ. All projects involved adding continuous rigid insulation on the exterior walls and installation of new cladding. Cladding types varied from wood and metal to fiber cement, vinyl, and traditional stucco. All homes also received a window upgrade, although upgrades varied depending on the original condition of the windows and climate; upgrades included triple-pane windows, low-e storm windows, and exterior shading. Key findings including technical approaches, opportunities, barriers, and project cost will be presented.

re-siding, insulation, rigid insulation, exterior ↗

The Performance House: A Cold Climate Challenge Home - Old Greenwich

Working with builder partners on test homes allows for vetting of whole-house building strategies to eliminate any potential unintended consequences prior to implementing these solution packages on a production scale. To support this research, the Consortium for Advanced Residential Buildings partnered with Preferred Builders Inc. on a high performance test home in Old Greenwich, Connecticut. The philosophy and science behind the 2,700 ft2 Performance House were based on the premise that homes should be safe, healthy, comfortable, durable, efficient, and adapt with the homeowners. The technologies and strategies used in the Performance House were not cutting-edge, but simply best practices practiced. The focus was on simplicity in construction, maintenance, and operation. When seeking a 30% source energy savings targets over a comparable 2009 International Energy Conservation Code-built home in the cold climate zone, nearly all components of a home must be optimized. Careful planning and design are critical. The Performance House demonstrates how a home can be designed and constructed in the cold climate zone to be energy efficient, low maintenance, sustainable, and comfortable. Lower price premiums are still needed for solutions such as ccSPF and light-emitting diodes, but this is anticipated as their market demand increases. For a solution package of this level to become commercially viable, there is still a need to improve the home appraisal process to better value the multiple benefits of a solution package of this type over standard builder practices.

accessibility↗

Technology Solutions Case Study: High-Performance Walls in Hot-Dry Climates

In this project,the Alliance for Residential Building Innovation (ARBI) team worked with builders in California to implement wall assemblies meeting a U-value lower than 0.050 Btu/h-ft2-°F. ARBI and its project team members helped builders identify preferred wall designs that met the requirements of their architects, structural engineers, and purchasing agents and that were acceptable to their subcontractors. Construction methods were observed and documented and construction costs obtained from builders were used to inform cost estimates for a range of advanced wall system types and insulation types. Wall framing types of 2 × 6 (16- and 24-in. on center [o.c.]) and double stud were modeled in Building Energy Optimization (BEopt™) software with cavity insulation levels ranging from R-19 to R-33 (double stud) and exterior rigid insulation of R-4, R-6, and R-8.

ARBI↗

Transformative Efficiency and Automation in Modular Homes (TEAMH)

This report documents the Transformative Efficiency and Automation in Modular Homes (TEAMH) project, which evaluates the integration of advanced building envelope technologies and automation-assisted modular construction to improve residential energy performance and construction efficiency. The study investigates high-performance insulation systems, including vacuum insulation panels (VIPs), combined with light gauge steel (LGS) modular construction and factory automation. Laboratory testing, whole-building energy modeling across multiple climate zones, and factory demonstrations were conducted to assess thermal performance, energy savings, and production efficiency. Results indicate that upgraded envelope assemblies can achieve up to ~50% heating and ~34% cooling energy savings relative to IECC 2018 code-compliant homes, while automation-assisted construction can reduce wall assembly time by 24%–46% compared to conventional wood framing. The findings demonstrate the potential for scalable, high-performance modular homes that deliver significant energy savings with competitive projected costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗