Operation at Reduced Atmospheric Pressure and Concept of Reliability Redundancy for Optimized Design of Insulation Systems

Electrified transportation is calling for insulation design criteria that is adequate to provide elevated levels of power density, power dynamics and reliability. Increasing voltage levels are expected to cause accelerated intrinsic and extrinsic aging effects which will not be easily predictable at the design stage due to a lack of suitable modeling. Designing reliable insulation systems would require finding solutions able to control accelerated aging due to an unpredictable increase of intrinsic stresses and the onset of extrinsic stresses as partial discharges. This paper proposes the concept of reliability redundancy for the insulation design of aerospace electrical asset components, which is also validated at lower-than-standard atmospheric pressure. The principle is that extrinsic-aging-free design might be achieved upon determining the aging stress or abnormal service stresses distribution and being sure that aging will not generate conditions that can incept extrinsic aging (partial discharges) during operation life. However, such information is never, in practice, fully available to insulation system designers. Hence, especially in critical applications such as electrified aircraft, aerospace, and combat ships a further level of reliability should be added to a partial-discharge-free design, which can consist of the use of corona-resistant materials and/or of life models able to consider the accelerated aging effect of partial discharges (or any other type of extrinsic-accelerated aging factor). Innovative life modeling considering both extrinsic and intrinsic aging stresses, insulating material testing to estimate model parameters, and a metric for quantifying the extent of corona (or partial discharge) resistance can lead to establishing feasibility and limit conditions for optimized or fully reliability-redundant design. It is shown in the paper that if an extrinsic-aging-free design is not feasible, and it is therefore replaced by a redundant design, a further level of reliability redundancy can be provided by effective condition monitoring plans.

Montanari, Gian Carlo↗

Multiple Stream Low-Cost Recycling Method

The global composite industry generates large quantities of waste and which mostly end as landfill due to lack of meaningful end-use applications for the multiple waste streams. In a recent report by the Electric Power Research Institute (EPRI), waste generated by the wind industry could reach 370,000 tons a year of composite wind energy blades being decommissioned and scrapped. Wind energy is just one major industry utilizing composite materials. The waste generated by industry includes End-of-Life (EoL) materials and manufacturing process scrap. GreenTex Solutions has developed a unique and innovative technology to recycle the composite waste streams in a range of forms made from production waste and EoL materials. This includes manufacturing waste materials such as dry chopped fiber tow, loose fibers, shredded fibers from reinforcement fabrics, cured/semi-cured prepregs, and it also includes fully-cured composite structure waste (such as edge trims from cured parts) from manufacturing aircraft, automobiles, wind blades, boats, and composite cylinders (tanks). Current recycling methods involve recovering the structural fiber by removing the matrix resin through methods such as pyrolysis. The resulting fibers are used in injection molding or wet laid nonwoven mats and other usable forms. The GreenTex technology bypasses these intermediate steps to create the lowest possible recycling processing costs and the lowest embodied energy/CO2 emissions. The end-product from the GreenTex technology is a finished industrial composite part/application versus intermediate fibers or fabrics. The GreenTex manufacturing process enables cross-industry reuse of recycled feedstock by taking waste from multiple industries (wind energy, aerospace, marine, etc.) and recycles the waste into a product used in other industries. The initial target market application is structural flooring for intermodal shipping containers and truck bodies. One of the team’s key partners is Wabash National which produced 29,000 truck bodies in 2019. The current flooring system is comprised of solid oak “butcher board” laminated panels. Additionally, Mediterranean Shipping Containers (MSC) transports over 1.8 million twenty-foot equivalent units per year in intermodal shipping containers. The current container floor is laminated hardwood that is harvested from the rain forests of Central and South America. The project is to develop a flooring system made from recycled composites that can be qualified for both companies (Wabash and MSC). Initial prototypes validated that the recycled composites panels are lighter and thinner with much higher mechanical strength. These results suggest a typical truck trailer would have 20% lower tare weight. The GreenTex technology is not limited to flooring and is widely applicable to other transportation elements such as walls, roof elements, cab areas and related structural components. Under this project different composite waste streams were evaluated and then combined to develop a formulation that would meet the targeted performance criteria for a flooring system. Wet compression molding was used to fabricate plaques at different tonnage using various composite waste streams. The plaques were tested for flexure and impact.

36 MATERIALS SCIENCE↗

Internal arcing and lightning strike damage in short carbon fiber reinforced thermoplastic composites

Short carbon fiber reinforced thermoplastic composites (S-CFRTP) are currently used in interior parts of aircraft such as electronic circuitry and assemblies, and their usage in aircraft's exterior is also being studied. In this paper, we present a lightning strike study on S-CFRTPs. High performance thermoplastics such as a polyphenylene sulfide (PPS) reinforced with 50% weight (wt.) short carbon fiber (CF), a polyphenyl sulfone (PPSU) reinforced with 25 % wt. Short CF and a acrylonitrile butadiene styrene (ABS) with 20 % wt. short CF were tested against artificial lightning strikes. All samples were prepared using an extrusion compression molding (ECM) technique. A modified component A (100 kA) of lightning waveform, as defined by SAE ARP 5412-B, was applied. High speed imaging, thermography, scanning electron microscopy (SEM) and ultrasonic non-destructive evaluation were performed to understand the effect of lightning strikes on the thermoplastic panels. The results show that electrical conductivity of the composite, thermal stability of the polymers, and CF orientation significantly affected the damage from artificial lightning strikes. PPS composite had the highest resilience against lightning strike damage, retaining 95% and 89% residual flexural strength and modulus, respectively. CF exfoliation due to internal arcing was observed in the carbon fiber-reinforced ABS polymer (CF-ABS) composite. CF exfoliation damage has been reported for the first time.

36 MATERIALS SCIENCE↗

Life-cycle analysis of sustainable aviation fuel production through catalytic hydrothermolysis

Catalytic hydrothermolysis (CH) is a sustainable aviation fuel (SAF) pathway that has been recently approved for use in aircraft fuel production. In alignment with broader sustainable aviation goals, SAF production through CH requires a quantitative assessment of carbon intensity (CI) impacts. In this study, a current-day life-cycle analysis (LCA) was performed on SAF produced via CH to determine the CI. Various oily feedstocks were considered, including vegetable oils (soybean, carinata, camelina and canola) and low-burden oils and greases (corn oil, yellow grease and brown grease). Life-cycle inventory data were collected on all processes within the CH LCA boundary: feedstock cultivation and/or collection, preprocessing, hydrothermal cleanup and CH, biocrude refining, fuel transportation and end use through combustion. Baseline results show that the CH-produced SAF can be generated with CI reductions ranging from 48 to 82% compared with conventional jet fuel. Modest improvements to CI can be achieved through incremental changes to the brown grease CH process, such as relaxing the dewatering specification and implementing renewable natural gas and electricity, which could decrease the CI from 22.9 to 7.9 g CO 2 e/MJ. Total CH fuel production potential was also assessed on the basis of current or near-future feedstock availability and CI. The total biofuel production potential of CH (SAF and renewable fuel co-products) in the US sums to approximately 3487 million gallons per year, with 97% of these volumes having a CI below 50% of that for petroleum jet fuel. The study shows that from an LCA perspective, CH offers a viable SAF pathway that is comparable with existing SAF pathways like hydroprocessed esters and fatty acids.

09 BIOMASS FUELS↗

SSTDR and FDR Detection of Un-Energized and Energized Cable Anomalies Including Thermal Degradation Using Machine Learning

Historically, cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, continued use of these cables must shift to a performance-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. A variety of cable tests are available and are commonly applied during outages when the cables can be taken out of service. Frequency domain reflectometry (FDR) is one of these test methods that is being more broadly accepted and used because it not only detects anomalies along the cable with a low-voltage signal that does not stress the cable insulation, but the technique also locates the anomalies. This supports follow-up local inspection and local repair or partial replacement of a damaged cable segment. Currently, FDR testing is only applied to cables that are taken out of service since the test instrument would be damaged by operational voltages. A related technology that has found some acceptance in the aircraft and rail industry is spread spectrum time domain reflectometry (SSTDR). This technology has been implemented with a custom commercial instrument by LiveWire Innovation that is designed to operate on live cables up to 1000 volts and with a bandwidth of 48 MHz. Initial evaluation by the Pacific Northwest National Laboratory (PNNL) of the Live Wire system indicated that a broader bandwidth (BW) SSTDR may be better for many kinds of flaws. This led PNNL to develop an SSTDR laboratory instrument suitable for tests up to 500 MHz bandwidth. Testing on energized cables is also desirable for online monitoring systems so an inductive clamshell coupler was developed that allows energized cables to be tested up to at least 5 kV and likely higher voltage levels. Dielectric spectroscopy and tan delta testing plus various laboratory destructive tests were included in this data acquisition campaign directed to feed a machine learning (ML) study. With these kinds of developments, online energized cable tests may be possible with industrial adoption of such hardware advances but it will be completely impractical to have highly skilled data analysts continually examine these complex signals for indications of damage or compromised conditions. If online testing is to be implemented in new test hardware, it must be accompanied by software that can interpret the signals and alert plant operators of changing or degraded conditions. The thermally aged, shielded cable investigated here was separately treated for ML analysis. Visual analysis of electrical data showed generally increasing peaks where the cable entered and exited the oven. These peaks were not exactly aligned with expected locations, but these differences were attributed to velocity of propagation calibration errors. Only supervised ML was applied to the thermally aged data as this data was only available shortly before the committed publication date of this report. The supervised ML was structured to divide the 0 to 70-day responses as ‘normal’ from 0 to 35 days or ‘anomalous’ from 36 to 70 days, based on cable tensile elongation at break (EAB) insulation characterization. Using 80% of the data for training and 20% for testing, the supervised ML predicted normal versus anomalous was 70% accurate. Important conclusions include: • Accuracy to predict the presence of cable damage is improved from the 2023 effort by more training data. Weighted accuracies for comparisons among the instruments ranged from 67 to 89 % for unsupervised ML and 71 to 99% for supervised ML. • Based on the synthetic data tests, the unsupervised models are more generalizable to unseen anomalies. The Multi-Layer Perceptron classifier (MLP) model reported as high as 99.7% accuracy on the test data, but this dropped to 58.3% when tested on the synthetic data. In contrast, the unsupervised Pointwise model only achieved 89.7% accuracy on the experimental data but reported 78.3% accuracy on the synthetic data. • The best anomaly indicators are higher frequency (400 MHz BW) FDR data. Other tests may be interesting but for this study, this was the best predicter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Online Monitoring of Medium Voltage Cable Systems with Spread Spectrum Time Domain and Frequency Domain Reflectometry

In-service failures of wave energy convertor (WEC) cable systems can have a significant cost and power availability impact. Close parallel research 2019 data showed > 1B£ and 9 Terra-Watt-Hours associated with global off-shore wind (OSW) cable failures (Strang-Moran 2020). OSW is a closely related technology but currently is significantly cheaper than WEC technology. For wave energy to compete, the problem of reliable cable transmission must be mitigated. This project develops isolation technology to allow online high frequency reflectometry testing of medium voltage cables (1 to 10 kV and higher) without arcing or damage to the test instrument. Online spread spectrum time domain reflectometry (SSTDR) testing has been established for low voltage cable systems in the aircraft and rail industry and the ability to detect and locate cable flaws of interest is well understood. Extending reflectometry testing to medium voltage systems could enable detection of cable damage before failures occur thereby allowing repair and replacement of damaged cable segments to be scheduled and managed. The seedling project succeeded to pass and receive high frequency SSTDR signals onto a cable up to 1 kV using a parallel trace isolation circuit board that can be connected onto the test cable. The approach used a novel circuit design for which an invention disclosure has been filed. A proposed sapling project would extend the technology toward the higher operating voltages used by WEC systems, thereby enabling online SSTDR cable monitoring. The goal of the seedling project was to extend the capability of the ARENA cable/motor test bed to address medium voltages and to develop a high pass filter isolation architecture to protect the reflectometry instrument from the low frequency (DC – 60 Hz) line voltage while allowing the high frequency diagnostic signal to pass to and from the test instrument to the live line. Initial efforts focused on passive LCR filter circuits to reduce 60 Hz levels below 10 volts from a 10 kV line while allowing the MHz high frequency chirps to pass onto the cables and for mV signals to be detected. We discovered that the parasitic loss behavior of real high voltage components precluded this approach from working. An alternate approach was adapted for the electric field to couple between two parallel traces on a printed circuit board much like a radio-frequency coupler. The challenge here was and is to have the parallel traces close enough to each other to effectively pass the high frequency chirp onto the live line and receive any reflected signal from any encountered impedance change along the cable. This reflected signal will be in the mV range. The traces however must be far enough apart to not allow arcing on the board. A design with 3 mm spacing was determined to allow the high frequency signal to pass onto the live line and receive the mV signal back into the instrument while reducing the 60 Hz voltage amplitude by >80 dB (more than a factor of 10,000) without allowing arcing from across the parallel traces. This was confirmed by simulation and test.

16 TIDAL AND WAVE POWER↗

Extended Bandwidth Spread Spectrum Time Domain Reflectometry Cable Test for Thermal Aging, Low Resistance Fault, and Water Detection

In 2022, researchers at Pacific Northwest National Laboratory (PNNL) used the Accelerated and Real-Time Environmental Nodal Assessment (ARENA) cable and motor test bed to characterize spread spectrum time domain reflectometry (SSTDR) and compare the responses of an SSTDR instrument to those of a frequency domain reflectometry (FDR) instrument. Results showed both techniques could detect and locate cable anomalies such as phase-to-phase low resistance and shorts, thermal insulation damage, mechanical insulation damage, and the presence or absence of water in some conditions. The SSTDR tests used a commercial instrument provided by LiveWire Innovations Inc. This commercial instrument performed tests at 6, 12, 24, and 48 MHz bandwidth. The results of these tests were compared to FDR tests where bandwidths could be extended up to 1.3 GHz, although the best responses for cable tests were from 100 to 500 MHz. Lower bandwidth signals can propagate better along the cable while higher bandwidths have higher resolution for impedance change reflections allowing more precise indication of location and separation of anomalies. The 2022 research found that FDR responses were clearer than SSTDR and speculated that a higher bandwidth SSTDR could more successfully detect and locate cable anomalies. One advantage of the SSTDR system investigated was that it was designed for energized online use up to 1,000 volts, which may be a significant advantage for nuclear power plant use. The LiveWire SSTDR instrument is an established product in the rail and aircraft industry and updating the SSTDR hardware parameters is difficult to justify without more conclusive testing. Therefore, a software adjustable laboratory SSTDR instrument was developed by PNNL and was used to test extended bandwidth SSTDR cable tests. Within the ARENA test bed, 42 cable conditions were tested with the PNNL SSTDR, FDR, and the LiveWire SSTDR—each operating at four different bandwidths. Observations and conclusions regarding the relative performance of the three instruments over different bandwidths are note below. Responses of the PNNL SSTDR (at 50 MHz) and the LiveWire SSTDR (at 48 MHz) were similar. The PNNL SSTDR higher frequency bandwidths behaved as expected showing sharper peaks and higher noise. This validated the PNNL SSTDR as a reasonable implementation of the SSTDR technology. Lower bandwidth SSTDR responses (particularly 6 and 12 MHz) may have increased value for use within longer cables but were not particularly effective at identifying anomalous cable behavior in the 100 ft cables tested here. The higher bandwidths of the PNNL SSTDR (50, 100, 200, and 400 MHz) did not provide substantially clearer cable reflectometry responses, but having the higher frequency responses available did add to the cable test evaluation. Strong responses to shorts and low impedance faults between phases were particularly evident in the higher bandwidth PNNL SSTDR and the FDR data. Measurements were repeatable, with similar responses obtained from a thermally aged cable for tests taken a month apart. Signal noise was affected in the unshielded cable by the local in-tray cable arrangement including proximity to metal edges and rungs of the cable tray. Foam isolation of the cable from the tray metal reduced in both FDR and SSTDR responses. Cable condition monitoring in nuclear power plants will likely benefit from both more informative off-line testing methods and from the development of on-line methods for continuous monitoring of cables in use. The LWRS-funded ARENA test bed was a valuable resource for this development and direct comparison of nuclear electrical cable condition monitoring technologies. Test results are targeted to guide industry advancement of testing and monitoring tools for cable aging management.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Molten Salt Reactor Signatures and Modeling Study

Molten salt reactor (MSR) technologies, either liquid fueled and cooled or only liquid cooled, pose specific, unique challenges for safeguards of the special nuclear material during the operation, fueling, and maintenance of the reactor. MSRs are one type of Generation IV technologies being invested in and considered for U.S. domestic fabrication primarily for electricity and process heat production. These designs have generated growing commercial interest for several reasons, including high (≈40%) thermal efficiency, ease of fueling, improved use of uranium fuel, potential utilization of thorium fuel, and proposed inherent safety features. U.S. companies have several planned designs that differ in fuel, cooling, and neutron energy spectrum. Driven by commercial interest and the intent of licensing MSRs, the U.S. Nuclear Regulatory Commission (NRC) has developed a vision and strategy to accommodate non-light water reactors (LWR), which include MSRs (U.S. Nuclear Regulatory Commission 2019). In addition, the Department of Energy (DOE) through the Office of Nuclear Energy (NE) Office of Advanced Reactor Technologies (ART), …sponsors research, development and deployment (RD&D) activities through its Next Generation Nuclear Plant (NGNP), Advanced Reactor Concepts (ARC), and Advanced Small Modular Reactor (aSMR) programs to promote safety, technical, economical, and environmental advancements of innovative Generation IV nuclear energy technologies. Reactor types considering the use of salts, liquid metals, or gases for coolant fall under both ARC and aSMR. Therefore, Research Design & Development is being pursued by DOE-NE through national laboratories, universities, and international and industrial collaborations. Additionally, the U.S. is a member of the Gen IV International Forum (GIF). The GIF is a cooperative, multinational organization to guide and carry out research and development needed for the GEN IV reactor systems (Forum 2018). GIF evaluated numerous reactor concepts and down-selected to the six most feasible advanced reactor technologies: gas-cooled fast reactor (GFR), lead-cooled fast reactor (LFR), MSR, supercritical watercooled reactor (SCWR), sodium-cooled fast reactor (SFR), and very high temperature reactor (VHTR). In support of the growing interest domestically and internationally, the Materials Protection, Accounting, and Control Technologies (MPACT) campaign, under the DOE-NE Fuel Cycle Technologies (FCT) program, engages in R&D activities by developing advanced instrumentation and analysis for safeguards and security of modern, advanced nuclear fuel cycle (non-LWR) facilities. Because of the historic experience in the operation of the Aircraft Reactor Experiment (ARE) and the Molten Salt Reactor Experiment (MSRE) (Robertson, MSRE Design and Operations Report Part I 1965), Oak Ridge National Laboratory (ORNL) is heavily engaged in the various R&D activities through the DOE complex related to MSRs including national technical leadership of the DOE-NE MSR campaign. This report discusses and presents the outcomes of the FY19 MPACT MSR Safeguards task. The challenges presented by MSRs for nuclear material accountancy and control (NMAC) and associated safeguards will be investigated. The objective of this research is to explore and compile the safeguards requirements and identify measurement signatures through an initial high-level MSR design and develop complementary advanced simulation and modeling capabilities. A high-level ORNL-developed MSR design called the Molten Salt Demonstration Reactor (MSDR) (Bettis, Alexander and Watts 1972) was used as the target reactor design for this research. The MSDR model incorporates technology from the MSRE and the Molten Salt Breeder Reactor (Robertson, Conceptual Design of a Single-Fluid Molten-Salt Breeder Reactor 1971). But the MSDR is a 750 MWth graphite moderated liquid fueled (low-enriched uranium) MSR compared to the MSRE’s of 7.5 MWth. The focus of this report is to discuss the evaluation of novel signatures, correlations, and indicators to understand the applicability of current safeguards instrumentation to MSRs using the modeling results from the MSDR.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Nondestructive Evaluation (NDE) of Cable Anomalies using Frequency Domain Reflectometry (FDR) and Spread Spectrum Time Domain Reflectometry (SSTDR)

This report presents a comparative assessment of the performance of frequency domain reflectometry (FDR) and spread spectrum time domain reflectometry (SSTDR) in detecting a wide range of electrical cable anomalies. All tests and results reported herein were performed at the PNNL Accelerated and Real-Time Environmental Nodal Assessment (ARENA) cable and motor test bed. The primary objective of this work was to evaluate the effectiveness of SSTDR, a fledgling cable monitoring technique that shows promise for application in online monitoring of energized cable systems, against FDR, an offline technique widely employed in the nuclear power plant (NPP) industry. FDR tests are becoming more widely used in nuclear power plant cable aging management and test programs – particularly for low voltage cables. FDR capabilities for these kinds of tests have been reported by PNNL and others. The FDR test is performed on de-energized cables by connecting the FDR instrument to two of the cable conductors, or one conductor and the shield. A broad band low voltage (< 5 V) chirp is introduced in the cable, and any reflected response is captured in the frequency domain. The captured reflection is then processed by performing an inverse Fourier transform to a time domain response which can then be converted to a distance response based on the cable velocity of propagation (VoP). SSTDR measurements are functionally similar to FDR measurements in that a broad-band voltage signal composed of a square or sine wave modulated pseudo-random sequence of chips (< 5 volts), is injected onto one of the cable conductors. The injected signal will experience partial energy reflection and transmission at each impedance discontinuity along the transmission line. Any reflected response is detected by computing a cross-correlation between the reflected signals and a delayed copy of the incident SSTDR signal. the time delay for the reflected signal to experience the best matched correlation with the incident signal, indicates the travel time for the signal to reach a change in impedance. By knowing this time delay and velocity of propagation (VoP) of the signal, one can compute the physical distance. A big advantage that SSTDR measurements have over other methods is the ability to be connected to energized or live wires (currently up to 1kV) thereby enabling online monitoring of cables. SSTDR has been used successfully in several applications, e.g., aircraft, rail, and photovoltaic systems. In this work FDR and SSTDR cable assessment techniques were used to characterize a variety of cable anomalies and faults including: (1) Presence or absence of a motor; (2) Ground faults and short circuit faults; (3) Moist environments and water ingress faults; (4) Accelerated thermal aging. Both shielded and non-shielded cables were evaluated in this report. Offline measurements were made using FDR and online measurements were made by SSTDR for a range of test scenarios. Based on the results across all cable anomalies evaluated in this study, FDR displayed high sensitivity towards cable condition assessment, while SSTDR showed promise for future application in monitoring NPP cable systems. However, further developments are suggested to improve the resolution and sensitivity of SSTDR towards faults and anomalies in low voltage cables.rt presents a comparative

42 ENGINEERING↗