Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrical imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Graphene Electric Field Sensor Enables Single Shot Label-Free Imaging of Bioelectric Potentials

The measurement of electrical activity across systems of excitable cells underlies current progress in neuroscience, cardiac pharmacology, and neurotechnology. However, bioelectricity spans orders of magnitude in intensity, space, and time, posing substantial technological challenges. The development of methods permitting network-scale recordings with high spatial resolution remains key to studies of electrogenic cells, emergent networks, and bioelectric computation. Here, for this work, we demonstrate single-shot and label-free imaging of extracellular potentials with high resolution across a wide field-of-view. The critically coupled waveguide-amplified graphene electric field (CAGE) sensor leverages the field-sensitive optical transitions in graphene to convert electric potentials into the optical regime. As a proof-of-concept, we use the CAGE sensor to detect native electrical activity from cardiac action potentials with tens-of-microns resolution, simultaneously map the propagation of these potentials at tissue-scale, and monitor their modification by pharmacological agents. This platform is robust, scalable, and compatible with existing microscopy techniques for multimodal correlative imaging.

47 OTHER INSTRUMENTATION↗

High-speed imaging of transition from fluid breakup to phase explosion in electric explosion of tungsten wires in air

High-speed visible imaging of sub-microsecond electric explosion of wires at the low specific energy deposition threshold reveals three distinct modes of wire failure as capacitor charge voltage and energy deposition are increased. For 100 micron diameter gold-plated tungsten wires of 2 cm length, deposited energies of 1.9 eV/atom produces a liquid column that undergoes hydrodynamic breakup into droplets with radii of order of wire diameter on timescales of 200 μs. Instability growth, column breakup, and droplet coalescence follow classic Rayleigh-Plateau predictions for instability of viscous fluid column. Above 3.2 eV/atom of deposited energy, wires are seen to abruptly transition to an expanding mixture of micron scale liquid-droplets and vapor within one frame (less than 3.33 μs), which has been termed ‘phase explosion’ in literature. Between these two limits, at 2.5 eV/atom of deposited energy, wire radius is unchanged for the first 10 μs before the onset of a rapid expansion and disintegration that resembles homogenous nucleation of mechanically unstable bubbles. Here, thermodynamic calculations are presented that separate cases by temperature obtained during heating: below boiling point, near boiling point, and exceeding boiling point.

42 ENGINEERING↗

Image processing via ultrasonics - Status and promise

Acousto-electric devices for electronic imaging of light are discussed. These devices are more versatile than line scan imaging devices in current use. They have the capability of presenting the image information in a variety of modes. The image can be read out in the conventional line scan mode. It can be read out in the form of the Fourier, Hadamard, or other transform. One can take the transform along one direction of the image and line scan in the other direction, or perform other combinations of image processing functions. This is accomplished by applying the appropriate electrical input signals to the device. Since the electrical output signal of these devices can be detected in a synchronous mode, substantial noise reduction is possible

Kornreich, P. G.↗

Development of polarization-sensitive optical coherence tomography imaging platform and metrics to quantify electrostimulation-induced peripheral nerve injury in vivo in a small animal model

Neuromodulation devices are rapidly evolving for the treatment of neurological diseases and conditions. Injury from implantation or long-term use without obvious functional losses is often only detectable through terminal histology. New technologies are needed that assess the peripheral nervous system (PNS) under normal and diseased or injured conditions. We aim to demonstrate an imaging and stimulation platform that can elucidate the biological mechanisms and impacts of neurostimulation in the PNS and apply it to the sciatic nerve to extract imaging metrics indicating electrical overstimulation. A sciatic nerve injury model in a 15-rat cohort was observed using a newly developed imaging and stimulation platform that can detect electrical overstimulation effects with polarization-sensitive optical coherence tomography. The sciatic nerve was electrically stimulated using a custom-developed nerve holder with embedded electrodes for 1 h, followed by a 1-h recovery period, delivered at above-threshold Shannon model k-values in experimental groups: sham control (SC, n = 5, 0.0 mA / 0 Hz), stimulation level 1 (SL1, n = 5, 3.4 mA / 50 Hz, and k = 2.57), and stimulation level 2 (SL2, n = 5, 6.8 mA / 100 Hz, and k = 3.17). The stimulation and imaging system successfully captured study data across the cohort. When compared to a SC after a 1-week recovery, the fascicle closest to the stimulation lead showed an average change of +4 % / – 309 % (SL1/SL2) in phase retardation and –79 % / – 148 % in optical attenuation relative to SC. Analysis of immunohistochemistry (IHC) shows a +1 % / – 36 % difference in myelin pixel counts and –13 % / + 29 % difference in axon pixel counts, and an overall increase in cell nuclei pixel count of +20 % / + 35 % . These metrics were consistent with IHC and hematoxylin/eosin tissue section analysis. The poststimulation changes observed in our study are manifestations of nerve injury and repair, specifically degeneration and angiogenesis. Optical imaging metrics quantify these processes and may help evaluate the safety and efficacy of neuromodulation devices.

60 APPLIED LIFE SCIENCES↗

Simultaneous Imaging of Molecular Rovibrational Nonequilibrium, Reactive Species, and Electric Field for Plasma-Assisted Chemistry

The Sandia-PRF has built a new capability for the low-temperature plasma community for the simultaneous imaging of molecular rotation/vibration nonequilibrium, electric field, and the distribution of OH radical and formaldehyde in reactive low temperature plasma systems. The system is currently investigating the plasma-assisted deflagration to detonation transition in a micro-combustor channel.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Imaging Field–Driven Melting of a Molecular Solid at the Atomic Scale

Solid–liquid phase transitions are basic physical processes, but atomically resolved microscopy has yet to capture their full dynamics. A new technique is developed for controlling the melting and freezing of self–assembled molecular structures on a graphene field–effect transistor (FET) that allows phase–transition behavior to be imaged using atomically resolved scanning tunneling microscopy. This is achieved by applying electric fields to 2,3,5,6–tetrafluoro–7,7,8,8–tetracyanoquinodimethane–decorated FETs to induce reversible transitions between molecular solid and liquid phases at the FET surface. Nonequilibrium melting dynamics are visualized by rapidly heating the graphene substrate with an electrical current and imaging the resulting evolution toward new 2D equilibrium states. An analytical model is developed that explains observed mixed–state phases based on spectroscopic measurement of solid and liquid molecular energy levels. The observed nonequilibrium melting dynamics are consistent with Monte Carlo simulations.

36 MATERIALS SCIENCE↗

Electrical Resistivity Tomography Monitoring of In Situ Soil Flushing at the Hanford 100-K East Area: 100KE Soil Flushing Monitoring

Former operations in the 100-KE Area at the Hanford Site resulted in vadose zone hexavalent chromium that provides a source of groundwater contamination. Previous efforts to remediate vadose zone chromium involved excavation and offsite treatment of contaminated soils. Although much of the chromium was removed, contamination still exists in native soil between the water table and the bottom of the pit, which has since been backfilled. In-situ soil flushing was tested at the 100-KE Area to accelerate the removal of the remaining hexavalent chromium in the vadose zone. Soil flushing works by applying clean flush water at the surface, which mobilizes and transports chromium as it migrates downward to the water table. Once the chromium reaches the water table, it is hydraulically contained, extracted, and treated through pump and treat operations. The efficacy of soil flushing is directly related to the volume of clean water that infiltrates through contaminated soils. Therefore, performance monitoring requires and understanding of flush water migration through the vadose zone. It is challenging to comprehensively assess soil flushing performance via borehole access due to the limited volume of investigation afforded by a given wellbore. As an alternative, 3D time-lapse electrical resistivity tomography (ERT) was tested as a method of monitoring the distribution of flush water over time within the vadose zone. ERT is a method of imaging the bulk electrical conductivity of the subsurface, which is highly dependent on water saturation levels in unconsolidated and unsaturated sediments. Thus, the timing and location of changes in bulk conductivity caused by soil flushing can be used to infer flush water migration pathways. In this report we present results of 3D time-lapse ERT imaging during two separate soil flushing campaigns conducted during the spring and summer months of 2022 and 2023. Results show generally that: 1) Pit backfill materials appear to nominally have larger permeability than native soils. Consequently, the boundary between pit backfill and native soil had a significant impact on flush water migration, causing some flush water to migrate along the pit boundary to the bottom of the pit. 2) Non-uniform flows, likely caused by variations in hydrogeologic properties, developed in the pit backfill materials, resulting in uneven flush water distribution on the southern margin of the soil flushing zone. 3) Redistribution of water at the interface between backfill materials and Hanford formation materials likely facilitated elevated and uniform distribution of flush water within native soils beneath the deeper parts of the pit boundary beneath the center of the flush zone, which presumably overlie soils with elevated chromium contamination. These areas appear to have been infiltrated by higher volumes of flush water than the northern and southern margins of the flush zone. 4) In comparison to 2022, high flush water application rates significantly improved flush water distribution throughout the target flushing zone. 5) Imaging resolution was limited to a depth of approximate 20 meters below the land surface, due primarily to limitations on the lateral extent of the surface ERT array. The ~10 m region of the vadose zone between approximately 130 meters elevation and the water table at approximately 120 meters elevation was unresolved.

100 Area↗

Evaluation of Electrical Resistivity Tomography to Monitor the Transport of Past Releases Beneath Tank Farms

Underground storage tanks at the Hanford Site, in southeastern Washington State, hold radioactive waste generated from four decades of plutonium production. The 149 single-shell tanks and the 28 double-shell tanks have all exceeded their initial design life of approximately 25 years. At least 67 tanks are assumed to have leaked in the past, resulting in radioactive releases into the vadose zone. Gamma ray logging within dry monitoring wells is currently the primary method for tracking the migration of leaked tank waste through the vadose zone. While this approach provides an accurate assessment of radioactive contamination, that information is only provided near (within ~1m) the borehole, leaving most of the vadose zone unmonitored, particularly the important region directly beneath the tank. This report describes a numerical study that investigates the feasibility and performance of time-lapse 3D electrical resistivity tomography (ERT) for long-term monitoring of a hypothetical tank waste location and migration through the vadose zone. ERT is a method of remotely imaging the bulk electrical conductivity (EC) of the subsurface, which is significantly impacted by the presence of conductive solid and liquid tank waste. The release of liquid tank wastes increases subsurface fluid conductivity and saturation over time, creating a target to use time-lapse ERT for long-term monitoring. Although the presence of metallic infrastructure can cause ERT interference, recent advancements in ERT data processing enable the deleterious effects of buried metallic infrastructure (e.g. pipes, wellbore casings, tanks) to be removed to better determine the liquid tank waste migration over time. Three hypothetical realistic scenarios were simulated in the ERT evaluation. The first two scenarios assume the same leak amount and rate (i.e., between 1/1/1951 and 12/31/1951 at the rate of 347 m 3 per year) but different leaky tanks. Scenario 1 assumes leaks under tank B-102, which is located on the edge of the B-tank farm and surrounded by a few metallic infrastructure including cased pipes/wells/tanks. Scenario 2 assumes leaks under tank B-108, which is located near the center of the B-tank farm and surrounded by larger amount of metallic infrastructure than B-102. Scenario 3 assumes the same metallic infrastructure as B-102, with a more recent contaminant leak that was simulated to have occurred between 1/1/2018 and 12/31/2023 at a rate of 1.89 m 3 per year. The leak time in Scenarios 1 and 2 corresponds to a historical overfill event in 1951 and Scenario 3 corresponds to a recent found tank leak in 2019. In each scenario, a “true” bulk EC model vs. time reflecting contaminant migration was generated. ERT data was simulated from these “true” bulk EC models and a time-lapse ERT inversion produced “imaged” bulk EC vs. time. Three electrode configurations in two, four and eight boreholes surrounding the leak tank were used in the ERT simulations in each scenario. These borehole configurations were considered logistically feasible and cost-effective for monitoring. The hypothetical ERT boreholes are assumed to have non-metallic casing. By comparing the “imaged” bulk EC with the “true” bulk EC, it was demonstrated that the three configurations of wells used (two, four, and eight wells) were able to successfully monitor the migration of tank leaks through the vadose zone, with bulk EC resolution increasing with the number of down borehole ERT arrays for all scenarios. Therefore, the use of eight boreholes to perform ERT monitoring beneath the tanks provided the best spatiotemporal information.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Machine learning for improved current-density reconstruction from two-dimensional vector magnetic images

The reconstruction of electrical current densities from magnetic field measurements is an important technique with applications in materials science, circuit design, quality control, plasma physics, and biology. Analytic reconstruction methods exist for planar currents, but break down in the presence of high-spatial-frequency noise or large standoff distance, restricting the types of systems that can be studied. Here, we demonstrate the use of a deep convolutional neural network for current density reconstruction from two-dimensional images of vector magnetic fields acquired by a quantum diamond microscope . Trained network performance significantly exceeds analytic reconstruction for data with high noise or large standoff distances. This machine learning technique can perform quality inversions on lower-signal-to-noise-ratio data, significantly reducing the data collection time and permitting reconstructions of weaker and three-dimensional current sources. Published by the American Physical Society 2025

Reed, Niko R. (ORCID:0009000305222403)↗

Design and fabrication of an experimental image forming light modulator

Image forming light modulator transforms electrical signal representation of two dimensional image into optical transparency. All major assemblies are easily demounted for convenience in adapting modulator to other operating modes with different modulation-media. High-speed vacuum pump is incorporated into modulator housing to help reach required operating pressure.

Shackelford, R. G.↗

Emergent electric field induced by dissipative sliding dynamics of domain walls in a Weyl magnet

The dynamic motion of topological defects in magnets induces an emergent electric field, as exemplified by the continuous flow of skyrmion vortices. However, the electrodynamics underlying this emergent field remains poorly understood. In this context, magnetic domain walls—one-dimensional topological defects with two collective modes, sliding and spin-tilt—offer a promising platform for exploration. Here we demonstrate that the dissipative motion of domain walls under oscillatory current excitation generates an emergent electric field. We image domain patterns and quantify the domain-wall length under applied magnetic fields in mesoscopic devices based on the magnetic Weyl semimetal NdAlSi. These devices exhibit exceptionally strong domain-wall scattering and a pronounced emergent electric field, as observed in the imaginary component of the complex impedance. Spin dynamics simulations reveal that domain-wall sliding dominates over spin-tilting, in which the phase delay of the domain-wall motion with respect to the driving force impacts the emergent electric field. Our findings establish domain-wall dynamics as a platform for studying emergent electromagnetic fields and motivate further investigations of the coupled motion of magnetic solitons and conduction electrons.

Yamada, Rinsuke [The University of Tokyo, Japan]↗

Feld-induced modulation of two-dimensional electron gas at LaAlO 3 /SrTiO 3 interface by polar distortion of LaAlO 3

Since the discovery of two-dimensional electron gas at the LaAlO 3 /SrTiO 3 interface, its intriguing physical properties have garnered significant interests for device applications. Yet, understanding its response to electrical stimuli remains incomplete. Our in-situ transmission electron microscopy analysis of a LaAlO 3 /SrTiO 3 two-dimensional electron gas device under electrical bias reveals key insights. Inline electron holography visualized the field-induced modulation of two-dimensional electron gas at the interface, while electron energy loss spectroscopy showed negligible electromigration of oxygen vacancies. Instead, atom-resolved imaging indicated that electric fields trigger polar distortion in the LaAlO 3 layer, affecting two-dimensional electron gas modulation. This study refutes the previously hypothesized role of oxygen vacancies, underscoring the lattice flexibility of LaAlO 3 and its varied polar distortions under electric fields as central to two-dimensional electron gas dynamics. These findings open pathways for advanced oxide nanoelectronics, exploiting the interplay of polar and nonpolar distortions in LaAlO 3 .

36 MATERIALS SCIENCE↗

Electron-optic limitations on image resolution

Various approaches are considered to the solution of the electron-optical problem of designing an image tube configuration. Emphasis is placed on the method of computer design, and an illustration is given in which the technique is used in the design of an 80-mm image tube with a zoom capability of 3:1. The solutions are discussed to such problems as image distortion, magnification, and electron bundles striking the zoom electrode. Three types of an electron-optical configuration are examined for the electron-optic limitations to resolution: (1) the proximity image tube, (2) the magnetic-type image tube having uniform electric and magnetic fields, and (3) the electrostatic-type image tube such as the 80-mm zoom tube.

Engstrom, R. W.↗

Application of the high resolution return beam vidicon

The Return Beam Vidicon (RBV) is a high-performance electronic image sensor and electrical storage component. It can accept continuous or discrete exposures. Information can be read out with a single scan or with many repetitive scans for either signal processing or display. Resolution capability is 10,000 TV lines/height, and at 100 lp/mm, performance matches or exceeds that of film, particularly with low-contrast imagery. Electronic zoom can be employed effectively for image magnification and data compression. The high performance and flexibility of the RBV permit wide application in systems for reconnaissance, scan conversion, information storage and retrieval, and automatic inspection and test. This paper summarizes the characteristics and performance parameters of the RBV and cites examples of feasible applications.

Cantella, M. J.↗

Dynamics of the water-plasma interface in various discharge modes of atmospheric-pressure plasmas

This paper presents an experimental study of the dynamics of the water-plasma interface during the interaction high-voltage (HV) atmospheric pressure discharge with the water surface. Under the influence of the voltage applied to the pin type electrode, discharges are formed at the air layer between the sharp-tip HV electrode and deionized water. Three discharge regimes were identified from synchronized electrical waveforms and imaging: (i) a weak linear regime at 3–10.6 kV, (ii) a branching streamer regime at the maximum applied voltage of 12.6 kV, and (iii) a continuous arc-like regime occurring during the transition to lower voltage and higher current (e.g., U ≈ 3.2 kV, I ≈ 4.07 mA). High-speed shadowgraph images showed a symmetric interfacial cavity whose depth increased nonlinearly with voltage from h 0 ≈ 0.1 mm at 3 kV to h 0 ≈ 2.7 mm at 10.6 kV, reaching a maximum depth of h 0 ≈ 5.9 mm at 12.6 kV, while the cavity disappeared in the continuous-channel regime and was replaced by outward-propagating wave-like motion. The deformation of the water surface during the discharge-water interaction is governed by the balance between electric field forces, surface tension, gravitational forces, and electrohydrodynamic forces, whose relative contributions vary with the applied voltage. This effect was explained by quantitatively estimating the magnitudes of the acting forces and establishing the force balance. Optical emission spectroscopy in the continuous-channel regime indicated air plasma signatures and yielded a gas temperature of approximately 400 K, while prolonged operation (≈ 20 min) increased the water temperature to ~ 70 °C, reduced the water-layer thickness from 6 mm to 3 mm, and decreased pH from 7 to 4. These regime-resolved, quantitative results clarify how the dominant interfacial forcing shifts with discharge mode and provide a mechanistic basis for controlling plasma-water interactions in atmospheric-pressure applications.

atmospheric pressure plasma↗

The Altus Cumulus Electrification Study (ACES): A UAV-Based Science Demonstration

The Altus Cumulus Electrification Study (ACES) is an unmanned aerial vehicle (UAV)- based project that investigated thunderstorms in the vicinity of the Florida Everglades in August 2002. ACES was conducted to investigate storm electrical activity and its relationship to storm morphology, and to validate satellite-based lightning measurements. In addition, as part of the NASA sponsored UAV-based science demonstration program, this project provided a scientifically useful demonstration of the utility and promise of UAV platforms for Earth science and applications observations. ACES employed the Altus II aircraft, built by General Atomics - Aeronautical Systems, Inc. Key science objectives simultaneously addressed by ACES are to: (1) investigate lightning-storm relationships, (2) study storm electrical budgets, and provide Lightning Imaging Sensor validation. The ACES payload included electrical, magnetic, and optical sensors to remotely characterize the lightning activity and the electrical environment within and around thunderstorms. ACES contributed important electrical and optical measurements not available from other sources. Also, the high altitude vantage point of the UAV observing platform (up to 55,000 feet) provided cloud-top perspective. By taking advantage of its slow flight speed (70 to 100 knots), long endurance, and high altitude flight, the Altus was flown near, and when possible, over (but never into) thunderstorms for long periods of time that allowed investigations to be conducted over entire storm life cycles. An innovative real time weather system was used to identify and vector the aircraft to selected thunderstorms and safely fly around these storms, while, at the same time monitor the weather near our base of operations. In addition, concurrent ground-based observations that included radar (Miami and Key West WSRBD, NASA NPOL), satellite imagery, and lightning (NALDN and Los Alamos EDOT) enable the UAV measurements to be more completely interpreted and evaluated in the context of the thunderstorm structure, evolution, and environment.

Blakeslee, R. J.↗

A preliminary characterization of applied-field MPD thruster plumes

Electric probes, quantitative imaging, and emission spectroscopy were used to study the plume characteristics of applied field magnetohydrodynamic thrusters. The measurements showed that the applied magnetic field plays the dominant role in establishing the plume structure, followed in importance by the cathode geometry and propellant. The anode radius had no measurable impact on the plume characteristics. For all cases studied the plume was highly ionized, though spectral lines of neutral species were always present. Centerline electron densities and temperatures ranged from 2 times 10 (exp 18) to 8 times 10 (exp 18) m(exp -3) and from 7500 to 20,000 K, respectively. The plume was strongly confined by the magnetic field, with radial density gradients increasing monotonically with applied field strength. Plasma potential measurements show a strong effect of the magnetic field on the electrical conductivity and indicate the presence of radial current conduction in the plume.

Myers, Roger M.↗