Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrical power system simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

An Evaluation of Co-Simulation for Modeling Coupled Natural Gas and Electricity Networks

Reliance on natural gas for power generation has increased the coupling between gas and power networks. While this coupling can bring operational and economic benefits, it can also yield challenges, as the constraints in one system can impact the other. Co-simulation can capture the constraints and interactions between these systems, but so far, there has been limited comparison of co-simulation results to those of an integrated model. In this work, we develop a new co-simulation framework using the HELICS platform and the SAInt tool for modeling transient gas and AC optimal power flow. We evaluate this co-simulation framework against a fully integrated version of the SAInt power and gas simulators, thus providing a benchmarking of the co-simulation approach. We compare results across the two approaches for two test networks and a network representing the Belgian power and gas networks, testing both normal operating conditions and cases with compressor disruptions. In each of the cases tested, we find nearly identical results from the two approaches across various metrics of interest, such as nodal pressure, gas flow rates, and active power generation. This alignment suggests that co-simulation can yield comparable results to fully integrated models for modeling coupled gas and electricity networks.

03 NATURAL GAS↗

System Modeling and Simulation of In-Stream Hydrokinetic Turbines for Power Management and Control

Electricity generation from moving currents without using dams (i.e., in-stream hydrokinetic electricity) has the potential to introduce multiple GW of renewable power to U.S. grids. Here this study evaluates a control system designed to regulate the generator rotor rate (rpm) to improve power production from in-stream hydrokinetic turbines. The control algorithm is evaluated using numerical models of both a rigidly mounted tidal turbine (TT) and a moored ocean current turbine (OCT) coupled to an induction electric machine model. The moored simulation utilizes an innovative approach for coupling a multiple degrees-of-freedom (DOF) nonlinear hydrodynamic/mechanical turbine model with a nonlinear electromechanical generator model. Based on the turbine torque-speed characteristic, as well as the asynchronous machine features, a proportional–integral (PI) controller is used to generate a correction term for the frequency of the three-phase sinusoidal voltages that are supplied to the asynchronous generator. The speed control of the induction generator through the supply frequency is accomplished by a simplified voltage source inverter (VSI). The simplified VSI consists of control voltage sources (CVSs), while the comparison with a real VSI using diodes and transistors, which are controlled by pulse width modulation (PWM) technique, is also presented. Simulations are used to evaluate the developed algorithms showing that rpm fluctuations are around 0.02 for a tidal turbine operating in a wave field with a 6 m significant wave height and around 0.005 for a moored ocean current turbine operating in a wave field with a 2 m significant wave height.

16 TIDAL AND WAVE POWER↗

A Multiphase, Modular, Bidirectional, Triple-Voltage DC-DC Converter Power Systems

Electrical power systems in future hybrid and fuel cell vehicles may employ three voltage [14 V, 42 V, and high voltage (HV)] nets. These will be necessary to accommodate existing 14-V loads as well as efficiently handle new heavy loads at the 42-V net and a traction drive on the HV bus. A low-cost DC-DC converter was proposed for connecting the three voltage nets. It minimizes the number of switches and their associated gate driver components by using two half-bridges and a high-frequency transformer. Another salient feature is that the half bridge on the 42-V bus is also utilized to provide the 14-V bus by operating at duty ratios around an atypical value of 1/3. Moreover, it makes use of the parasitic capacitance of the switches and the transformer leakage inductance for soft switching. The use of half bridges makes the topology well suited for interleaved multiphase modular configurations as a means to increase the power level because the capacitor legs can be shared. This paper presents simulation and experimental results on an interleaved two-phase arrangement rated at 4.5 kW. Also discussed are the benefits of operating with an atypical duty ratio on the transformer and a preferred multiphase configuration to minimize capacitor ripple currents.

30 DIRECT ENERGY CONVERSION↗

Impacts of Using Distributed Energy Resources to Reduce Peak Loads in Vermont

To help the United States develop a modern electricity grid that provides reliable power from multiple resources as well as resiliency under extreme conditions, the U.S. Department of Energy (DOE) is leading the Grid Modernization Initiative (GMI) to help shape the future of the nation's grid. Under the GMI, DOE funded the Vermont Regional Initiative project to provide the technical support and analysis to utilities that need to mitigate possible impacts of increasing renewable generation required by statewide goals. Advanced control of distributed energy resources (DER) can both support higher penetrations of renewable energy by balancing controllable loads to wind and photovoltaic (PV) solar generation and reduce peak demand by shedding noncritical loads. This work focuses on the latter. This document reports on an experiment that evaluated and quantified the potential benefits and impacts of reducing the peak load through demand response (DR) using centrally controllable electric water heaters (EWHs) and batteries on two Green Mountain Power (GMP) feeders. The experiment simulated various hypothetical scenarios that varied the number of controllable EWHs, the amount of distributed PV systems, and the number of distributed residential batteries. The control schemes were designed with several objectives. For the first objective, the primary simulations focused on reducing the load during the independent system operator (ISO) peak when capacity charges were the primary concern. The second objective was to mitigate DR rebound to avoid new peak loads and high ramp rates. The final objective was to minimize customers' discomfort, which is defined by the lack of hot water when it is needed. We performed the simulations using the National Renewable Energy Laboratory's (NREL's) Integrated Energy System Model (IESM) because it can simulate both electric power distribution feeder and appliance end use performance and it includes the ability to simulate multiple control strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hybrid Solid Oxide Fuel Cell/Gas Turbine Model Development for Electric Aviation

A thermodynamic model was developed and validated to analyze a high-performance solid oxide fuel cell and gas turbine (SOFC-GT) hybrid power system for electric aviation. This study used a process simulation software package (ProMax) to study the role of SOFC design and operation on the feasibility and performance of the hybrid system. Standard modules, including compressor, turbine, heat exchanger, reforming reactor, and combustor were used from the ProMax tool suite while a custom module was created to simulate the SOFC stack. The model used an SOFC test data set as an input. Additional SOFC stack performance effects, such as pressure, temperature, and utilization of air and fuel, were added from open source data. System performance predictors were SOFC specific power, fuel-to-electricity conversion efficiency, and hybrid system efficiency. Using these input data and predictors, a static thermodynamic performance model was created that can be modified for different system configurations and operating conditions. Prior to creating the final aircraft performance model, initial demonstration models were developed to validate output results. We used the NASA SOFC model as a benchmark, which was created with their Numerical Propulsion System Simulator (NPSS) software framework. Our output results matched within 1% of both the NASA model and open source SOFC performance data. With confidence gained in the accuracy of this model, a 1-MW SOFC-GT hybrid power system was constructed for an aircraft propulsion concept. Overall hybrid system efficiencies of > 75% FTE were observed during standard 36,000 feet cruise flight conditions.

30 DIRECT ENERGY CONVERSION↗

E-transit-bench: simulation platform for analyzing electric public transit bus fleet operations

When electrified transit systems make grid aware choices, improved social welfare is achieved by reducing grid stress, reducing system loss, and minimizing power quality issues. Electrifying transit fleet has numerous challenges like non availability of buses during charging, varying charging costs and so on, that are related the electric grid behavior. However, transit systems do not have access to the information about the co-evolution of the grid's power flow and therefore cannot account for the power grid's needs in its day-to-day operation. In this paper we propose a framework of transportation-grid co-simulation, analyzing the spatio-temporal interaction between the transit operations with electric buses and the power distribution grid. Real-world data for a day's traffic from Chattanooga city's transit system is simulated in SUMO and integrated with a realistic distribution grid simulation (using GridLAB-D) to understand the grid impact due to transit electrification. Charging information is obtained from the transportation simulation to feed into grid simulation to assess the impact of charging. We also discuss the impact to the grid with higher degree of transit electrification that further necessitates such an integrated transportation-grid co-simulation to operate the integrated system optimally. Our future work includes extending the platform for optimizing the charging and trip assignment operations.

Sen, Rishav↗

Power System Operational Impacts of Electric Vehicle Dynamic Wireless Charging

The electrification of the transportation sector poses an opportunity for reducing greenhouse gas (GHG) emissions from passenger vehicles. Electric vehicle (EV) charging through dynamic wireless power transfer (DWPT), known as roadway electrification, could shift EV demand profiles to better coincide with renewable electricity generation. However, this would be a very large new load and few studies evaluate the regional impacts of DWPT charging in a power transmission system. This paper defines methods that address dataset generation for passenger vehicle trips and models to evaluate regional impacts for this emerging technology. Household vehicle miles traveled (VMT) data form localized EV demand profiles through discrete-event simulation. This data serves as exogenous inputs for a Production Cost Model (PCM) of a synthetic transmission system based on the Electric Reliability Council of Texas's (ERCOT) network. EV charging methods are compared for both a 2018 baseline generation mixture and a high-renewable generation case incorporating 20 GW of installed solar photovoltaic (PV) capacity. The PCM employs unit commitment and economic dispatch (UC&ED) models to compare financial, environmental, and grid reliability impacts from EV charging across passenger EV adoption levels. In-transit charging could reduce grid operational costs by as much as 1.49%, with up to $13.7B saved in annual vehicle operational costs for consumers compared to gas-powered vehicles. Health impacts analysis from power plant and vehicle tailpipe emissions from this study show net health benefits increase by 40% for in-transit charging coupled with high renewable generation. Renewable resources provide an avenue for cost-effective in-transit charging with reduced emissions. The combination of dataset generation and open-source power system modeling establish a foundation for the holistic evaluation of regional DWPT impacts.

dynamic wireless power transfer↗

Trans-oceanic Remote Power Hardware-in-the-Loop: Multi-site Hardware, Integrated Controller, and Electric Network Co-simulation

Electric system operators are increasingly concerned with the potential system-wide impacts of the large-scale integration of distributed energy resources (DERs) including voltage control, protection coordination, and equipment wear. This prompts a need for new simulation techniques that can simultaneously capture all the components of these large integrated smart grid systems. This paper describes a novel platform that combines three emerging research areas: power systems co-simulation, power hardware in the loop (PHIL) simulation, and lab-lab links. The platform is distributed, real-time capable, allows for easy internet-based connection from geographically-dispersed participants, and is software platform agnostic. We demonstrate its utility by studying real-time PHIL co-simulation of coordinated solar PV firming control of two inverters connected in multiple electric distribution network models, prototypical of U.S. and Australian systems. Here, the novel trans-pacific closed-loop system simulation was conducted in real-time using a power network simulator and physical PV/battery inverter at power at the National Renewable Energy Laboratory in Golden, CO, USA and a physical PV inverter at power at the Commonwealth Scientific and Industrial Research Organisation's Energy Centre in Newcastle, NSW, Australia. This capability enables smart grid researchers throughout the world to leverage their unique simulation capabilities for multi-site collaborations that can effectively simulate and validate emerging smart grid technology solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance of Energy Storage with Nuclear and Renewable Power Systems

Nuclear power represents a traditional baseload power component to the grid, while renewables output variable amounts of power at unpredictable times. Nuclear and renewable energy integration (NREI) systems have previously been explored as valuable additions to the existing power grid. Energy storage systems can allow power plants to store energy mechanically using pumped hydro or compressed air, thermally using liquid salt or steam accumulators, or chemically with batteries. The addition of energy storage to NREI systems can allow for the discharge of electricity to adjust to demands placed on the grid. The allocation of energy to adjust to grid demand is explored through a historical 8,760-hour analysis including nuclear, wind, and solar NREI systems with energy storage. The operation of storage systems is compared through simulations of different storage and discharge parameters based off the maximum daily grid demands, and hourly electricity prices. The overall profitability of storage systems is determined by comparing simulation results for the overall net revenue increases exceeding storage efficiency losses. Several NREI systems have increased the value of electricity for both solar PV and wind energy, in combination with nuclear power. Optimization of these systems is developed using MATLAB code and the simulations of the most profitable results are explored.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

National power grid simulation capability : need and issues

On December 9 and 10, 2008, the Department of Homeland Security (DHS) Science and Technology Directorate sponsored a national workshop at Argonne National Laboratory to explore the need for a comprehensive modeling and simulation capability for the national electric power grid system. The workshop brought together leading electric power grid experts from federal agencies, the national laboratories, and academia to discuss the current state of power grid science and engineering and to assess if important challenges are being met. The workshop helped delineate gaps between grid needs and current capabilities and identify issues that must be addressed if a solution is to be implemented. This report is a result of the workshop and highlights power grid modeling and simulation needs, the barriers that must be overcome to address them, and the benefits of a national power grid simulation capability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

GridLAB-D: An Agent-Based Simulation Framework for Smart Grids

Simulation of smart grid technologies requires a fundamentally new approach to integrated modeling of power systems, energy markets, building technologies, and the plethora of other resources and assets that are becoming part of modern electricity production, delivery, and consumption systems. As a result, the US Department of Energy’s Office of Electricity commissioned the development of a new type of power system simulation tool called GridLAB-D that uses an agent-based approach to simulating smart grids. This paper presents the numerical methods and approach to time-series simulation used by GridLAB-D and reviews applications in power system studies, market design, building control system design, and integration of wind power in a smart grid.

agent↗

Analyzing the Impact of Solar Power on Multi-Hourly Thermal Generator Ramping

Solar power generation, unlike conventional forms of electricity generation, has higher variability and uncertainty in its output because solar plant output is strongly impacted by weather. As the penetration rate of solar capacity increases, grid operators are increasingly concerned about accommodating the increased variability and uncertainty that solar power provides. This paper illustrates the impacts of increasing solar power penetration on the ramping of conventional electricity generators by simulating the operation of the Independent System Operator -- New England power system. A production cost model was used to simulate the power system under five different scenarios, one without solar power and four with increasing solar power penetrations up to 18%, in terms of annual energy. The impact of solar power is analyzed on six different temporal intervals, including hourly and multi-hourly (2- to 6-hour) ramping. The results show how the integration of solar power increases the 1- to 6-hour ramping events of the net load (electric load minus solar power). The study also analyzes the impact of solar power on the distribution of multi-hourly ramping events of fossil-fueled generators and shows increasing 1- to 6-hour ramping events for all different generators. Generators with higher ramp rates such as gas and oil turbine and internal combustion engine generators increased their ramping events by 200% to 280%. For other generator types--including gas combined-cycle generators, coal steam turbine generators, and gas and oil steam turbine generators--more and higher ramping events occurred as well for higher solar power penetration levels.

14 SOLAR ENERGY↗

Power Grid Simulation Testbed for Transactive Energy Management Systems

To effectively engage demand-side and distributed energy resources (DERs) for dynamically maintaining the electric power balance, the challenges of controlling and coordinating building equipment and DERs on a large scale must be overcome. Although several control techniques have been proposed in the literature, a significant obstacle to applying these techniques in practice is having access to an effective testing platform. Performing tests at scale using real equipment is impractical, so simulation offers the only viable route to developmental testing at scales of practical interest. Existing power-grid testbeds are unable to model individual residential end-use devices for developing detailed control formulations for responsive loads and DERs. Furthermore, they cannot simulate the control and communications at subminute timescales. To address these issues, this paper presents a novel power-grid simulation testbed for transactive energy management systems. Detailed models of primary home appliances (e.g., heating and cooling systems, water heaters, photovoltaic panels, energy storage systems) are provided to simulate realistic load behaviors in response to environmental parameters and control commands. The proposed testbed incorporates software as it will be deployed, and enables deployable software to interact with various building equipment models for end-to-end performance evaluation at scale.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Smart Grid - Transforming Power System Operations

Abstract—Electric power systems are entering a new realm of operations. Large amounts of variable generation tax our ability to reliably operate the system. Couple this with a greater reliance on the electricity network to serve consumer demand that is likely to rise significantly even as we drive for greater efficiency. Trade-offs between energy and environmental needs will be constantly negotiated, while a reliable supply of electricity needs even greater assurance in a world where threats of disruption have risen. Smart grid capabilities are being proposed to help address the challenges confronting system operations. This paper reviews the impact of smart grid functionality on transforming power system operations. It explores models for distributed energy resources (DER – generation, storage, and load) that are appearing on the system. It reviews the evolving nature of electricity markets to deal with this complexity and a change of emphasis on signals from these markets to affect power system control. Smart grid capabilities will also impact reliable operations, while cyber security issues must be addressed as a culture change that influences all system design, implementation, and maintenance. Lastly, the paper explores significant questions for further research and the need for a simulation environment that supports such investigation and informs deployments to mitigate operational issues as they arise.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling of Microgrid for Critical Data Center Applications

As part of continuing efforts to develop support, understanding, and infrastructure of data center integration onto the electric grid, our work aims to model and analyze the behavior of data center loads in a microgrid power system. Our model consists of renewable energy sources, batteries, and a nuclear reactor-steam Rankine cycle to power data center loads. The simulation studies investigate the electrical behavior of the microgrid system to assess its ability in supporting large data center electrical demands.

14 - SOLAR ENERGY↗

Design analysis and computer-aided performance evaluation of shuttle orbiter electrical power system. Volume 2: SYSTID user's guide

The manual for the use of the computer program SYSTID under the Univac operating system is presented. The computer program is used in the simulation and evaluation of the space shuttle orbiter electric power supply. The models described in the handbook are those which were available in the original versions of SYSTID. The subjects discussed are: (1) program description, (2) input language, (3) node typing, (4) problem submission, and (5) basic and power system SYSTID libraries.

Source record↗

Development and Integration of a Thermal Management Simulation for a Quadrotor Parallel Hybrid Propulsion System

This paper details the development of a propulsion system simulation for a six-passenger parallel hybrid quadrotor and utilizes the Numerical Propulsion System Simulation (NPSS) along with the NPSS Power System Library as the development environment. This simulation integrates an engine power plant with an electrical generation and distribution system and includes the required thermal management system. The thermal management system is comprised of liquid cooling loops that reject the heat load through air to coolant heat exchangers and utilizes a map-based performance estimation method. This method is developed within NPSS and detailed in this paper. The full system model is designed to predict system weight, range, and performance through a proposed mission profile. Results of the paper show an all-engine system maintains the best range, while a mostly electric system that utilizes an engine as a backup or a conditional power contributor offers range benefit.

Vertical lift and take off vehicle↗