Search NASASearch

SEARCH · Search NASA

Results for “Electrical properties and parameters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,672 records · Page 6

Contrasting structural reversibility and magnetic correlations in isostructural honeycomb magnets CrCl3 and 𝛼−RuCl3

We report a comparative neutron single crystal diffraction study of the structural and magnetic properties of layered halides CrCl3 and 𝛼−RuCl3. They host a honeycomb arrangement of transition metal ions with distinct electronic configurations and undergo a first-order structural transition between high-temperature 𝐶⁢2/𝑚 and low-temperature 𝑅⁢‾‾‾3. Both compounds show a step-like change in the 𝑐-lattice parameter across the structure transition. In contrast, the in-plane lattice response is quite different: 𝛼−RuCl3 exhibits an abrupt hysteretic change across the transition accompanied by progressive crystalline degradation upon thermal cycling, whereas CrCl3 shows a smooth in-plane lattice evolution and remains structurally robust. Magnetically, CrCl3 orders into an A-type antiferromagnetic structure at 𝑇𝑁=14 K and exhibits pronounced diffuse magnetic scattering extending up to about 40 K. 𝛼−RuCl3 shows no observable magnetic diffuse scattering above its zigzag antiferromagnetic ordering temperature 𝑇𝑁=7.6 K. These results suggest that the contrasting structural responses arise from an interplay between interlayer sliding energetics, stacking-strain coupling, and elastic accommodation of the stacking transition. The distinct chemical bonding and electronic configurations of the two compounds provide a microscopic basis for their different lattice responses to the structure transition and magnetic correlations.

Morgan, Zachary [ORNL] (ORCID:0000000243625911)

Crack‐Free Single‐Crystalline LiNiO 2 for High Energy Density All‐Solid‐State Batteries

Abstract Single‐crystalline layered oxide (LiNi 1‐ x ‐ y Mn x Co y O 2 ) cathodes have been found to exhibit exceptional electrochemical properties when coupled with various inorganic solid electrolytes (ISEs) in all‐solid‐state batteries (ASSBs). Their advantages stem from the robust morphological integrity with the absence of grain boundaries and the high electrochemical oxidative stability. Here, ASSBs featuring single‐crystalline LiNiO 2 (LNO) with the highest Ni content are reported, offering a high theoretical specific capacity of 275 mAh g ‐1 alongside a high average discharge voltage (3.7 V vs Li + /Li). Through a careful investigation, it is demonstrated that micron‐sized single‐crystalline LNO (µSC‐LNO) composite cathodes with a halide ISE exhibit a high initial discharge capacity of 205 mAh g ‐1 with an outstanding cycle performance over 200 cycles in room‐temperature ASSBs. The significance of engineering parameters is emphasized, such as particle size and specific density, in promoting a homogeneous and fast Li + transport within the composite cathodes. Furthermore, the formation of undesirable interphase between the halide ISE in the cathode and sulfide ISE separator is elucidated, which may be a critical factor impeding long‐term cyclability of ASSBs. This work provides insights into the design of composite cathodes for high‐energy‐density ASSBs.

Chemistry

Multireference diffusion Monte Carlo reaches 2D materials

Abstract Quantum confinement in 2D materials strongly enhances electronic correlation effects. Therefore, predicting the properties of these unique materials, with both a high level of accuracy and computational efficiency, without relying on adjustable parameters or functionals, remains an outstanding theoretical challenge. The majority of theoretical studies are based on the approximations of density functional theory (DFT). The reliability of DFT predictions are heavily dependent on the choice of an approximated exchange-correlation functional. Here, we estimate the magnitude of impact of correlation on the total energy for the quintessential 2D material, graphene, by performing and comparing state-of-the-art selected CI and quantum Monte Carlo extrapolated calculations for a single unit cell at the$$\Gamma$$point. We demonstrate that Self-Healing Diffusion Monte Carlo (SHDMC) obtains a very compact, but high-quality wavefunction for this system that lacks the strong basis set dependence displayed by state of the art quantum chemistry methods. The SHDMC wavefunction is of higher quality compared to that obtained from sCI, in the same orbital basis, while being$$\sim$$ 1000 times smaller in terms of determinant count compared to sCI. We also demonstrate that extrapolating SHDMC results to the infinite determinant limit compares extremely well with complete basis set extrapolated sCI. Our work paves the way for future validation of SHDMC applied to challenging 2D materials.

Science & Technology - Other Topics

Development of large-scale, 3D Printed high temperature ceramic material

Through this collaborative effort, a new 3D printing platform for ceramics called laser-induced slip casting (LIS) was explored and developed for improving the processing and manufacture of silicon carbide (SiC), a high temperature ceramic material. This method prints layers of ceramic slips/slurries with subsequent selective-laser heating to dry each layer to build a 3D structure. The completed and dried part is then sintered. This manufacturing process is inherently lower cost than alternative ceramic printing methods such as binder jet technology or stereolithography when it comes to the feedstock material but is more expensive than robocasting or direct ink writing. However, it has the potential to make more controlled parts with less defects compared to robocasting. The largest cost is the heating source for the printer. With this technique, there is potential to make large ceramic parts in a near-net shape. Further, there is no known commercial manufacturing of 3D printed ceramics that creates a large range of different high-density ceramics at large scale. The goals and outcomes for the development of the new printing technology were: 1) assessing the technology with alumina by characterizing coupons, 2) printing and sintering of silicon carbide (SiC), and 3) characterization and properties testing of materials printed and a scale-up of SiC part(s). Through this collaborative project, it was sought to provide the best solution to achieving highly dense and near-net shaped ceramic parts at large scale and reduced cost. The goal was to produce high density sintered materials for applications in defense, energy generating systems, armor, and wear parts using 3D printing methods. Variables including powder particle sizes, dispersant molecular weights (MWs), binders, printing parameters, and post processing were explored as well as the characterization of the physical properties (add specifics here).

36 MATERIALS SCIENCE

Mitigating electrochemical degradation in CsPbBr{sub 3} gamma detectors by organic and inorganic encapsulation.

CsPbBr3 perovskite semiconductors have emerged as a leading candidate for nextgeneration radiation detectors because of their exceptional charge transport properties, defect tolerance, and record-breaking sensitivity and energy resolution. Their long-term stability, however, is hindered by electrode-driven electrochemical decomposition, which is accelerated by moisture- and oxygen-assisted ion migration during operation. Here, we investigated organic and inorganic encapsulation strategies as both environmental barriers and means to suppress interfacial degradation pathways. Atomic layer deposition (ALD) of Al2O3 provided a conformal passivation layer that blocked environmental ingress, suppressed ionic diffusion, reduced leakage current, enhanced energy resolution and expanded the operational electric-field window beyond 5 kV∙cm1 . By contrast, organic encapsulants such as paraffin wax and polystyrene slowed moisture diffusion but did not suppress interfacial reactions, with wax extending stability to over 90 days. These results show that ALD-Al2O3 suppresses dominant interfacial degradation pathways, enabling stable, high-field operation and advancing the practical deployment of CsPbBr3 γ-ray detectors.

Unal, Mustafa

Cation valency in water-in-salt electrolytes alters the short- and long-range structure of the electrical double layer

Highly concentrated aqueous electrolytes (termed water-in-salt electrolytes, WiSEs) at solid-liquid interfaces are ubiquitous in myriad applications including biological signaling, electrosynthesis, and energy storage. This interface, known as the electrical double layer (EDL), has a different structure in WiSEs than in dilute electrolytes. Here, we investigate how divalent salts [zinc bis(trifluoromethylsulfonyl)imide, Zn(TFSI) 2 ], as well as mixtures of mono- and divalent salts [lithium bis(trifluoromethylsulfonyl)imide (LiTFSI) mixed with Zn(TFSI) 2 ], affect the short- and long-range structure of the EDL under confinement using a multimodal combination of scattering, spectroscopy, and surface forces measurements. Raman spectroscopy of bulk electrolytes suggests that the cation is closely associated with the anion regardless of valency. Wide-angle X-ray scattering reveals that all bulk electrolytes form ion clusters; however, the clusters are suppressed with increasing concentration of the divalent ion. To probe the EDL under confinement, we use a Surface Forces Apparatus and demonstrate that the thickness of the adsorbed layer of ions at the interface grows with increasing divalent ion concentration. Multiple interfacial layers form following this adlayer; their thicknesses appear dependent on anion size, rather than cation. Importantly, all electrolytes exhibit very long electrostatic decay lengths that are insensitive to valency. It is likely that in the WiSE regime, electrostatic screening is mediated by the formation of ion clusters rather than individual well-solvated ions. This work contributes to understanding the structure and charge-neutralization mechanism in this class of electrolytes and the interfacial behavior of mixed-electrolyte systems encountered in electrochemistry and biology.

Science & Technology - Other Topics

Electricity Markets and Long-Duration Energy Storage: A Survey of Grid Services and Revenue Streams

Purpose of Review Long Duration Energy Storage (LDES) is increasingly viewed as a potential resource for providing grid services that enhance the stability and flexibility of electricity systems. While some LDES services are integrated into existing market frameworks, traditional mechanisms may not fully account for their operational characteristics, potentially leading to undervaluation. Within this context, this paper reviews the literature and industry practices to assess potential grid services for LDES, evaluates existing compensation mechanisms, and identifies challenges to full market integration. Recent Findings We first review existing literature and identify key grid services unique to LDES, including enhancing grid resilience during extreme weather events, enabling long-term energy shifting, and providing flexible and firm energy in systems with limited dispatchable resources. Here, we also review how LDES services are compensated in current market frameworks and the challenges associated with the full realization of LDES values. Additionally, we summarize market mechanisms for storage technologies across U.S. wholesale markets. We find that some markets are adjusting incentive structures, such as incorporating storage duration in capacity accreditation, to better align with system needs and LDES contributions to the grid. However, further refinements in capacity remuneration and dispatch timeframes may be needed for more effective realization of LDES value. Summary This review evaluates potential grid services for LDES, examines existing compensation mechanisms for LDES technologies, and identifies gaps between these mechanisms and LDES operational characteristics. The review concludes by outlining potential market enhancements for more effective LDES integration and articulating additional research needs to support its efficient participation in future power systems.

Flexible resources

Utility Experience with Inverter Based Resource Impacts on Transmission Protection

High penetration of inverter-based resources (IBR) can adversely affect the transmission protection schemes in the area. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems because the existing system has been designed based on the fault current response of conventional rotating-machine-based generators. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. It includes a broad review of all challenges that system protection has experienced so far with high penetration of IBRs. Key issues have been identified based on a survey of different utility protection engineers. Finally, fault event recordings are shown to demonstrate some actual cases of mis-operations of relays near IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION

Preliminary Evaluation of Joint Electricity-Hydrogen Concept of Operations

An initial thermal power dispatch (TPD) concept of operations was evaluated that couples a nuclear power plant to a nearby hydrogen production plant. GSE Systems’ generic pressurized water reactor full-scope simulator was modified with a TPD model comprised of a thermal power extraction and delivery system. A prototype human-system interface (HSI) was developed to interact with the TPD model and allow participants to execute the basic operating scenarios for normal operations. Four retired operators performed the evaluation, and due to COVID-19 travel restrictions, the original in-person experimental design was restructured to support a remote participator evaluation using a web meeting platform. Data from operator feedback, observations from the research team, and quantitative survey responses revealed that the initial TPD concept of operations is feasible. The operators were comfortable with the engineered system and HSI and could manage it without adverse impacts to reactor power, plant safety, or equipment. Findings are discussed in terms of both the TPD system design and HSI performance.

human factors

Measuring Climate and Water Risk across the Bulk Power System

As climate impacts increase and power systems transition to renewables, planners and operators need insights into climate risks to power generation and infrastructure to ensure reliable decision-making in the short and long-term. We present a standardized, consistent mechanism for utilities and system operators to evaluate the climate- and water-related risks of their current and future grid assets. Using a risk-based approach on the combined outcomes of high-fidelity climate drivers together with water and power system models, we examine the temperature and water availability impacts within the contiguous United States to power system assets at the water basin level in three different time periods and report resulting outcomes on lost capacity across different expansion scenarios and climate models. The results indicate that air temperature has the highest effect on derating. Changes in streamflow do not have a large impact on generation capacity at the national level. Electric sector buildout scenarios each have a unique regional risk profile, depending on the technology mix and total capacity, although risks from high temperatures are significant for both traditional and renewable energy generation. Stakeholders can use this approach to monitor effects of generation capacity losses and potential impacts as climate, generation mix, and infrastructure change.

24 POWER TRANSMISSION AND DISTRIBUTION

Small Co-doping induced magnetic and electrical transitions in single crystal CaF⁢e 0.95 ⁢C⁢o 0.05 ⁢O 3

CaFe⁢O 3 and CaF⁢e 0.95 ⁢C⁢o 0.05 ⁢O 3 single crystals were grown by combing floating-zone method with high oxygen pressure treatment. Both crystals show charge disproportionation of Fe (F⁡e 4+ → F⁡e 3+ + F⁡e 5+ ) accompanied by a metal-to-insulator transition as well as a crystal structural transformation from Pbnm to 𝑃⁢2 1 /𝑛. However, the slight introduction of Co significantly suppresses the critical temperature of charge disproportionation from 290 K in CaFe⁢O 3 to 260 K in CaF⁢e 0.95 ⁢C⁢o 0.05 ⁢O 3 . Different from the single antiferromagnetic phase transition as observed in the polycrystalline CaFe⁢O 3 , two sequential antiferromagnetic transitions are found to occur in these two single crystals with the Néel temperatures around 119 and 112 K for CaFe⁢O 3 crystal and 109 and 98 K for CaF⁢e 0.95 ⁢C⁢o 0.05 ⁢O 3 crystal, respectively. Neutron diffraction illustrates the formation of a spiral antiferromagnetic structure. Moreover, as the temperature further decreases to 65 K, a third magnetic transition accompanied by a second electrical transition is observed in the slightly Co-doped CaF⁢e 0.95 ⁢C⁢o 0.05 ⁢O 3 crystal. In conclusion, first-principles calculations suggest that the introduction of a moderate amount of Co and the peculiar spiral spin texture play an important role in the presence of such new magnetic and electrical transitions.

Xia, Hailiang [Chinese Academy of Sciences (CAS),

POWER ELECTRONICS GRID TIED SYSTEM FINAL REPORT

Across the country, electric utilities are grappling with the persistent hurdles of integrating Distributed Energy Resources (DERs). Managing these assets safely and effectively is a complex endeavor, complicated by varying ownership structures, management philosophies, and the diversity of the technologies themselves. Consequently, the industry has seen a proliferation of bespoke system designs, control strategies, and communication frameworks—forcing utilities to spend significant time and resources developing one-off integration solutions. This project addressed these integration hurdles through a scalable demonstration of intelligent devices designed to coordinate and control diverse resources in low-voltage applications. This concept minimized the need for complex integration by transforming the separate DERs into a dispatchable virtual power plant (VPP) with integrated resiliency functions (called a Node). By collaborating with a utility partner, the project focused on developing rapidly implementable use cases that bridged the gap between theoretical control and real-world deployment

99 GENERAL AND MISCELLANEOUS

Dark Energy Survey year 6 results: Magnification modeling and its impact on galaxy clustering and galaxy-galaxy lensing cosmology

Gravitational lensing magnification alters the observed spatial distribution of galaxies and must be accounted for to prevent biases in cosmological probes of the large-scale structure. We investigate its effects on the Dark Energy Survey Year 6 galaxy clustering and galaxy-galaxy lensing analyses using the fiducial lens (position tracer) sample M ag L im++. Magnification bias is parameterized by a coefficient that describes the response of the number of selected objects per unlensed area element to a change in the lensing convergence. We quantify this coefficient using the BALROG synthetic source injection catalog to account for the complexity of the selection function, and compare these results with simplified estimates. The resulting values of the magnification coefficients for each redshift bin are [3.16 ± 0.08, 2.76 ± 0.21, 4.09 ± 0.15, 4.42 ± 0.16, 4.90 ± 0.29, 4.83 ± 0.25]. Relative to Year 3, this analysis provides more precise and accurate magnification bias estimates through a larger BALROG area and reweighting to better match the data properties. Here, the cosmological results are robust when tested against various magnification parameter prior choices and also when adding cross-clustering between lens redshift bins. Neglecting magnification, however, introduces significant systematic shifts: relative to the fiducial analysis with Gaussian priors centered on the BALROG -derived estimates, we observe shifts of 1.37σ in S 8 and -0.84σ in Ω m (with cosmic shear included: -0.61σ in S 8 and -0.71σ in Ω m ), in agreement with findings from simulated data, demonstrating that magnification must be modeled to avoid biases. Freeing the magnification bias in lens bin 2 leads to unphysical negative values, further justifying its exclusion from the fiducial Year 6 analysis.

Cosmological parameters

A Sensitivity-driven Wide Area Protection (SWAP) Coordination Tool for High Penetration of Inverter-based Resources (IBR)

Traditionally, power system generation sources have been composed of synchronous generators, of which the fault current behavior is understood with minimal differences between generation size and types due to the physics of their construction. Present protection schemes and modeling methods are based upon these understood characteristics. Most renewable generation is composed of inverter-based resources (IBR), in which fault current is determined by switching control software and hardware limitations, each of which can vary between manufacturers and even between models of the same manufacturer. The resulting fault current is low in magnitude, low in negative-sequence current, unpredictable phase angles, and is a challenge to model. These characteristics also result in a challenge to traditional protection schemes and fault simulation software. To address several of these concerns, the project has the following goals: 1. Improve IBR models: Improve IBR models used in short circuit (SC) programs to accurately capture the response of IBRs at the bulk power system (BPS) level for fault and protection studies. 2. Develop automation tool: Develop an automation tool that allows engineers to identify protection coordination and sensitivity issues by performing SC and protection coordination studies in a high IBR-penetrated grid by applying variations to the IBR models, faults, contingencies, etc. 3. Develop schemes: Develop new protection mitigation solution schemes that complement the existing protection systems to ensure safe operation of the BPS with higher IBR penetration levels. The project team did not achieve this final goal, as the Department of Energy (DOE) stopped the project early due to changes in DOE funding priorities. The termination notice came at the beginning of the final project phase, while the team was identifying and beginning to investigate protection issues. It should be noted that the team discussed a 100% penetration scenario. However, this scenario would require the use of grid-forming IBR models that are not presently available. Since developing these models requires additional effort, the 100% penetration scenario was not pursued during this project. In the future, developing the methodology and models for the 100% scenario could benefit the industry.

14 SOLAR ENERGY

Utilities Perspective on Protection Challenges with High IBR Penetration

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, we are looking broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the presentation summarizes on gathered data and internal experiences.

24 POWER TRANSMISSION AND DISTRIBUTION

Hazard and risk analysis framework for nuclear power plant–based integrated energy systems

Employing integrated energy systems (IESs) with nuclear power plants (NPPs) can improve NPP utilization by leveraging dedicated thermal and electric power delivery, but it may also increase operational safety risks. This paper presents a framework to identify and quantify hazards and risks for such IESs. The framework combines accidentology to review past industrial accidents with failure modes and effects analysis (FMEA) to identify potential future incidents. Hydrogen explosion and toxic chemical release hazards are of particular concern. Explosion consequences are quantified using the Bauwens-Dorofeev (Bauwens) and trinitrotoluene equivalent mass (TNT-EM) methods, while chemical release consequences are computed using the Gaussian atmospheric dispersion method. Operational disturbances from direct electrical and thermal integration that may affect NPP safety are modeled using probabilistic risk analysis (PRA). Hazards and risks are then evaluated for regulatory compliance. The framework is applied to IESs comprising pressurized or boiling water reactors supplying three levels of thermal and electrical power to industrial customers. Case studies include high-temperature steam electrolysis hydrogen plants of varying capacities and a synthetic fuel production plant. Sensitivity analysis examines piping component failures in the PRA model as a precursor to cost estimation for thermal extraction line design. Additionally, Fussel-Vessely (FV) and risk increase importance (RII) measures identify risk-informed design improvements for the thermal extraction system. FMEA highlights hazards such as loss of offsite power, prompt loss of electrical load, loss of thermal output, and immediate steam diversion, in addition to hydrogen explosions and toxic chemical releases. Both Bauwens and TNT-EM methods suggest maintaining several hundred meters of separation between the NPP and hydrogen facility to mitigate explosion risks. PRA results show a maximum initiating event frequency increase of 1.15% and an overall risk increase of 0.28%. Importance measure analysis identifies upstream pipe leak isolation components as critical. Evaluating the results against safety regulations, it is concluded that hazards and risks can be managed to comply with regulations through risk-informed thermal and electrical connection designs, component selection, maintenance programs, and safe separation distances between NPPs and integrated industrial facilities.

08 - HYDROGEN