Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electricity consumption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Fifth-Generation District Heating and Cooling Substations: Demand Response with Artificial Neural Network-Based Model Predictive Control

District heating and cooling (DHC) is considered one of the most sustainable technologies to meet the heating and cooling demands of buildings in urban areas. The fifth-generation district heating and cooling (5GDHC) concept, often referred to as ambient loops, is a novel solution emerging in Europe and has become a widely discussed topic in current energy system research. 5GDHC systems operate at a temperature close to the ground and include electrically driven heat pumps and associated thermal energy storage in a building-sited energy transfer station (ETS) to satisfy user comfort. This work presents new strategies for improving the operation of these energy transfer stations by means of a model predictive control (MPC) method based on recurrent artificial neural networks. The results show that, under simple time-of-use utility rates, the advanced controller outperforms a rule-based controller for smart charging of the domestic hot water (DHW) thermal energy storage under specific boundary conditions. By exploiting the available thermal energy storage capacity, the MPC controller is capable of shifting up to 14% of the electricity consumption of the ETS from on-peak to off-peak hours. Therefore, the advanced control implemented in 5GDHC networks promotes coupling between the thermal and the electric sector, producing flexibility on the electric grid.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Puerto Rico Energy Efficiency Scenario Analysis Tool (PREESAT)

The National Renewable Energy Laboratory (NREL) developed the Puerto Rico Energy Efficiency Scenario Analysis Tool (PREESAT) to allow stakeholders to estimate the long-term aggregate electricity consumption impacts of various energy efficiency measures in Puerto Rico’s residential, commercial, and industrial sectors. PREESAT is an energy accounting framework that addresses electricity use. This report provides an overview of the tool and serves as a user manual with instructions for users.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Puerto Rico Energy Efficiency Scenario Analysis Tool (PREESAT)

The National Renewable Energy Laboratory (NREL) developed the Puerto Rico Energy Efficiency Scenario Analysis Tool (PREESAT) to allow stakeholders to estimate the long-term aggregate electricity consumption impacts of various energy efficiency measures in Puerto Rico’s residential, commercial, and industrial sectors. PREESAT is an energy accounting framework that addresses electricity use. These presentation slides provide a summary of the electrical sector in Puerto Rico and an overview of how the PREESAT tool can be used to project energy savings from various energy efficiency measures in the residential, commercial, and industrial sectors.

commercial↗

Demonstration of Intelligent HVAC Load Management With Deep Reinforcement Learning: Real-World Experience of Machine Learning in Demand Control

We report that buildings account for 40% of total primary energy consumption and 30% of all CO 2 emissions worldwide. A large portion of building energy consumption is due to heating, ventilation, and air-conditioning (HVAC) systems. In the summer, for example, more than 50% of a building’s electricity consumption is used for cooling. With proper energy management, buildings can provide load shifting, peak shaving, frequency regulation, and many other demand response services.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Implementation and validation of optimal start control strategy for air conditioners and heat pumps

Commercial buildings are responsible for approximately 20 % of the total energy consumption and greenhouse gas emissions in the United States. Over 85 % of these buildings lack building automation systems, and many are small (<50,000 square feet), underserved, and use rooftop units (RTUs) for heating, ventilation, and air-conditioning needs. Because these buildings lack proper energy management systems, several operational deficiencies lead to excess energy consumption. Studies have shown that managing the RTUs’ heating and cooling set points, schedules, setbacks, and optimal start can result in a 20 % to 25 % reduction in electricity consumption in small commercial buildings. These buildings typically use fixed schedules to start the RTUs 60 to 120 min before occupancy begins, which results in excess energy consumption. This paper presents research that demonstrates and evaluates the performance of four optimal start methods, which utilize data-based modeling as a key element in facilitating adaptive control in response to time-varying inputs while requiring minimal sensor inputs. The evaluation found energy savings in two commercial buildings equipped with RTUs by periodically alternating four different optimal start models during the cooling and heating season. The resulting energy savings are positive for all models and range from 2 to 5 kWh/day/unit. The units on the east side of the building showed higher savings, while interior units showed greater variability in savings due to the differences in capacities and room sizes. Savings were considerably greater during the heating season compared to the cooling season. The performance of all four models on Mondays was poor; models suggested a shorter optimal start time, which resulted in relatively larger errors. Finally, the future work will look at using a different model for the days after weekends and holidays.

42 ENGINEERING↗

Optimizing district energy systems under uncertainty: Insights from a case study from Washington D.C., USA

This study investigates solutions for delivering affordable heating and cooling to a brownfield site, focusing on a case study in Washington, DC. Moving towards more diverse and resilient energy systems, we identify the optimal portfolio for a district energy system with diverse energy sources to meet the area’s energy demands. Our methodological approach integrates two detailed models: one calculating building-level energy demand and the other optimizing district energy technology choices based on their demand profiles, accounting for uncertainties in energy prices, policies, and other parameters. The results provide an economic comparison of district and individual supply options at the building level, emphasizing the flexibility district systems can offer to the electricity sector. District energy systems demonstrate cost-stabilization benefits amidst volatile energy prices and external uncertainties. For heating, district systems yield significant cost savings compared to individual solutions, driven by fuel flexibility and the use of local renewable energy sources. For cooling, district systems also show advantages, though individual systems may remain more cost-effective for smaller buildings. Additionally, district systems exhibit considerable flexibility on the heating side, as evidenced by variations in electricity consumption. We recommend future research to explore the relationship between the economics of district energy systems, particularly at the building level, and their flexibility potential for the electricity sector across diverse geographic contexts to reduce overall grid costs and promote grid reliability. This includes areas with distinct zoning laws, municipal priorities, utility structures, and funding mechanisms, such as the United States, and regions like Europe with pronounced electricity price volatility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design Requirements and Software Specification for the Autonomous Energy Management Software System for Small Commercial Buildings

Commercial buildings are responsible for approximately 20 percent of the total United States energy consumption and greenhouse gas emissions. Over 85 percent of these buildings lack building automation systems. Many of these buildings are small (<50,000 square feet), underserved, and use rooftop units for heating, ventilation, and air-conditioning needs. Because these buildings lack proper energy management systems, they have several operational deficiencies that lead to excess energy consumption. Studies have shown that managing the rooftop units heating and cooling set points, schedules, setbacks, and optimal start can result in 20 to 25 percent reduction in electricity consumption in small commercial buildings. In addition, improving demand flexibility of these buildings will result additional cost savings for the building owner. Therefore, the Department of Energy’s Building Technologies Office approved a project to address the needs for small commercial buildings. The project is led by Pacific Northwest National Laboratory (PNNL) with Intellimation LLC as the cooperative research and development agreement partner. The primary goal of the project is to develop and validate an autonomous energy management software (AEMS) system that will continuously optimize small commercial building operations by minimizing energy consumption and cost, while providing a solution for maximizing decarbonization benefits from electrification of buildings. The work will leverage the vast experience of PNNL research and development staff who have over two decades of experience in developing and successfully transferring software technologies to the private sector. This solution will be jointly developed with Intellimation, a company that plans to use it to scale their building energy efficiency (EE) and grid services offering. Widespread deployment of the AEMS system will improve the EE and demand flexibility of the building commercial building stock. It should also support cities and states in meeting their climate change mitigation goals. This document describes the various EE and grid service features of the AEMS system, infrastructure and data required to implement those features, and how the features should be automated. It also details how the various features will be tested and validated, including field validation. The document also details what flexibility the users have and how they will be able to leverage those capabilities exercise those. The intent is to create an AEMS system that would support scalable deployment, requires minimal configuration, and is easy to maintain over its expected lifespan. The initial alpha release of AEMS system is planned for March 2023, and the beta release is planned for the summer of 2023. The final release is planned for March 2024. Section 2 of the report documents the relevant building types that AEMS is suitable for. Section 3 documents EE features that will be supported. It will also include the data requirements, hardware requirements, implementation details, and how EE features will be tested and validated. Grid service features will be documented in section 4, including data requirements, hardware requirements, implementation details, and how the services will be tested and validated. Planned next steps are described in section 5.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design Requirements and Hardware Specification for the Low-Cost, Interoperable, User-Centric, Supervisory Controller Kit for Small and Medium Size Commercial Buildings

Commercial buildings are responsible for approximately 20 percent of the total United States energy consumption and greenhouse gas emissions. Over 85 percent of these buildings lack building automation systems to manage the various building systems they have. Many of these buildings are small (< 50,000 square feet), underserved, and use rooftop units (RTUs) for heating, ventilation, and air-conditioning needs. Because these buildings lack proper control systems, they have several operational deficiencies that lead to excess energy consumption. Studies have shown that managing the RTU’s heating and cooling setpoints, schedules, setbacks, and optimal start times can result in 20 to 25 percent reduction in electricity consumption in small and medium commercial buildings (SMBs). In addition, improving the demand flexibility of these buildings will result in additional cost savings for the building owner.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Distributed Wind Guidebook [Slides]

Distributed wind energy technologies generate clean, carbon-free power close to the point of electrical consumption (i.e., close to people and their energy needs). Distributed wind energy can help individuals and communities meet their unique goals, such as reducing impacts on climate change, decreasing electricity bills, boosting energy independence or autonomy from the electric grid, and enhancing grid reliability and resiliency. This guidebook is designed to support individuals and communities in deploying distributed wind energy technologies by providing fundamental information needed for success. Each section is framed around a key question in the journey to deployment and offers resources to help you answer it.

17 WIND ENERGY↗

Field Evaluation of the High Efficiency Dehumidification System (HEDS) at the Timken Museum of Art - Measurement and Verification (M&V) Results from Summer, Winter and Spring Evaluation Periods

The High Efficiency Dehumidification System (HEDS) technology from Conservant Systems Inc., installed at the Timken Museum of Art in San Diego, California, was evaluated to determine its performance relative to appropriate baseline operation. Data was collected for measurement and verification for several weeks during three evaluation periods: Summer (Aug-Sep 2023), Winter (Dec 2023-Feb 2024) and Spring (May-Jun 2024). The evaluation included operating the heating, ventilation and air conditioning (HVAC) system in both constant air volume (CAV) and variable air volume (VAV) modes, with and without the HEDS energy recovery and HVAC system optimization technology enabled. The electricity consumption of the chiller and the gas-supplied reheat energy were measured to characterize savings achieved by the HEDS operation. Based on these measurements, the HEDS was responsible for chiller electrical load savings during the summer evaluation period of 39% and 42% for the CAV and VAV operating modes, respectively; 97% and 100% chiller electrical load reductions were observed during the winter evaluation for the CAV and VAV operating modes, respectively; and the corresponding reductions during the spring evaluation were 42% and 52% for CAV and VAV operation, respectively. The measured reheat energy reductions, which are typically provided by natural gas, due to the HEDS during summer were 64% and 97% in CAV and VAV operating modes, respectively, while the corresponding values were 99% and 78% during the winter evaluation, and 59% and 56% during the spring evaluation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Facility CO2 Flow Tool (FCFT) v0.9

Facility CO2 Flow Tool assists facilities and entities to visualize their CO2 flows for accounting and decarbonization purposes. To do so, the suite offers two components – an MS Excel-based input workbook and a web-based visualization tool. The workbook serves as the input sheet, utilizing the user-provided process and equipment-level energy consumption data to calculate the corresponding CO2 emissions. The web-based tool utilizes the data from this workbook to generate a Sankey diagram. This diagram visually represents the CO2 flow originating from the fuel and electricity consumption within the facility/entity boundary.

Khan, Ovais↗

Self‐Assembled NiO Nanocrystal Arrays as Memristive Elements

Abstract Memristive switching, a nonlinear current–voltage ( I – V ) characteristic, has seen a tremendous surge in interest as an approach to achieve implementation of synaptic functions. The memristive switching behavior of self‐assembled NiO nanocrystals is investigated via scanning probe microscopy, based on first‐order reversal curve current–voltage spectroscopy. Synaptic switching is clearly observed as a direct consequence of filament growth (i.e., gradually increased conductance) in the nanocrystals. A spatial dependency of the conduction in the nanocrystals suggests that there is a localization of the switching filament. The current understanding of this localization ignores features related to local lateral variation current, which can generate an excessive local heat and temperature such as electrical dissipation. The observation of low electrical dissipation at the edge of the nanocrystals shows that less energy is wasted as heat such that the bias applied can be utilized more efficiently to assist the nucleation of the filament and thus reduces the power consumption. Electrical power dissipation is also found to scale with nanocrystal height and has spatial dependence within the nanocrystals. The combination of synaptic switching and high density of the nanocrystals demonstrate that it is feasible to exploit them to create a basic architecture for neuromorphic memory devices.

Kurnia, Fran↗

Reducing Economy-Wide Greenhouse Gas Emissions with Electrofuels and Biofuels as the Grid Decarbonizes

Biofuels and electrofuels have the potential to complement electrification in speeding greenhouse gas emissions reductions, especially in hard-to-decarbonize sectors. Concentrated waste CO 2 streams that can be used as a feedstock for electrofuels, however, may become less available as the share of renewable electricity increases and industries undergo decarbonization. Here, we conduct an analysis with detailed treatment of biofuels and electrofuels to probe their role in decarbonizing multiple industrial sectors and transportation. We examine how the changing availability of CO 2 could affect electrofuel production and the potential role of direct air capture in stabilizing the supply of CO 2 . The results indicate that biofuels could fulfill 12% of the total final energy demand across all U.S. sectors in 2050. Using seven industrial source points of CO 2 available in 2050, 15,388 PJ of electrofuels could be produced, which amounts to 25% of the total final energy demand. This result holds even upon decarbonization that requires direct air capture to boost the CO 2 supply. Biofuels and e-fuels have the potential to reduce economy-wide GHG emissions by 7 and 21% beyond electrification alone. However, electricity consumption and land use grow markedly with decarbonization at scale.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Life‐cycle greenhouse gas emissions associated with nuclear power generation in the United States

Under the 2022 Inflation Reduction Act, tax credits of up to $3/kgH 2 are available to hydrogen producers if they generate emissions at levels below 0.45 kgCO 2 e/kgH 2 , spurring producers to explore how hydrogen production via electrolysis using electricity generated by nuclear power may qualify for such tax credits. With uranium as a primary fuel for nuclear power plants (NPPs) and no on-site emissions, the upstream emissions associated with nuclear fuel supply chains largely determine the carbon intensity of nuclear energy. Using the GREET (Greenhouse gases, Regulated Emissions, and Energy use in Technologies) model, we evaluated the life-cycle greenhouse gas (GHG) emissions of uranium production and the use of uranium to generate electricity in light water reactor (LWR) NPPs. We evaluated the process chemicals and energy inputs throughout the nuclear fuel supply chain to identify the major contributors to nuclear fuel cycle GHG emissions. Such emissions are estimated at 3.0 gCO 2 e/kWh at NPPs in the United States. The greatest share of nuclear fuel cycle GHG emissions—comprising 53% of total emissions—are associated with electricity consumption throughout the fuel supply chain. We extended the analysis to include an evaluation of the carbon intensity of H 2 production via electrolysis using nuclear power from LWRs. Finally, we examined the impact of future (2035 and 2050) electricity supply chain scenarios on nuclear fuel cycle GHG emissions. Our analysis revealed a decrease of 33% (2035) and 46% (2050) in the carbon intensity of nuclear electricity relative to current nuclear fuel cycle GHG emissions.

greenhouse gas emissions↗

Regional Variation in Light-Duty Plug-in Electric Vehicle Emissions

Automobile electrification is viewed as one of the key requirements for deep decarbonization of transportation. However, the exact magnitude of decarbonization from switching from a combustion of petroleum-based fuels to grid-derived electricity is a complex issue. Variations in local grid mixes lead to differing carbon intensities of electricity in different regions. This complexity is compounded by geographical differences in vehicle characteristics. This analysis considers these geographic differences to produce a historical assessment of the fuel-cycle carbon emissions of plug-in electric vehicles (PEVs) in the United States from 2011 to 2021. We find that PEVs in the United States decreased in electricity-derived carbon intensity, from 187 grams per mile to 110 grams per mile from 2011 to 2021 due to improvements in the electric grid and vehicle efficiency. Through 2021, PEVs emitted a total of 13.6 million metric tons of greenhouse gas (GHG) emissions in the United States, including both emissions from electricity and gasoline, while driving a total of 100 billion miles. Of this total, 8.39 million metric tons was due to electricity consumption. Over the same distance, comparable gasoline vehicles would have emitted between 29 and 41 million metric tons of GHG, leading to a reduction of 15 to 27 million metric tons. Relative to national-level assessments that do not factor in this regional difference, these electric vehicles resulted in 13% greater reductions in GHG emissions than previously calculated. In the future, announced goals to further decarbonize the electricity sector will continue to reduce the emissions of PEVs, including reducing emissions rates for vehicles already on the road, further improving the benefits relative to the unchanging emissions of contemporaneous gasoline vehicles.

02 PETROLEUM↗

A case study of replacing pneumatic tools with battery-powered ones at an automobile assembly plant

Compressed air is ubiquitous in manufacturing facilities and vital for the proper operation of numerous types of manufacturing equipment and processes, but compressed air systems are highly inefficient. One way of reducing compressed air usage and the associated electricity consumption is to replace pneumatic tools with battery-powered ones. This paper studied the energy cost savings and return on investment (ROI) of replacing pneumatic torque wrenches with battery-powered ones at a typical automobile assembly plant. With a total triggered time of 400.6 hours and an assumed electricity rate of &dollar;0.10/kWh, the annual energy cost savings was estimated to be &dollar;104/year per tool. The simple payback period and ROI were 5.8 years and 17.3%, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Frost Sensor for HVAC Applications

Frost is a common problem in heating, ventilation, and air conditioning (HVAC) systems that can degrade their efficiencies, leading to excessive electricity consumption. Appropriate defrosting is therefore essential for heat pumps and refrigeration systems. However, these systems typically run the defrost cycle based on a predetermined time interval, a method that does not accurately identify the amount of frost and thus consume excessive electricity. To substantially improve defrosting initiation and termination, this paper describes development of a smart sensor based on a capacitive sensing technique that can quantify frost accumulation and difference between frost, ice, and water. The reported sensor adopts interdigitated comb electrodes and can be updated to a potential multifunctional sensor array for the enhancing identification of frost, ice, and water with the integrated measurement of surface temperature, frost capacitance, and resistance. The proposed frost sensor is potentially expected to have widespread applications in HVAC systems, including heat pumps, refrigerators, and commercial refrigeration systems.

Gao, Zhiming↗

Validating and Comparing Energy Estimation Methods at Water Resource Recovery Facilities

Water resource recovery facilities play a crucial role in the water-energy nexus, consuming a substantial amount of energy in the United States. Growing treatment volumes and more stringent water quality standards are expected to increase the amount of energy needed to treat wastewater, but accurately estimating energy consumption and potential remains challenging due to variability in scale, treatment methods, and effluent treatment standards. In this study, we used publicly available data to evaluate the accuracy of methods for estimating energy consumption and generation, then quantified uncertainty based on key factors like flow rate, treatment level, and geographic location. To validate methods, we estimated energy consumption and generation at the facility-level, then compared estimates to self-reported data from utilities in major U.S. cities. We found that process models of treatment trains under best practice configurations were accurate relative to other methods for estimating electricity use, total energy use, and electricity generation from biogas utilization, and less complex methods based on effluent treatment level and prime movers also performed well for estimating electricity consumption and generation, respectively. Applying the evaluated methods to a national inventory of treatment facilities, we estimate that annual energy consumption ranged from 56.3 x 10^3 to 82.5 x 10^3 TJ in 2012 and 83.6 x 10^3 to 127 x 10^3 TJ in 2042. Our results indicate that not all estimation methods are suited for every use case, so we recommend that researchers and practitioners select an estimation method based on data availability and desired computational intensity.

Hodson, Abigayle↗