Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electricity consumption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Implementation and validation of optimal start control strategy for air conditioners and heat pumps

Commercial buildings are responsible for approximately 20 % of the total energy consumption and greenhouse gas emissions in the United States. Over 85 % of these buildings lack building automation systems, and many are small (<50,000 square feet), underserved, and use rooftop units (RTUs) for heating, ventilation, and air-conditioning needs. Because these buildings lack proper energy management systems, several operational deficiencies lead to excess energy consumption. Studies have shown that managing the RTUs’ heating and cooling set points, schedules, setbacks, and optimal start can result in a 20 % to 25 % reduction in electricity consumption in small commercial buildings. These buildings typically use fixed schedules to start the RTUs 60 to 120 min before occupancy begins, which results in excess energy consumption. This paper presents research that demonstrates and evaluates the performance of four optimal start methods, which utilize data-based modeling as a key element in facilitating adaptive control in response to time-varying inputs while requiring minimal sensor inputs. The evaluation found energy savings in two commercial buildings equipped with RTUs by periodically alternating four different optimal start models during the cooling and heating season. The resulting energy savings are positive for all models and range from 2 to 5 kWh/day/unit. The units on the east side of the building showed higher savings, while interior units showed greater variability in savings due to the differences in capacities and room sizes. Savings were considerably greater during the heating season compared to the cooling season. The performance of all four models on Mondays was poor; models suggested a shorter optimal start time, which resulted in relatively larger errors. Finally, the future work will look at using a different model for the days after weekends and holidays.

42 ENGINEERING↗

Optimizing district energy systems under uncertainty: Insights from a case study from Washington D.C., USA

This study investigates solutions for delivering affordable heating and cooling to a brownfield site, focusing on a case study in Washington, DC. Moving towards more diverse and resilient energy systems, we identify the optimal portfolio for a district energy system with diverse energy sources to meet the area’s energy demands. Our methodological approach integrates two detailed models: one calculating building-level energy demand and the other optimizing district energy technology choices based on their demand profiles, accounting for uncertainties in energy prices, policies, and other parameters. The results provide an economic comparison of district and individual supply options at the building level, emphasizing the flexibility district systems can offer to the electricity sector. District energy systems demonstrate cost-stabilization benefits amidst volatile energy prices and external uncertainties. For heating, district systems yield significant cost savings compared to individual solutions, driven by fuel flexibility and the use of local renewable energy sources. For cooling, district systems also show advantages, though individual systems may remain more cost-effective for smaller buildings. Additionally, district systems exhibit considerable flexibility on the heating side, as evidenced by variations in electricity consumption. We recommend future research to explore the relationship between the economics of district energy systems, particularly at the building level, and their flexibility potential for the electricity sector across diverse geographic contexts to reduce overall grid costs and promote grid reliability. This includes areas with distinct zoning laws, municipal priorities, utility structures, and funding mechanisms, such as the United States, and regions like Europe with pronounced electricity price volatility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design Requirements and Software Specification for the Autonomous Energy Management Software System for Small Commercial Buildings

Commercial buildings are responsible for approximately 20 percent of the total United States energy consumption and greenhouse gas emissions. Over 85 percent of these buildings lack building automation systems. Many of these buildings are small (<50,000 square feet), underserved, and use rooftop units for heating, ventilation, and air-conditioning needs. Because these buildings lack proper energy management systems, they have several operational deficiencies that lead to excess energy consumption. Studies have shown that managing the rooftop units heating and cooling set points, schedules, setbacks, and optimal start can result in 20 to 25 percent reduction in electricity consumption in small commercial buildings. In addition, improving demand flexibility of these buildings will result additional cost savings for the building owner. Therefore, the Department of Energy’s Building Technologies Office approved a project to address the needs for small commercial buildings. The project is led by Pacific Northwest National Laboratory (PNNL) with Intellimation LLC as the cooperative research and development agreement partner. The primary goal of the project is to develop and validate an autonomous energy management software (AEMS) system that will continuously optimize small commercial building operations by minimizing energy consumption and cost, while providing a solution for maximizing decarbonization benefits from electrification of buildings. The work will leverage the vast experience of PNNL research and development staff who have over two decades of experience in developing and successfully transferring software technologies to the private sector. This solution will be jointly developed with Intellimation, a company that plans to use it to scale their building energy efficiency (EE) and grid services offering. Widespread deployment of the AEMS system will improve the EE and demand flexibility of the building commercial building stock. It should also support cities and states in meeting their climate change mitigation goals. This document describes the various EE and grid service features of the AEMS system, infrastructure and data required to implement those features, and how the features should be automated. It also details how the various features will be tested and validated, including field validation. The document also details what flexibility the users have and how they will be able to leverage those capabilities exercise those. The intent is to create an AEMS system that would support scalable deployment, requires minimal configuration, and is easy to maintain over its expected lifespan. The initial alpha release of AEMS system is planned for March 2023, and the beta release is planned for the summer of 2023. The final release is planned for March 2024. Section 2 of the report documents the relevant building types that AEMS is suitable for. Section 3 documents EE features that will be supported. It will also include the data requirements, hardware requirements, implementation details, and how EE features will be tested and validated. Grid service features will be documented in section 4, including data requirements, hardware requirements, implementation details, and how the services will be tested and validated. Planned next steps are described in section 5.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design Requirements and Hardware Specification for the Low-Cost, Interoperable, User-Centric, Supervisory Controller Kit for Small and Medium Size Commercial Buildings

Commercial buildings are responsible for approximately 20 percent of the total United States energy consumption and greenhouse gas emissions. Over 85 percent of these buildings lack building automation systems to manage the various building systems they have. Many of these buildings are small (< 50,000 square feet), underserved, and use rooftop units (RTUs) for heating, ventilation, and air-conditioning needs. Because these buildings lack proper control systems, they have several operational deficiencies that lead to excess energy consumption. Studies have shown that managing the RTU’s heating and cooling setpoints, schedules, setbacks, and optimal start times can result in 20 to 25 percent reduction in electricity consumption in small and medium commercial buildings (SMBs). In addition, improving the demand flexibility of these buildings will result in additional cost savings for the building owner.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Distributed Wind Guidebook [Slides]

Distributed wind energy technologies generate clean, carbon-free power close to the point of electrical consumption (i.e., close to people and their energy needs). Distributed wind energy can help individuals and communities meet their unique goals, such as reducing impacts on climate change, decreasing electricity bills, boosting energy independence or autonomy from the electric grid, and enhancing grid reliability and resiliency. This guidebook is designed to support individuals and communities in deploying distributed wind energy technologies by providing fundamental information needed for success. Each section is framed around a key question in the journey to deployment and offers resources to help you answer it.

17 WIND ENERGY↗

Field Evaluation of the High Efficiency Dehumidification System (HEDS) at the Timken Museum of Art - Measurement and Verification (M&V) Results from Summer, Winter and Spring Evaluation Periods

The High Efficiency Dehumidification System (HEDS) technology from Conservant Systems Inc., installed at the Timken Museum of Art in San Diego, California, was evaluated to determine its performance relative to appropriate baseline operation. Data was collected for measurement and verification for several weeks during three evaluation periods: Summer (Aug-Sep 2023), Winter (Dec 2023-Feb 2024) and Spring (May-Jun 2024). The evaluation included operating the heating, ventilation and air conditioning (HVAC) system in both constant air volume (CAV) and variable air volume (VAV) modes, with and without the HEDS energy recovery and HVAC system optimization technology enabled. The electricity consumption of the chiller and the gas-supplied reheat energy were measured to characterize savings achieved by the HEDS operation. Based on these measurements, the HEDS was responsible for chiller electrical load savings during the summer evaluation period of 39% and 42% for the CAV and VAV operating modes, respectively; 97% and 100% chiller electrical load reductions were observed during the winter evaluation for the CAV and VAV operating modes, respectively; and the corresponding reductions during the spring evaluation were 42% and 52% for CAV and VAV operation, respectively. The measured reheat energy reductions, which are typically provided by natural gas, due to the HEDS during summer were 64% and 97% in CAV and VAV operating modes, respectively, while the corresponding values were 99% and 78% during the winter evaluation, and 59% and 56% during the spring evaluation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Facility CO2 Flow Tool (FCFT) v0.9

Facility CO2 Flow Tool assists facilities and entities to visualize their CO2 flows for accounting and decarbonization purposes. To do so, the suite offers two components – an MS Excel-based input workbook and a web-based visualization tool. The workbook serves as the input sheet, utilizing the user-provided process and equipment-level energy consumption data to calculate the corresponding CO2 emissions. The web-based tool utilizes the data from this workbook to generate a Sankey diagram. This diagram visually represents the CO2 flow originating from the fuel and electricity consumption within the facility/entity boundary.

Khan, Ovais↗

Self‐Assembled NiO Nanocrystal Arrays as Memristive Elements

Abstract Memristive switching, a nonlinear current–voltage ( I – V ) characteristic, has seen a tremendous surge in interest as an approach to achieve implementation of synaptic functions. The memristive switching behavior of self‐assembled NiO nanocrystals is investigated via scanning probe microscopy, based on first‐order reversal curve current–voltage spectroscopy. Synaptic switching is clearly observed as a direct consequence of filament growth (i.e., gradually increased conductance) in the nanocrystals. A spatial dependency of the conduction in the nanocrystals suggests that there is a localization of the switching filament. The current understanding of this localization ignores features related to local lateral variation current, which can generate an excessive local heat and temperature such as electrical dissipation. The observation of low electrical dissipation at the edge of the nanocrystals shows that less energy is wasted as heat such that the bias applied can be utilized more efficiently to assist the nucleation of the filament and thus reduces the power consumption. Electrical power dissipation is also found to scale with nanocrystal height and has spatial dependence within the nanocrystals. The combination of synaptic switching and high density of the nanocrystals demonstrate that it is feasible to exploit them to create a basic architecture for neuromorphic memory devices.

Kurnia, Fran↗

Reducing Economy-Wide Greenhouse Gas Emissions with Electrofuels and Biofuels as the Grid Decarbonizes

Biofuels and electrofuels have the potential to complement electrification in speeding greenhouse gas emissions reductions, especially in hard-to-decarbonize sectors. Concentrated waste CO 2 streams that can be used as a feedstock for electrofuels, however, may become less available as the share of renewable electricity increases and industries undergo decarbonization. Here, we conduct an analysis with detailed treatment of biofuels and electrofuels to probe their role in decarbonizing multiple industrial sectors and transportation. We examine how the changing availability of CO 2 could affect electrofuel production and the potential role of direct air capture in stabilizing the supply of CO 2 . The results indicate that biofuels could fulfill 12% of the total final energy demand across all U.S. sectors in 2050. Using seven industrial source points of CO 2 available in 2050, 15,388 PJ of electrofuels could be produced, which amounts to 25% of the total final energy demand. This result holds even upon decarbonization that requires direct air capture to boost the CO 2 supply. Biofuels and e-fuels have the potential to reduce economy-wide GHG emissions by 7 and 21% beyond electrification alone. However, electricity consumption and land use grow markedly with decarbonization at scale.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Life‐cycle greenhouse gas emissions associated with nuclear power generation in the United States

Under the 2022 Inflation Reduction Act, tax credits of up to $3/kgH 2 are available to hydrogen producers if they generate emissions at levels below 0.45 kgCO 2 e/kgH 2 , spurring producers to explore how hydrogen production via electrolysis using electricity generated by nuclear power may qualify for such tax credits. With uranium as a primary fuel for nuclear power plants (NPPs) and no on-site emissions, the upstream emissions associated with nuclear fuel supply chains largely determine the carbon intensity of nuclear energy. Using the GREET (Greenhouse gases, Regulated Emissions, and Energy use in Technologies) model, we evaluated the life-cycle greenhouse gas (GHG) emissions of uranium production and the use of uranium to generate electricity in light water reactor (LWR) NPPs. We evaluated the process chemicals and energy inputs throughout the nuclear fuel supply chain to identify the major contributors to nuclear fuel cycle GHG emissions. Such emissions are estimated at 3.0 gCO 2 e/kWh at NPPs in the United States. The greatest share of nuclear fuel cycle GHG emissions—comprising 53% of total emissions—are associated with electricity consumption throughout the fuel supply chain. We extended the analysis to include an evaluation of the carbon intensity of H 2 production via electrolysis using nuclear power from LWRs. Finally, we examined the impact of future (2035 and 2050) electricity supply chain scenarios on nuclear fuel cycle GHG emissions. Our analysis revealed a decrease of 33% (2035) and 46% (2050) in the carbon intensity of nuclear electricity relative to current nuclear fuel cycle GHG emissions.

greenhouse gas emissions↗

Regional Variation in Light-Duty Plug-in Electric Vehicle Emissions

Automobile electrification is viewed as one of the key requirements for deep decarbonization of transportation. However, the exact magnitude of decarbonization from switching from a combustion of petroleum-based fuels to grid-derived electricity is a complex issue. Variations in local grid mixes lead to differing carbon intensities of electricity in different regions. This complexity is compounded by geographical differences in vehicle characteristics. This analysis considers these geographic differences to produce a historical assessment of the fuel-cycle carbon emissions of plug-in electric vehicles (PEVs) in the United States from 2011 to 2021. We find that PEVs in the United States decreased in electricity-derived carbon intensity, from 187 grams per mile to 110 grams per mile from 2011 to 2021 due to improvements in the electric grid and vehicle efficiency. Through 2021, PEVs emitted a total of 13.6 million metric tons of greenhouse gas (GHG) emissions in the United States, including both emissions from electricity and gasoline, while driving a total of 100 billion miles. Of this total, 8.39 million metric tons was due to electricity consumption. Over the same distance, comparable gasoline vehicles would have emitted between 29 and 41 million metric tons of GHG, leading to a reduction of 15 to 27 million metric tons. Relative to national-level assessments that do not factor in this regional difference, these electric vehicles resulted in 13% greater reductions in GHG emissions than previously calculated. In the future, announced goals to further decarbonize the electricity sector will continue to reduce the emissions of PEVs, including reducing emissions rates for vehicles already on the road, further improving the benefits relative to the unchanging emissions of contemporaneous gasoline vehicles.

02 PETROLEUM↗

A case study of replacing pneumatic tools with battery-powered ones at an automobile assembly plant

Compressed air is ubiquitous in manufacturing facilities and vital for the proper operation of numerous types of manufacturing equipment and processes, but compressed air systems are highly inefficient. One way of reducing compressed air usage and the associated electricity consumption is to replace pneumatic tools with battery-powered ones. This paper studied the energy cost savings and return on investment (ROI) of replacing pneumatic torque wrenches with battery-powered ones at a typical automobile assembly plant. With a total triggered time of 400.6 hours and an assumed electricity rate of &dollar;0.10/kWh, the annual energy cost savings was estimated to be &dollar;104/year per tool. The simple payback period and ROI were 5.8 years and 17.3%, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Frost Sensor for HVAC Applications

Frost is a common problem in heating, ventilation, and air conditioning (HVAC) systems that can degrade their efficiencies, leading to excessive electricity consumption. Appropriate defrosting is therefore essential for heat pumps and refrigeration systems. However, these systems typically run the defrost cycle based on a predetermined time interval, a method that does not accurately identify the amount of frost and thus consume excessive electricity. To substantially improve defrosting initiation and termination, this paper describes development of a smart sensor based on a capacitive sensing technique that can quantify frost accumulation and difference between frost, ice, and water. The reported sensor adopts interdigitated comb electrodes and can be updated to a potential multifunctional sensor array for the enhancing identification of frost, ice, and water with the integrated measurement of surface temperature, frost capacitance, and resistance. The proposed frost sensor is potentially expected to have widespread applications in HVAC systems, including heat pumps, refrigerators, and commercial refrigeration systems.

Gao, Zhiming↗

Validating and Comparing Energy Estimation Methods at Water Resource Recovery Facilities

Water resource recovery facilities play a crucial role in the water-energy nexus, consuming a substantial amount of energy in the United States. Growing treatment volumes and more stringent water quality standards are expected to increase the amount of energy needed to treat wastewater, but accurately estimating energy consumption and potential remains challenging due to variability in scale, treatment methods, and effluent treatment standards. In this study, we used publicly available data to evaluate the accuracy of methods for estimating energy consumption and generation, then quantified uncertainty based on key factors like flow rate, treatment level, and geographic location. To validate methods, we estimated energy consumption and generation at the facility-level, then compared estimates to self-reported data from utilities in major U.S. cities. We found that process models of treatment trains under best practice configurations were accurate relative to other methods for estimating electricity use, total energy use, and electricity generation from biogas utilization, and less complex methods based on effluent treatment level and prime movers also performed well for estimating electricity consumption and generation, respectively. Applying the evaluated methods to a national inventory of treatment facilities, we estimate that annual energy consumption ranged from 56.3 x 10^3 to 82.5 x 10^3 TJ in 2012 and 83.6 x 10^3 to 127 x 10^3 TJ in 2042. Our results indicate that not all estimation methods are suited for every use case, so we recommend that researchers and practitioners select an estimation method based on data availability and desired computational intensity.

Hodson, Abigayle↗

Retrofitting Holcim Ste. Genevieve Cement Plant with CO2 Capture Plant Using Air Liquide Cryocap™ FG Technology

The global cement manufacturing industry is a major contributor to carbon dioxide emissions. The International Energy Agency's "Net Zero Emissions by 2050 Scenario" identifies CCS as a major strategy for meeting that goal. This project is among the first attempts to transfer capture technology developed at coal-fired power plants to the cement industry. The main objective of the project is to execute and complete a front-end engineering and design (FEED) studies for commercial-scale, carbon capture projects that separates 95% of the total CO2 emissions at the Holcim (US) Ste. Genevieve cement manufacturing facility using Air Liquide’s Pressure Swing Adsorption system (PSA) assisted Cryocap™ technology. The Holcim Ste. Genevieve cement plant in Missouri, US, boasts one of the largest single cement production lines in the world, with a capacity of approximately 12,000 t/day. The plant currently uses traditional fuels, namely coal and petcoke. The captured CO2 will be pipeline and geological storage grade. The industrial host site emits approximately 3.0 million tonne CO2/yr. Air Liquide’s Cryocap™ technology has been developed over the last 18+ years for CO2 capture applications. It has been shown to be applicable to a variety of industrial applications (e.g., steel, cement, SMR, Fluidized Catalytic Crackers (FCCs)). Cryocap™ FG consists of a Pressure Swing Adsorption (PSA) unit coupled with a Cryogenic System. The PSA pre-concentrates the CO2 from the flue gas, while the cryogenic unit enables the CO2 purity to be increased to the desired level. The project team is led by the Prairie Research Institute at the University of Illinois at Urbana-Champaign. The tasks include: complete FEED study for retrofitting the industrial facility with a carbon capture system to support developing a detailed cost estimate; business case analysis outlining the anticipated revenue and credits if projects was built and operated; technoeconomic analysis (TEA) outlining how capture system achieves DOE capture goals; and life cycle (LCA) analysis demonstrating zero net carbon emissions. The FEED study was successfully completed. This includes completing the process basis of design; preliminary engineering; outside battery limits (OSBL) detailed engineering including a Zero Liquid Discharge (ZLD) wastewater treatment system; inside battery limits (ISBL) detailed engineering [1]. An overall project capital cost estimate within a -20%/+30% accuracy was developed. The major contributors to the Total Plant Cost (TPC), by system, are the costs associated with the Outside Battery Limit (OSBL) section of the plant which includes a new river water intake structure and a Zero Liquid Discharge (ZLD) system. By cost category, the major contributors to the TPC are equipment and subcontractor costs, followed closely by engineering, construction management, home office and contractor fees. The TEA has been created to reflect the findings of the project. It analyzes the economic performance of the Cryocap™ technology by reviewing the estimated capital costs, operating cost, and revenue. The Cost of Capture (COC) associated with the Cryocap™ technology for 95% CO2 capture, when considering NETL 2018 economic assumptions (42/58 debt/equity ratio, 5.15% interest on debt and 1.42% return on equity in real dollars) and 2022 economic assumptions (42/58 debt/equity ratio, 8.82% interest on debt and 4.90% return on equity in real dollars) was found to be much lower than that for the DOE-NETL’s base-line cases. The highest contributors to the COC are annualized capital expenditures (CAPEX) and electricity consumption which can be offset by using lower cost renewable sources. The LCA was conducted using OpenLCA which is an open-source software that is recommended by NETL. The database utilized for this study was a modified version of TRACI 2.1 (developed by the US. Environmental Protection Agency’s National Risk Management Research Laboratory and modified by NETL). The Cryocap™ FG technology does not consume fuels in significant quantities and does not utilize specialized chemical solvents subject to decomposition, such as those utilized in amine-based carbon capture systems. The Cryocap™ FG technology mainly utilizes electricity as its energy input; hence, its calculated emissions are mainly associated with the generation of electricity offsite and are dependent on the energy matrix of the grid at the time of project implementation. The water consumption impact of the Cryocap™ FG is mostly for makeup of the water lost by evaporation in the cooling tower; however, the carbon capture plant will be equipped with a ZLD system to avoid effluent streams and minimize water consumption. The successful construction and operation of this plant based on this study results will provide a means to demonstrate an economically attractive and transformational capture technology that can be used to retrofit existing plants and be deployed at new plants.

01 COAL, LIGNITE, AND PEAT↗

Staying cool: The development of India's pioneering energy efficiency policy for chillers

Abstract Chillers are the key energy‐consuming piece of equipment in most large space cooling systems. They can account for more than 40% of total energy consumption in any typical commercial building and in specific industrial building installations depending on the product and process. With climate change driving rapidly rising demand for commercial and industrial cooling, especially in emerging economies, energy efficiency policies for chillers are crucial to moderate future electricity demand and thereby minimize greenhouse gas emissions. However, most developing and emerging economies lack energy efficiency policies for this significant and growing cooling equipment sector. India recently announced new energy efficiency policies for chillers, projected to avoid 28 TWh of electricity consumption and 23 million tons of CO 2 emissions cumulatively through 2030. This article presents a case study of the unique challenges and solutions required to design a new energy efficiency policy for chillers in India. First, the energy consumed in chiller systems is sensitive to building occupancy, load changes, seasonal variations, operation and maintenance, and climatic conditions. In order to address these sensitivities, the chiller testing standard in India factors local weather and temperature conditions into energy performance ratings to account for these sensitivities. Further, every large chiller is a customized product, therefore developing a viable policy and implementation process required collaboration with international and national experts in standardization, manufacturers, building consultants, and testing laboratories. This article is categorized under: Energy Efficiency > Economics and Policy Solar Energy: Thermal ‐‐> Climate and Environment

Mukherjee, P. K.↗

Major Drivers of Long-Term Distribution Transformer Demand

Distribution transformers, used to step-down medium voltage to service-voltage level for end-use electrical consumption, are currently experiencing major shortages. Utilities are experiencing extended lead times for transformers of up to 2 years (a 4x increase on lead times pre-2022) and prices have gone up by as much as 5-6 times in the past 2 years. Current shortages have been attributed to pent-up post-pandemic demand, workforce shortages and low retention rates, component supply chain challenges, and materials shortages (grain-oriented electrical steel, aluminum, and copper). The supply of this equipment is critical for the reliability and growth of the power system, and in meeting administration climate goals in terms of electrification of demand and the growth of renewable energy. This report details some of the initial analysis conducted by the National Renewable Energy Laboratory (NREL), supported by the Department of Energy's Office of Electricity and Office of Policy, in assessing the long-term demand trends for distribution transformers. Expected increased demand is due to a confluence of not only electrification and renewable energy growth, but also in the context of aging electric infrastructure, increased frequency and severity of extreme weather events, and utility-driven investments in reliability and resiliency of the electricity distribution system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗