Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electromagnetic Transients Simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

95 records · Page 6

Impact of moment-based, energy integrated neutrino transport on microphysics and ejecta in binary neutron star mergers

We present an extensive study of the effects of neutrino transport in three-dimensional general relativistic radiation hydrodynamics (GRHD) simulations of binary neutron star (BNS) mergers using our moment-based, energy-integrated neutrino radiation transport (M1) scheme. Here, we consider a total of eight BNS configurations, while varying equation of state models, mass ratios, and grid resolutions, for a total of 16 simulations. We find that M1 neutrino transport is crucial in modeling the local absorption of neutrinos and the deposition of lepton number throughout the medium. We provide an in-depth look at the effects of neutrinos on the fluid dynamics and luminosity during the late inspiral and postmerger phases, the properties of ejecta and outflow, and the postmerger nucleosynthesis. The simulations presented in this work comprise an extensive study of the combined effect of the equation of state and M1 neutrino transport in GRHD simulations of BNS mergers, and establish that the solution provided by our M1 scheme is robust across system properties.

150 ≤ A ≤ 18959 ≤ A ≤ 8990 ≤ A ≤ 149↗

Transient fuel performance analysis for the preliminary fuel concept of general atomics fast modular reactor

This study investigates the transient fuel performance of General Atomics Fast Modular Reactor (GA-FMR) during accident scenarios, focusing on the behavior of its innovative fuel system that combines high-assay low enriched uranium dioxide (HALEUO2) fuel with SiGA® ceramic matrix composite silicon carbide cladding. The preliminary fuel design’s response was analyzed during reactivity-initiated accidents (RIA) and loss of coolant accidents (LOCA) using BISON fuel performance analysis code, which included both the diffusion enhanced and BISON-FASTGRASS coupled UO 2 models. The RIA analysis demonstrated that effective reactivity control reduced fuel temperature, though with transient fission gas release resulting in additional tensile stress state on the cladding. LOCA simulations revealed differing predictions between the two models: the BISON UO 2 model showed more transient fission gas release but minimal pellet expansion, while the BISON-FASTGRASS UO 2 model predicted less pronounced fission gas release but more fuel swelling and thermal expansion, potentially leading to pellet-cladding mechanical interaction. Here, these findings highlight critical areas for fuel design optimization and identify knowledge gaps requiring further experimental and computational investigation to advance GA-FMR fuel development.

Lee, Soon K. [Argonne National Laboratory (ANL), A↗

Modeling Framework for Data Center

This chapter highlights the critical need for advanced modeling of data centers due to their rapidly increasing energy consumption and impact on grid reliability. Driven by the demand for AI applications, data centers are projected to consume a significant portion of US energy by 2028, putting stress on an already challenged power grid. The chapter emphasizes the importance of "fast" time-scale models to understand the dynamic interactions between data centers and the grid, especially given the rapid power fluctuations of AI workloads. It outlines a modeling framework that includes both offline and real-time EMT domain simulations, detailing the necessary representations for various components like utility interfaces, transformers, IT loads, UPS, cooling loads, Battery Energy Storage Systems (BESS), generators, protection systems, and higher-level control systems. While standard simulation tools like PSCAD offer basic models, custom development is often required to accurately capture the unique and fast-changing behaviors of modern data centers. The chapter also discusses key metrics and test cases for validating these models, focusing on transient load responses, protection relay coordination, and demand flexibility. Finally, it addresses the challenges of modeling large-scale data centers, such as computational complexity and the trade-off between model fidelity and practicality, suggesting hybrid modeling approaches as a solution. The overarching goal is to create a robust framework that helps assess data center impacts on grid stability, identify vulnerabilities, and inform the development of standards for reliable integration of these large loads into the bulk power system.

25 ENERGY STORAGE↗

EMT Model Validation of a 2 MVA PV Inverter Using Transient and Frequency-Domain Hardware Testing: Preprint

This paper presents results and new insights gained from a hardware test campaign on a 2 MVA PV inverter for validating its vendor-supplied EMT model. The test campaign was conducted using a 7 MVA grid simulator and a 2 MW PV emulator. It considered both time-domain transient tests and frequency-domain impedance scan tests. The paper highlights the inadequacy of transient tests in capturing all critical resonance modes of the inverter, and the effectiveness of the frequency scan testing in addressing this problem. The paper shows the frequency scan testing as an effective tool for EMT model validation of IBR units which can highlight inaccuracies in the EMT models that are easy to overlook when model validation is performed using only the time-domain transient tests such as voltage ride-through and phase jump tests.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Identifying Potential Sub-Synchronous Oscillations Using Impedance Scan Approach: Preprint

This paper presents an impedance scan study on the real-world power system in Australia that has observed 17 to 20 Hz intermittent subsynchronous oscillations. Through the impedance scan of each of the IBRs, both individually and collectively, potential resonance modes are identified. The impedance scans were carried out using electromagnetic transient PSCAD models of the network. The network comprises of site-specific, black-boxed models of IBRs supplied by the generators. The impedance scan approach was divided in three major steps: (1) the first step is to identify IBRs where impedance analysis needs to be performed based on the magnitude of oscillations observed at their points of interconnection (POIs); (2) the second step focuses on performing impedance scans at selected IBRs in single-machine infinite-bus (SMIB) configuration to identify internal resonance modes of an IBR and to evaluate if any of these modes become unstable under certain grid conditions; (3) the third step performs impedance scans at a few selected IBRs while connected to the wider network model to obtain the impedance response of both the IBR and the grid - this step evaluates control interactions among IBRs. The impedance scan study found that a few IBRs have an underdamped resonance mode at around 17 Hz, which becomes unstable under a certain operating condition. Another interesting finding was that certain IBRs increase the effective grid impedance seen by another IBR in proximity for a particular operating condition. Under this operating condition, the resulting subsynchronous oscillation mode is more pronounced due to a combination of control interactions among IBRs through the transmission network under study and a resonance mode inside the IBRs.

control interactions↗