Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electron microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Identification of the glassy state in nanoparticles by transmission electron microscopy

Identification of amorphous phases in nanoparticles by atomic-resolution transmission electron microscopy (TEM) requires analyses such as tilt-angle-dependent TEM imaging and single-nanoparticle electron diffraction, rather than relying on a single TEM image. Here, the disordered structures of amorphous nanoparticles offer unique atomic configurations and properties that differ from the properties of their crystalline counterparts. These characteristics have motivated the exploration of such materials for mechanical, sensing and catalytic applications. In addition, the formation of amorphous metal nanoparticles is an important endeavour to understand the process of vitrification and the nature of the glassy state. Atomic-resolution transmission electron microscopy (TEM) is increasingly being used as a tool for characterizing structures of nanoparticles produced by vitrification. In this Comment, we discuss the pitfalls of using TEM for ascertaining whether nanoparticles are amorphous. We also make recommendations of best practices.

Alcorn, Francis M. [Sandia National Laboratories (↗

Electron microscopy data on irradiation effects in glassy carbon, nuclear graphite, pyrolytic carbon, and carbon fibers

Glassy carbon, a monoatomic allotrope of carbon, is a candidate material for components in fission nuclear power systems due to its radiation tolerance. This article presents comprehensive electron microscopy data revealing the effects of neutron and electron irradiation on glassy carbon. For comparison, additional data are provided for pyrolytic graphite and carbon fibers, materials that exhibit similar structural behavior under irradiation. In situ electron irradiation experiments further illustrate the real-time microstructural evolution of glassy carbon during exposure. The dataset is organized into five parts: (1) transmission electron microscopy (TEM) micrographs of as-received and neutron-irradiated glassy carbon; (2) TEM micrographs of neutron-irradiated graphite; (3) TEM micrographs of unirradiated and irradiated carbon–carbon composites; (4) TEM micrographs of pyrolytic carbon specimens in both conditions; (5) scanning transmission electron microscopy (STEM) micrographs of as-received and neutron-irradiated glassy carbon and (6) in situ electron irradiation data of a glassy carbon particle. These datasets provide valuable insights into radiation-induced structural changes in carbon-based materials relevant to nuclear applications.

36 MATERIALS SCIENCE↗

Advancing conventional High-Resolution Electron Microscopy

Due to the exceptional performance of most modern commercial transmission electron microscopes, the achievement of phase-contrast imaging resolution in the sub-2Å range is today a routine exercise, provided the samples are compliant. Nonetheless, there remains room for improvement, and the purpose of this manuscript is to highlight procedures that might be employed by the practicing microscopist for advancing conventional high resolution electron microscopy.

440800* -- Miscellaneous Instrumentation-- (1990-)↗

Single-photoelectron collection efficiency in 4D ultrafast electron microscopy

In femtosecond (fs) 4D ultrafast electron microscopy (UEM), a tradeoff is made between photoelectrons per packet and time resolution. One consequence of this can be longer-than-desirable acquisition times for low-density packets, and particularly for low repetition rates when complete photothermal dissipation is required. Thus, gaining an understanding of photoelectron trajectories in the gun region is important for identifying factors that limit collection efficiency (CE; fraction of photoelectrons that enter the illumination system). Here, we continue our work on the systematic study of photoelectron trajectories in the gun region of a Thermo Fisher/FEI Tecnai Femto UEM, focusing specifically on CE in the single-electron regime. Using General Particle Tracer, calculated field maps, and the exact architecture of the Tecnai Femto UEM, we simulated the effects of fs laser parameters and key gun elements on CE. The results indicate CE strongly depends upon the laser spot size on the source, the (unbiased) Wehnelt aperture diameter, and the incident photon energy. The CE dispersion with laser spot size is found to be strongly dependent on aperture diameter, being nearly dispersionless for the largest apertures. A gun crossover is also observed, with the beam-waist position being dependent on the aperture diameter, further illustrating that the Wehnelt aperture acts as a simple, fixed electrostatic lens in UEM mode. This work provides further insights into the operational aspects of fs 4D UEM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transmission Electron Microscopy of Carbonaceous Matter in Bennu Aggregate Samples

Preliminary analyses of regolith samples from asteroid Bennu show high bulk carbon abundances (~4.7 wt.%). The organic matter is readily apparent in scanning electron microscopy (SEM), transmission electron microscopy (TEM), and NanoSIMS observations. A major objective of the OSIRIS-REx mission is to understand the nature and origin of the pre-biotic organic matter inventory in Bennu samples. Here we report on TEM studies of indigenous organic matter in Bennu aggregate samples.

L P Keller↗

Chemical Environment and Structural Variations in High Entropy Oxide Thin Film Probed with Electron Microscopy

For this work, we employ analytical transmission electron microscopy (TEM) to correlate the structural and chemical environment variations within a stacked epitaxial thin film of the high entropy oxide (HEO) Mg 0.2 Co 0.2 Ni 0.2 Cu 0.2 Zn 0.2 O (J14), with two layers grown at different substrate temperatures (500 and 200 °C) using pulsed laser deposition (PLD). Electron diffraction and atomically resolved STEM imaging reveal the difference in out-of-plane lattice parameters in the stacked thin film, which is further quantified on a larger scale using four-dimensional STEM (4D-STEM). In the layer deposited at a lower temperature, electron energy loss spectroscopy (EELS) mapping indicates drastic changes in the oxidation states and bonding environment for Co ions, and energy-dispersive X-ray spectroscopy (EDX) mapping detects more significant cation deficiency. Ab initio density functional theory (DFT) calculations validate that vacancies on the cation sublattice of J14 result in significant electronic and structural changes. The experimental and computational analyses indicate that low temperatures during film growth result in cation deficiency, an altered chemical environment, and reduced lattice parameters while maintaining a single phase. Our results demonstrate that the complex correlation of configurational entropy, kinetics, and thermodynamics can be utilized for accessing a range of metastable configurations in HEO materials without altering cation proportions, enabling further engineering of functional properties of HEO materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electron Microscopy of Natural and Epitaxial Diamond

Semiconducting diamond films have the potential for use as a material in which to build active electronic devices capable of operating at high temperatures or in high radiation environments. Ultimately, it is preferable to use low-defect-density single crystal diamond for device fabrication. We have previously investigated polycrystalline diamond films with transmission electron microscopy (TEM) and scanning electron microscopy (SEM), and homoepitaxial films with SEM-based techniques. This contribution describes some of our most recent observations of the microstructure of natural diamond single crystals and homoepitaxial diamond thin films using TEM.

Posthill, J. B.↗

Influence of Photoemission Geometry on Timing and Efficiency in 4D Ultrafast Electron Microscopy

Broader adoption of 4D ultrafast electron microscopy (UEM) for the study of chemical, materials, and quantum systems is being driven by development of new instruments as well as continuous improvement and characterization of existing technologies. Perhaps owing to the still-high barrier to entry, the full range of capabilities of laser-driven 4D UEM instruments has yet to be established, particularly when operated at extremely low beam currents (~fA). Accordingly, with an eye on beam stability, we have conducted particle tracing simulations of unconventional off-axis photoemission geometries in a UEM equipped with a thermionic-emission gun. Specifically, we have explored the impact of experimentally adjustable parameters on the time-of-flight (TOF), the collection efficiency (CE), and the temporal width of ultrashort photoelectron packets. The adjustable parameters include the Wehnelt aperture diameter (DW), the cathode set-back position (Ztip), and the position of the femtosecond laser on the Wehnelt aperture surface relative to the optic axis (Rphoto). Notable findings include significant sensitivity of TOF to DW and Ztip, as well as non-intuitive responses of CE and temporal width to varying Rphoto. As a means to improve accessibility, practical implications and recommendations are emphasized wherever possible.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microstructure-Sensitive Investigation of Fracture Using Acoustic Emission Coupled With Electron Microscopy

A novel technique using Scanning Electron Microscopy (SEM) in conjunction with Acoustic Emission (AE) monitoring is proposed to investigate microstructure-sensitive fatigue and fracture of metals. The coupling between quasi in situ microscopy with actual in situ nondestructive evaluation falls into the ICME framework and the idea of quantitative data-driven characterization of material behavior. To validate the use of AE monitoring inside the SEM chamber, Aluminum 2024-B sharp notch specimen were tested both inside and outside the microscope using a small scale mechanical testing device. Subsequently, the same type of specimen was tested inside the SEM chamber. Load data were correlated with both AE information and observations of microcracks around grain boundaries as well as secondary cracks, voids, and slip bands. The preliminary results are in excellent agreement with similar findings at the mesoscale. Extensions of the application of this novel technique are discussed.

Wisner, Brian↗

Machine learning for automated experimentation in scanning transmission electron microscopy

Abstract Machine learning (ML) has become critical for post-acquisition data analysis in (scanning) transmission electron microscopy, (S)TEM, imaging and spectroscopy. An emerging trend is the transition to real-time analysis and closed-loop microscope operation. The effective use of ML in electron microscopy now requires the development of strategies for microscopy-centric experiment workflow design and optimization. Here, we discuss the associated challenges with the transition to active ML, including sequential data analysis and out-of-distribution drift effects, the requirements for edge operation, local and cloud data storage, and theory in the loop operations. Specifically, we discuss the relative contributions of human scientists and ML agents in the ideation, orchestration, and execution of experimental workflows, as well as the need to develop universal hyper languages that can apply across multiple platforms. These considerations will collectively inform the operationalization of ML in next-generation experimentation.

36 MATERIALS SCIENCE↗

Probing Plasmonic Near-Fields in Oxide-Modified Aluminum Nanocubes Using Photon-Induced Near-Field Electron Microscopy

Plasmonic nanoparticles generate strong electric fields near their surface upon photoexcitation, enabling applications in sensing, spectroscopy, and photocatalysis. Electron microscopy techniques – such as cathodoluminescence and electron energy loss spectroscopy – have been leveraged to produce nanoscale maps of localized surface plasmon (LSP) modes. More recently, photon-induced near-field electron microscopy (PINEM) has emerged as a powerful technique for imaging evanescent near-fields generated by ultrafast laser excitation. In this work, we employ PINEM within an ultrafast electron microscope, complemented by numerical calculations to investigate how optical polarization, surface modification, and light intensity affect the evanescent fields associated with LSPs on oxide-modified aluminum nanocubes. Polarization control of the incident light field enables spatial mapping of the nanocube’s LSPs at the single particle level. Systematic variation of the oxide layer thickness reveals that increased coating thickness correlates with a stronger PINEM signal and a greater energy gain of probing electrons. Additionally, higher light intensities at fixed polarization and oxide coating further amplify the PINEM signal. These findings demonstrate the utility of PINEM as a high-resolution technique for optical near-field imaging and spectroscopy of single plasmonic nanoparticles. The ability to probe single particle behavior offers new opportunities for advancing the design and characterization of nanophotonic and plasmonic materials.

PINEM↗

Facile Tensile Testing Platform for In Situ Transmission Electron Microscopy of Nanomaterials

In situ tensile testing using transmission electron microscopy (TEM) is a powerful technique to probe structure-property relationships of materials at the atomic scale. In this work, a facile tensile testing platform for in situ characterization of materials inside a transmission electron microscope is demonstrated. The platform consists of: 1) a commercially available, flexible, electron-transparent substrate (e.g., TEM grid) integrated with a conventional tensile testing holder, and 2) a finite element simulation providing quantification of specimen-applied strain. The flexible substrate (carbon support film of the TEM grid) mitigates strain concentrations usually found in free-standing films and enables in situ straining experiments to be performed on materials that cannot undergo localized thinning or focused ion beam lift-out. The finite element simulation enables direct correlation of holder displacement with sample strain, providing upper and lower bounds of expected strain across the substrate. The tensile testing platform is validated for three disparate material systems: sputtered gold-palladium, few-layer transferred tungsten disulfide, and electrodeposited lithium, by measuring lattice strain from experimentally recorded electron diffraction data. The results show good agreement between experiment and simulation, providing confidence in the ability to transfer strain from holder to sample and relate TEM crystal structural observations with material mechanical properties.

2D materials↗

Unveiling Spatial and Temporal Dynamics of Plasmon-Enhanced Localized Fields in Metallic Nanoframes through Ultrafast Electron Microscopy

Plasmonic nanomaterials, particularly noble metal nanoframes (NFs), are important for applications such as catalysis, biosensing, and energy harvesting due to their ability to enhance localized electric fields and atomic efficiency via localized surface plasmon resonance (LSPR). Yet the fundamental structure-function relationships and plasmonic dynamics of the NFS are difficult to study experimentally and thus far rely predominately on computational methodologies, limiting their utilization. This study leverages the capabilities of ultrafast electron microscopy (UEM), specifically photon-induced near-field electron microscopy (PINEM), to probe the light-matter interactions within plasmonic NF structures. Here, the effects of shape, size, and plasmonic coupling of Pt@Au core-shell NFs on spatial and temporal characteristics of plasmon-enhanced localized electric fields are explored. Importantly, time-resolved PINEM analysis reveals that the plasmonic fields around hexagonal NF prisms exhibit a spatially dependent excitation and decay rate, indicating a nuanced interplay between the spatial geometry of the NF and the temporal evolution of the localized electric field. These results and observations uncover nanophotonic energy transfer dynamics in NFs and highlight their potential for applications in biosensing and photocatalysis.

Plasmonics↗

Variable Pressure - Scanning Electron Microscopy (VP-SEM)

Variable Pressure (or Environmental) Scanning Electron Microscopy (VP-SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) is one of the most powerful methods for characterizing the sub-micron topography and chemical composition of uncoated samples. Terrestrially, VP-SEM is extensively used to non-destructively study geologic and manufactured materials with high spatial resolution (tens of nanometers) and large depth-of-field. An SEM offers a geologist a first survey of microscopic mineral phases via secondary electron imaging (SEI), which provides a topographic look at a sample, as well as backscattered electron (BEI) imaging, which contrasts the phases present based on their geochemistry (atomic number). A VP-SEM utilizes a gas in the sample chamber as a charge dissipation and signal amplification method, allowing analysis of a sample without preparation in the form of a conductive coating. A miniaturized VP-SEM operating in-situ on a lander or rover would be able to use the CO2-rich Martian atmosphere (e.g., Nier et al., 1976; Williams 2016) as an imaging medium for this purpose. Adaptation of a VP-SEM for in-situ Mars surface studies will provide a new imaging capability (via SEI) that is at least an order of magnitude higher resolution than the Mars Hand Lens Imager (MAHLI) on the Mars Science Laboratory (Williams et al., 2015), and equal to or better than the achieved resolution of the Atomic Force Microscope on the Phoenix Mars lander (Pike et al., 2011). In addition, the MVP-SEM is capable of BSI and simultaneous chemical analysis of the imaged region. In this sense, the MVP-SEM can be regarded as an instrument suite that will provide a new set of information not achievable by any other instrument. The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) was designed, built, and benchtop tested by a team at NASA’s Marshall Space Flight Center and Jet Propulsion Laboratory (JPL), Jacobs Space Exploration Group, Applied Physics Technologies, Inc. (AP-Tech), and Creare LLC, working with a team of technical and science collaborators. Benchtop testing was successful, proving concept feasibility. To date, the MVP-SEM has achieved an imaging resolution of <100 nm in the lab, and with continued optimization, even better performance (~50 nm resolution) is possible. Use in-situ on the lunar or other planetary surfaces would require some redesign to optimize instrument performance, but such an instrument would be equally useful.

Variable Pressure Scanning Electron Microscopy↗