Search NASA⌕ Search

SEARCH · Search NASA

Results for “End Use Load Profile”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Hubble Space Telescope six-battery nickel-cadmium mission simulation test

A simulation test of the six-battery nickel-cadmium mission to determine battery life and electrical power system (EPS) performance characteristics for the Hubble Space Telescope (HST) program, is described. The basic HST power system requirements are to provide power generation, energy storage, and EPS control and distribution for 2.5 years with the nickel-cadmium (NiCd) batteries at an end of life solar array of 2 years. Mission simulation life testing begain in April of 1986, and the batteries have completed their 2.5 year mission requirement. Conditions as close as practical to the actual predicted mission profiles were used. These included solar array degradation, load variations, beta angle changes, temperature changes (with excursions to 10 C), battery reconditioning, safemode simulations, and off-normal roll activities. Discounting system cycling interruptions caused by hardware, software, human error, and periodic updates and revisions, the HST EPS breadboard hardware operated continuously for 30 months and demonstrated the power system's ability to meet the HST requirement.

Jackson, Lorna G.↗

Estimated Probability of a Cervical Spine Injury During an ISS Mission

Introduction: The Integrated Medical Model (IMM) utilizes historical data, cohort data, and external simulations as input factors to provide estimates of crew health, resource utilization and mission outcomes. The Cervical Spine Injury Module (CSIM) is an external simulation designed to provide the IMM with parameter estimates for 1) a probability distribution function (PDF) of the incidence rate, 2) the mean incidence rate, and 3) the standard deviation associated with the mean resulting from injury/trauma of the neck. Methods: An injury mechanism based on an idealized low-velocity blunt impact to the superior posterior thorax of an ISS crewmember was used as the simulated mission environment. As a result of this impact, the cervical spine is inertially loaded from the mass of the head producing an extension-flexion motion deforming the soft tissues of the neck. A multibody biomechanical model was developed to estimate the kinematic and dynamic response of the head-neck system from a prescribed acceleration profile. Logistic regression was performed on a dataset containing AIS1 soft tissue neck injuries from rear-end automobile collisions with published Neck Injury Criterion values producing an injury transfer function (ITF). An injury event scenario (IES) was constructed such that crew 1 is moving through a primary or standard translation path transferring large volume equipment impacting stationary crew 2. The incidence rate for this IES was estimated from in-flight data and used to calculate the probability of occurrence. The uncertainty in the model input factors were estimated from representative datasets and expressed in terms of probability distributions. A Monte Carlo Method utilizing simple random sampling was employed to propagate both aleatory and epistemic uncertain factors. Scatterplots and partial correlation coefficients (PCC) were generated to determine input factor sensitivity. CSIM was developed in the SimMechanics/Simulink environment with a Monte Carlo wrapper (MATLAB) used to integrate the components of the module. Results: The probability of generating an AIS1 soft tissue neck injury from the extension/flexion motion induced by a low-velocity blunt impact to the superior posterior thorax was fitted with a lognormal PDF with mean 0.26409, standard deviation 0.11353, standard error of mean 0.00114, and 95% confidence interval [0.26186, 0.26631]. Combining the probability of an AIS1 injury with the probability of IES occurrence was fitted with a Johnson SI PDF with mean 0.02772, standard deviation 0.02012, standard error of mean 0.00020, and 95% confidence interval [0.02733, 0.02812]. The input factor sensitivity analysis in descending order was IES incidence rate, ITF regression coefficient 1, impactor initial velocity, ITF regression coefficient 2, and all others (equipment mass, crew 1 body mass, crew 2 body mass) insignificant. Verification and Validation (V&V): The IMM V&V, based upon NASA STD 7009, was implemented which included an assessment of the data sets used to build CSIM. The documentation maintained includes source code comments and a technical report. The software code and documentation is under Subversion configuration management. Kinematic validation was performed by comparing the biomechanical model output to established corridors.

Brooker, John E.↗

Feasibility of Achieving a Zero-Net-Energy, Zero-Net-Cost Homes

A green building competition, to be known as the Energy Free Home Challenge (EFHC), is scheduled to be opened to teams around the world in 2010. This competition will encourage both design innovation and cost reduction, by requiring design entries to meet 'zero net energy' and 'zero net cost' criteria. For the purposes of this competition, a 'zero net energy' home produces at least as much energy as it purchases over the course of a year, regardless of the time and form of the energy (e.g., electricity, heat, or fuel) consumed or produced. A 'zero net cost' home is no more expensive than a traditional home of comparable size and comfort, when evaluated over the course of a 30-year mortgage. In other words, the 'green premium' must have a payback period less than 30 years, based on the value of energy saved. The overarching goal of the competition is to develop affordable, high-performance homes that can be mass-produced at a large scale, and are able to meet occupant needs in harsh climates (as can be found where the competition will be held in Illinois). This report outlines the goals of the competition, and gauges their feasibility using both modeling results and published data. To ensure that the established rules are challenging, yet reasonable, this report seeks to refine the competition goals after exploring their feasibility through case studies, cost projections, and energy modeling. The authors of this report conducted a survey of the most progressive home energy-efficiency practices expected to appear in competition design submittals. In Appendix A, a summary can be found of recent projects throughout the United States, Canada, Germany, Switzerland, Sweden and Japan, where some of the most progressive technologies have been implemented. As with past energy efficient home projects, EFHC competitors will incorporate a multitude of energy efficiency measures into their home designs. The authors believe that the cost of electricity generated by home generation technologies will continue to exceed the price of US grid electricity in almost all locations. Strategies to minimize whole-house energy demand generally involve some combination of the following measures: optimization of surface (area) to volume ratio; optimization of solar orientation; reduction of envelope loads; systems-based engineering of high efficiency HVAC components, and on-site power generation. A 'Base Case' home energy model was constructed, to enable the team to quantitatively evaluate the merits of various home energy efficiency measures. This Base Case home was designed to have an energy use profile typical of most newly constructed homes in the Champaign-Urbana, Illinois area, where the competition is scheduled to be held. The model was created with the EnergyGauge USA software package, a front-end for the DOE-2 building energy simulation tool; the home is a 2,000 square foot, two-story building with an unconditioned basement, gas heating, a gas hot-water heater, and a family of four. The model specifies the most significant details of a home that can impact its energy use, including location, insulation values, air leakage, heating/cooling systems, lighting, major appliances, hot water use, and other plug loads. EFHC contestants and judges should pay special attention to the Base Case model's defined 'service characteristics' of home amenities such as lighting and appliances. For example, a typical home refrigerator is assumed to have a built-in freezer, automatic (not manual) defrost, and an interior volume of 26 cubic feet. The Base Case home model is described in more detail in Section IV and Appendix B.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal FEA for Front End Fixed Mask (SST)

The purpose of this study was to determine the temperature of the Fixed Mask using heat loads of the U42 Undulator. Finite Element Analysis was conducted on the fixed mask, to determine the temperature distribution on it, for 500 milli-amp current for NSLS-II. The Fixed mask has the sine wave surface profile.

36 MATERIALS SCIENCE↗

Magnetic and Thermal Design of HTS Quadrupole Magnet for Newly Developed Superconducting Proton Cyclotron Beam Line

A magnetic and thermal design of high-temperature superconducting (HTS) quadrupole magnet for newly developed superconducting proton cyclotron was presented in this research. With superconducting technology, the design can reduce the magnet size and remove the heat loads more efficiently. Calculations are conducted with finite element method (FEM) to study the quadrupole magnet’s magnetic and thermal properties. For the magnet cold-mass and cryostat system, the heat load is mainly generated by conduction and radiation. Multilayer thermal insulation and G10 supports are used to restrict them. The magnetic field distribution in the HTS coils is calculated to consider the critical current degradation of the YBCO tapes. The effects on the field gradient quality in relation to the pole tip profile and end chamfer are analyzed. The sixth multipole component in the integral field can be improved with end chamfer. Finally, a 20 T/m HTS quadrupole magnet with integral field uniformity less than 0.05% out to 75% of the inscribed radius is proposed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Transmission diamond imaging detector

Many modern synchrotron techniques are trending toward use of high flux beams and/or beams which require enhanced stability and precise understanding of beam position and intensity from the front end of the beamline all the way to the sample. For high flux beams, major challenges include heat load management in optics (including the vacuum windows) and a mechanism of real-time volumetric measurement of beam properties such as flux, position, and morphology. For beam stability in these environments, feedback from such measurements directly to control systems for optical elements or to sample positioning stages would be invaluable. To address these challenges, we are developing diamond-based instrumented vacuum windows with integrated volumetric x-ray intensity, beam profile and beam-position monitoring capabilities. A 50 µm thick single crystal diamond has been lithographically patterned to produce 60 µm pixels, creating a >1kilopixel free-standing transmission imaging detector. This device, coupled with a custom, FPGA-based readout, has been used to image both white and monochromatic x-ray beams and capture the last x-ray photons at the National Synchrotron Light Source (NSLS). This technology will form the basis for the instrumented end-station window of the x-ray footprinting beamline (XFP) at NSLS-II.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

End-Use Savings Shapes Measure Documentation: Console Water-to-Air Geothermal Heat Pump

Executive Summary Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past several years, the objective of this work is to produce national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover most of the high-impact, market-ready (or nearly market-ready) measures. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. This measure models the conversion of an existing heating, ventilating, and air-conditioning (HVAC) system to a series of “console” water-to-air heat pumps served by a ground heat exchanger. Console water-to-air geothermal heat pumps (GHP) are all-in-one packages that have no or minimal ductwork and serve individual spaces. Properly designed ground heat exchanger-coupled systems can offer benefits in energy efficiency relative to “conventional” HVAC systems, as well as facilitating beneficial electrification. Console GHPs can be coupled to a ground loop on the source side and can directly replace electric baseboard heaters or air-source packaged terminal heat pumps. Console GHPs can also bring in outdoor air for ventilation. This measure will be referred to throughout the document as the “Console GHP” upgrade.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Studies on questions of design and construction of chain scraper conveyors

The basic behavior of mining crushed goods in chain scraper conveyors was examined using a special test stand. The characteristics resistance lines of the upper end-piece were determined for conveyor idle as a function of the determinative crushed good characteristics (granular structure, moisture content, type of goods) on the size of the conveyor load, on the conveyor construction and on the stopped time of the conveyor. Crushed goods with a narrow granular profile and sphere-like grains caused about 35% greater resistance than fine coal and raw coal with broad granular profile. For goods containing water more than 10% by weight, the solids friction retreated in favor of flow friction. The coefficient of resistance decreased considerably in the range of lower speeds and then increased with increasing conveyor speed. The conveyance of sandstone ore required about 280% greater specific drive than the conveyance of raw coal. Resistance coefficients for coal and raw coal showed no dependence on the design of the conveyor. Start-up of loaded conveyors after longer stop times was simulated and the specific break-loose force was determined.

Guder, H.↗

Studying the Impact of Distributed Solar PV on Power Systems Using Integrated Transmission and Distribution Models

Rapid growth of distributed energy resources has prompted increasing interest in integrated Transmission (T) and Distribution (D) modeling. This paper presents the results of a distributed generation from solar photovoltaics (DGPV) impact assessment study that was performed using a synthetic T &D model. The primary objective of the study was to present a new approach for DGPV impact assessment, where along with detailed models of transmission and distribution networks, consumer loads were modeled using the physics of end-use equipment, and DGPV was geographically dispersed and connected to the secondary distribution networks. The study highlights (i) how a lack of DGPV forecasting can increase the Area Control Error (ACE) at the transmission level for high penetration levels; and (ii) how capturing transmission voltage changes using integrated T &D can change simulated distribution voltage profiles and voltage regulator operations between integrated T &D and distribution-only simulations.

14 SOLAR ENERGY↗

Epitaxial growth of Hg/1-x/Cd/x/Te by chemical vapor transport

The chemical vapor transport technique was applied for the first time to the growth of Hg(1-x)Cd(x)Te epitaxial layers on CdTe substrates using a preannealed source material of Hg(0.8)Cd(0.2)Te. The experiment took place in a pretreated ampoule loaded with source material, HgI2 transport agent, and substrate and sealed under a residual pressure of about 10 to the -5th torr. The temperature of the source region was 590 C and that of the deposition zone 535 C with a nearly sigmoidal shaped profile between the end temperatures. The change in appearance of the substrate surface during the experiment is described, and the structures of the surface of the Hg(1-x)Cd(x)Te layer and of the layer itself as revealed by Nomarski contrast illumination and Laue X-ray diffraction, respectively, are discussed.

Wiedemeier, H.↗

Maximum Photovoltaic Penetration Levels on Typical Distribution Feeders: Preprint

This paper presents simulation results for a taxonomy of typical distribution feeders with various levels of photovoltaic (PV) penetration. For each of the 16 feeders simulated, the maximum PV penetration that did not result in steady-state voltage or current violation is presented for several PV location scenarios: clustered near the feeder source, clustered near the midpoint of the feeder,clustered near the end of the feeder, randomly located, and evenly distributed. In addition, the maximum level of PV is presented for single, large PV systems at each location. Maximum PV penetration was determined by requiring that feeder voltages stay within ANSI Range A and that feeder currents stay within the ranges determined by overcurrent protection devices. Simulations were run inGridLAB-D using hourly time steps over a year with randomized load profiles based on utility data and typical meteorological year weather data. For 86% of the cases simulated, maximum PV penetration was at least 30% of peak load.

14 SOLAR ENERGY↗

Efficacy of Dried Plum to Countermeasure Simulated Spaceflight Exposure

Human exploration of the space environment has been a topic of interest for decades; however, the threat to physiological health posed by ionizing radiation and microgravity effects remains a concern. Previous research utilizing combined hindlimb unloading and irradiation to simulate spaceflight effects found that a dried plum diet can mitigate adverse effects of simulated spaceflight on skeletal health. Though the mechanism is not fully understood we believe this protective effect is due to its high antioxidant capacity and polyphenolic content. This study seeks to extend these findings to investigate if dried plum is an effective countermeasure in other tissues relating to aging and neurotoxicity. Male C57BL/6 J mice were assigned to one of eight groups (n = 10/group) and were fed either a controlled diet or dried plum diet, underwent normal loading or hindlimb unloading as well as exposure 2 Gy gamma radiation or sham exposure. At the end of the experiment, mice were euthanized, and RNA was extracted from brain and bone marrow tissue and PCR was employed to analyze significant changes in gene expression profiles. Analysis of five house-keeping genes revealed genes B2M (neurotoxicity) and GUSB (aging) to be the most stable genes across all treatments and were used to find the fold change within our genes of interest. Through this, and analysis via ANOVA, we were able to identify genes with significant altered expression levels within brain and bone marrow tissues related to neurotoxicity and aging. Considering previous research, we hypothesize that the dried plum diet’s antioxidative properties ameliorated the oxidative stress from irradiation and microgravity via altered levels of gene expression. Identified expression changes will provide insights into molecular mechanisms behind the observed protective effects. These findings present potential avenues for future interventions to alleviate negative impacts of spaceflight on astronaut health.

Faisal Ahmad↗

The Efficacy of Dried Plum to Counter Spaceflight Microgravity and Radiation

Human exploration of the space environment has been a topic of interest for decades; however, the threat to physiological health posed by ionizing radiation and microgravity effects remains a concern. Previous research utilizing combined hindlimb unloading and irradiation to simulate spaceflight effects found that a dried plum diet can mitigate adverse effects of simulated spaceflight on skeletal health. Though the mechanism is not fully understood we believe this protective effect is due to its high antioxidant capacity and polyphenolic content. This study seeks to extend these findings to investigate if dried plum is an effective countermeasure in other tissues relating to aging and neurotoxicity. Male C57BL/6 J mice were assigned to one of eight groups (n = 10/group) and were fed either a controlled diet or dried plum diet, underwent normal loading or hindlimb unloading as well as exposure 2 Gy gamma radiation or sham exposure. At the end of the experiment, mice were euthanized, and RNA was extracted from brain and bone marrow tissue and PCR was employed to analyze significant changes in gene expression profiles. Analysis of five house-keeping genes revealed genes B2M (neurotoxicity) and GUSB (aging) to be the most stable genes across all treatments and were used to find the fold change within our genes of interest. Through this, and analysis via ANOVA, we were able to identify genes with significant altered expression levels within brain and bone marrow tissues related to neurotoxicity and aging. Considering previous research, we hypothesize that the dried plum diet’s antioxidative properties ameliorated the oxidative stress from irradiation and microgravity via altered levels of gene expression. Identified expression changes will provide insights into molecular mechanisms behind the observed protective effects. These findings present potential avenues for future interventions to alleviate negative impacts of spaceflight on astronaut health.

Faisal Ahmad↗

Stochastic Virtual Battery Modeling of Uncertain Electrical Loads using Variational Autoencoder

Effective utilization of flexible loads for grid services, while satisfying end-user preferences and constraints, requires an accurate estimation of the aggregated predictive flexibility offered by the electrical loads. Recently, there have been efforts to quantify the predictive flexibility of thermostatic loads (e.g. residential air-conditioners, electric water-heaters) using the notion of virtual battery (VB), whose state evolution is governed by a first order dynamics including self-dissipation rate, and power and energy capacities. Identifying the VB model parameters for a collection of thermostatic loads, however, is challenging primarily due to uncertainties and lack of information regarding the end-user behavior, underlying device models and parameters. In this paper, we propose a \textit{variational autoencoder}-based deep learning algorithm to identify the parameters of the VB model. Using available sensors and meters data, the proposed algorithm generates not only point estimates of the VB parameters, but also confidence intervals around those values. Effectiveness of the proposed frameworks is demonstrated on a collection of electric water-heater loads, whose operation is driven by uncertain water usage profiles.

virtual battery, deep learning algorithms↗

Field Trial of a Low-Cost, Distributed Plug Load Monitoring System

Researchers have struggled to inventory and characterize the energy use profiles of the ever-growing category of so-called miscellaneous electric loads (MELs) because plug-load monitoring is cost-prohibitive to the researcher and intrusive to the homeowner. However, these data represent a crucial missing link to understanding how homes use energy. Detailed energy use profiles would enable the nascent automated home energy management (AHEM) industry to develop effective control algorithms that target consumer electronics and other plug loads. If utility and other efficiency programs are to incent AHEM devices, they need large-scale datasets that provide statistically meaningful justification of their investments by quantifying the aggregate energy savings achievable. To address this need, NREL researchers investigated a variety of plug-load measuring devices available commercially and tested them in the laboratory to identify the most promising candidates for field applications. This report centers around the lessons learned from a field validation of one proof-of-concept system, called Smartenit (formerly SimpleHomeNet). The system was evaluated based on the rate of successful data queries, reliability over a period of days to weeks, and accuracy. This system offers good overall performance when deployed with up to 10 end nodes in a residential environment, although deployment with more nodes and in a commercial environment is much less robust. NREL concludes that the current system is useful in selected field research projects, with the recommendation that system behavior is observed over time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Trial of a Low-Cost, Distributed Plug Load Monitoring System

Researchers have struggled to inventory and characterize the energy use profiles of the ever-growing category of so-called miscellaneous electric loads (MELs) because plug-load monitoring is cost-prohibitive to the researcher and intrusive to the homeowner. However, these data represent a crucial missing link to our understanding of how homes use energy, and we cannot control what we do not understand. Detailed energy use profiles would enable the nascent automated home energy management (AHEM) industry to develop effective control algorithms that target consumer electronics and other plug loads. If utility and other efficiency programs are to incent AHEM devices, they need large-scale datasets that provide statistically meaningful justification of their investments by quantifying the aggregate energy savings achievable. To address this need, we have investigated a variety of plug-load measuring devices available commercially and tested them in the laboratory to identify the most promising candidates for field applications. The scope of this report centers around the lessons learned from a field validation of one proof-of-concept system, called Smartenit (formerly SimpleHomeNet). The system was evaluated based on the rate of successful data queries, reliability over a period of days to weeks, and accuracy. This system offers good overall performance when deployed with up to ten end nodes in a residential environment, although deployment with more nodes and in a commercial environment is much less robust. We conclude that the current system is useful in selected field research projects, with the recommendation that system behavior is observed over time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Role of deformation twinning in fatigue of CrCoNi medium-entropy alloy at room temperature

Here cylindrical specimens of CrCoNi alloy with electropolished surfaces were subjected to constant total strain amplitude low cycle fatigue. The alloy exhibited an initial period of cyclic hardening followed by cyclic softening until failure occurred. At the end of hardening stage at the peak of cyclic stress, well-developed persistent slip markings (PSMs) consisting of extrusions and intrusions were associated with thin deformation twins. A sophisticated experimental workflow was designed to extract information from the surface and the bulk of tested material. A combination of SEM, EBSD, ECCI, FIB and HR-STEM was used to study the internal structure and the surface profiles around the deformation twins, which were produced during the initial period of cyclic loading. Furthermore, localized cyclic plastic strain and stress concentrations near deformation twins led not only to early, well-developed PSMs, but also to the activation of TWIP and TRIP plasticity even at low macroscopic stress amplitudes.

36 MATERIALS SCIENCE↗